| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC GALI BAWARI WALI NOHARIA BAZAAR SIRSA 125055 HARYANA | SIRSA | HARYANA | 125055 | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.9 L+₹45,508.90 (1.79%)Rejected-Finance NOT FOUND | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹26.7 L+₹1.2 L (4.85%)Rejected-Finance 4 BY 8 BLOCK H NEAR VIJAY CHOWK EAST DELHI DELHI 110051 | EAST DELHI | DELHI | 110051 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹27.8 L+₹2.3 L (9.14%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹28.6 L+₹3.2 L (12.5%)Rejected-Finance NAGAR PANCHAYAT PATHARDEVA DEORIA | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | YESH BUILDERS L1 | shiv shanker enterprises L2 | M/s Shree Bala Ji Construction Company L5 | M/S Aggarwal construction co. L3 | Ajay Enterprises L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE 'A' PART-I (BUILDING WORKS) | - | - | - | - | - | - | - |
| 1.01 | Dismantling structural steel work of any description in rafters, purlins and wind ties etc and removal from site complete all as specified and directed.
NOTE: If the planned MS structure, truss, etc is different from the existing structure, proper measurement of the existing structure to be demolished, shall be recorded in MB duly signed by the Engineer-in-Charge. | 0.5 | QTL | 50 ₹25 | 125 ₹62.5 | 100 ₹50 | 10 ₹5 Lowest | 10 ₹5 Lowest |
| 1.02 | Dismantling of Asbestos cement (corrugated, semi-corrugated, plain, etc.) sheets in roof/wall coverings and removal from site complete all as specified and directed. | 22 | SQM | 5 ₹110 | 15 ₹330 | 10 ₹220 | 2 ₹44 Lowest | 5 ₹110 |
| 1.03 | Taking down damaged/unserviceable Steel / Wooden Chowkat or Frame not exc. 1.50 Sqm Each with shutter (without taking off shutter from the frame) and removal from site complete all as specified and directed. | 4 | EACH | 5 ₹20 Lowest | 100 ₹400 | 50 ₹200 | 10 ₹40 | 15 ₹60 |
| 1.04 | Demolition Cement Concrete (un-reinforced) of any description and in any position and removing debris, etc. to Outside MD/AF Land, complete all as specified and directed. | 0.04 | CUM | 50 ₹2 | 250 ₹10 | 50 ₹2 | 50 ₹2 | 15 ₹0.6 Lowest |
| 1.05 | Taking down Cement Plaster including raking out Joints, hacking for Key, scrubbing down with Water and removing Debris, etc. to Outside MD/AF Land, complete all as specified and directed. | 35 | SQM | 7 ₹245 Lowest | 14 ₹490 | 9 ₹315 | 15 ₹525 | 10 ₹350 |
| 1.06 | Excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. | 34 | EACH | 50 ₹1,700 Lowest | 125 ₹4,250 | 100 ₹3,400 | 50 ₹1,700 Lowest | 50 ₹1,700 Lowest |
| 1.07 | M&L cement concrete 1:2:4 type B2 (using 40mm graded stone aggregate) as in filling and mass concrete complete all as specified and directed. | 1 | CUM | 2,700 ₹2,700 | 3,500 ₹3,500 | 3,200 ₹3,200 | 3,000 ₹3,000 | 2,500 ₹2,500 Lowest |
| 1.08 | M&L for steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 or RHS/SHS Sections conforming to IS 4923:1997 grade YST 210 complete all as specified and directed.
(NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. No extra measurement for the same will be considered except for base plates at top & bottom of columns) | 4,100 | KG | 79 ₹3,23,900 Lowest | 79 ₹3,23,900 Lowest | 100 ₹4,10,000 | 90 ₹3,69,000 | 85 ₹3,48,500 |
| 1.09 | M&L for preparing New or previously untreated Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Red Oxide Zinc Chrome Primer, complete all as specified and directed. | 250 | SQM | 29 ₹7,250 | 25 ₹6,250 | 45 ₹11,250 | 20 ₹5,000 Lowest | 35 ₹8,750 |
Tender Value
₹38.7 L
EMD Value
₹77,340
Closing Date
28 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SIRSA
GE (AF) SIRSA, HARYANA-125055
ADDN/ALTN TO BLDG NO. P-501 AND 503 INSIDE TECH AREA AT AF STN SIRSA
2025_MES_718649_1
GE/SRA/T-35/2025-26
Open Tender
Miscellaneous Works
Item Rate
225 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹77,340
Yes
27 Aug 2025
4 Jul 2025
29 Jul 2025
4 Jul 2025
28 Jul 2025
15 Jul 2025
Amount
SCHEDULE 'A' PART-I (BUILDING WORKS)
Dismantling structural steel work of any description in rafters, purlins and wind ties etc and removal from site complete all as specified and directed. NOTE: If the planned MS structure, truss, etc is different from the existing structure, proper measurement of the existing structure to be demolished, shall be recorded in MB duly signed by the Engineer-in-Charge.
Dismantling of Asbestos cement (corrugated, semi-corrugated, plain, etc.) sheets in roof/wall coverings and removal from site complete all as specified and directed.
Taking down damaged/unserviceable Steel / Wooden Chowkat or Frame not exc. 1.50 Sqm Each with shutter (without taking off shutter from the frame) and removal from site complete all as specified and directed.
Demolition Cement Concrete (un-reinforced) of any description and in any position and removing debris, etc. to Outside MD/AF Land, complete all as specified and directed.
Taking down Cement Plaster including raking out Joints, hacking for Key, scrubbing down with Water and removing Debris, etc. to Outside MD/AF Land, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
M&L cement concrete 1:2:4 type B2 (using 40mm graded stone aggregate) as in filling and mass concrete complete all as specified and directed.
M&L for steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 or RHS/SHS Sections conforming to IS 4923:1997 grade YST 210 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. No extra measurement for the same will be considered except for base plates at top & bottom of columns)
M&L for preparing New or previously untreated Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Red Oxide Zinc Chrome Primer, complete all as specified and directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
M&L for Hardcore of broken stone or boulder of gauge not exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for Cement concrete, 100mm thick, type D- 2, 1:4:8 (40mm graded aggregate) in sub floors, sub bases, pavings etc., complete all as specified and as directed.
M&L for laying pre-polished 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. (NOTE: Sand cushioning shall be measured and paid separately)
M&L for sand cushioning with clean river sand duly clear of residual, organic and deleterious materials spread evenly to uniform thickness over PCC Sub Base complete all as specified and directed.
M&L Providing, cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping finished even and smooth without using extra cement complete all as specified and as directed.
S&F false ceiling with powder coated exposed G.I. grid suspension system consisting of Main Runner 3600 mm long, Cross Tee 1200mm/600mm long and Wall Angle, wall angle fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c, Main Runners placed @ 1200mm, Cross Tee 1200mm inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm and additional cross tees of 600 mm placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm, grid of module size 600mm x 600mm shall be supported by 6 mm dia G.I. wire from purlins/soffit complete all as specified and directed. Note: Ceiling board will measured and paid separately under appropriate item.
S&F 12 mm thick mineral fibre ceiling tiles shall be of dimension 595x595mm with humidity resistance 99% Thermal conductivity K = 0.052-0.057 w/mK colour white, fire performance UK Class 0/Class 1 (BS 476 pt-6&7) suitable for green building application (GRIHA Criteria 17 & 29 SWAGRIHA 12) with recycled content not less than 30 % and light reflectance not less than 85%. NRC of 0.55 to 0.6 duly fixed on GI Snap Grid Frame Work with Steel Screws complete all as specified and directed. Note: Snap grid ceiling frame shall be measured separately under appropriate item.
M&L Vitrified Coloured Tiles 9-10mm thick (Square/ Rectangular), Double Charged, Light shade, Polished, area of each Tile not exc. 0.36 Square Metre in Floors, etc. Set in Neat Cement Slurry, laid over and including 15mm thick Screed or Screed Bed in Cement Mortar 1:4, tiles fixed with spacers to provide provide a uniform spacing of 3mm between the tiles and after setting of screed bed and tiles, removing the spacers and filling the joints with suitable epoxy grout and pointed with grout complete all as specified and directed. NOTE : Cost of cement screed bed, tile adhesive and epoxy grout shall deemed to be included in the quoted rate.
M&L Vitrified Coloured Tiles 9 to 10mm thick (Square/ Rectangular) Double Charge, Light shade, Polished, area of each Tile not exc. 0.36 Square Metre in Vertical Surface i.e. Dado, Skirting, etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick Screed or Screed Bed in Cement Mortar 1:4, tiles fixed with spacers to provide provide a uniform spacing of 3mm between the tiles and after setting of screed bed and tiles, removing the spacers and filling the joints with suitable epoxy grout and pointed with grout complete all as specified and directed. NOTE : Cost of cement screed bed, tile adhesive and epoxy grout shall deemed to be included in the quoted rate.
M&L for providing non-skid/matt finish Ceramic tiles, coloured, 7-8 mm thick (Square / rectangular), area of each tile exc 0.11 Sqm but not exceeding 0.18 Sqm in Flooring, set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the tiles laid over and including 15mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and directed. NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate.
M&L for Coloured Glazed Ceramic Tiles in vertical surface 450mm X 350mm X 6-7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the Tiles, laid over and including 10mm thick rendering as Screed or backing coat of wall tile in Cement Mortar 1:3, complete all as specified and directed. NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate.
M&L Cement Concrete 1:2:4 type B0 (12.5mm graded stone aggregate) 25mm thick in Sub-base for laying of Tiles in Floor, complete all as specified and directed.
M&L Cement Concrete 1:3:6 type C-2 (40mm graded stone aggregate), 100mm thick as in sub base of floor, path etc complete all as specified and as directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavating in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed.
Excavating over areas, in soft/loose soil, not exc 1.5 m deep and getting out complete all as specified and directed.
Excavating over areas, in soft/loose soil, depth exc 1.5m but not exc 3.0 m deep and getting out complete all as specified and directed.
M&L for brickwork with fly-ash bricks (with old size bricks), straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed
M&L Brick Work with Fly-Ash Bricks (Old Size Bricks) in One Brick thick Walls Honey Comb Walling, built in Cement Mortar 1:4, complete all as specified and as directed.
M&L Loose Filling with Aggregates of gauge 80mm to 150mm (Broken Bricks) in Soakage Pits, Soakage Wells, etc., complete all as specified and as directed.
M&L for Cement Concrete 1:3:6 type C2 (40mm Graded Stone Aggregate), 75mm thick, as in plinth protection finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.
Returning filling including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified and as directed.
Earth filling under floor including spreading, levelling, watering and well ramming in layers n exc. 25cm thick complete all as specified and as directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point. complete all as specified and directed.
M&L for treating the backfill in contact with foundation @ 7.5 litres of emulsion per square metre of vertical surface (area of substructure in contact with the backfill to be measured) complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for treating the soil alongwith external perimeter of building at the rate of 2.25 litres of emulsion per metre of the perimetre wall complete all as specified and directed.
M&L cement concrete 1:4:8 of type D2 (using 40mm graded stone aggregate) as in filling and mass concrete complete all as specified and as directed.
M&L for RCC design mix (M-25 grade) using 20mm grade aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L for RCC design mix (M-25 grade) using 20mm grade aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L RCC M-25 (Design Mix) in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed. (NOTE: Reinforcement shall be measured and paid separately)
M&L RCC M-25 (Design Mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like., complete all as specified and as directed. (NOTE: Reinforcement shall be measured and paid separately)
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces complete all as specified and directed
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces complete all as specified and directed
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces complete all as specified and directed
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping for rough finished surfaces complete all as specified and directed
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces complete all as specified and directed
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required as in reinforcement and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed
M&L for brickwork with fly-ash bricks (with old size bricks), straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed
M&L for damp proof course to horizontal or vertical surfaces 25 mm thick including necessary formwork in cement concrete 1:2:4, type B0 using 12.5 mm graded aggregates complete all as specified and directed.
Supply and laying Polythene film, 150 micron thick, laid over and including a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm complete all as specified and directed
M&L Rendering (Internal) 15mm thick in Cement Mortar 1:6 on other than fair faces of Brick Walls, Surfaces finished Even and Smooth without using Extra Cement complete all as specified and as directed.
M&L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (as per manufacturer's instructions) on fair faces of brick walls or concrete surfaces finished even and fair (up to any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured & paid separately as "Supply only".
Supply only Liquid Water Proofing Compound, conforming to IS code or as approved, complete all as specified.
M&L Rendering 10mm thick in Cement Mortar 1:4 on concrete surfaces, Surfaces finished Even and Smooth without using Extra Cement complete all as specified and as directed.
M&L Rendering 5.0mm thick in Cement Mortar 1:3 on Concrete Surfaces as in Ceiling, etc., Plastered Surfaces finished Even and Smooth, without using Extra Cement, complete all as specified and as directed.
M&L Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed with Coarse Sand and Cement in the ratio 1:1:1 shall be applied and finish Even complete all as specified and as directed.
M&L for preparing New/Undecorated Plastered Surfaces of Walls, applying a coat of suitable cement primer followed by a Coat of 2.0 mm thick Wall Putty (in two layers of 1mm thick) including rubbing down with Sand Paper to obtain a smooth finish surface and finishing with Two Coats of Acrylic Distemper (as approved) as per desired shade/tint complete all as specified and as directed.
M&L for preparation of plastered surfaces of ceilings and applying Two Coats of Acrylic Distemper (as approved), applied with rollers over and including one coat of cement primer suitable for internal surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces and finished with two coats of exterior acrylic emulsion paint (having anti-dust & anti-algae properties) duly mixed with stainer to achieve approved Tint/shade (in camouflage pattern) over a coat of suitable exterior primer, applied to new wall surfaces of any description, over 10cm width or girth not otherwise described, as per manufacturer's instructions, up to 4 storey height incl necessary scaffolding, safety gear, etc complete all as specified and directed.
M&L for preparation of newly rough cast plastered surfaces and finished with two coats of exterior acrylic emulsion paint (having anti-dust & anti-algae properties) duly mixed with stainer to achieve approved Tint/shade (in camouflage pattern) over a coat of suitable exterior primer, applied to new wall surfaces of any description, over 10cm width or girth not otherwise described, as per manufacturer's instructions, incl necessary scaffolding complete all as specified and directed.
M&L 10 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying oil/solvent based bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Applying a coat of blown type bitumen of grade 85/25 as bonding coat, heated to a working temperature of 180 degree C and applied @ 1.20 Kg per square metre of the surface area. (iv) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyester matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (v) Providing a layer of 120 GSM non-woven geo textile of approved make and laid over the APP membrane and bonded to the water proofing membrane with intermittent touch by heating the membrane by Butane torch as per manufacturers recommendations. (vi) Sealing of all angles & abutments up stands with extra care to ensure perfect bondage. Sealing of edges well into grooves & protect the seal with a polysulphide/polyurethane sealant.
S&F PCC tiles, machine pressed, factory made, of size 25cm x 25cm, 22 mm thick, wih grey cement and no pigment, set, jointed and pointed in neat cement slurry, laid over and including 15mm thick screed bed in cement mortar (1:4) mixed with water proofing compound complete all as specified and directed. Note:- Water Proofing compound shall be measured and paid separetly as "Supply only".
S&F Factory made solid PVC door frame (Chowkhat) of size 100 mm x 45mm made out of 5mm thick single side prelam PVC Sheet & edges painted to match with the prelam sheet, frame reinforced with MS square tube of size 40mm x 20mm of 19 gauge throughout the frame, fixed in opening as per manufacturer instructions complete all as specified and directed.
S&F Factory made solid PVC moulded door shutter, 28 to 30 mm thick (stiles) with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face with particle board core suppling & fixing in the frame at site with aluminium hinges as per specification and fixing in the Frame complete all as specified and directed. NOTE : Hinges will be Measured and Paid under appropriate Item.
S&F Butt hinges, 100mm size, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-22 complete all as specified and directed.
S&F Aluminium alloy Handle 125mm long, cast type, anodised, complete all as specified and directed.
S&F Aluminium Barrel Tower Bolt 150mm long (weight not less than 130 Gram), extruded section, complete all as specified and directed.
S&F Aluminium alloy, anodized, Sliding Door Bolt 200mm long with Hasp Staple (Bolt type) and Fixing Clips of Sheet cast or extruded section and fixing Bolts and Sliding Bolts of extruded section and fixing, complete all as specified and directed.
S&F Rotational Moulded Polyethene Water Storage Tank, 500 Litre Capacity, Cylindrical, Vertical with Closed Top, 3 layered, conforming to IS, hoisted and fixed in Position incl providing new GI tank nipple complete all as specified and directed.
S&F Ball Valve 20mm Dia (minimum Weight 210 Gram), high pressure of PTMT with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe, complete all as specified and directed.
S&F Chlorinated Polyethylene Chloride (CPVC) pipes 20 mm outside dia, SDR-11, having thermal stability for hot and cold water supply including all SDR-11 CPVC plain and brass threaded fittings (such as Bends, Elbows, Tees, Short Pieces, Connectors, Back - Nuts Caps, Plugs, Unions, Flange (core) & flange (ring), reduction Tee, reducing socket, Male & female threaded socket, tank connector etc) fixed / laying walls, ceilings or in floors etc. with suitable size MS clamp of spacing 1.00 mtr etc pipe line complete all as specified and directed. (NOTE: Quoted rate shall deemed to included for cutting chases in brickwork for concealing pipes)
-ditto- but with 25 mm outer dia size CPVC pipes
S&F CPVC Ball valve 20mm (outer dia), screwed both Ends for CPVC pipes, complete all as specified and directed.
S&F CPVC Ball valve 25mm (outer dia), screwed both Ends for CPVC pipes, complete all as specified and directed.
S&F vitreous china floor mounted rimless one piece closet (Pedestal pattern), white, including low level vitreous china valveless syphonic action type flushing cistern with inlet ball valve float, push button, flush pipe incl bracket, P/S trap, Soft close seat cover and connecting fittings complete all as specified and directed. (MAKE : JAQUAR, Cat No: OPS-WHT-15853S300UF / CERA, Model: ESPELLO / PARRYWARE, Model: Omega / HINDWARE, Model: SPELNDOUR)
S&F PVC Connection Pipe 15mm size and 60 Cm in length with Adapter Nuts of PVC, complete all as specified and directed.
S&F angle valve, 15 mm bore, cast copper alloy, chromium plated fancy type, with wall flange fixed to iron pipe complete all as specified and directed. (MAKE: PARRYWARE, CAT NO: G5707A1 / CERA, CAT NO: F201420 / JAQUAR, CAT NO: ARI-CHR-39001B / HINDWARE, CAT NO: F360006CP)
S&F Chromium plated brass two way Angle valve, fancy type, with wall flange fixed to 15 mm bore Iron pipe, complete all as specified and directed. (MAKE: PARRYWARE, CAT NO: G5743A1 / CERA, CAT NO: F2014211 / HINDWARE, CAT No: F360055CP)
S&F Vitreous China White Squatting Pan of size 580x440mm, Orissa Pattern with Integral Foot Rests, ‘P’ or ‘S’ Trap, providing Joints between Flush Pipe and Socket of WC Pan, Cones, India Rubber (nozzles of WC Pan) including provision Concrete Bedding and Making Good to disturbed surfaces complete all as specified and directed.
S&F PVC Flushing Cistern 10 Litre capacity White, Low Level, Valve less, Syphonic action type with Inlet, Ball Valve, Float and Handle, PVC flush Pipe 32mm bore (dia) of suitable Length, a pair of Cast Iron Bracket/ Erecting Stand duly painted including cutting and pinning in Ends, Making Good Disturbed Surfaces in cement mortar 1:3, complete all as specified and as directed.
S&F Bib Tap 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, Short Body with Capstan Head, screwed down, screwed for Iron Pipe or for Brass Ferrule, complete all as specified and directed. (MAKE: PARRYWARE, CAT NO: G5704A1 / CERA, CAT NO: F1019151 / HINDWARE, CAT NO: F650004CP)
S&F 15mm bore chromium plated brass body single lever central hole basin mixer without popup waste system with 450mm long copper pipe and brass nut, complete all as specified and directed. (MAKE: PARRYWARE, CAT NO: G5714A1 / CERA, CAT NO: F1020451 / JAQUAR, CAT NO: ARI-CHR-39001B)
S&F Chromium plated brass Pillar tap, with aerator, fixed to wash hand basin, complete all as specified and directed. (MAKE: PARRYWARE, CAT NO: T5801A1 / CERA, CAT NO: F2014101 / JAQUAR, CAT NO: FUS-CHR-29021)
S&F Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type), provided with 32mm dia Brass Chromium Plated Waste Fitting, PVC waste pipe, brackets incl making good disturbed Surfaces in Cement Mortar 1:3 and filling joints with whte cement complete all as specified and directed. (NOTE: Cost of CP wate coupling and PVC waste pipe is deemed to be included in the quoted rates)
S&F vitreous china, white, counter top wash hand basin, including providing 32 mm dia chromium plated waste coupling and making all necessary connections complete all as specified and directed. (Make of Basin : CERA, Model: CAVELLO, HINDWARE, Model: FABIO / PARRYWARE, Model: FLOAT) (NOTE: Cost of Waste coupling shall deemed to be included in the quoted rate.)
S&F CP bottle trap with internal portion 32mm size and of suitable length as per site requirement for connection to counter top basin complete all as specified and directed.
S&F Chromium Plated health faucet with 01 mtr long stainless steel tube including necessary fitting and fixtures complete all as specified and directed. (MAKE: PARRYWARE, CAT NO: T9355A1 / CERA, CAT NO: F8030110AB / JAQUAR, CAT NO: ALD-CHR-579 / HINDWARE, CAT NO: F160013CP)
S&F toilet paper holder, chromium plated, surface type with flap complete all as specified and directed. (MAKE: PARRYWARE, CAT NO: T5914A1 / CERA, CAT NO: F5013110CH / JAQUAR, CAT NO: CPA-CHR-1153 / HINDWARE, CAT NO: F880003CP)
S&F Chromium plated brass Towel ring, square or round, complete all as specified and directed. (MAKE: PARRYWARE, CAT NO: T6904A1 / CERA, CAT NO: F5013115CH / JAQUAR, CAT NO: ACN-CHR-1121N / HINDWARE, CAT NO: F580003CP)
S&F soap dispenser with glass bottle with chromium plated base complete all as specified and directed. (MAKE: PARRYWARE, CAT NO: T6913A1 / CERA, CAT NO: F5015111CH / JAQUAR, CAT NO: ACN-CHR-1135N / RUHE, MODEL: DROP)
S&F Brass Chromium Plated Tubular Towel Rail 20mm Dia, 60 Cm long with Brackets complete all as specified and directed. (MAKE: PARRYWARE, CAT NO: T5901A1 / CERA, CAT NO: F5013103CH / JAQUAR, CAT NO: AKP-CHR-35711PS / HNDWARE, CAT NO: F580012CP)
S&F stainless steel Grating Round 100mm Dia with waste hole jointing with Solvent Cement complete all as specified and directed.
S&F Glass Shelf (Bath Tray), 600 mm long alongwith all accessories complete all as specified and as directed. (MAKE: PARRYWARE, CAT NO: T6909A1 / JAQUAR, CAT NO: CPA-CHR-1171 / HNDWARE, CAT NO: F880010CP)
M&L for 18-20mm thick Granite Slab (of any type) work (table rubbed and polished), cut to size required, fixed in walls with MS brackets for installation of counter top basin incl making holes and rounding off edges complete all as specified and directed.
S&F Vitreous China, white, half stall urinal flat back with grating and union for discharge pipe (excluding flush pipe and flushing cistern and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and Union for discharge pipe complete all as specified and directed. (NOTE: Quoted rate shall be deemed to include for the cost of waste coupling and waste pipe)
S&F Self closing angle cock pressmatic for urinal with wall flange and 200 mm connecting pipe duly connected with and including brass chromium plated Urinal spreader complete all as specified and directed. (MAKE: CERA, CAT NO: F8070201 & F9020203 or similar model in other approved makes provided in tender.
S&F Gun metal gate valve as per IS : 778-84 Class-1 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions, 15 mm bore complete as all specified and as directed.
-ditto- but for 20 mm bore gate valve
-ditto- but for 25 mm bore gate valve
S&F PVC Floor Trap 110mm bore (dia) with Grating including jointing to Waste Pipe fixed in Cement Concrete 1:2:4 (20mm graded stone aggregate), complete all as specified and as directed.
S&F PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, laid in Floors, complete all as specified and as directed.
S&F PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, fixed to Walls, complete all as specified and as directed.
S&F PVC (SWR) Bend 110mm bore (dia), any radius, jointing with Solvent Cement, complete all as specified and as directed.
S&F PVC (SWR) junction single (single T)equal or unequal of 110 mm bore, with access door complete all as specified and as directed.
S&F PVC (SWR) vent cowl of 110 mm bore, complete all as specified and as directed.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed
Supply and laying Reinforced Concrete Pipes 150mm (internal dia), Class NP-3, laid in Trenches on Concrete Bed, to required Slope, jointed with jute & cement mortar 1:1, complete with collars all specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) as in Concrete Bed to Drain Pipes of 150mm bore (dia), including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M&L for concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested in cement concrete 1:3:6 , type C2 (using 40 mm graded aggregates) for 110mm OD PVC SWR pipes complete all as specified and directed. (NOTE: Cost of earthwork shall be deemed to be included in quoted rate)
M&L Cutting into existing Manholes for Connecting New Drain Pipes of 150mm (Internal dia), Making Good to Pipe and rendering, cutting out existing Benching for and forming Branch Channel (½ Round or ¾ Section) in Cement Concrete 1:2:4 (20mm graded stone aggregate), Smooth Finished and Reforming Benching as required, complete all as specified and as directed.
S&F powder coated (medium thickness of powder coating 50 micron) anodised aluminium frame for door, windows, partitions and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium doors shutters, aluminium section weighing 0.55 Kg/metre including necessary jointing cleats, glazing clips rubber packing handle 2 Nos in each door, hinges, Mortise lock vertical type size 100 mm 4 levers of brass in each door, anodised aluminium snap beading screws etc as per manufactures instruction complete all as specified and directed. (NOTE:- Quoted rate is deemed to be inclusive of the cost of include for anodised aluminium hard ware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames, handle, Mortice Lock etc as described in item. Sheet glass shall be measured seperately)
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, silding type without sash bars, aluminium section weighing 0.55 Kg/metre including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, anodised aluminum fittings such as shinges, handles etc as per manufactures instruction complete all as specified and directed. (NOTE: Quoted rate is deemed to be inclusive of the cost of include for anodised aluminium hard ware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames, handle etc as described in item. Sheet glass shall be measured seperately)
S&F Sheet Glass 4.80 mm thick, frosted (as approved by GE), fixed to Aluminium Windows of size exc 0.50 sqm each pane complete all as specified and directed.
S&F Sheet Glass 5.50 mm thick, plain (as approved by GE), fixed to Aluminium doors of size exc 0.50 sqm each pane complete all as specified and directed.
S&F Door Closer Aluminium (Die cast) body, hydraulically regulated, Designation No. 3, Universal type, suitable for Door Shutters of 851mm to 1000mm in width and of weight between 61.00 to 80.00 Kilogram complete all as specified and directed.
S&F Double Action Floor Spring Hydraulically Regulated made up of minimum 1.25mm thick Aluminium alloy Sheet Foundation Box, Main Body with Stainless Steel Cover, Governing Pivot made of Brass, Other Parts made of Mild Steel heavy duty complete all as specified and as directed.
S&F factory made uPVC white colour Sliding window Three track, area not exceeding 2.00 sqm each, made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed. (NOTE: The unit rate quoted by contractor shall deemed to include all accessories for proper installation and operation of the window. Sheet Glass shall be measured and paid seperately. Net Opening will be measured lor payment purpose.)
S&F Sheet Glass 4.80 mm thick, plain (as approved by GE), fixed to UPVC Windows of size exc 0.50 sqm each pane complete all as specified and directed.
SCHEDULE 'A' PART-II (ELECTRIFICATION WORKS)
M&L concealed Point Wiring with 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 19/20 mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing Sunk GI Terminal Box (1.2mm thick) of suitable size (as required) for mounting MODULAR TYPE Switches, Sockets, Fan Regulators, Sockets, etc with Earth Continuity Wire connected to Common Earth dolly complete all as specified and as directed for the folowing:- (NOTES :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be deemed to be inclusive of the cost of terminal box. Modular cover plate & frame shall be measured and paid seperately (iii) Cost of cutting chases for concealed wiring and making good surfaces with cement plaster and putty shall be deemed to be inclusive in the quoted rates. No claim shall be admissible at a later stage)
for one MODULAR TYPE light / bell / ceiling fan / exhaust fan point controlled by one way switch with 1.50 Sq. mm wire for mains & neutral
for one MODULAR TYPE 5/6 Amps Pin Socket Outlet on the same board, with 1.50 Sq. mm wire for mains & neutral
for one MODULAR TYPE 5/6 Amps socket outlet on independent board, with 1.50 Sq. mm wire for mains & neutral
for one MODULAR TYPE 15-20 Amps socket outlet on independent board, with 2.50 Sq. mm wire for mains & neutral
S&F Modular Switch 1 way 6 A, 1 module complete all as specified and as directed.
S&F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and as directed.
S&F Modular Switch 1 way 16 A, 1 module complete all as specified and as directed.
S&F Modular Socket 6 & 16 A, 2/3 pin combined 2 module complete all as specified and as directed.
S&F Ceiling rose, surface type, three terminals complete all as specified and directed
S&F Modular Fan regulator, 5 step, 120 watt, 2 module, 230 volts, single pole complete all as specified and directed.
Supply and Hanging, ceiling fan, with brushless DC motor, 1200 mm sweep with down rod, canopy, fan blades and accessories and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 1.0 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan complete all as specified and directed. (MAKE : USHA, Model: ENERGIA 32 / CROMPTON GREAVES, Model : ENERGION HS / ORIENT, Model: ECOTECH / PANASONIC, Model: BLDC F-12XDA / HAVELLS, Model: Efficiencia Neo)
S&F exhaust fan 300 mm sweep, 1300 RPM, heavy duty, AC Single Phase 230/240 volts, metal body, with louvers complete with all accessories and connecting up with and including twin core twisted flexible copper conductor cable of size 1.5 sqmm (nominal area) from ceiling rose to fan complete all as specified and directed. (MAKE : HAVELLS, Model: Ventil Air DS / CROMPTON, Model: Transair / USHA, Model: Aero Clean Plus or equivalent model in BAJAJ / ALMONARD / ORIENT) (NOTE : Hole shall be left in brickwork during bldg construction stage and shall be finished properly with cement plaster.
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, 100 lumen/watt, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed.
-ditto- as per Item No. 3.14 but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 100 lumen per watt
-ditto- as per Item No. 3.14 but of 1 X 05 Watt capacity in polycarbonate housing with lumen output not less than 100 lumen per watt
S&F LED Bulkhead fitting 09/10 watt, with IP65 degree of protection and with impact resistance of IK-08, mounted on wall /ceiling connected with insulated unsheathed flexible copper wire of suitable size complete all as specified and directed.
S&F Surface mounted LED luminaire, of size 600 mm x 600 mm, 100 lumen/watt, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED (Cool Day Light) and incl all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed.
Supply, installation, testing and commissioning of wall mounted, air cooled, remote operated, inverter type, split unit air conditioner electric driven, 220 Volts, single phase of capacity 1.5 TR, BEE 4/5 star rated, ISEER as per bureau of energy efficiency specifications > 5.0, rated cooling capacity 18000 BTU with R-32 Refrigerant, copper type condenser (grooved) and Rotary Compressor duly and comprising of the following accessories complete all as specified and directed as under:- (i) Outdoor Unit :- It shall be fitted on platform, chajja, balconies, etc with suitable size nuts & bolts or on walls with suitable powder coated MS brackets/stand along with vibration damping pads and duly connected with suitable size copper tubes and PVC water pipes to the indoor unit. (ii) Indoor unit :- It shall be fixed on inner walls with necessary supports and duly connected with the outdoor unit and necessary electrical connections. Multifunction cordless remote with batteries shall also be supplied with AC unit. NOTES:- 1) Contractor shall ensure that the proposed AC complies with the above specifications. Necessary documents shall be submitted by contractor along with his letter for approval of make of AC.
NOTES TO ITEM NO 3.19 (Contd...):- 2) The indoor/ outdoor unit shall be incorporated with standard sized copper piping covered with foam insulation fixed firmly by clamping and supporting. Foam insultion shall be protected by suitable vinyl tape. A suitable size PVC drain pipe shall be run from the indoor unit to the nearest drain point with U trap at the end which should be fixed firmly by clamping & supporting wherever required. Copper pipes, thermal insulation foam, vinyl tape and PVC water pipe shall be measured and paid separately as "Supply Only". Quoted rate shall be deemed to be inclusive of all other accessories & consumables required for satisfactory installation of ACs.3) Cost of refrigerant, if any required for charging, shall be deemed to be included in the quoted rate. 4) Opening in the wall for taking refrigerant line outside of building shall be provided during bldg construction stage and shall be properly finished. 5) Nuts & bolts of suitable type & size for fixing of indoor & outdoor units shall deemed to be included in the quoted rates. However, MS brackets shall be measured and paid seperately. 6) All parts of Air Conditioner except Compressor shall be guaranteed for satisfactory performance for a period of 12 months from the date of installation or 18 months from the date of receipt of material at site whichever happens to be later. The Compressor of Air Conditioners shall be guaranteed for satisfactory performance for a period of 5 years from date of installation.
Supply only copper tubing, 0.80 mm thick, of size 1/2'' dia along with flare nuts for connection from indoor to outdoor unit of split AC 1.5 TR capacity complete all as specified and directed.
Supply only copper tubing, 0.80 mm thick, of size 1/4'' dia along with flare nuts for connection from indoor to outdoor unit of split AC 1.5 TR capacity complete all as specified and directed.
Supply only 15 mm dia PVC pipe, nylon imbraided for condenser water drainage alongwith necessary Mild Steel Clamps, Screws, nuts & bolts etc complete all as specified and directed.
Supply only foam Insulation, Sleeve type, of Best quality, for refrigerant copper tubing complete all as specified and directed. (NOTE: Length of protected copper tubing shall be measured for payment purpose)
Supply only vinyl adhesive tape, of suitable size & width, for protection of suction line foam insulation complete all as specified and directed. (NOTE: Length of protected copper tubing shall be measured for payment purpose)
Supply and Fixing powder coated metallic stand/brackets, for fixing outdoor units of Split Type Acs of 1.5 TR capacity including drilling holes in walls and fixing with necessary rawl plugs, nuts & bolts etc complete all as specified and directed.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 110 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5%, 4-6 Sec initial delay and of capacity 5 KVA/30 A complete all as specified and directed.
Supplying, assembling and fixing modular AC power unit comprising of 01 No 20 Amps socket and 01 No 32 Amps SP Mini MCB, 3 modules along with GI metallic flush box, cover plate and frame duly concealed in wall and making good surfaces with white cement/putty complete all as specified and directed. NOTE: Quoted rate shall be deemed to include for the cost of MCB, socket, GI flush box, cover plate & frame. Concealed conduit wiring shall be measured separately.
S&F 32 Amps modular motor starter with cover plate & frame, 2 modules along with GI metallic flush box duly concealed in wall complete all as specified and directed. NOTE: Quoted rate shall be deemed to include for the cost of cover plate & frame and GI flush box along with starter. Concealed conduit wiring shall be measured separately.
M&L for concealed sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including PVC conduit (medium grade) of suitable size, including taking down of old Submain wiring any type including batten/ conduit/casing at any indicated situation complete all as specified and directed. (NOTE : (1) Three runs of single core 4.0 sqmm cable & one run of PVC conduit shall be measured as one unit. (2) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage. (3) On completion of the wiring work, the contractor shall fill and finish the chases with cement mortar 1:6 and finsihed flush with the adjacent surfaces. Rate quoted by the contractor shall be deemed to include for the above aspect and no claim shall be entertained at a later stage.
M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including PVC CASING CAPPING (medium grade) of suitable size complete all as specified and directed. (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit.
S&F SPN DB, IP 43 protection, double door, 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed.
S&F Sheet Metal Enclosure, Single Door, 2 way with provision to mount MCBs complete all as specified and as directed.
S&F Sheet Metal Enclosure, Single Pole with a 2-Pin and Earth Plug and Socket with provision to mount MCB, 32 Amps, 240 volts and connecting up complete all as specified and as directed.
NOTE FOR ITEM NO. 3.32 to 3.34 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured and paid seperately. (2) Quoted rate is deemed to be inclusive of blanking plate for blank slots after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
S&F MCB, 'C' Curve, SPN, 40-63 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'C' Curve, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'C' Curve, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
Supply, laying, jointing and testing, fixing to wall using clamps/ pole / floor or in air or passing through pipes / ducts / road / path / drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened, PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 4 core 16 sqmm confirming to IS-7098 Part-1 and its latest amendments complete all as specified and as directed. NOTE: Earthwork, sand cushioning & brick protection shall be measured and paid seperately.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, laid perpendicular to the cable for Cable Protection, complete all as specified and as directed.
S&F laying Galvanised Steel Tubing Pipe 40mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles or walls with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (up to 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
shiv shanker enterprises (BID ID -3365207)
M/S Aggarwal construction co. (BID ID -3373542)
Ajay Enterprises (BID ID -3366053)
M/s Shree Bala Ji Construction Company (BID ID -3365292)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .