Signalling work in connection with closure of LC gates 69,73 by provision of ROB in Kalyan-Igatpuri section of Mumbai Division.
CR-BB-SNT-NORTH-2026-49
CR-BB-SNT-NORTH-2026-49
Open
12 Months
Mumbai, Maharashtra
₹0
₹3.0 L
6 May 2026
6 May 2026
22 May 2026
Supply of Indoor Jumper wire ATC 1x1 mm dia. Conforming to IRS/76/89 (Amd.3) of latest.
Supply of PVC indoor cable 1x24x1 mm dia. Color coding of insulation of Inner conductor shall be in eight colour viz, Blue, Red, Grey, Green, Brown, Black, Yellow & white confirming to IRS 76/89 (Amd. 3) or latest.
Supply of Indoor Jumper wire of various colour as per Railways standard practice of type ATC 1x0.6 mm dia. Conforming to IRS/76/89 (Amd.3) of latest.
Supply of PVC flexible copper cable single core, multistrand 1x10 Sq.mm (80 04 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 1.0 mm nominal conductor resistance 1.91 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest.
Supply of PVC flexible copper cable single core, multistrand 1x25 Sq.mm (196 05 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest.
Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS:S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender.
Supply of Relay rack assembly complete with scaffolding, fixtures and accessories 07 including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 way Bus bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C.Rly. Typical part list as per Annexure-II and Rack arrangement as per sketch no SK-727 and Rack plan as approved by Engineer in charge.
Supply of Tag blocks 200/160/120 way with polycarbonate cover as per IRS S 77- 2006.(Rev.1) RDSO DRG. No.SA 24751, SA 24752 & SA 24753. Requirement of each type shall be specified by Engineer-in-charge.
Supply 8-way Terminal strips, made of PBT, isolating barrier type as per IRS-S-79/92 (Amd. 2) & Drg No SA24811 (Alt.2) & SA24812 (Alt.2) with latest amendment. Per 1463145.0
Modification in existing EI system as per latest TAN, it includes:- Design and modification in existing interface and interlocking circuit of EI system, including modification in VDU,CCIP, MT, Data logger, EI, Relay rack complete wiring conforming to RDSO specification, as per technical requirement & tentative approved signaling plan/diagrams. Required hardware will be provided by railways except the wiring, material (i.e. connectors, interconnecting cable/wires, fuses 10 etc.) The work includes supply of modified ST/LT, interface and logic circuit, CCIP/VDU diagram etc. to suit the approved interlocking plan. It also includes modification in data logger/MT, carrying out FAT, SAT jointly with railways and satisfactory commissioning of the modified EI with full complements as per approved IP and central railway practices. All plans and wiring diagrams shall be prepared on AUTOCAD and supplied in both soft copy and hard copies (6 sets.) Alteration involving modification in up to 10 routes.NOTE : If the alteration involves modification of routes up to 10, fixed cost as per the Rate mentioned in (i) above shall be paid. If the alteration involves modification of routes are more than 10 up to 20 routes, then, fixed cost as per the Rate mentioned in (ii) above shall be paid.
Supply of tag blocks 96/100 way with polycarbonate cover as per IRS S 77-2006. (Rev.1) Requirement of each type shall be specified by Engineer-in-charge.
Supply of Resisters, condensers, Diodes, LEDs and lugs alongwith bracket and mounting arrangement as per standard Annexure-V of Central Railway.
Lacing thread rolls, black, wax coated (100 mtrs)
Supply of Main cable Termination rack complete with scaffolding, fixtures & 14 accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt , nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice of Central Railway. Typical part list as per Annexure-III and rack arrangement shall be as per sketch No.SK-727 with latest alterations.
Supply of modular terminal block of 2.5 sq. mm 2 IN 2 OUT type disconnect type 15 terminal along with as per RDSO SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only.
Supply of DIN Channel for the terminals 1 Mtrs each
Supply of End plates for modular terminal block
Supply of End Clamp for modular terminal block
Supply of Marker Card as per customer spec (10x10)
Fuse terminals block with LED indication up to 2.5 sqmm screw type one in one out (suitable for (400 mA, 630mA, 1 A, 1.6 A, 2 A, 4A, 6.3 A & 10 A ) as per RDSO SPN/189/2004 Ver.03 or latest . (without fuse)
End plate for through terminal block with LED indication.
Fuse links of (400 mA, 630mA, 1 A, 1.6 A, 2 A, 4A, 6.3 A & 10A)
Shorting link insulated Grey in colour
Operating tool (operating tool, screw driver & stripper) as per Annexure-VII.
Supply of Main signal post 140 mm outer dia 4.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments.
Supply of Main signal post 140 mm outer dia 5.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments.
Supply of Cast Iron Main signal surface base 140mm as per spec No IRS: S-10 and 27 Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg no. SA 23156 (Adv), SA 23153 (Adv) & SA 23150 (Adv) Alt.1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C.Rly practice.
Supply of Hand Cuff Locks / Godrej Navtal lock with Three common keys.
Supply of "2 aspect" Signal Unit in FRP body without lenses and transformers as per 29 RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 2 aspect unit to avoid any extra paint cost
Supply of "3 aspect" Signal Unit in FRP body without lenses and transformers as per 30 RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoide any extra paint cost
Supply of "4 aspect" Signal Unit in FRP body without lenses and transformers as per 31 RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoid any extra paint cost
Supply of Program switches, snap action, base mounting type along with cover and mounting bracket 63A-7 pole 3 position Siemens (3 LAO-63/7Y)/L&T/HEVELS type Drg.No.RST.C.106.
Supply of Transformer 230V/110V-130V Single phase 1 KVA as per spec. IRS S-72/88 (Amd.2) with latest amendments.
Supply of Transformer 230V/110V-130V Single phase 2 KVA as per spec. IRS S-72/88 (Amd.2) with latest amendments.
Supply of Battery charger self regulating floor mounting type with 230 V AC single phase input and output 60 V DC, 20 A as per spec.IRS.S.86/2000 (Amd.4) with latest amendments.
Supply of Battery charger self regulating floor mounting type with 230 V AC single phase input and output 60 V DC, 40 A as per spec.IRS.S.86/2000 (Amd.4) with latest amendments.
Supply of Battery charger self regulating floor mounting type with 230 V AC single phase input and output 24 V DC,30 A t o spec.IRS.S.86/2000 (Amndt-1) with latest amendment for Axle counter application (Amd.4)
Supply of Rubber Mat 5mm thick for use in signaling installation.
Supply of signal group 2 aspect without base plate Siemens make (No.A-RT-RG-A066) or functional equivalent and should be suitable for working with LED based signal lighting unit.
Supply of signal group 3 aspect without base plate Siemens make (No.A-RT-RG-A067) or functional equivalent and should be suitable for working with LED based signal lighting unit.
Supply of signal group, 4 aspect Siemens make (No.A-RT-RG-A057) or functional equivalent without base plates.
Supply of Route Group Siemens make (No.RSSK 31/0002) or functional equivalent without base plates.
Supply of Auto signal Block proving Relay Group Siemens make (No.A-RT-RG-A056) or functional equivalent without base plates.
Supply of Desk type Electronic Magneto Telephone as per spec No. IRS TC-79/2000 (Amd.4) with Amendment No.02 or with latest amendments.
Supply of Signal No.Plates as per Drg No RST-11393/ SK-842
Supply of A/AG/C/P/G/IB Board as per Drg. RST-11444/1(A), RDSO Drg No SA- 23460(AG), SA-23461(C) , RST-11445, SA 23456(P), SA 23477(G) & SA 23476-77 (IB) as applicable respectively with Latest Amendment.
Supply of Stop Board / IB Board as per RST-11791 (STOP BOARD)/ RDSO Drg No 7235/B as per extent C.Rly practice.
Supply of different warning Board as per Goods warning Board (SK-784) RDSO Drg No. SA 2380 (Adv), SA 2370/M-, Block section limit Board RDSO Drg No. SA 2373 - Paint and retroreflective arrangement as per Railways drawing.
Supply and Fixing of RE Protective Screens of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per extent practice & as per instruction of Rly engineer at site DRG - No.SK-
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22x1.22 Mtr as per spec. No. IS 2036 of 1995.
Supply of FIBRE GLASS INSULATING FIRE RETARDENT SHEET OF 10 MM THICKNESS AS PER ISO: 10192-1982, Dielectric strenth -25KV/mm with glass content 25 to 34% in standard size of 1.10x1.10 Mtr as per spec. No.IS:10192-1982
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4., SA-23745 Alt.5, SA-23746, SA-23748 Alt.4, & SA-23756 Alt.3.
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No.IRS S 75/2006 Rev.02 with latest amendment. Fuse block shall be suitable for round head type voltage fuses.
Supply of round head type non detoriating type low voltage cartridge fuse as per specn No. IRS/S/78/92 with latest amendments - 2A/4A/6A capacity
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK-815
Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3.
Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13-62
Supply of bond plates suitable for terminating track lead connections of AFTC on rail. It consists of tapered stainless steel bolts, nuts, check nuts, washers, L shaped plate etc. as per drg. 58 No.RST 11630. Each set of bond plates should consist of (i) SS taper pins - 8 nos (ii) SS M6 nuts - 20 nos. (iii) SS M6 plane washers - 32 nos. (iv) Spring washer - 8 nos. (v) Nylon nuts - 8 nos. (vi) S.S.hex bolts M6 x 15 - 2 nos. (vii) Track circuit cable plates - 4 nos. Supply of all above items would constitute one set.
Supply of Pre-wired Crank Handle cum key lock relay box (of metal) alongwith LEDs, with approved type push buttons, 8-way terminal strips, string rod, etc. as per Drawing No.RST.C.114
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make.
Sealed maintenance free VRLA Battery/Cell 2 volt, 300AH IRS: S-93/96 (A) (Amd.1) or latest.
Sealed maintenance free VRLA Battery/Cell 2 volt, 200AH RDSO SPN/93/96 (A) (Amd.1) or latest.
Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest.
Supply of RCC pipes 150mm dia along with collars as per IS No.458/2003 amendment-1 with Rev.4.
Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4.
Supply of RCC pipes half round of size 300 mm dia outer and 250 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4.
Supply of Thermo-Shrink cable joining kit (Reinforced) TSF-2 type generally 67 confirming to RDSO specification RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE's Specification No.:CR/SPN/TC/57 (A)/2015 Dt: 06.01.2015 (Table-A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables alongwith sub-kit (Table-B) for armour continuity.
Supply of 4.5 kg CPO2 type fire extinguisher along with all accesories, extinguisher 68 testing certificate has to be supplied along with - Supply of ISI marked Carbon Dioxide type (BC) fire extinguisher of 4.5 Kg capacity confirming to IS 2878: 2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket etc. as required by site Engineer. Each
Design, fabrication and supply of fuse Auto changeover system for 32 Nos external non detorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. Each
Design, fabrication and supply of fuse Auto changeover system for 24 Nos external non detorating type fuses or 'G' type fuses from 4 A to 10 Amp capacities generally used for point operation circuits. System shall have 6 cards with monitoring arrangement of 4 fuses in one card. As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any.
Supply of Paints as per relevant IS specification preferably Asian / Apcolite/ Dulux make in different colour in one kg/2 kg pack
OFF set bracket 3-1/2' for signals & Routes. Drawing No.SA23840(Adv) Alt-2 as per extent C.Rly practice.
Supply of QNA1-K AC immunized relay, 8F-8B, 24 VDC along with plug, retaining clip 73 and connectors conforming to BRS:931A & RDSO letter no STS/E/Relays/UEA/PI dated 30.05.97 Annexure-II IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1
Supply of QNN1 Twin neutral line relay, 24 V DC 4F- 4B/5F-3B/6F-2B contacts, complete with plug, board, retaining clip and connectors BRS:960
Supply of QSPA1 relay, 24 V DC Slow to pick up, 8F- 4B along with plug, board, retaining clip and connectors conforming to BRS:933 IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1)
Supply of Universal LED Lamp proving relay QECX61 relay, 4F-4B, AC conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt.-1 (FOR ALL ASPECT ECR FOR AC LED SIGNAL)
Supply of QL1 LATCH relay, 11F-4B or 8F-6B along with plug board, retaining clip and connectors conforming to BRB:935A.
Supply of QNNA1- AC immunized relay, 6F-2B, 24VDC along with plug board, retaining clip and connectors conforming to BRS:960, IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1
Supply of QNNA1- AC immunized relay, 4F-4B, 24VDC along with plug board, retaining clip and connectors conforming to BRS:960, IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1)
Supply of Key Lock Relay with different ward combinations (Three extra set of ward 80 plate for point Machine to be supplied with each relay). Siemens make working on 60V DC/24 DC or functional equivalent without base plates. RDSO/SPN/219/2016 version 1.0 with Amendment No.1 or latest. Above/
Excavation of cable trench as per cable route plan, 1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid to trench by loose soil for a layer 9 of 50mm thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8 m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 805
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 01 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783- 1& 2. with latest alterations & as per instructions of Rly engineer at site. a) Single Case
Fixing of cutting in relay bases & wiring of relays with Contractors own material obtained from approved sources in location box as per the instructions of Engineer in charge. Per
Fixing of ARA Terminals and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. Per
Termination of cable cores on ARA terminal/fuse blocks in the apparatus cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.
Excavation and Casting of Apparatus case foundation with contractors Anchor bolts, 05 cement, ballast and other materials. The required scaffolding ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. i) Single Case as per Drg No SK-803
Erection of Apparatus cases. This includes filling of location foundations and plastering .i)Single Case
Installation of Eqpt. (Relays, resistance, chargers batteries etc. as applicable) & wiring of the same in apparatus cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. i) Single Case
Installation of earth electrode assembly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, 08 apparatus case, signals, relay racks, block instruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.
Excavation of cable trench as per cable route plan, 1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid to trench by loose soil for a layer of 50mm 10 thickness afer clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8 m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 805
Cutting of all types of Roads/platforms (except concrete type) for trenching and 11 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 807
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.
Digging of trench 1.0 M deep from rail flange/road level (for LC) and, 0.3 Mtr to 0.6 13 Mtrs wide and back filling after placing of DWC/RCC/GI pipe. (Placing of DWC/RCC/GI pipe coverd separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg No SK 806
Laying of DWC/RCC pipes alongwith collars / RCC Half round pipes in trenches at places of track and road crossings, platform cutting etc.
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.
Jointing of 4 / 6 quad cable with Heat shrinkable straight through jointing kit for 4/6 quad cable.
Making an entrance for new cable in old existing location, Casting concreting and curing of foundation and restoring it to old position by perfect masonary/concreting work. Contractor will ensure that cable entered in Location Box is properly protected.
Painting two coats of synthetic enamel paint over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. 18 Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.(i)Apparatus Cases Full size.
Painting two coats of synthetic enamel paint over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.(ii)Apparatus Cases Half size.
Painting two coats of synthetic enamel paint over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- 20 charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.(iii)Main signal post with signal Units, Surface base and complete fittings as per Centre Railways standard practice.
Painting two coats of synthetic enamel paint over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. 21 Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.(vii)Axle counter devices.
Lettering / Numbering of Signals, Point Machine, Track Lead junction Boxes, Block joints, Apparatus Cases etc.(each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes.(a)Full Case.
Horizontal boring of cable duct of minimum 2.0 Mtr depth along with laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from bottom of the rail/Road crossing with minimum depth reckoned from ground level. The work shall be done as per extant practice & 24 instructions of site engineer. Preparation of site for Horizontal Boring shall be carried out in presence o f Railway Representative. HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
Transportation of signaling material/equipments including loading and unloading in 25 10MT vehicle, anywhere to anywhere, and stacking at destination as per instructions of SSE in- charge as per inventory. For carrying heavy materials like cable drums, DG set, Electrical lifting barrier pedstal, IPS, Batteries, Point machine etc.Unit(Per Ton/Per KM=1 set)
Loading, un-loading & transportation of material from the stores of SSE(SIG) depot or any other nominated place & vice-versa. Unit(Per Ton/Per KM=1 set)
Excavation and Casting of main signal foundation as per Drg No SK 801 with 27 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost.
Erection of CLS post with surface base and signal unit on top or on OFF set Bracket, 28 fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site.
Hot dip Galvanizing as per RDSO Specn. ETI-OHE-13 (4/84) - signal post, OFF set Brackets dia 140 mm and length upto 5600 mm.
Installation on ON/OFF aspect LED's in signal including termination of tail cable on 30 signal, wiring fixing of LED units and testing. The work shall be done as per instruction of Railway engineer at site.
Termination of tail cable on Main signal units and wiring with contractor own material etc. The work shall be done as per instruction of Rly engineer at site.
Fixing of modular termianal/fuse blocks alongwith all accessories with provision of 32 fixing holes on hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing on DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination of modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction of Rly engineer at site.
Termination of cable cores on ARA terminal/Disconnecting link/fuse blocks, in the 33 apparatus Cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.
Design and supply of Detailed signalling circuits including Panel diagram (if required), Route section plan, Selection table, Fuse & negative tag. analysis, Contact analysis, Relay rack arrangement and wire count sheets etc. in A3 size. Completion circuit shall be plotted in AutoCAD. The contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. 34 Railways will return one set of circuit to the contractor duly approved with alterations / corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects along with 6 sets of final approved circuits (out of which one set shall be supplied in transparent bags. Only two sheets of circuits shall be placed in one bag each) shall be submitted to the Railways in case there are no further alteration suggesged by Railways. This also includes modification in yard. i)for IBS/ABS/LC Gate Above/
Supply, Installation,Testing &Commissioning ofIntegrated powersupply (IPS) i) SMPSbased integrated powersupply system withoutMFVRLA battery setconforming to RDSOSpecificationRDSO/SPN/165/2012Version 3.0 with lateramendment for PIstation as per 01 CentralRly. Drg.No.SK-793/Awith later correction ifany, Scope of supply,Checking ofinstallation, testing andcommissioning of IPSshall be as per RDSOletterNo.STS/E/IPS/GenlDated 03/04/2008 orlatest if any ii) SealedMaintenance free VRLAbattery set of 60 Cells (stackable), incombination of 55+5 Cells for SMPS basedintegrated powersupply system cell of 2Volt/300 AH Capacity,fully chargedconforming to RDSOSpecification No.IRS:S:93/96(A) withlater amendment.,complete withconnecting links andsuitably numbered instackable racks alongwith user manuals(Inspection Agency-RDSO)
Item Breakup - C-NON SOR ITEM
Supply of cable route marker as per RST/C/203 of Numbers 13.00 FRP(Inspection Agency-Consignee)
WELD LESS MODULAR TYPE SS MEDUIM SIZE Numbers LOCATION BOX(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Supply of DWC/HDPE pipe with one snap fit Metre coupler 'O' ring confirming to IS 14930 (Part 2: 2001) Non metallic, normal duty, pliable with protection against chemical attack and fire resistant, anti rodent, in 6 meter length of size 50 mm inner dia.(Inspection Agency-Consignee)
Supply of counting head ZP D 43 complete with Numbers sensor for Siemens make MSDAC(Inspection Agency-RDSO)
Wheel detection sensor with 10 meter cable for Numbers Siemens MSDAC as per RDSO /SPN/176/2013 ver 3 Siemens make(Inspection Agency-RDSO)
"Amplifier Trigger and Bandpass Filter Board Numbers (VESBA Card ) Individual Module of Central Evaluator for Siemens MSDAC as per RDSO/SPN/176/2013 Ver. 3.0 & Manufactures Specification SIEMENS Make. Make : SIEMENS (Inspection Agency-RDSO)"
SK 30H double rail contact with 8 meter cable for Numbers Eldyne make Multi/Single section Digital axle Counter as per RDSO specification no. RDSO/SPN/176/2013 ver.3 or latest and Manufacturer specification. Make Eldyne electro systems Pvt. Ltd. (One no. packet contains the 02 no. TX and 02 nos RX coils for rail connection sufficient for 1 DP including all accessories. (Inspection Agency-RDSO)
Supply of AC & DC low current clamp meter with Numbers range 1 mA to 100 A; make GTC CM 100 or similar model from make Fluke, Rishabh, KOIKO(Inspection Agency-Consignee)
Supply of Microcontroller based programmable Numbers static switching module of Naturally air-cooled only with an at a glance LCD display suitable for break-less switching between two DC supplies of upto 40 A for 20-110 VDC . (Inspection Agency- Consignee)
Installation programmable static switching module of Naturally air-cooled only with an at a glance LCD display suitable for break-less switching between two DC supplies of upto 40 A for 20-110 VDC . (Cable by Railways)(Inspection Agency- Consignee)
ROCOIL BIGTRON RAIL CURRENT TRANSDUCER Numbers FOR MEASURING SIGNALLING CURRENT IN RAILWAY LINE WITH 3 SENSITIVITY RANGES FILTERED MODE 10A/VOLT AND 1A/VOLT AND UNFILTERED MODE (NO FILTERING @ 50Hz) : 1A/VOLT (Inspection Agency- Consignee) (Inspection Agency-Consignee)
"""Sanwa Model No. HG561H 7 range Low Voltage Numbers Insulation Tester with preset voltages of 15/25/50/100/125/250/500V. Auto AC/DC V selection and Continuity measurement function,. LED Level Meter for MOhms. IP30.""(Inspection Agency-Consignee)"
G Type Fuse Holder 25A with 10 Amp Fuse Link ( Numbers 30.00 Bottle type) Make- Viral,Bharat or Linder only(Inspection Agency-Consignee)
Supply of straigt shank twist drill jobber size 13 Numbers 30.00 mm of make Addison, JK as per IS 5099/1983 for material & hardness (Inspection Agency- Consignee)
Battrey oprated drill m/c cutter 22.5 mm Rail TCT Numbers Cutter 22.5x 55 mm (Part No: 240289)(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Battrey oprated drill m/c drill (13mm) - 20 nos Numbers Twist Drill Size 13x19 mm L (Part No: 5223118) (Inspection Agency-Consignee)(Inspection Agency-Consignee)
Soldering Iron 50W/230V. Make: Soldron similar.(Inspection Agency-Consignee)
Maintenance Tool Kit for MSDAC ETU001 Eldyne Numbers make against the test certificate & guarantee certificate of OEM.Consisting of Items as listed below and as prescribed by OEM but not limited to:- 1. True RMS Digital Multimeter with probe set-01 no. 2. Extended wired socket to Interface with diagnostic plug- 01 no 3. Selector Switch on Panel Base- 01 no. 4. Adjustable Torque Wrench with 13 mm and 19 mm inserts-01 set 5. 19 mm Double ended spanner- 01 no. 6. Dummy Wheel- 01 no. 7. Crimping Tool- 01no.(Inspection Agency- Consignee)
Talk back Loud Speaker Press to talk working on Numbers 110V AC/12VDC bridge loss 5DM maximum power loss 25 DB speaker out put 0.5 watt maximum power consumption 3watt suitable for use on underground cable . The materials to be approved by Rly. Engineer before supply.(water proof One post type & one Table type in one set) suitable for 810 Km range, with regulated power supply (with IC 7812 ONLY) with S S 304 Safety cover 1.5mm thickness and 4mm thick S.S 304 fixing arrangement on signal post. (Inspection Agency- Consignee)
Industrial Compartments. Made out of 18/19 gauge CR sheet with individual locking arrangement (1) size of locker 36 in Width) x 19 in (depth) x 6 foot (Height) (2) with 2 legs of each size 5 inch (H) x 3 inch (W) x 19 inch (D) (3) Size of each compartment 10.74 in (H) x 16.25 in (W) x 19 in (D) 2 in rows and 6 in columns with Siemens gray colour make.(Inspection Agency-Consignee)
Arrangement of Battery operated Rail Core Drill Numbers alongwith additional 18 mm TCT Rail Core Drill , Maximum core cutting capacity : 36 mm, Rated speed: 250/450 RPM, Battery type: Li-on, Battery voltage: 50 Volt, Battery pack capacity: 4 AH, Number of Battery supplied: 2 Nos, Number of Charger supplied: 1 No, Special design pressurized Internal spindle cooling to give maximum life of core cutter and to avoid heating of the rail. Time taken to drill one hole of 32 mm in 60 KG 90 UTS rail section less than one minute. Time taken to fix the machine on the rail, less than 2 minutes and to de-clamp less than 1 minute. 34 Number 32 mm diameter hole with full charge batteries (17 hole per battery) in 60 Kg 90 UTS rail section. 3 Sets of standard center rail drilling adapters for gauge 90, 52, 49 provided along with machine. Weight of machine with battery: 18.5 KG, Make: Eibenstock. Bosch, KPTL(Inspection Agency-Consignee)
Panel push button for Siemen%u2019s signal Numbers 60.00 panel with contact making assembly of various colour Red, Grey, Blue, Yellow & Blue white dot complete. Consisting of colour Red-200, Blue-200 , Blue with white dot-200, Grey-200, Yellow-100, GREEN-100.(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
"24V DC/110V DC/110V AC Hooter with 2 Numbers speakers,15 watt amplifier and built in flasher unit .Make Pradeep , Ahuja ,Global devices 2 MAKE ; GLOBAL DEVICES 212, 24V DC LC GATE HOOTER WITH 2 SPEAKER,22W AMPLIFIER AND BUILT IN FLASHER UNIT(Inspection Agency-Consignee)
MODEM SUITABLE FOR SIEMENS MAKE MSDAC Numbers SYSTEM TO WORK ON E1 & QUAD WITH AUTOMATIC BUMPLESS CHANGEOVER) Make- Efftronics,Siemens(Inspection Agency-Consignee)
"ACRYLIC SHEET TRANSPARENT SIZE 8 FEET X 4 Numbers FEET THICKNESS 5 mm ACRYLIC SHOULD HAVE SCRATCH RESISTANT PROPERTIES(Inspection Agency-Consignee)"
Supply of Rapid Joint LS3, suitable for cable Numbers Jonting of Signalling cable of various size, having dielectric strength > 20KV/mm, Non Toxic, low viscosity, Flamability point > 200 C, Re-entrable, Long storage life Make RAYTECH or Similar. (Inspection Agency-Consignee)
Fencing section for Location boxes 4.5 ftx1.0ft Square (Running feet) As per Rly Drg. No. RST 12103 Rev Foot A(Inspection Agency-Consignee)
I-Beam (100mmx50mmx6mm) of 6 ft height for Numbers 70.00 the support of location box fencing Rly. Drg. No. RST 12103 Rev. A(Inspection Agency-Consignee)
Lumpsum installation charges for fencing of Numbers 30.00 location boxes including concreting work for one site (Inspection Agency-Consignee)
Providing Road Breaker/concrete breaker/boulder Numbers 15.00 or rock breaker with compressor & Jack Hammer for Railway work such as cutting & dismantling of road concrete/Brick pucca structure (RCC/Steel section) including contractors fuel, driver and all other charges.(Inspection Agency-Consignee) (UNIT NUMBER SHOULD BE READ AS PER HOUR)
Repairing of location foundation with masonary Numbers work. This also includes cleaning the locations, sand filling in the location and plastering inside the location(Inspection Agency-Consignee)
"Complete barrier pedestal without boom Numbers complete with gear drive unit clutch motor timing belt & 8 contact circuit controller, terminal & wiring pedestal frame housing & counter balance channels, 110VAC make Heidz India make lifting barrier, confirming to RDSO specn no RDSO/SPN/208/2012 with latest amendment. (Inspection Agency-Consignee)"
Supply of Complete Boom Locking Post unit with Numbers larger SLD solenoid locking lever with bearing and bearing block two numbers magnet switches in aluminium die cast body and 1 number IP 67 imit switch with 2NC contact compatible to Heidz make ELB confirming to RDSO specification(Inspection Agency-Consignee)
Limit Switch new top roller type with 2 NO+2NC Numbers 39.00 contacts as per RDSO specification no IRS/S- 41/70 or Latest amendment suitable for Heidz make electrical lifting barrier of Indian railways. Make: Jay Balaji, L&T, Seimens(Inspection Agency- Consignee)
Air Break Contactor 110V AC 32 Amps, 2NO + Numbers 20.00 2NC. Make: L&T, Siemens or GE.(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Supply of octagonal booms 32 feet long suitable Numbers to HEIDZ make EOLB without hand generator as per RDSO SPEN no: RDSO/SPN/208/2012 with latest amendments. One boom have four pieces of 8 ft long.(Inspection Agency-Consignee)
"Analog Megger 500 V/100V, 0-1000 Mega Ohm, Numbers Metal Body, Hand Operated, Supplied with Leads Test and Calibration Certificate with Minimum 1 Year Warranty Make : PICO/MEGGER/MICO or Similar.(Inspection Agency-Consignee)"
Supply of Quad cable conductor earth resistance Numbers sencing unit, microprocessor based for 24 no. of conductors with meretring facility for one conductor at a time as per attched technical specification.(Inspection Agency-Consignee) (Inspection Agency-Consignee)
Supply of Cable fault locator as per specification. Numbers Make : Tempo, Stanlay or Greenlee. Module SIDEKICK PLUS 1155-5001 of Stanley or similar of Tempo or Greenlee(Inspection Agency-Consignee)
Execution of S & T work related to Job enginnering/Signalling block ofCTR/TTR/TSR or others, inone block, five unskilledmanpower have to beprovided during block for S&Tconnection removing &refixing as per Railway siteengineer instruction.(Inspection Agency-Consignee)
Supply of GPS tagging featured cable route Numbers locator/tracer set suitable for detecting underground armoured optic fiber cable (OFC) and signaling cables with LCD Graphic Display active/passive modes and depth range. 3M-10m. Model STLOC10 GPS make Stanlay or equivalent. (Inspection Agency-Consignee)
Casting of cement concrete to protect S&T cum equipments and laid cables, above pipes, Signal store etc by concrete mixture of cement, sand, stone in the ratio of 1:2:4 using 25 mm graded stone aggregate as per instruction of site in charge of railways. Concrete is to be casted with the help of suitable size shuttering form as per site requirement. Concrete is to be cured for sufficient time as per standard practices on railways(Inspection Agency-Consignee) Total 6645579.61
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022.pdf
ATTACHMENT
CORRECTIONSLIP1to11GCC2022_compressed.pdf GCC CORRECTION SLIP 1 TO 11
ATTACHMENT
37.ATGAON0415-H30.01.2023DS.pdf
ATTACHMENT
FINALNEWTENDERDOC202649.pdf
ATTACHMENT
CORRECTIONSLIP1to11GCC2022_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid