Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC | ₹7.9 L | L1 | Accepted-AOC L1 Accepted |
| 2 | L2₹10.8 L+₹2.9 L (36.9%)Rejected-Finance | ₹10.8 L+₹2.9 L (36.9%) | L2 | Rejected-Finance Other than L1 after deducting sch of credit of Rs 103540.00 |
| 3 | L3₹11.3 L+₹3.4 L (43.7%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | ₹11.3 L+₹3.4 L (43.7%) | L3 | Rejected-Finance Other than L1 after deducting sch of credit of Rs 103540.00 |
| 4 | L4₹11.5 L+₹3.6 L (46.2%)Rejected-Finance | ₹11.5 L+₹3.6 L (46.2%) | L4 | Rejected-Finance Other than L1 after deducting sch of credit of Rs 103540.00 |
| 5 | L5₹16.8 L+₹8.9 L (113.6%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | ₹16.8 L+₹8.9 L (113.6%) | L5 | Rejected-Finance Other than L1 after deducting sch of credit of Rs 103540.00 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
29 Jun 2021, 6:00 pmClosed
GE North Akhnoor
GE North Akhnoor C/O 56 APO
REPAIR AND MAINTENANCE OVERHAULING TO CEILING FAN GEYSERS EXHAUST FAN AND MISC EM SERVICES AT AKHNOOR UNDER GE NORTH AKHNOOR
2021_MES_447535_1
GE(N)/AKH-22/2021-22
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
Class E cat b i
8 documents required · 8 mandatory
₹500
Yes
GE North Akhnoor
₹30,000
Yes
21 Sept 2021
1 Jun 2021
1 Jul 2021
1 Jun 2021
29 Jun 2021
15 Jun 2021
Amount
M&L for taking down of ceiling fan of size 1200/1400mm for safety checking by replacing defective parts/painting/rewinding and re-fixing the ceiling fan after repairs,all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod etc.shall be made as directed by the Engineer-in-Charge which will be measured and paid separately under respective items as Supply only. However, parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement are deemed to be inclusive in quoted rate all as directed. Note for item No 1: The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 1:-
(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work. (c) Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation. (d) The entire job will be carried out in Akhnoor station and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format directed by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs. (e) Maitenance of documents ie complaint slip/complaint register & other stationery required shall be of contractor's responsibility. (f) Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor's responsibility. (g) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department. (h) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. (k) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. (l) The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
Supply only rotor of ceiling fan of any size
Supply only fan canopies for ceiling fan size of 1200mm/1400mm
Supply only gun metal bush of suitable size for ceiling fan 1200mm /1400 mm sweep
Supply only fan bearing suitable for ceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF
Supply only down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm
Supply only 'U' clamp for hanging ceiling fan with all nuts, bolts and washers.
Supply only outer body of ceiling fan of any size
Supply only blades (made of aluminum) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specified and directed.
Supply only safety pins 40mm to 50mm long with nuts and bolt with washers for ceiling fan of size 1200/1400mm
Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed.
Supply only blades (made of aluminum) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
M&L painting the ceiling fan 1200mm /1400 mm sweep with one coat of syntetic enamel paint as existing colour and writing the MES No- as directed by Engr in Charge.(Taking down of fan, and re-hanging shall be measured under item No.1.) Note:- Painting of ceiling fan shall be done inside MES complex only.
Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule. (iii)taking down of fan,and re hanging measured under item No. 1 seperately.
Material and labour for winding of ceiling fan motor 1400 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule. (iii)taking down of fan,and re hanging measured under item No. 1 seperately.
Supply and fixing in replacement of unserviceable energy efficeint Ceiling fan 1200 mm sweep, energy efficient ISI mark with 5 star rating (BLDC) 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells cat Part No. ES Neo or equivalent in Bajaj/ Orient./Halonix Note:- (a) The contractor shall given a written guarantee of minimum two years from completion of work. (b) Old Unserviceable ceiling fan shall be deposited to MES store yard.
Taking down of exhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) are deemed to be inclusive in quoted rate all as specified and as directed. (Note:- Repair, rewinding, over hauling and materials to be replaced are measured seperately.) Note: The following shall be deemed to be inclusive in the unit quoted rate :- (a) In each job checking of functioning of fan including its connections, cleaning of fan, greasing of fan, mechanical check i.e. tightening of loose screw , nuts, bolts, are inclusive in unit quoted rate. (b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
(c) Defected unserviceable part like fan bush, bearing etc will be paid under respective item here-in-after as supply only through proper documentation. (d) The entire job will be carried out in Akhnoor and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format directed by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs. (e) Necessary complaint slip/complaint register & other stationery required shall be contractor responsibility. (f) Necessary T&P such as ladder, helper shall be contractor responsibility. (g) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department. (h) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. (k) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. (l) The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
Material and labour for winding of Exhuast fan 450 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule.
Description all as per Srl item No 21 here-in-above but 300 mm sweep
Description all as per Srl item No 21 here in above but 230 mm sweep
Supply only fan bush of suitable size for exhaust fan of the any sweep
Supply only 4 mfd capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha
Supply only metal louvers of suitable size for exhaust fan of the 450mm sweep
Supply only fan bearing of suitable size for exhaust fan of 450mm sweep including greasing.
Supply only 3.15 mfd capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha
Supply only metal louvers of suitable size for exhaust fan of the 300mm sweep
Supply only fan bearing of suitable size for exhaust fan of 300mm sweep including greasing.
Supply only 2.5 mfd capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha
Supply only metal louvers of suitable size for exhaust fan of the 230mm sweep
M&L painting the exhaust fan of 450mm sweep with one coat of syntetic enamel paint as exiting colour and writing the MES No and return to MES storeyard /user unit from the work shop as directed by Engr in Charge. Note:- Painting of Exaust fan shall be done inside MES complex only.
All as per item No 33 here-in-above but 300 mm sweep
All as per item No 33 here-in-above but 230 mm sweep
S&F domestic Exhaust Fans for kitchen, 300 mm sweep, 230 volt square type, heavy duty, 1400 RPM, corrosion less mild steel body of motor, plastic/ fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, including necessary cutting, making holes on stone/brick walls where required, fixing arrangement with MS pipe 350 mm dia of required length for protect deshape of stone masonery, suitable hold fast with necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make- havells model-Ventil Air-DB or equivalent in bajaj, Almonard. Note:- Old Unserviceable domestic exhaust fan shall be deposited to MES store yard.
S&F Exhaust fan 200 mm sweep 230 volt square type, heavy duty with louvers of PVC body including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells Cat No Ventil DX-WH/BLK or equivalent in bajaj, Crompton Greaves etc. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Taking down of wall mounted fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling . (Note:- Repair, rewinding, over hauling and materials to be replaced are measured seperately.)
Supply only fan bearing of suitable size for wall mounted fan of 630mm sweep make-: SKF/TATA/NBC
Description all as per Sl item No 39 here in above but 400 mm sweep.
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and apply 2 coats of white wash/distemper to match with the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
M&L for point wiring for 5 Amp switch /sockets independent using approved colour coding as per IS with 1.5 sqmm single core PVC insulated, unsheathed FRLS cable 1100 volts grade ISI 694 marked, multi stranded with copper conductor drawn through and incl concealed PVC conduit heavy duty, 19/20mm dia, ISI marked with accessories in wall/roof/ceiling etc incl terminal boxes fabricated with 1.6mm MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of conduit : Plaza/Supreme/Finolex Make of wire : Plaza/Havells/Poly Cab Note:- (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely. (b) Connection of wire with switch, socket shall be done through copper thimble (lugs) only.
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors/concealed along with 1 run of 2.5 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of Casing capping -Poly Cab/Modi/ Presto Plast Make of Cable : Plaza/Polycab/Havells Note: 2 runs of 4 sqmm cable along with one run of 2.5 sqmm cable for earth conductor alongwith suitable size PVC casing capping/Pipe shall be measured as one length.
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors/concealed along with 1 runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of Casing capping -Poly Cab/Modi/ Presto Plast Make of Cable : Plaza/Polycab/Havells Note: 2 runs of 6 sqmm cable along with one run of 4 sqmm cable for earth conductor alongwith suitable size PVC casing capping/Pipe shall be measured as one length.
S&F in replacement factory made powder coated distribution board SP & N 8 way, including bus bar, Neutral bar, standard DIN rail, earth bar acomplete all as specified and conforming to IS: 8623 all as specified. Make/Model : Legrand/ Schnieder/ ABB.
Taking down and dismantling geyser of any make and cap 25/50 ltrs & taking out water inlet outlet assly, removing glass wool and taking out the inner tank, descaling the assembly and tank , detecting the leakage, welding / brazing the defected part , repacking the glass wool and refixing the same after making it funcional including replacement of worn out nuts bolts washer etc complete all as specified and directed. Note: Cost of material and labour for providing new items shall be measured under relevant items of sch A.
Supply and fixing in replacement of water inlet and outlet assembly of any make as required at site with rubber gasket suitable for geyser of 25 ltrs capacity electric driven water storage heater with provn of housing for thermostat assembly, heating element fixing arrangement nuts bolts and washers etc. complete all as specified and directed .
Supply and fixing in replacement of water inlet and outlet assembly of any make as required at site with rubber gasket suitable for geyser of 50 ltrs capacity electric driven water storage heater with provn of housing for thermostat assembly, heating element fixing arrangement nuts bolts and washers etc. complete all as specified and directed .
Supply & fixing in replacement thermostat switch for electric water heater storage type of cap 25/ 50 ltr, 230 volts of any make of geyser.
S&F in replacement heating element with triangular base ISI marked, single phase, 230 volt, cap 1.5 KW complete all as specified and directed.
S&F in replacement heating element with round base,ISI marked single phase, 230 volt, capacity 1.5 KW all as specified and directed.
S&F for replacement heating element with triangular base ISI marked, single phase, 230 volt, cap 2 KW all as specified and directed.
S&F for replacement heating element with round base ISI marked, single phase, 230 volt, cap 2 KW all as specified and directed..
Supply and fixing in replacement pressure release valve conforming to relevant IS, 15mm bore suitable for fixing with GI pipe/tubing 15mm bore complete all as specified and directed.
Supply and fixing in replacement of heavy duty PVC connection nylon threaded 450mm large (18”) 15mm bore including brass nuts, rubber washers complete on both ends.
Supply and fixing in replacement of indicator lamps round/rectangular type 230 volt AC suitable for geyser of any capacity including providing electric connections complete all as specified & directed.
Supply & fixing in replacement water storage inner tank of SS material for 25 ltrs capacity geyser, with provn for fixing 15mm dia galvanized air release valve all as specified and directed.
Supply & fixing in replacement water storage inner tank of SS material for 50 ltrs capacity geyser, with provn for fixing 15mm dia galvanized air release valve all as specified and directed.
Supply & fixing in replacement PVC connection pipe with nuts, washers and bolts end of size 450mm long all as specified and directed.
Supply & fixing in replacement MCB SPN 20 Amps 240 volts , rupturing cap 10 KA, 'C' series all as specified and directed.
Supply & fixing in replacement MCB DB 2 way complete with fixing accessories all as specified and directed. Make Havells,Indoasian, Schnieder.
Supply & fixing in replacement thermal cut out Bimetallic disc type with snap action switch, with operation temperautre below the boiling point i.e. 90+ 6˚C with manual reset knob for Geyser.
Supply and fixing in replacement plug top 15 Amps 3 pins all as specified and directed. Make Havells REO, Schnieder, Indoasian
Material and labour for painting of geyser of cap 25/ 50 ltr complete with superior quality synthetic enamel white paint by spray painting after scraping old paint and making surface clean all as specified and directed. Note: contractor has make an arrangement for spray painting within premises of Garrison Engineer as directed and specified by Engr -in-charge and rate quoted shall be deemed to include to remove, transport Geysers from bldgs to specified loc for cleaning and painting and reconnected at same place after doing needful.
S&F socket residual current device (SRCD) DBOXx in steel enclosure with MCB SPN 16 Amp and plug top 15/16 Amp Cat No:DHDDCDP025201603 Make Havells or its equivalent in make of Indoasian/Schneider
Taking down UNSV PVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size 25mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP25SMIV Make Anchor or equivalent in Kalinga, Supreme
Taking down UNSV PVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size 32 mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP32SMIV Make Anchor or equivalent in Kalinga, Supreme
Taking down UNSV PVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size 40 mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP40SMIV Make Anchor or equivalent in Kalinga, Supreme
Taking down unsv and M&L for all in one integrated solar light for bldg having day light sensor monitoring sunset auto start sensor control having input voltage 220 -240 volt capacity 30 watt inbuilt li battery made up of die casting aluminium all as specified and directed Cat part No ALSSL30 make Asco or equivalent in Havells, Bajaj
VISHAL CONSTRUCTION
R K BUILDERS
Jiwan Singh
M/S Chib Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .