Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹37.9 L+₹1.4 L (3.90%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹40.4 L+₹3.9 L (10.8%)Rejected-Finance PLOT NO RZ B 1 59 KH NO 534 535 BLOCK B 1 NEW ROHANPURA PP NO 1416 NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹42.0 L+₹5.5 L (15.2%)Rejected-Finance RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹42.2 L+₹5.7 L (15.7%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
24 Feb 2022, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
REPAIR/MAINT OF BOUNDARY WALL DRAIN AND OTHER MISC BR CONNECTED ITEMS IN OLD APS NEW APS SIGNAL ENCLAVE ARJAN VIHAR AND PRATAP CHOWK OF AGE BRII UNDER GE CENTRAL DELHI CANTT 10
2022_MES_504477_1
GE/C-62/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
REPAIR/MAINT OF BOUNDARY WALL DRAIN AND OTHER MISC BR CONNECTED ITEMS IN OLD APS NEW APS SIGNAL ENCLAVE ARJAN VIHAR AND PRATAP CHOWK OF AGE BRII UNDER GE CENTRAL DELHI CANTT 10
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹96,000
Yes
2 Mar 2022
29 Jan 2022
26 Feb 2022
29 Jan 2022
24 Feb 2022
12 Feb 2022
29 Jan 2022 - 12 Feb 2022
Amount
Demolition of brick work built in cement mortar in any description and position, complete all as specified.
Brick work with old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified.
All as per serial item No 2 but except bricks, all as specified. (Servicable bricks retrieved from Serial Item No 01 shall be used).
M&L for rendering 15mm thick in cm 1:4 mixed with water proofing compound @ 2% by weight of cement as directed on any face of brick or concrete surfaces and fiished even and smooth without using extra cement applying two coats of cement base paint on newly plastered wall surface complete all as specified.complete all as specified.
M & L Providing, cement concrete in roof kerbs or mud stops, coping to top of wall, rounded or chamfered on edges type B 0 1:2:4 (12.5mm graded stone aggegate) complete all as specified and as directed
S& F MS sections (angle iron/ Channels) of any size and cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 and two coats of synthetic enamel paint over a coat of reoxide primer etc complete all as specified and as directed
S & F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
Restraining & resecuring existing barbed wire of any type incl making good staples etc any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc (each line wire to be measured) complete all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed
S & F Framed bracket of angles or tees with web and flanges cut to shape drilled and countersunk for screw and as is purlins rafter etc including bending and welding agnles, as necessary guest plates conforming to Feb 290 Gde E-165 including two coats of synthetic enamel paint over a coat of reoxide primer up to six storey bldg complete all as specified and as directed
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws up to six storey bldg complete as specified and as directed
M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken stone complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete to ground floor(unreinforced) and paving n.exc 15cm thickness (below or above ground level) and removing rubbish of out side MOD land.
M&L 100mm thick PCC (1:4:8) type D 2 (40mm graded stone aggregate) as in sub base, complete all as specified.
M&L Sand filling (sand cushioning) under floors or in foundation incl watering and consolidation all as spd and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment all as spd and directed
M& L 300 x 300 mm , 22 to 25mm thick chequered cement concrete tiles, set, jointed and pointed in near cement slurry in floors including 15mm thick screed bed in floor in C M 1:6 including cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) as in levelling course 25mm thick including demolition of existing flooring/hardstanding all as specified and disposing to debries etc all as directed. Make Unistones/ Nitco/ Ultra Tiles.
M&L for brick work with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls with old size bricks, built in cement mortar 1:4, complete all as specified.
M & L for 15 mm thick rendering in cement mortar 1:6 on fair face of brick walls/ concrete surfaces & finished even and smooth without using extra cement,applying three coats of white lime wash on newly plastered wall surface complete all as specified.
M& L for cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in plinth protection 75 mm thick laid in bays and surfaces finished even and fair, including filling the joints with bitumen mastic including demolition of existing surface all as specified and disposing to debries etc all as directed by Engr-in-Charge.
M & L for PCC 1:3:6 type C1 as e in surface channels and drain concrete. complete all as specified and directed
Taking down cement plaster in any thickness from brick or stone etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M&L for rendering on fair surfaces of Brick work in CM (1:4), 15 mm thick, fair and even, complete all as spd and diretced.
Demolition of cement concrete (reinforced) of any position in any position not otherwise specifically provided complete all as specified and directed by Engr-in-Charge.
M & L for TMT bars 10 mm dia and over as in reinforcement. complete all as specified and as directed
M &L for precast manhole covers with plain faces using RCC 1:2:4 type B1 and set in CM 1:4 including formwork complete all as specified.
Schedule of Credit
GIAN ENGINEERS
M/S CHANDER MUNI
SHREE RAM BUILD TECH
Som Nath Kakkar
GLOBAL DEVELOPERS COMPANY
VED PRAKASH ARORA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .