| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹6.3 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | ||
| 2 | L2₹6.9 L+₹56,607.91 (9.01%)Admitted-Fee/PreQual/Technical/Finance SARCH GANDERBAL J K 191131 | GANDERBAL | JAMMU AND KASHMIR | 191131 | L2 | Admitted-Fee/PreQual/Technical/Finance | ||
| 3 | L3₹7.2 L+₹90,703.44 (14.4%)Admitted-Fee/PreQual/Technical/Finance | L3 | Admitted-Fee/PreQual/Technical/Finance | ||
| 4 | L4₹7.4 L+₹1.2 L (18.3%)Admitted-Fee/PreQual/Technical/Finance | L4 | Admitted-Fee/PreQual/Technical/Finance | ||
| 5 | L5₹7.9 L+₹1.6 L (25.6%)Admitted-Fee/PreQual/Technical/Finance | L5 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹9.3 L
EMD Value
₹18,680
Closing Date
17 Aug 2026, 4:00 pmClosed
Executive Engineer RnB Division Langate
RnB Division Langate
Construction of 06 Roomed Double Storey Building at BHS Mandigam (ELECTRIC PART).
2026_PWDJK_320587_1
25/1854-63/2026-27/RnB/Langate Dated 11/08/2026
Open Tender
Civil Works
Percentage
30 days
Langate
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
MH 0059
₹18,680
22 Aug 2026
12 Aug 2026
18 Aug 2026
12 Aug 2026
17 Aug 2026
12 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point / exhaust fan point with (P+N) 2X1.5 sq.mm FRLS-H (Polycab/Havells/ Finolex/ eqt make as approved by site engineer),PVC insulated copper conductor single core cable in surface / recessed Conduits (Anchor /polycab/ Ravindra/equivalent make as approved by site engineer) , with 6Amp .modular switch (Anchor roma urban/legrand/SSK NV/ABB/equivalent make as approved by site engineer), modular plate, cover in front and suitable GI box (Excld. G.I Box laid earlier )etc of approved quality and make ISO/IEC Certified (quality of wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) job including cost of Circuit Wire in 2.5Sqmm Multi strand Copper wire from Switch board to D.B complete. excluding cost of Conduits ( Separae wiring for inverter points) | 116 | Point | 1,000 | ₹1,16,000 |
| 2 | Wiring for Ceiling fan point with P+N) 2X 1.5 sq.mm FRLS-H ( Polycab/Havells /Finolex/eqt make as approved by site engineer,PVC insulated Copper conductor single core cable in surface / recessed Conduits , 1No. 6Amp .modular switch(Anchor roma urban/legrand/SSK NV/equivalent make as approved by site engineer), modular plate, and suitable GI box(Excld. G.I Box laid earlier ) , Two Module Stepped Type Electronic Fan Regulator of approved quality and make ISO/IEC Certified (wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) including cost of Circuit Wire in 2.5Sqmm Multi strand Copper wire complete | 26 | Point | 1,100 | ₹28,600 |
| 3 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H ( Polycab/Havells/ Finolex/eqt make as approved by site engineer)PVCInsulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Anchor/polycab/Ravindra/equivalent make as approved by site engineer) along with 1 x 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop Earthing of approved quality and ISI marked as required. With . 1NO. 16Amp .Modular switch(Anchor roma urban/legrand/SSK NV/ABB equivalent make as approved by site engineer), Modular 1NO.3-PIN . 16 Amp. Socket , Modular plate, cover and suitable GI box (Excld. G.I Box laid earlier )etc as required . | 18 | Point | 1,500 | ₹27,000 |
| 4 | Wiring for 6Amp Plug with(P+N+E) 3 x 2.5 sq.mm FRLS PVC ,Polycab/Havells/ Finolex/eqt make as approved by site engineer)Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit along with 1 x 2.5 sq.mm FRLS,Polycab/Havells/Finolex/eqt make as approved by site engineer) PVC Insulated copper conductor single core cable for loop Earthing of approved quality and ISI marked as required. with ,2No.6Amp .Modular switch(Anchor roma urban/legrand/SSK NV/equivalent make as approved by site engineer), 2, 2NO. Modular 6 Amp. 5-PIN Socket ,6-8 Module Modular gride plate, cover and suitable GI box etc (Excld. G.I Box laid earlier )as required (wire shall be approved before execution of wok by SITE In-charge Engineer strictly , connections etc. as required.) complete excluding cost of Conduits | 18 | no | 1,300 | ₹23,400 |
| 5 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. (wire shall be approved before execution of wok by SITE In-charge Engineer strictly . | - | - | - | - |
| 6 | 2X 10sq. MM+ 1 X 10 sq. MM (Phase +N+E) Power point Sub main in One runFrom Main Panel to .Distribution boards(Polycab/Havells/Finolex/eqt make ) | 55 | Metre | 480 | ₹26,400 |
| 7 | 2 X 6SQ.MM + 1 X 6. SQ.MM [Phase +N+E) For Lighting Sub main in one run from Main Panel to Distribution board(Polycab/Havells/Finolex/eqt make) | 55 | Metre | 270 | ₹14,850 |
| 8 | 2 X 4SQ.MM + 1 X 4. SQ.MM [Phase +N+E) For Inverter Sub main in one run from Main Panel to Distribution board(Polycab/Havells/Finolex/eqt make) | 55 | Metre | 190 | ₹10,450 |
| 9 | SINGLE POLE (6-32Amp) Legrand /Havells or L&T /Schneider/ABB | 42 | No | 310 | ₹13,020 |
| 10 | Supplying and fixing following rating, Double pole, (P +N) 240 V, C* Curve Residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as reqd. | - | - | - | - |
stage.html
html • 0.03 MB
finance_1066149.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
BOQ_1066149.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .