Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.7 LAccepted-AOC | L1 | Accepted-AOC L1 Tenderer | |
| 2 | L2₹64.8 L+₹5.1 L (8.53%)Rejected-Finance 3 4 JEEVAN DEEP BUILDING 10 PARLIAMENT STREET NEW DELHI 1 PH 011 43573493 9899713006 | L2 | Rejected-Finance Other than L1 | |
| 3 | Rejected-Technical 145 A HSIDC HSIDC SECTOR 31 FARIDABAD FARIDABAD HARYANA 121003 | FARIDABAD | HARYANA | 121003 | - | Rejected-Technical Technically Not Qualified | |
| 4 | Rejected-Technical | - | Rejected-Technical Technically Not Qualified |
Tender Value
₹67.7 L
Closing Date
17 Nov 2021, 4:00 pmClosed
Dy. Gen. Manager, Contracts and MM
ES/Contracts, BEL, Bangalore
Supply, Installation, Testing and Commissioning of Screw Chiller and accessories for PVD, BE BG.
2021_BEL_87760_1
10/000019/0021
Open Tender
Miscellaneous
Item Rate
240 days
ES/Contracts, BEL, Bangalore
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
Exempted
video conferencing
30 Mar 2022
19 Oct 2021
18 Nov 2021
19 Oct 2021
17 Nov 2021
19 Oct 2021
19 Oct 2021 - 26 Oct 2021
27 Oct 2021
Amount
PART A - CHILLER AND PUMPS
Supply, Installation, testing and commissioning of Water cooled Screw chiller of capacity not less than 130TR operating with R134a refrigerant complete with microprocessor based control panel with display, with direct or gear driven, Hermetically or semi hermetically sealed mono/ twin screw, with single or multiple compressor with motor, with single or multi circuit for refrigerant, shell and tube condenser, shell and tube evaporator, refrigerant piping, in built STAR DELTA starter, with stabiliser or CVT if required for microprocessor panel including automatic capacity control system all controls, interconnections, accessories, necessary insulation, base frame, vibration isolators, refrigerant throttling device to suit the screw chiller at FOR BEL Bangalore all as specified and/ or directed etc., complete. Note 1): The capacity of Water cooled Screw chiller shall not be less than 130 TR at the following Rating Conditions. Chilled water outlet temperature: 44.0 0F Chilled water inlet temperature: 54.0 0F Condenser water inlet temperature: 85.0 0F Condenser water outlet temperature: 94.3 0F Evaporator fouling factor :0.0001 h.ft2.0F/Btu Condenser fouling factor : 0.00025 h.ft2.0F/Btu Note: The RCC foundation provided for installation will be measured and paid under the relevant item of SOQR.
Supply, installation, testing and commissioning of end suction back pull out type centrifugal Chilled water Pump set having flow rate not less than 10.5 LPS and 53 M head, Motor class-IE2, IP 55 T.E.F.C (415V, 3ø power supply) with F class insulation, SS / EN8 shaft, complete with couplings, common base frame, bronze impeller, cast iron casing, mechanical seal, vibration isolators, coupling guard, foundation nut bolts and corrosion resistant finish etc. with all accessories. Pump efficiency shall not be less than 55%. Note:1) The PCC foundation/ bed provided for installation of pumps will be measured and paid under the relevant item of SOQR."
Supply, installation, testing and commissioning of end suction back pull out type centrifugal Chilled water Pump set having flow rate not less than 21 LPS and 32 M head, Motor class-IE2, IP 55 T.E.F.C (415V, 3ø power supply) with F class insulation, SS / EN8 shaft, complete with couplings, common base frame, bronze impeller, cast iron casing, mechanical seal, vibration isolators, coupling guard, foundation nut bolts and corrosion resistant finish etc. with all accessories. Pump efficiency shall not be less than 70%. Note:1) The PCC foundation/ bed provided for installation of pumps will be measured and paid under the relevant item of SOQR."
Supply, installation, testing and commissioning of end suction back pull out type centrifugal Chilled water Pump set having flow rate not less than 13.2 LPS and 25 M head, Motor class-IE2, IP 55 T.E.F.C (415V, 3ø power supply) with F class insulation, SS / EN8 shaft, complete with couplings, common base frame, bronze impeller, cast iron casing, mechanical seal, vibration isolators, coupling guard, foundation nut bolts and corrosion resistant finish etc. with all accessories. Pump efficiency shall not be less than 70%. Note:1) The PCC foundation/ bed provided for installation of pumps will be measured and paid under the relevant item of SOQR."
Supply, installation, testing and commissioning of end suction back pull out type centrifugal Chilled water Pump set having flow rate not less than 6.1 LPS and 54 M head, Motor class-IE2, IP 55 T.E.F.C (415V, 3ø power supply) with F class insulation, SS / EN8 shaft, complete with couplings, common base frame, bronze impeller, cast iron casing, mechanical seal, vibration isolators, coupling guard, foundation nut bolts and corrosion resistant finish etc. with all accessories. Pump efficiency shall not be less than 55%. Note:1) The PCC foundation/ bed provided for installation of pumps will be measured and paid under the relevant item of SOQR."
Supply, installation, testing and commissioning of end suction back pull out type centrifugal Condenser water Pump set having flow rate 24.6 LPS and 30 M head, Motor class- IE2, IP 55 T.E.F.C (415V, 3ø power supply) with F class insulation, SS410 shaft, complete with couplings, common base frame, bronze impeller, cast iron casing, mechanical seal, vibration isolators, coupling guard, foundation nut bolts and corrosion resistant finish etc. with all accessories. Pump efficiency shall not be less than 70%. Note: 1) The PCC foundation/ bed provided for installation of pumps will be measured and paid under the relevant item of SOQR."
Supply, erection, testing and commissioning of MS pipes of Ø150 mm, Heavy Grade (Class-C) as per IS 1239 for chilled water pipeline with 32 mm thick closed cell nitrile rubber insulation including providing 0.63 mm aluminium sheet cladding over insulation with necessary fittings, PUF / Neoprene saddle, all welded/ flanged joints all as specified and/ or directed etc. complete. NOTE: 1) The rate to be quoted for the pipes shall be excluding the cost of steel, masonry/ cement concrete supports provided for the pipes and the same will be measured and paid separately under the relevant item of SOQR.
Supply, erection, testing and commissioning of MS pipes of Ø125 mm, Heavy Grade (Class-C) as per IS 1239 for chilled water pipeline with 32 mm thick closed cell nitrile rubber insulation including providing 0.63 mm aluminium sheet cladding over insulation with necessary fittings, PUF / Neoprene saddle, all welded/ flanged joints all as specified and/ or directed etc. complete. NOTE: 1) The rate to be quoted for the pipes shall be excluding the cost of steel, masonry/ cement concrete supports provided for the pipes and the same will be measured and paid separately under the relevant item of SOQR.
Supply, erection, testing and commissioning of MS pipes of Ø100 mm, Heavy Grade (Class-C) as per IS 1239 for chilled water pipeline with 32 mm thick closed cell nitrile rubber insulation including providing 0.63 mm aluminium sheet cladding over insulation with necessary fittings, PUF / Neoprene saddle, all welded/ flanged joints all as specified and/ or directed etc. complete. NOTE: 1) The rate to be quoted for the pipes shall be excluding the cost of steel, masonry/ cement concrete supports provided for the pipes and the same will be measured and paid separately under the relevant item of SOQR.
Supply, erection, testing and commissioning of MS pipes of Ø80 mm, Heavy Grade (Class-C) as per IS 1239 for chilled water pipeline with 32 mm thick closed cell nitrile rubber insulation including providing 0.63 mm aluminium sheet cladding over insulation with necessary fittings, PUF / Neoprene saddle, all welded/ flanged joints all as specified and/ or directed etc. complete. NOTE: 1) The rate to be quoted for the pipes shall be excluding the cost of steel, masonry/ cement concrete supports provided for the pipes and the same will be measured and paid separately under the relevant item of SOQR.
Supply, erection, testing and commissioning of MS pipes of Ø150 mm, Heavy Grade (Class-C) as per IS 1239 for condenser water pipeline with necessary fittings, PUF / Neoprene saddle, painting, all welded/ flanged joints all as specified and/ or directed etc. complete. NOTE: 1) The rate to be quoted for the pipes shall be excluding the cost of steel, masonry/ cement concrete supports provided for the pipes and the same will be measured and paid separately under the relevant item of SOQR.
Supply, erection, testing and commissioning of MS pipes of Ø125 mm, Heavy Grade (Class-C) as per IS 1239 for condenser water pipeline with necessary fittings, PUF / Neoprene saddle, painting, all welded/ flanged joints all as specified and/ or directed etc. complete. NOTE: 1) The rate to be quoted for the pipes shall be excluding the cost of steel, masonry/ cement concrete supports provided for the pipes and the same will be measured and paid separately under the relevant item of SOQR.
Supply, erection, testing and commissioning of MS pipes of Ø100 mm, Heavy Grade (Class-C) as per IS 1239 for condenser water pipeline with necessary fittings, PUF / Neoprene saddle, painting, all welded/ flanged joints all as specified and/ or directed etc. complete. NOTE: 1) The rate to be quoted for the pipes shall be excluding the cost of steel, masonry/ cement concrete supports provided for the pipes and the same will be measured and paid separately under the relevant item of SOQR.
Supply, erection, testing and commissioning of MS pipes of Ø80 mm, Heavy Grade (Class-C) as per IS 1239 for condenser water pipeline with necessary fittings, PUF / Neoprene saddle, painting, all welded/ flanged joints all as specified and/ or directed etc. complete. NOTE: 1) The rate to be quoted for the pipes shall be excluding the cost of steel, masonry/ cement concrete supports provided for the pipes and the same will be measured and paid separately under the relevant item of SOQR.
Supply, erection, testing and commissioning of Butterfly valve of Ø150 mm with CI body, SS Disc, PN 16 rating, nitrile rubber seal & O-ring, wafer type with flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete. Note: This valves are required in inlet/outlet for Chiller Condenser water line and condenser water pumps.
Supply, erection, testing and commissioning of Butterfly valve of Ø125 mm with CI body, SS Disc, PN 16 rating, nitrile rubber seal & O-ring, wafer type with insulation, cladding over insulation, flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete. Note: This valves are required in suction/discharge for circulation pumps
Supply, erection, testing and commissioning of Butterfly valve of Ø100 mm with CI body, SS Disc, PN 16 rating, nitrile rubber seal & O-ring, wafer type with insulation, cladding over insulation, flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete. Note: This valves are required in suction/discharge for circulation pumps
Supply, erection, testing and commissioning of Butterfly valve of Ø80 mm with CI body, SS Disc, PN 16 rating, nitrile rubber seal & O-ring, wafer type with insulation, cladding over insulation, flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete.
Supply, erection, testing and commissioning of Ø125 mm BALANCING VALVE WITH BUILT IN MEASURING FACILITY with CI body flanged construction with EPDM coated disc with long pitch & PN 16 pressure rating with insulation, cladding over insulation, drain port, flanges, fittings, gasket, nuts, bolts, washer, all as specified and/or directed etc., complete. Note: This valve is required in chilled water return line of Chiller.
Supply, erection, testing and commissioning of Ø150 mm BALANCING VALVE WITH BUILT IN MEASURING FACILITY with CI body flanged construction with EPDM coated disc with long pitch & PN 16 pressure rating with insulation, cladding over insulation, drain port, flanges, fittings, gasket, nuts, bolts, washer, all as specified and/or directed etc., complete. Note: This valve isrequired in condenser return line of Chiller.
Supply, erection, testing and commissioning of Ø125 mm NON - RETURN VALVE with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating including insulation, cladding over insulation, flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete. Note: This NRVs are required in discharge line for chilled water pumps.
Supply, erection, testing and commissioning of Ø150 mm NON - RETURN VALVE with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating with flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete. Note: This NRVs are required in discharge line for condenser water pumps.
Supply, erection, testing and commissioning of Ø100 mm NON - RETURN VALVE with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating including insulation, cladding over insulation, flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete. Note: This NRVs are required in discharge line for recirculation pumps.
Supply, erection, testing and commissioning of Ø80 mm NON - RETURN VALVE with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating including insulation, cladding over insulation, flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete. Note: This NRVs are required in discharge line for recirculation pumps.
Supplying, fixing, testing and commissioning of Motorized Butterfly Valve of Ø125 mm with CI Body, SS Disc, O - ring and PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC, and upto 20 mA electric signal and providing similar transduced feedback output to control system as required with insulation, cladding over insulation, flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete.
Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve of Ø150 mm with CI Body, SS Disc, O - ring and PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC, and upto 20 mA electric signal and providing similar transduced feedback output to control system as required with flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete.
Supply, erection, testing and commissioning of Ø150 mm Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer, flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete. Note: This strainer are required in suction line for condenser water pumps.
Supply, erection, testing and commissioning of Ø125 mm Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer, insulation, cladding over insulation, flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete. Note: This strainer are required in suction line for chilled water recirculation pumps.
Supply, erection, testing and commissioning of Ø100 mm Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer, insulation, cladding over insulation, flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete. Note: This strainer are required in suction line for chilled water recirculation pumps.
Supply, erection, testing and commissioning of Ø80 mm Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer, insulation, cladding over insulation, flanges, fittings, gaskets, nuts, bolts, washer all as specified and/ or directed etc. complete.Note: This strainer are required in suction line for chilled water recirculation pumps.
Supply, erection, testing and commissioning of 125 mm size 3 way motorised modulating valves with thermostat to be fitted in the outlet of cooling water coil, communication/ control cabling all as specified and/or directed etc., complete. Note: This valves are required for recirculation pumps line.
Supply, erection, testing and commissioning of 100 mm size 3 way motorised modulating valves with thermostat to be fitted in the outlet of cooling water coil, communication/ control cabling all as specified and/or directed etc., complete. Note: This valves are required for recirculation pumps line.
Supply, erection, testing and commissioning of 80 mm size 3 way motorised modulating valves with thermostat to be fitted in the outlet of cooling water coil, communication/ control cabling all as specified and/or directed etc., complete. Note: This valves are required for recirculation pumps line.
Providing and fixing Ø150 mm rubber bellows for connecting the chillers, pumps etc., to pipes all as specified and/ or directed etc., complete. Note: This rubber bellows are inrequired in inlets and outlets for Chillers, Pumps etc.
Providing and fixing Ø125 mm rubber bellows for connecting the chillers, pumps etc., to pipes all as specified and/ or directed etc., complete. Note: This rubber bellows are inrequired in inlets and outlets for Chillers, Pumps etc.
Providing and fixing Ø100 mm rubber bellows for connecting the chillers, pumps etc., to pipes all as specified and/ or directed etc., complete. Note: This rubber bellows are inrequired in inlets and outlets for Chillers, Pumps etc.
Providing and fixing Ø80 mm rubber bellows for connecting the chillers, pumps etc., to pipes all as specified and/ or directed etc., complete. Note: This rubber bellows are inrequired in suction and discharge for circulation pumps.
Supply, erection, testing and commissioning of automatic air vent with 20 mm ball valve with fittings all as specified and/or directed etc., complete
Supply, erection, testing and commissioning of pressure/ flow switches for the condenser/ chilled water line all as specified and or required etc., complete
Supply, fixing, testing and commissioning of 4" dia dial type temperature guage of range 0-50 0C at the inlet and outlet of chillers complete with necessary fittings, isolating valves all as specified and/or directed etc complete
Supply, fixing, testing and commissioning of 4" dia dial type pressure guage of range 0-10 Kg/cm2 at the inlet and outlet of chillers, AHUs complete with necessary fittings, isolating valves all as specified and/or directed etc complete
PART-B ELECTRICAL WORK
Supplying and fixing of 20mm dia size steel conduit pipes along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25mm dia size steel conduit pipes along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 20mm dia medium class PVC conduit pipes along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25mm dia medium class PVC conduit pipes along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 32mm dia medium class PVC conduit pipes along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing of 3 nos of 1.5 sqmm size FRLS 1.1KV PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing of 3 nos of 2.5 sqmm size FRLS 1.1KV PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing of 3 nos of 4.0 sqmm size FRLS 1.1KV PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing of 3 nos of 6.0 sqmm size FRLS 1.1KV PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 32 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5Cx240 sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with good soil after laying of cable/ pipe etc. in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meter.
Supplying and installation of Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying of all the required items and making Earthing with GI earth plate size 600 mm X 600 mm X 6 mm thick by providing charcoal/coke, Salt, 50x6mm GI strips from earth plate to terminals at top and other required accessories including all the civil works such as excavation, refilling, providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. at any kind of soil complete as per drawing and as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required including providing of suitable bimetal connectors for joints wherever required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required including providing of suitable bimetal connectors for joints wherever required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
Supplying and installing 150 mm width X 50 mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
Supplying and installing 150 mm width X 50 mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
Supplying and fixing of 20mm dia electrical grade steel wire reinforced PVC flexible condiut pipes with accessories.
Design, fabrication, supply, erection, testing and commissioning of indoor duty 415Volts, 50Hz, 3phase, 4wire duly wired electrical CHILLER PANEL having I/C& O/G feeders, instrumentation metering, protection system, SPD, aluminium busbars & other components completely as per single line diagram and as per detailed technical specifications. The panel shall be of modular type, floor mounting, free standing, vermin proof, indoor duty, IP-52 grade, made out of CRCA sheet steel, Powder coated painting, fuseless type confirming to relevent IS standards. The panel shall have a microprocessor based MCCB with shunt tripp for incoming and 2nos of TM based MCCBs for out going feeders. The work includes providing required fixing accessories such as grouting bolt-nuts, welding, coupling of laid conduits/ cables and associated civil works complete as directed. (Note:- Please refer drawing and DTS for complete Panel details)
Design, fabrication, supply, erection, testing and commissioning of indoor duty 415Volts, 50Hz, 3phase, 4wire duly wired electrical PUMP PANEL having I/C& O/G feeders, instrumentation metering, protection system, SPD, aluminium busbars & other components completely as per single line diagram and as per detailed technical specifications. The panel shall be of modular type, floor mounting, free standing, vermin proof, indoor duty, IP-52 grade, made out of CRCA sheet steel, Powder coated painting, fuseless type confirming to relevent IS standards. The panel shall have a microprocessor based MCCB with shunt tripp for incomer feeder and 15 nos of TM based MCCBs & 12 nos of star-delta motor starters for out going feeders. The work includes providing required fixing accessories such as grouting bolt-nuts, welding, coupling of laid conduits/ cables and associated civil works complete as directed. (Note:- Please refer drawing and DTS for complete Panel details)
Supplying of LT power cable with aluminium conductor, XLPE or PVC insulated, PVC inner sheathed, galvonise steel armoured, extruded PVC type ST2 sheathed, 1.1KV grade conforming to IS:7098(part-1) latest or IS:1554(part-1) latest having 3.5core of 240 SQMM size A2XFY or AYFY and laying of the same in the existing trenches/ duct/ pipe/ on the wall with suitable clamps, dressing etc., or as directed.
Supplying of LT power cable with COPPER conductor, XLPE or PVC insulated, PVC inner sheathed, galvonise steel armoured, extruded PVC type ST2 sheathed, 1.1KV grade conforming to IS:7098(part-1) latest or IS:1554(part-1) latest having 3.5core of 95 SQMM size 2XFY or CYFY and laying of the same in the existing trenches/ duct/ pipe/ on the wall with suitable clamps, dressing etc., or as directed.
Supplying of LT power cable with COPPER conductor, XLPE or PVC insulated, PVC inner sheathed, galvonise steel armoured, extruded PVC type ST2 sheathed, 1.1KV grade conforming to IS:7098(part-1) latest or IS:1554(part-1) latest having 3core of 16 SQMM size 2XFY or CYFY and laying of the same in the existing trenches/ duct/ pipe/ on the wall with suitable clamps, dressing etc., or as directed.
Supplying of LT power cable with COPPER conductor, XLPE or PVC insulated, PVC inner sheathed, galvonise steel armoured, extruded PVC type ST2 sheathed, 1.1KV grade conforming to IS:7098(part-1) latest or IS:1554(part-1) latest having 3core of 10 SQMM size 2XFY or CYFY and laying of the same in the existing trenches/ duct/ pipe/ on the wall with suitable clamps, dressing etc., or as directed.
Supplying of armoured control cable with COPPER conductor, XLPE or PVC insulated, PVC inner & outer sheathed, 1.1KV grade conforming to latest IS having 4core of 1.5 SQMM size and laying of the same in the existing trenches/ duct/ pipe/ on the wall with suitable clamps, dressing etc., or as directed.
Supplying and making end termination with brass compression gland and copper lugs for 3.5Cx95 sq.mm size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required.
Supplying and making end termination with brass compression gland and copper lugs for 3C or 4Cx16 sq.mm size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required.
Supplying and making end termination with brass compression gland and copper lugs for 3C or 4Cx10sq.mm size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required.
Cutting/breaking of Cement concrete flooring/road to required depth & width suitably by machine/mannualy for laying of pipes/ cables/ raceways etc., refilling with 1:2:4 cement concrete after the pipes/ cables/ raceways have been laid. The surface shall be plastered and made matching with existing surface. Removed debris shall be cleared from the site immediatly as directed. (Note:- earth excavation & refilling below CC flooring/ road shall be measured and paid separatly)
Supplying of suitable push button switches/station for remote operation of motors (ON-OFF) as shown in SLD of panels along with suitable sheet steel enclosure & all the required accessories and fixing of the same on the wall/colomun or already provided MS channel supports, making electrical connections etc complete as directed.
Releasing of the wall mounted Power distribution board of size up to 1.0Mtr (W) x 1.2Mtr (H) after disconnection of power supply and returning of the same to stores along with components/ switchgears of the panel, connected/ released cables etc as required.
Releasing of the floor mounted Power distribution board of size above 1.0Mtr (W) x 1.2Mtr (H) and up to 1.2Mtr(W) x 1.8Mtr(H) after disconnection of power supply and returning of the same to stores along with components/ switchgears of the panel, connected/ released cables etc as required.
Releasing of the floor mounted Power distribution board of size above 1.2Mtr (W) x 1.8Mtr (H) and up to 2.0Mtr(W) x 2.5Mtr(H) after disconnection of power supply and returning of the same to stores along with components of the panel, connected/released cables etc as required.
PART C - CIVIL WORK
Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering,shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge All works above plinth level upto floor V level
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more (Basic rate of Steel is considered as Rs.46.00 per kg)
Shifting of existing Chiller (1 No of capacity 85TR), Pumps (6Nos), with associated electrical, control etc. complete including loading/ unloading from the site to BEL Disposal (within 2kms from the site) under the instruction of the BEL Engineer in charge
Dismantling of shifting of existing piping, valves, Electrical panel, cable, conduit & accessories, structural supports etc. complete including loading/ unloading from the site to BEL Disposal (within 2kms from the site) under the instruction of the BEL Engineer in charge
SNOWMEX ENGINEERS LIMITED
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .