Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹15.6 L
EMD Value
₹31,280
Closing Date
27 Sept 2024, 5:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Avionics Division, Hyderabad
Avionics Division, Hyderabad
Electrical works for Rewiring of CRI quarters in Township
9601
HAL/HD/MT/RT/24-25/8
Works
Accessories Complex- Avionics Divn-Hyderabad-Plant Maintenance
₹0
₹31,280
27 Sept 2024
6 Sept 2024
6 Sept 2024
27 Sept 2024
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, Contractor registration No etc.,
Address for correspondence:
GST NO.:
PAN No.:
Contact details
Please Enter Contact person Name
Pls Enter Mobile No
Average annual financial turn over during the last 3 years, ending financial year 2023 [ should not be less than 30% of Amount put to tender]. Turnover for 3 years are compulsory.
TURN OVER IN Rupees
Pls Enter Turn over in Rs. for all the 3 years
ESI & PF Nos with proof (If any)
Related Document to be Uploaded to e-Procurement Portal
Bank(s) details: [Copy of the cheque leaf to be uploaded]
Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the date of Tender submission.
Pls Enter Details to 'Name of the Bank' , 'Date of Issue','Value in Rs
Experience of having successfully completed similar works during last 7 years ending last day of month previous to the one in which applications are invited. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of Amount put to the tender.
80% (One Work)
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Please enter Details for Work No 1
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No II
work done
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No III
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
Pls Enter Details for Person holding Power of Attorney
DECLARATION I
Pls Accept The Delarication
DECLARATION II
Pls Accept the Delaration II
Description
Removal of items:Removal of existing aluminium point wiring of light ,fan,socket or power complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators,sockets, light fittings for 1 quarters etc.removing materials to township store as directed by EIC
Power DB:Supply, Installation, following factory made SPN MCB Distribution board. The Enclosure shall be made of 1.6 mm thick CRCA Sheet Steel powder coated with approved shade and partition to segregate phase with covers & mounting concealed on wall with suitable angle iron frame & grouting fixtures, anchor bolts & nuts with inter connections complete.12 way SP & N MCB DB with encloser double door type & 200 amp rating Busbar. Incomer 63 Amps DP RCBO sensitivity 100milli amps- 1 Nos. Outgoing 16-32 Amp SP MCB - 10 Nos Make:Legrand,& Seimens.
Main Power Wiring :Supply and laying of 2x10.0 Sq mm + 1x6.0 sqmm earth wire, FR PVC Insulated flexible copper conductor 1100 volts grade with suitable PVC conduit pipe Concealed on wall with suitable saddles, clamps etc and terminating with suitable crimping copper lugs as per site requirement. Green colour wire shall used for earthing and making connections complete from main DB to individual quarters through meter boards (Note: Red / Yellow / Blue colour wire shall be used for phase, Black colour for Neutral & Green colour for Earth) ( from mains to DB) Make: Finolex/Havells/Gloster/Polycab/KEI
Air Conditioner Power Wiring:Supply and laying of 2x4.0 Sq mm + 1x2.5 sqmm earth wire, FR PVC Insulated flexible copper conductor 1100 volts grade with suitable dia PVC conduit pipe Concealed on wall with suitable angular bends, clamps etc and terminating with suitable crimping copper lugs as per site requirement. Green colour wire shall used for earthing and making connections complete from DB to Air conditioner switch boards and other socket provision points (Note: Red / Yellow / Blue colour wire shall be used for phase, Black colour for Neutral & Green colour for Earth) Make: Finolex/Havells/Gloster/Polycab/KEI
Power Wiring for switch boards:Supply and laying of 2x2.5 Sq mm + 1x1.5 sqmm earth wire, FR PVC Insulated flexible copper conductor 1100 volts grade withsuitable dia PVC conduit pipe Concealed on wall with suitable pvc bends, clamps etc and terminating with suitable crimping copper lugs as per site requirement. Green colour wire shall used for earthing and making connections complete from DB to lighting switch boards and other socket provision points (Note: Red / Yellow / Blue colour wire shall be used for phase, Black colour for Neutral & Green colour for Earth). power wiring Make: Finolex/Havells/Gloster
Point Wiring for lights: Wiring for following light with 2 runs of 1.5 sq. mm and 1 run of 1.0 sq. mm FR PVC insulated flexible copper wires, 1100 volt grade of approved make with suitable size PVC conduit pipe with all accessories like bends,ceiling roses, metal boxes Concealed on wall with suitable fixing clamps, bends, nuts & bolts as directed by EIC. scope includs: providing angle holder or ceiling rose and inter connection complete and The controlling switches shall be connected in switch boards(contractor scope) with interconnection complete.Make: Finolex/Havells/Gloster. 1 Light controled with 1 Nos 6A/10A Modular switch
Point Wiring for Fans: 2 runs of 1.5 sq. mm and 1 run of 1.0 sq. mm FR PVC insulated flexible copper wiring with stepped electronic regulator, 1100 volt grade of approved make with suitable size PVC conduit pipe with all accessories like bends, special junction boxes/ceiling roses,metal boxes, Concealed on wall with suitable fixing clamps, saddles, nuts & bolts as directed by EIC. scope includes providing angle holder or ceiling rose and inter connection complete. The controlling switches shall be connected from below mentioned switch boards with interconnection complete.Make: Finolex/Havells/Gloster. 1 Nos Fan point controled with 1Nos Modular switch and electronic step regulator
Mod switch boards-Supply and fixing of 6modular switch board with with 2 nos of 6A,16 Amps SP modular switches, 2Nos 6,16 A sockets . The box shall be concealed on wall with suitable fixing accessories.Make: Fixing accessories-Legrand/Philips/Anchor Note: Scope includes replacement of existing switch board with necessary cement patch work as directed by EIC
Mod switch boards-Supply and fixing of 3 modular switch board controlled with 1nos of 16 Amps SP modular switches, The box shall be concealed on wall with suitable fixing accessories.Make: Fixing accessories-Legrand/Philips/Anchor Note: Scope includes replacement of existing switch board with necessary cement patch work as directed by EIC
Provisioning of Energy Meter Board: Supply & Provisioning of meter board of size 6 inch depth , height and width dimentions as per site dimentions for accomidating 6 nos meters , made of 14 SWG CRCA Sheet Steel metal. The board shall be powder coated & finished with 2 coats of Siemens Grey shade of approved make . The board shall be mounted on suitable 5 mm thick MS angle frame and grouted on wall with cement concrete. Knock out holes shall be provided on the Board as per site requirement. The board cover shall be double leaf door made of 8 mm thick hylam sheet for mounting the Single phase energy meters and fuse units on the top. The door shutters made of hylem sheet shall be supported with hinges & necessary door locking arrangement complete ,board shall incorporate following items and inter connecting with FR PVC Insulated flexible copper wires of 6 Sq mm and termination with suitable lugs with all interconnections complete for meters with follwing requirements- 1) 4 nos 1 feet 25*3 mm cu strips for busbar mounted on porcelean brackets 2) 7 Nos 63 A 2 pole MCBs mounted over hylem sheet , 6 nos for meters and 1 nos for stair case connections. 3)Existing 6 Nos energy meters as per site to be mounted over hylam doors through 6 nos 2 pole 63A MCBs
Provisioning of Energy Meter Board: Supply & Provisioning of meter board of size 6 inch depth , height and width dimentions as per site dimentions for accomidating 2 nos meters , made of 14 SWG CRCA Sheet Steel metal. The board shall be powder coated & finished with 2 coats of Siemens Grey shade of approved make . The board shall be mounted on suitable 5 mm thick MS angle frame and grouted on wall with cement concrete. Knock out holes shall be provided on the Board as per site requirement. The board cover shall be double leaf door made of 8 mm thick hylam sheet for mounting the Single phase energy meters and fuse units on the top. The door shutters made of hylem sheet shall be supported with hinges & necessary door locking arrangement complete ,board shall incorporate following items and inter connecting with FR PVC Insulated flexible copper wires of 6 Sq mm and termination with suitable lugs with all interconnections complete for meters with follwing requirements- 1) 4 nos 1 feet 25*3 mm cu strips for busbar mounted on porcelean brackets 2) 3 Nos 63 A 2 pole MCBs mounted over hylem sheet , 2 nos for meters and 1 nos for stair case connections. 3)Existing 2 nos energy meters as per site to be mounted over hylam doors through 2 nos 2 pole 63A MCBs
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
TBRT8.pdf
TENDER_DOCUMENT • 1.92 MB
ChecklistofDocuments.pdf
TENDER_DOCUMENT • 0.02 MB
NITCT8.pdf
TENDER_DOCUMENT • 0.30 MB
PROCESSDOCUMENTFORSBICOLLECT.pdf
TENDER_DOCUMENT • 1.18 MB
coveringletterEMD.pdf
TENDER_DOCUMENT • 0.01 MB
AnnexureI.pdf
TENDER_DOCUMENT • 0.01 MB
AnnexureIIB.pdf
TENDER_DOCUMENT • 0.01 MB
AnnexureIIC.pdf
TENDER_DOCUMENT • 0.01 MB
AnnexureL.pdf
TENDER_DOCUMENT • 0.01 MB
EFTmandateform.pdf
TENDER_DOCUMENT • 0.01 MB
ProformaA.pdf
TENDER_DOCUMENT • 0.01 MB
ProformaB.pdf
TENDER_DOCUMENT • 0.01 MB
PQRT8.xlsm
TENDER_DOCUMENT • 0.03 MB
PricebidRT8.xlsm
TENDER_DOCUMENT • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .