GE AF TA GWALIOR
GE AF TA GWALIOR
CERTAIN ESSENTIAL REPAIR TO E/M SERVICES AND MISC WORKS UNDER GE (AF) TECH AREA AT AF STATION GWALIOR
2020_MES_377807_1
8900/1267/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF TA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TA GWALIOR
₹28,000
Yes
26 Nov 2020
15 Sept 2020
17 Oct 2020
15 Sept 2020
13 Oct 2020
29 Sept 2020
60 days
Amount
Disconnecting and taking out old existing unserviceable voltmeter of any description and in any position and supply, fixing, connecting, testing and commissioning of 1 phase digital electronic voltmeter class I, any range matching suitable for LT 220 Volts 50Hz AC supply, flush pattern, square type, 72mm x 72 mm with adopter approved make out of make given in Apendix 'B' to PS complete all as specified and directed.
Disconnecting and taking out old existing unserviceable current transformers of 100/5 Amp ratio of any description and in any position and supply, fixing, connecting, testing and commissioning of test resin cast tap wound current transformer of rating 100/5 Amps on stabillizer and making connections of secondary terminals to ammeter complete all as specified and directed. Make:- As approved out of make given in Apendix 'B' to PS
Disconnecting and taking out old existing unserviceable current transformers of 250/5 Amp ratio of any description and in any position and supply, fixing, connecting, testing and commissioning of test resin cast tap wound current transformer of rating 250/5 Amps on stabillizer and making connections of secondary terminals to ammeter complete all as specified and directed. Make:- As approved out of make given in Apendix 'B' to PS
Disconnecting and taking out old existing unserviceable current transformers of 400/5 Amp ratio of any description and in any position and supply, fixing, connecting, testing and commissioning of test resin cast tap wound current transformer of rating 400/5 Amps on stabillizer and making connections of secondary terminals to ammeter complete all as specified and directed. Make:- As approved out of make given in Apendix 'B' to PS
Disconnecting and taking out old existing unserviceable Phase indicator lamps and supply, fixing, connecting and, testing LED type Phase indicator lamp with showing red, yellow and green colours fixed to monitor on stabillizer suitable for 240 Volts AC supply and making connections with using suitable size copper cables wires and lugs complete all as specified and directed. Make:- As approved out of make given in Apendix 'B' to PS
Disconnecting existing LT over heated or burnt cable terminal at existing stabillizer, cutting out over heated / burnt / unserviceable portion of cable, stretching / opening cable to suitable required length from available rings etc. and fixing and connecting the cable in position properly by providing suitable new aluminium lugs and suitable GI nuts, bolts & washers including excavation & earth work etc. complete all as specified and directed for the following sizes of cables :- Note:- Any deficiency in cable shall be rectified
35 Sqmm to 50 Sqmm cable of any core
70 Sqmm to 120Sqmm 3.5 Core
180 Sqmm to 240 Sqmm 3.5 Core
Taking down old unserviceable change over switches/ SFUs /MCCBs/Contactors of any description and type complete all as specified and directed.
Supply and fixing off load changeover switch 315/320 Amps 4 pole, 415 Volts in sheet steel enclosure complete all as specified and directed.
Supply and fixing off load changeover switch 400 Amps 4 pole, 415 Volts in sheet steel enclosure complete all as specified and directed.
Supply and fixing onload change over switch 4 pole 320/315 A, 415 Volts in sheet steel enclosure complete all as specified and directed.
Supply and fixing onload change over switch 4 pole 400A, 415 Volts in sheet steel enclosure complete all as specified and directed.
Supply and fixing MCCB 4 Pole, 415V, 315/320 Amps, 36/35 KA with extendable terminals complete all as specified and directed.
Supply and fixing Spreader Terminals suitable for 4 pole MCCB complete all as specified and directed.
Disconnecting & taking out the non-functional voltage stabilizer of any description and in any position & strip opening for servicing of Servo operated oil cooled Voltage Stabilizer of 300 KVA to 400 KVA , 3 Phase , 50Hz , (MAKE :- Blue Line/AE/Volina/Bluebird and other existing make), taking out unserviceable/defective wiring & parts, cleaning and servicing complete including replacement of unserviceable parts complete, draining-out of transformer oil either for filtration/replacement, replacement of unserviceable wiring with new copper wire cable of existing size, reassembling ,connecting and testingall as directed by Eng-in-Charge complete all as specified and directed by Engineer-in-Charge Notes :- (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch ‘A’ as supply only but fixing of the parts replaced/repaired is deemed to be included in this item. (ii) Transformer oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly all as directed by the Engineer-in-Charge. (iii) Dehydration/filtration of old drained out transformer oil and its filling shall be measured and paid for separately under appropriate item of Schedule `A' (iv) Fresh transformer oil, if any required, to make up the oil levels, shall be measured & paid separately under appropriate item of this Sch
All as per item No.17 but servicing of voltage stabilizer of 200 KVA to 250 KVA Servo Operated Voltage Stabilizer oil Cooled (Make:- Blue Line/AE/Volina/Bluebird and other existing make/) --do— (Notes for Sch`A’ item No 17 above shall also be applicable to this item)
All as per item No. 17 but servicing of voltage stabilizer of 100 KVA to 175 KVA Servo Operated Voltage Stabilizer oil Cooled (Make:- Blue Line/AE/Volina/Bluebird and other existing make) --do— (Notes for Sch`A’ item No 17 above shall also be applicable to this item)
All as per item No. 17 but servicing of voltage stabilizer of 50 to 75 KVA Servo Operated Voltage Stabilizer oil Cooled (Make:- Blue Line/AE/Volina/Bluebird and other existing make) --do—(Notes for Sch`A’ item No 17 above shall also be applicable to this item)
All as per item No. 17 but servicing of voltage stabilizer of 3 KVA to 30 KVA Servo Operated Voltage Stabilizer oil Cooled (Make:- Blue Line/AE/Volina/Bluebird and other existing make) --do—(Notes for Sch`A’ item No 17 above shall also be applicable to this item)
Supply only the following new parts suitable for servo controlled Voltage Stabilizer (MAKE :- Blue Line/AE/Volina/Bluebird and other existing make), as approved by the GE. NOTE : Fixing and testing element of these items is deemed to include under Schedule `A' item No 17 to 21 above )
Variac coil of 150 Ampers
Varriac coil of 100 ampers
Variac coil 60 ampers
Variac coil of 28 Amperes
Carbon brush 150 Amperes.
Carbon brush 100 Amperes.
Carbon brush 60 Amperes.
Carbon brush 30 Amperes.
Variac arm of 150 Amperes
Variac arm of 100 Amperes
Variac arm of 60 Amperes
Variac arm of 28 Amperes
Packing sheet of Variac
Servo Motor 10 Kg - cm 60 RPM, Single Phase
Servo Motor 3 Kg-cm 60 RPM, Single Phase
RC network 10 kg cm
RC network 3 kg cm
PCB Suitable for servo stablizer of capacity up to 400 KVA.
Transformer 18-28 volt
Limit switch for servo motor
limit switch arm
Toggel switch
Dimmer switch preset
Input Output salecter switch
Packing sheet of Variac 150 amp
Packing sheet of Variac 100 amp
Packing sheet of Variac 60 amp
Packing sheet of variac 28 amp
Servo moter gear
Supply & filling transformer oil into stablizer at site for top up all as directed by Engr in Charge.
Material and Labour for dehydration/filtration of old transformer oil of any dielectric strength with using centrifugal filtration machine so as to achieve dielectric strength not less than 40 KV RMS with gap of 3.0 mm in voltage stabilizers including drawing out and refillin complete all as specified and directed by Engineer-in-Charge. Note :- The dielectric strength of Oil should be checked prior to dehydration and result shall be recorded before and after dehydration . The dehydration of Oil is recommended based on kit state diectric value of Oil .
Supply & fixing of maintenance free batteries 12 Volts 65 AH suitable for 30 Kva UPS complete with battery terminal and suitable flexible copper lead including in put and out put lead connections.complete with testing all as specified and directed by Engineer-in -charge. Make :- Exide solar power safe sealed battery
m/s varsha traders
UNIVERSAL AGENCY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .