| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | ₹24.0 L Quoted ₹24.5 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹26.4 L+₹1.9 L (7.82%)Rejected-AOC | ₹26.4 L+₹1.9 L (7.82%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹27.9 L+₹3.4 L (14.0%)Rejected-AOC | ₹27.9 L+₹3.4 L (14.0%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹29.0 L+₹4.5 L (18.4%)Rejected-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹29.0 L+₹4.5 L (18.4%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹39.4 L+₹15.0 L (61.3%)Rejected-AOC | ₹39.4 L+₹15.0 L (61.3%) | L5 | Rejected-AOC Rejected |
Tender Value
₹25.0 L
EMD Value
₹50,000
Closing Date
15 Jun 2022, 5:00 pmClosed
GARRISON ENGINEER GOMANATAK
GARRISON ENGINEER GOMANTAK VASCO DA GAMA PIN 403802
Repair Maintenance of UG Cable Panel etc including preventive Maintenance of Electrical accessories in Gomantak NIH 2W Det NCB under GE Gomantak Vasco
2022_MES_520397_2
8435/E8
Open Tender
Support/Maintenance Service
Item Rate
270 days
VASCO DA GAMA
Refer tender documents
8 documents required · 8 mandatory
₹500
GE GOMANTAK
₹50,000
Yes
7 Jul 2022
21 May 2022
16 Jun 2022
21 May 2022
15 Jun 2022
31 May 2022
Amount
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth for Laying of UG cable getting out in hard/dense soil complete all as specified.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth for Laying of UG cable getting out soft disintegrated rock complete all as specified.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil or soft rock.
Removal of surplus soil/ rock to a distance not exceeding 50 m and depositing where directed by Engr-in-charge.
Supply, Laying, joining & testing LT XLPE Insulated & sheathed armoured electric cables with multistranded aluminium conductor cable 1100 volts grade, laid in trenches/ ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes & aluminium lugs for connection for following cross- sectional areas all as specified and directed.
(a) 25 Sqmm 3.5 Core
(b) 35 Sqmm 3.5 Core
(c) 50 Sqmm 3.5 Core
(d) 70 Sqmm 3.5 Core
(e) 95 Sqmm 3.5 Core
(f) 120 Sqmm 3.5 Core
(g) 185 Sqmm 3.5 Core
(h) 240 Sqmm 3.5 Core
M&L for fixing GI tubing light grade use for the protection of cable all as specified and directed by Engr-in-Charge.
(a) 40 mm dia
(b) 50 mm dia
(c) 80 mm dia
(d) 100mm dia
Supply and fix for DWC high density polyethylene pipes having outer side wall corrugated and inner surface plain confirming to IS 14930 (Part-I & II) for protection of underground cable laid in trenches/floor/fixed on pole/wall including all fittings(coupler) and clamps as required complete all as specified and directed. following inner dia sizes of pipes:-
(a) 38/40 mm dia
(b) 50 mm dia
(c) 75 mm dia
M & L Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 to 50 sqmm including dismantling old burnt cable joint termination.
M & L Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm including dismantling old burnt cable joint termination.
M & L Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 to 240 sqmm including dismantling old burnt cable joint termination.
M&L for cross arm bracing support to clamps and back plate fabricated from structural steel section like angles channels flat etc including nuts bolts and washers welding bending cold or hot drilling holes for bolts if any shape and size and incl applying two coats of aluminium paint over one coat of red oxide primer including dismantling of old cross arms and all as directed by Engr-in-charge.
Supply and installation of LT aluminium busbar suitable for 600 amps capacity, weather, dust and vermin proof (out door type) CPRI approved factory made suitable for operation on 1100 volts 3 phase, 4wire, 50 Hz AC electric supply of size 1mx0.6mx0.5m , externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3.15 mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side including Aluminium busbar of suiatble size for 600 amps capacity , fixing on angle iron size of 50x50x6mm (Ht of legs of Panel should not be less than 60cm) including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :- (i) MCCB 400 Amps, 4 Pole, 36 kA,Ics = 100% of Icu, Adjustable thermal and fixed magnetic setting - 01 No (Incoming). (ii) S&F Digital Ammeter with CT suitable for three phase-01 No (iii) S&F Digital Voltmeter suitable for 3 phase . (iv) Indicators with neon lamp with RYB shade,240 volts 50 c/s of suitable capacity resistance - 01 set. (v) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot Make of MCCB L&T/Havells/Legrand/Schneider (vi) Making 08 Nos Holes (size 240sqmm) at the bottom ot the panel for outgoing cables.
M & L for earthing complete with steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI earth strip 25x4mm by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length, provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts, bolts, earthing shall be done all as per shown electrical plate No 3 of SSR part 1 Including neccessary excavation in soft disintergrated rock and provision of 15mm dia pipe with funnel, PCC earth chamber of 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr-in-Charge.
Supply and fix Hot dip Galvanized Perforated cable tray of 14 SWG ,size 50 mm (h) x 150 mm (w) complete with nuts bolts washers and including all accessories for mounting and supporting the cable tray system & coupler for Raceway of suitable size ,cable clamp complete all as specified & directed.Note:- No sch of credit it is used for improvement and proper laying of existing cables fixed on wall.
Supply and fix Hot dip Galvanized Perforated cable tray of 14 SWG ,size 50 mm (h) x 200 mm (w) complete with nuts bolts washers and including all accessories for mounting and supporting the cable tray system & coupler for Raceway of suitable size ,cable clamp complete all as specified & directed.Note:- No sch of credit it is used for improvement and proper laying of existing cables fixed on wall.
Supply and fix Hot dip Galvanized Perforated cable tray of 14 SWG ,size 50 mm (h) x 300 mm (w) complete with nuts bolts washers and including all accessories for mounting and supporting the cable tray system & coupler for Raceway of suitable size ,cable clamp complete all as specified & directed.Note:- No sch of credit it is used for improvement and proper laying of existing cables fixed on wall.
Taking up exisiting 1.1 KV grade XLPE cable of any cross section area and any size by disconnecting from LT Panel,DBs from wall (from any height),floor without damaging it to re-use the same by re-arranging it as per site requirement complete all as directed by Engr-in-Charge.
Re-laying 1.1 KV grade XLPE cable of any cross section area and size on cable tray and making electrical connections icnluding lugs etc complete all as directed by Engr-in-Charge.
Supply , Install & testing of CPRI approved OEM main LT panel outdoor type made of modular polycarbonate thermoplastic enclosures of size 1400 X 2485 X 795 mm including MCCB , indicating lamp and other accessories which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4; The panel should be anti acid and anti corrosive .Degree of protection against mechanical load IK 08 (5 joule) in accordance with IEC 62262. MS Channel of size 40x40x6mm . The manufacture shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The panel should have bottom cable entry with MS legs of not less than 60cm height including necessary earth/PCC work . The manufacture shall submit a copy of TEST REPORT of board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The LT panel shall include the following:- Incomer -250A FP 25KA MCCB -1 No 250A FP ,25KA,Onload changeover-01 No. Outgoing – 125A FP 25KA MCCB – 02 No. 63A FP 25KA MCCB-03 Nos LED RYB INDICATING LAMP, AMETER with CTs, VOLTMETER Make - Hensel / Schneider./Sintex/National
M/s Gayatri Contruction Co.
JINTECH
M/S jvsr constructions
AATREYA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .