Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC 107 1F TOLLYGUNGE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC AOC | |
| 2 | L2₹41.6 L+₹1.7 L (4.32%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L2 | Rejected-Finance Other than lowest | |
| 3 | Rejected-Technical 5 1B TARA ROAD KOLKATA 700026 INDIA | KOLKATA | WEST BENGAL | 700026 | - | Rejected-Technical Bidder not appropriate category as per NIT i.e. a(i), c(ii) and b(i) | |
| 4 | Rejected-Technical 205 2ND FLOOR VARDHMAN CHAMBER LL 0 VIKASPURI WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | - | Rejected-Technical Bidder not appropriate category as per NIT i.e. a(i), c(ii) and b(i) |
| Sl No | Description | Qty | Unit | SUDHA ENTERPRISES L2 | S.M.CONSTRUCTIONS L1 |
|---|---|---|---|---|---|
| 1.00 | (B/R PORTION)
Excavation in trench not exceeding 1.5 M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed. | 28 | Cum | 400 ₹11,200 | 350 ₹9,800 Lowest |
| 2.00 | Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in road/hardstanding and getting out complete all as specified and as directed. | 2 | Cum | 450 ₹900 Lowest | 450 ₹900 Lowest |
| 3.00 | Removing excavated material to a distance n exc 50M and deposited where directed at a level exc 1.5M but n exc 5 Km from starting point complete all as specified and as directed. | 28 | Cum | 400 ₹11,200 | 300 ₹8,400 Lowest |
| 4.00 | Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed. | 2 | Cum | 150 ₹300 | 100 ₹200 Lowest |
| 5.00 | M&L hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and cm thick, watered and rammed to a true surface of broken stones complete all as specified and as directed. | 26 | Cum | 3,650 ₹94,900 | 3,500 ₹91,000 Lowest |
| 6.00 | M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection or similar places, laid in alternate bays, surface finished even and fair without using extra cement complete all as specified and directed. | 172 | Sqm | 650 ₹1,11,800 | 550 ₹94,600 Lowest |
| 7.00 | M & L 100 mm thick PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. | 172 | Sqm | 950 ₹1,63,400 | 850 ₹1,46,200 Lowest |
| 8.00 | S&F Machine pressed precast concrete interlocking paver block any shape and size with grey cement with pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade all as specified and directed. | 172 | Sqm | 1,554 ₹2,67,288 | 1,450 ₹2,49,400 Lowest |
| 9.00 | M&L for sand filling under floors or in foundation including watering and consolidation all as directed bg engram in charge | 8.6 | Cum | 3,120 ₹26,832 | 3,000 ₹25,800 Lowest |
| 10.00 | M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. | 5 | Cum | 9,800 ₹49,000 | 9,000 ₹45,000 Lowest |
Tender Value
₹35.5 L
EMD Value
₹71,000
Closing Date
22 Nov 2025, 6:00 pmClosed
Garrison Engineer (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
PROVN OF PNEUMATIC/HYDRAULIC TRACTION LIFT ELEVATOR OF G plus 1 AT OUTSIDE BLDG NO O-6 ALONGWITH ASSOCIATED CIVIL WORKS AND ELECTRIC SUPPLY INSIDE VIJAY DURG UNDER GE (FW) KOLKATA
2025_MES_734569_2
8504/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Garrison Engineer (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (FW) Kolkata
₹71,000
28 Mar 2026
11 Nov 2025
24 Nov 2025
11 Nov 2025
22 Nov 2025
17 Nov 2025
Amount
(B/R PORTION) Excavation in trench not exceeding 1.5 M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in road/hardstanding and getting out complete all as specified and as directed.
Removing excavated material to a distance n exc 50M and deposited where directed at a level exc 1.5M but n exc 5 Km from starting point complete all as specified and as directed.
Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed.
M&L hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and cm thick, watered and rammed to a true surface of broken stones complete all as specified and as directed.
M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection or similar places, laid in alternate bays, surface finished even and fair without using extra cement complete all as specified and directed.
M & L 100 mm thick PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed.
S&F Machine pressed precast concrete interlocking paver block any shape and size with grey cement with pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade all as specified and directed.
M&L for sand filling under floors or in foundation including watering and consolidation all as directed bg engram in charge
M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L brick work with Fly ash bricks' old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed.
S&F in repair 35mm precast cement concrete type B0 1:2:4 using (12.5mm graded stone aggregate louvers and jallies including all mouldings set in CM 1:4 all as directed.
M & L two coats of cement based paint on newly plastered surface of wall including preparation and one coat of chalk white of surfaces complete all as specified and directed.
Material and labour for plain cement concrete (1:4:8) type D-2 (using 40 mm graded granite stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4, surface finished even and smooth without using extra cement mixed with use water proofing compound, surface finished even and smooth complete. Note : Water proofing compound shall be measured and paid separately as supply only.
Supply only integral water proofing compound complete all as specified and directed
Form work Use and waste to sides of concrete foundation, footing, bases of columns, plinth beam, side and soffits of plinth beam and similar works in vertical or to batter of fair finished surfaces complete all as specified and directed.
M&L for RCC (nominal mix ) type B1 1:2:4 (20 mm graded aggregate) in foundations, including rafts, footings, foundation beams ; plinth beams; bases for columns, etc ; basement slabs, under reamed piles and mass concrete complete all as specified and directed.
S&F mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
S&F mild steel Framed work as in doors or sliding gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-410-W(Gde-E-250) quality-A all as specified and directed.
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated)conforming to grade Fe-410- W (Gde- E- 250) quality- A made to required shape and size, welded at joints complete all as specified and directed.
S&F mild steel rolled sections as in main and cross beams, angle, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors etc conforming to grade Fe-410- W (Gde- E- 250) quality- A made to required shape and size, welded at joints complete all as specified and directed.
S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-A complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 all as specified.
S&F Mild steel plates Fe-410-W(Gde?E-250) quality B Mild steel, plain, sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required all as specified and directed.
S&F Mild steel screw bolts (machine made) 16 to 20 mm dia of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, but length of bolt exc 22.5cm and n exc 30cm long all as specified and directed.
M & L applying two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete all as specified and directed
S&F 6 mm thick solid polycarbonate sheet, in roofing fixed with suitable 2 mm thick powder coated aluminium of any colour (Thickness of powder coating not less than 50 micron) profile H or Ɪ section (H & Ɪ base and cape aluminium profile ) roofing profile for quality connection with supporting structure with appropriate top and bottom gasket enables joining and sealing of two polycarbonate sheet at intermediate and end profile for expansion of sheets and prevention of water penetration from joints , including corner coupler (L shape ) and T joining element without visible self tapping screws complete all as specified and as directed. Note -: All aluminium profile / channels incl rubber gasket etc mentioned above shall be include in quoted rate.
M & L for 20 mm thick screed bed or bedding layer of mortar as in backing coat of stone on fair face of brick wall or concrete surface in cement mortar 1:4 complete all as specified and directed.
M & L 18 to 20 mm thick machine cut one side polished natural hard stone (Granite)any type in step, jambs, pillars, window cills, cooking plate from and similar places etc like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
(LIFT PORTION) Supply, erection, testing and commissioning of G+1 Circular Shape Pneumatic lift / elevator of minimum Pay load 240 Kg, Clear Spacing 1430 mm, External Shaft dia 1343 mm, Internal Cabin dia 1160 mm, Cabin height 1950 mm, Clear Door opening 508 mm, Minimum Headroom 2436-2800 mm, soundproofing upto 57 dB with following features as directed by Engr-in-Charge : (i) Single phase power consumption upto 5 HP (ii) 3 Axis adjustable door hinges (iii) Door lock safety arrangement (iv) Emergency alarm (v) Handrail facility (vi) Polycarbonate glass body (vii) Wheel-chair enabled (viii) Rapid Rescue Latch (RRL) (ix) Automatic descent to ground during power outage (x) Child safety switch (xi) Emergency alarm (xii) EEM compliant landing door (xiii) Precision landing levers for floor positioning (xiv) Self-supported glass structure (xv) Polycarbonate glass structure. Note :- (i) Contractor has to submit Minimum Five years warranty on Motor and Air Seal from authorised OEM lift. (ii) All civil works like dismantling of brickwork / iron frame work and make good of structure for erection of lift are to be included in quoted rates.
S&F Voltage stabilizer for automatic operation, Single Phase, naturally air cooled indoor type and designed for input variation between 170 V to 280 V with output voltage 230 V with accuracy level of + 2.5% and capacity of 10.0 KVA complete all as specified and directed.
S&F PVC insulated, armoured and PVC sheathed Copper cable of size 3 Core Cross section 6 Sqmm complete all as specified and directed.
M&L for sheet metal enclosure for DBs SPN 4 way 240 V, with 200 A rated bus bar double door, complete flush mounted all as specified and as directed.
S & F MCB 'C' series single pole 5 to 32 Amps, breaking capacity 10KA.complete all as specified and directed. Make: Cat No. 408587,of Legrand or equivalent make specified in tender.
S & F MCB 'C' curve single pole neutral 32 Amps with breaking capacity 10kA,complete all as specified and directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
SUDHA ENTERPRISES (BID ID -3484471)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
TenderDocu8504.pdf
Tender Documents • 1.69 MB
BOQ_827822.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .