Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.3 L+₹62,950 (3.57%)Rejected-Finance H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹21.2 L+₹3.5 L (20.0%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹22.2 L+₹4.6 L (25.8%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹22.8 L+₹5.1 L (29.0%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
15 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR/ REPLACEMENT OF LT OH LINE, LT UG CABLES, LT PANEL AND OTHER CONNECTED ITEMS AT BHALRA MIL STN UNDER GE (I) 873 EWS
2020_MES_378093_1
NIT-45 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BHADERWAH
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE (I) 873 EWS
₹66,000
Yes
10 Nov 2020
16 Sept 2020
20 Oct 2020
16 Sept 2020
15 Oct 2020
1 Oct 2020
60 days
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Cutting of existing road / hard standing for laying of GI protection pipe for cables, depth of trench not exceeding 0.75mtr, width of trench not exceeding 1.0mtr and making good by returning filling in (by well ramming and watering of soil in layers not exceeding 25cms), provision of 150mm thick sub base, 150mm thick WBM and therafter 150mm thick PCC 1:2:4 type B-1 (using 20mm graded agggregate) including removal of surplus spoil to a distance not exceeding 50mtrs complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Laying only serviceable bricks as mechanical protection to underground cable with width equal to length of bricks, width of brick perpendicular to length of cable, all as specified and as directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Steel Tubular swaged poles type 410 SP-31 (9.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable pole all as specified and as directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) all as specified and as directed.
Galvanised Guard wire / Cradles / Stay wires complete as required at site all as specified and directed.
Anti-climbing device spike type fabricated out of flat iron 40 x 6mm and MS bars (Round / Square / Flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole and painting one primer coat, one under coat and one finishing coat of paint including taking down old unserviceable anti climbing device complete all as specified and directed.
Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 20x15 cm size including taking down old unserviceable Danger notice plate all as specified and directed
Pin type porcelain in replacement, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Shackle type insulator, porcelain, in replacement, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nut, 75mm height, 90mm dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
Stay assembly complete with accessories as shown in Electrical Plate No.1 of SSR 2009 Part-I using stay rod of 16 mm dia, stay bow 14 mm dia, 400 mm long, MS Plate of size 300 x 300 mm x 6mm thick, stay GI wire 7/4mm dia (loop type insulator stay clamp, excavation and concrete shall be measured and paid separately) complete all as specified and directed.
Loop type insulator, vitreous white, brown or green large size with overall dimension 90 x 140mm with clearance of hole 16mm complete all as specified and directed.
Lightning arrestor for outdoor use, non-liner resistor type, horn gap and choking coil, maximum working pressure 1100 volts including taking down old unserviceable arrestor, complete all as specified and directed.
Lightning arrestor expulsion type complete with all fittings, 30 kilo amp discharge capacity, distribution class including taking down old unserviceable arrestor, complete all as specified and directed.
1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 6 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed.
1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 10 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed.
1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 16 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed.
Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 2.5 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including conduit and accessories) with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 1.5 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Two run of 2.5 Sqmm wire, one run of 1.5 Sqmm wire and one run of PVC conduit shall be considered as one unit length.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 10 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 25 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 35 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 70 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 95 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 120 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 150 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 185 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
Cable jointing kit for 1.1 KV (earthed) grade cable for straight through joint, heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25-50 Sqmm, indoor/ outdoor type complete all as specified and as directed.
Cable jointing kit for 1.1 KV (earthed) grade cable for straight through joint, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 - 95 Sqmm, indoor/ outdoor type complete all as specified and as directed.
Cable jointing kit for 1.1 KV (earthed) grade cable for straight through joint, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120-150 Sqmm, indoor/ outdoor type complete all as specified and as directed.
Cable jointing kit for 1.1 KV (earthed) grade cable for straight through joint, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185-240 Sqmm, indoor/ outdoor type complete all as specified and as directed.
Synthetic Insulation Mat in replacement, chequered type up to 11 KV rating as per ISI specification of size 2.0m x 1.0m x 12mm thick suitable for LT Panels, Transformers or DG Sets, complete all as directed by Engr-in-Charge.
Air termination, single pointed aluminum rod 12 mm dia and 300 mm long, including taking down old all as specified and directed
Test point block of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws complete all as specified and as directed.
Aluminium strip 25x3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground including taking down old unserviceable earthing strip complete all as specified and directed
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 25 x 4 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised wire of 4mm dia to connect earthpit to electrical equipment room including taking down old unserviceable earthing cnductor complete all as specified and directed
Galvanised Iron earthing strip 32 x 6 mm from earth test point to electrical equipment including taking down old unserviceable earthing strip complete all as specified and directed
MCCB 350 Amps, breaking capacity 36 KA, 4 pole, 415V, adjustable type including taking down old unserviceable MCCB complete all as specified and as directed.
MCCB 250 Amps, breaking capacity 36 KA, 4 pole 415V, adjustable type including taking down old unserviceable MCCB complete all as specified and as directed.
MCCB 200 Amps, breaking capacity 36 KA, 4 pole, 415V, adjustable type including taking down old unserviceable MCCB complete all as specified and as directed.
MCCB 160 Amps, breaking capacity 36 KA, 4 pole, 415V, adjustable type including taking down old unserviceable MCCB complete all as specified and as directed.
MCCB 160 Amps, breaking capacity 16 KA, 3 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and as directed.
MCCB 125 Amps, breaking capacity 16 KA, 4 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and as directed.
MCCB 125 Amps, breaking capacity 16 KA, 3 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and as directed.
MCCB 100 Amps, breaking capacity 16 KA, 4 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and as directed.
MCCB 100 Amps, breaking capacity 16 KA, 3 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and as directed.
MCCB 63 Amps, breaking capacity 16 KA, 4 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and as directed.
MCCB 63 Amps, breaking capacity 16 KA, 3 Pole, 415V, fixed type including taking down old unserviceable MCCB complete all as specified and as directed. Makes of Serial Item No '51' to '61' : L&T / Legrand / Schneider / Havells / ABB
Painting of steel tubular pole 9 metre long with cross arms with one coat of aluminium paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all rusted surface and painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface of pole and cross arms structure over one coat of primer and marking of MES No complete all as specified and as directed.
Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 Volt of capacity 25 KVAR complete all as specified and as directed.
Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 Volt of capacity 20 KVAR complete all as specified and as directed.
Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 volt of capacity 15 KVAR complete all as specified and as directed.
Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 volt of capacity 10 KVAR complete all as specified and as directed.
Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 volt of capacity 5 KVAR complete all as specified and as directed.
ON LOAD Change Over Switch 415 volt in sheet metal enclosure Four Pole of capacity 63 Amps complete all as specified and directed
ON LOAD Change Over Switch 415 volt in sheet metal enclosure Four Pole of capacity 160 Amps complete all as specified and directed
ON LOAD Change Over Switch 415 volt in sheet metal enclosure Four Pole of capacity 200 Amps complete all as specified and directed
ON LOAD Change Over Switch 415 volt in sheet metal enclosure Four Pole of capacity 400 Amps complete all as specified and directed
Galvanised Iron tubing medium grade, 50 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Galvanised Iron tubing medium grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Aluminium cable lugs / thimbles suitable for cable of size 16 to 35 Sqmm complete all as specified and as directed.
Aluminium cable lugs / thimbles suitable for cable of size 50 to 95 Sqmm complete all as specified and as directed.
Aluminium cable lugs / thimbles suitable for cable of size 120 to 240mm complete all as specified and as directed.
Supplying, installing, designing, testing and commissioning of LT Outdoor type Panel Board, Factory made, (Cubical Kiosk type), weather, dust and vermin proof, CPRI approved with locking arrangement made out of CRCA sheet 3.15 mm thick with suitable size of channel for base complete with copper bus bar of 400 Amps rated with cable gland of suitable size and in adequate Nos, cabinet for housing mounting switch, disconnection fuse unit, metering equipments, prewired with suitable size of copper conductor and duly powder coated in Siemens grey colour mounted on PCC platform of PCC 1:2:4 type B-1 on angle iron frame which is made out of 50 x 50 x 6mm thick angle iron duly marked the incoming outgoing controls, complete all as specified and directed and comprising of the following :-
(i) Incoming (a) MCCB 160 Amps, breaking capacity 25 KA, FP, 415V (Adjustable Thermal and Magnetic setting) - 01 No(ii) Outgoing (a) MCCB 100 Amps, breaking capacity 16 KA, FP, 415V (Adjustable Thermal and Magnetic setting)- 02 Nos(b) MCCB 63 Amps, breaking capacity 16 KA, FP, 415V (Adjustable Thermal and Magnetic setting)- 01 No (c) Three Phase Multifunctional Digital Meter for measuring Voltage, Amperes, Frequency & Power Factor - 01 No (d) Complete control panel wiring with suitable size stranded copper conductor alongwith one set of indicator lamp for RYB for incoming and outgoing feeders.
(e) Lock pedestal - 01 No Make of Panel : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear Make of MCCB : L&T / Legrand / Schneider / Havells Make of Voltmeter / Ammeter / Multifunction Meter : SECURE / L&T (RISHAB) / C&S ELECTRIC / MECO
Supplying, installing, designing, testing and commissioning of LT Outdoor type Panel Board, Factory made, (Cubical Kiosk type), weather, dust and vermin proof, CPRI approved with locking arrangement made out of CRCA sheet 3.15 mm thick with suitable size of channel for base complete with copper bus bar of 400 Amps rated with cable gland of suitable size and in adequate Nos, cabinet for housing mounting switch, disconnection fuse unit, metering equipments, prewired with suitable size of copper conductor and duly powder coated in Siemens grey colour mounted on PCC platform of PCC 1:2:4 type B-1 on angle iron frame which is made out of 50 x 50 x 6mm thick angle iron duly marked the incoming outgoing controls, complete all as specified and directed and comprising of the following :-
(i) Incoming (a) MCCB 100 Amps, breaking capacity 25 KA, FP, 415V (Adjustable Thermal and Magnetic setting) - 01 No (ii) Outgoing (a) MCCB 100 Amps, breaking capacity 16 KA, FP, 415V (Adjustable Thermal and Magnetic setting)- 01 Nos (b) MCCB 63 Amps, breaking capacity 16 KA, FP, 415V (Adjustable Thermal and Magnetic setting)- 01 No (c) Three Phase Multifunctional Digital Meter for measuring Voltage, Amperes, Frequency & Power Factor - 01 No (d) Complete control panel wiring with suitable size stranded copper conductor alongwith one set of indicator lamp for RYB for incoming and outgoing feeders.
(e) Lock pedestal - 01 No Make of Panel : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear Make of MCCB : L&T / Legrand / Schneider / Havells Make of Voltmeter / Ammeter / Multifunction Meter : SECURE / L&T (RISHAB) / C&S ELECTRIC / MECO
M/S BALI CONSTRUCTIONS
SWASTIK TRADERS
SUMEET TRADING CORPORATION
M/S NARAYAN CONSTRUCTION
Bidder Name
M/S BALI CONSTRUCTIONS
SWASTIK TRADERS
SUMEET TRADING CORPORATION
M/S NARAYAN CONSTRUCTION
RAVI KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .