Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC 86 CHAK16 QAZIPURA TANDA RAMPUR UTTAR PRADESH 244925 | RAMPUR | UTTAR PRADESH | 244925 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹32.7 L+₹1.9 L (6.07%)Rejected-Finance | L2 | Rejected-Finance NOT REASONABLE | |
| 3 | L3₹34.6 L+₹3.8 L (12.3%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance NOT REASONABLE | |
| 4 | L4₹34.6 L+₹3.8 L (12.5%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L4 | Rejected-Finance NOT REASONABLE | |
| 5 | L5₹36.7 L+₹5.9 L (19.1%)Rejected-Finance | L5 | Rejected-Finance NOT REASONABLE |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
28 Sept 2024, 6:00 pmClosed
Saurabh Gupta, EE
GE (W) Colaba, Mumbai
SPECIAL REPAIRS TO ROOF ,JOINERY AND STRUCTURAL MEMBERS OF BLDG NO P-03 CAMP UNDER GE (W) COLABA, MUMBAI
2024_MES_668189_1
8913/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹98,000
Yes
23 Dec 2024
30 Aug 2024
30 Sept 2024
30 Aug 2024
28 Sept 2024
14 Sept 2024
Amount
S&F in repairs to replace old or decayed boarding in patches including cutting out old, piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including scafoldings of any hieght complete all as specified and directed.
Fixing only in repairs in patches including cutting out old, piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including scafoldings of any height all as specified and directed.
M&L in repairs to replace old or decayed boarding in patches including cutting out old, piecing, heading joints etc second class hardwood wheather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps in any situation including scafoldings of any height all as specified and directed.
Fixing only in repairs in patches including cutting out old, piecing, heading joints etc second class hardwood wheather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps in any situation including scafoldings of any height all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar patteren roof coverings including scafoldings of any height all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, eaves etc fixed with self tapping screws all as specified and directed.
S&F for joist, channel, angle or tee section fixed indpendently, without connecting plates confirming to Fe 410 -W (Gde- E- 250) quality- A including welding, nuts and bolts all as specified and directed.
M&L in repairs to replace old decayed timber (including piecing, scarifying, etc of old and new timber if required) second class hard wood clean sawn in scantlings timber framed and fixed in any position and description including scafoldings of any hieght all as specified and directed.
Demolition of cement concrete in ground floor n.exc 15cm thickness (below or above ground level) and removing the demolished material and debrise out side MD land all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection, flooring/subbase including necessary shuttering all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust & brushing neat cement slurry with 3.0 kg of cement per sq mtr all as specified and directed.
M&L for non skid ceramic digital HD Polished coloured ceramic tiles 7 to 8 mm thick square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm in floors etc. set and jointed in neat cement slurry laid over 15 mm thick screed bed in cement mortar 1:6 and pointed in white or coloured cement to match all as specified and directed.
M&L Non Skid digital HD Polished coloured ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over rendering 10 mm thick on fair faces of brick work in CM (1:4) all as specified and directed.
M&L for non /anti skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but not exc 0.11 sqm in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick laid over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish inluding Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes all as specified and directed.
All as per above Item No 17 above but in riser of steps, skirting, dado and pillar laid over cement screed and jointed over rendering 10 mm thick on fair faces of brick work in CM (1:4) all as specified and directed.
S&F POP false ceiling consisting of frame work made with 50 mm Sq MS tube of 18 G thickness as main runner at 600 mm c/c both ways suspended/supported with MS flats 25x4 from existing RCC slab including providing and fixing expanded metal of size 5.25 mm x 1.25 mm thickness welded to main runners and applying POP (calcium silicate semihydrate variety) to the expended metal of thickness not less than 10 mm finished smooth to line and level including necessary supports scaffolding etc as required and also including applying a coat of red oxide zinc chrome primer over the MS frame work and suspended all as specified and directed
Cleaning existing reinforcement with wire brush/ rotary wire brush to make surface free from rust, scales, loose material, dirt etc. complete and providing, applying two coats of alkaline rust converting primer confirming to ASTMB- 117, on the existing rebars and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 1 hour between the coats all as specified and directed
Providing and application of full and unbroken coating of anticorrosive protective zinc rich epoxy coating on exposed reinforcement in two coats with time interval of minimum 1 hours between each coat including mixing of both componants by weight as per mfg specifications, brush application, curing to form a anticorrosive protective coating with high mechanical strength to cementitious repair works all as specified and directed
Rebuilding the section of damaged RCC elements to its original size or as per consultants recommandations in thicknesses of 40-100 mm by providing and casting with micro concrete of grade M-40 and above including providing and fixing of watertight foam faced finish shuttering of minimun 18 mm thick with supporting framework, all lead lift, mixing, placing, deshuttering, levelling the surface by grinding off cementious slurry or construction joint differences if any to the satisfaction of engineer in charge, curing etc. complete. (Rate including- cube test to be conducted for every 5 M.T. work done.6 no's of sample required per test). Ensure the quality of water by testing water as per IS 456 and document the same. Ensure temperature at time of mixing should be between 25 to 40 degree celcius by electronic temperature gauge all as specified and directed
Rebuilding the section of damaged RCC elements to its original size or as per consultants recommandations in thicknesses up to 40 mm in layers of 20 mm each by providing and applying with hand, single component shrinkage compensated thixotropic mortar of grade M40 and above, including all lead lift, mixing by addition of water only as per manufacture's recommendation, levelling the surface, curing etc. complete. (Rate including- cube test to be conducted for every 5 M.T. work done.6 no's of sample required per test) Ensure the quality of water by testing water as per IS 456 and document the same. Ensure temperature at time of mixing should be between 25 to 40 degree celcius by electronic temperature gauge all as specified and directed
Mixing and applying SBR latex modified cementious bond coat using cement 2.2 kg per square metre on prepared concrete surfaces of parent material all as specified and as directed. (Note: SBR latex shall be paid for separately).
Supply only approved SBR latex for bonding coat all as specified and directed. Note: Rate shall be in terms of solid contents of polymer).
Mixing and applying SBR latex modified cement mortar 25 mm thick in cement and sand mortar in proportions of 1:3 (1 cement and 2 graded quartz aggregate) with polymer admixed in proportions as approved, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed Note: Acrylic polymer shall be paid for separately
M&L mild steel TMT bars 8-10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height all as specified and directed.
M&L mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and as directed
Providing and fixing special water tight centering and shuttering including bolting, strutting, propping etc. so as to with stand a pressure of 0.1 Mpa including removal of form work at all locations including beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises out side MD land all as specified and directed.
M&L for Glazed ceramic tiles 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces (including designed borders ) such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match and laid over rendering 10 mm thick on fair faces of brick work in CM (1:4) all as specified and directed. Note:- (Rate of Designer border in vertical surface shall be deemed to be included into quoted rate)
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site out side MD land all as specified & directed.
M&L Granite (of any type and colour) 20 mm thick machine cut , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid in floors/Jambs/WHB conters and all other similar works in approved design laid over 20 mm thick screed bed in cement mortar 1:4 all as specified and directed.
Dismantling of ceiling board (Pulp insulation or insulation etc) or insulation board any thickness including cover fillet and grid frame work all as specified and directed
M&L GI powder coated frame work for seamless ceiling 600x600mm grid size comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre all as specified and directed.
M&L for 6 mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous materials reinforced with cellulose fibre for fixing in 605 X 605 mm grids all as specified and directed. Note:- Frame work for ceiling shall be measured and paid separately.
Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water all as specified and directed
M&L 15 mm thick cement plaster in CM (1:6) on brick work/ RCC wall and finished surfaces fair and even without using extra cement all as specified and directed.
Supply only integral waterproofing compound
M&L for two coats of oil bound distemper over 1 mm thick wall care putty on new plastered surfaces including preparation of surface all as specified and directed.
M&L for two coats of oil bound distamper over 1 mm thick wall care putty on old plastered surfaces including preparation of surface with complete removal of existing treatment all as specified and directed.
Providing & applying anti algal water-based Elastomeric exterior wall finish on newly plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per Litre coverage area ) & of paint by roller all as specified and directed.
Providing & applying anti algal water-based Elastomeric exterior wall finish on old plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per litre coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per Litre coverage area ) & of paint by roller all as specified and directed.
M&L for preparation of new wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of primer all as speciefied & directed .
M&L for preparation of old painted wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint all as apecified and directed
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel painting over one coat of red oxide zinc chrome primer all as apecified and directed
M&L 2 coats of synthetic enamel painting over a coat of red oxide primer including preperation of steel surfaces of any description nexc 10 cm width or girth all as specified and directed.
M&L for one coat of synthetic enamel painting on old steel surfaces including preparation of surface of any description, over 10cm in width or girth, not otherwise described all as apecified and directed.
Taking down chowkhats or frames area exc 1.5 sqm but n exc 4 sqm each with shutters (without taking off shutters from the frame) all as apecified and directed .
Taking down chowkhat with shutter area not exc 1.5 sqm each (without taking off shutters from the frames) all as specified and directed
Taking down shutters of any description area exc. 1.00 Sqm but nexc 2.00 Sqm all as spcified and directed.
Taking down shutters of any description area nexc. 1.00 Sqm all as spcified and directed.
Resecuring or easing & adjusting without taking down shutter area exc 1 sqm but nexc 2 sq. m each all as specified & directed
S&F 2nd class hard wood plain solid straight chowkhat and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint all as specified and directed.
S&F 35 mm thick 2nd class hard wood rail and style plain framed panelled shutters (any panel) with lock rail and panel of 9 mm thick B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated all as specified and directed.
S&F shutter of 2nd class hard wood 35mm thick Glazed and skelton shutters, open rebated and prepared to receive glass, gauge, etc. (without sash bars) edges of framing plain, chamfered or rounded, fittted with cut and mitred beads for securing gauge, etc. sizes of member of shutter as specified SSR part-I Section 8 clause 8.24 (a) all as specified and directed.
S&F 35 mm thick flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both sides all as specified and directed.
S&F 2nd class HW Glazed and skeleton shutters for windows of 25 mm thickness, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) as specified and directed.
S&F powder coated/anodised aluminium sections for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazing clips, provn of AC opening and rubber beadings for fixing glass panes in frame all as apecified and directed Note : (i) Glass panes will be measured & paid separately . (ii) The quoted rate shall be inclusive of cost of rubber beading and glazing clips, hinges, handle. However it will not be weighed and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 62 mm x 32 mm size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold unserviceable fast/lugs/SS dash fasteners of required dia and length all as specified and as directed.
S&F factory made 28-30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size, modulus of elasticity 850 N/mm” and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws all as specified and as directed.
S&F sheet glass ordinary quality 3 mm thick not exc 0.50 Sqm in each panes and glazing with oil putty all as specified and directed..
S&F in repairs sheet glass ordinary quality 3 mm thick not exc 0.50 Sqm in each panes and glazing with oil putty, wooden beads all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
S&F in repairs floor door stopper of aluminium alloy body and tongue, length of leg 140 mm, anodised, with hard drawn steel spring and fubber foot all as specified and directed.
S&F extruded aluminium alloy handles 150 mm fabricated type, anodized all as specified and directed.
S&F extruded aluminium alloy barrel tower bolts with bright bolt and fixed of size 200 mm for doors all as specified and directed.
S&F aluminium anodised, barrel tower bolts of extruded section and fixed of 150 mm size all as specified and directed.
S&F butt hinges of size 100 mm, medium weight, stainless steel min 3 mm thick for doors all as directed by Engr-in-Charge
S&F in repairs Stainless Steel drapery rod (1 mm thick stainless steel section outer dia 25 mm with bracket, ring & fancy side holders all as specified and directed.
Demolition of brick masonary built in cement mortar all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cm (1:6) all as specified and directed.
Taking up or down 15mm dia steel tubing and connections, including cleaning for refixing or removal to store all as specified and directed.
S&F 15mm dia steel tubes, 'medium grade' galvanised, with all fittings and fixed complete incuding cutting chasing pinning and making good to walls and ceilings or laid in floors all as specified and directed.
Refixing old 15mm dia steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) all as specified and directed.
Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal to store all as specified and directed.
S&F 20mm dia steel tubes, 'medium grade' galvanised, with all fittings and fixed complete including cutting chasing pinning and making good to walls and ceilings or laid in floors all as specified and directed.
Refixing old 20mm dia steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) all as specified and directed.
Taking down rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc. removal to Store (measured overall as fixed along the centre line over fittings and accessories) all as specified and directed.
S&F PVC (SWR) 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts all as specified and directed.
S&F 110mm dia PVC (SWR) bends any radius all as specified and directed.
S&F 75 mm dia PVC (SWR) bends any radius all as specified and directed.
S&F 110 mm PVC (SWR) junction single, (Single T) equal or unequal all as specified and directed.
S&F 75 mm PVC (SWR) junction single, (Single T) equal or unequal all as specified and directed.
S&F 110 mm PVC (SWR) junction single, (Single Y) equal or unequal all as specified and directed.
S&F 75 mm PVC (SWR) junction single, (Single T) equal or unequal all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and directed..
S&F in repairs PVC (SWR) floor trap 75 mm, plain with CP grating including joining and solvent cement all as specified and directed.
S&F in repairs tubular towel rail brass chromium plated, 20mm dia, 60cm long between flanges all as specified and directed.
S&F in repairs 15 mm dia brass CP fancy wall mixer with L Bend (including provision of O/H shower & hand shower) for mixing hot & cold water screwed down for iron pipe and fixed with hand shower HSH-1717 and tube all as specified and directed.
S&F in repairs 15 mm dia brass CP centre hole basin mixer for mixing hot & cold water screwed down for iron pipe all as specified and directed.
S&F in repairs 15 mm bore gun metal gate valve cast copper alloy, screwed down high pressure with wheel head, screwed both ends with crutch or butterfly handle for iron pipes all as specified and directed.
S&F in repairs Vitreous China Wash hand basin, white, oval shape, size 580 mm x 450 mm size, SLS-WHT-0611F, excluding taps, chain & plug & porcelain stopper but including brackets, 40/32 mm dia PVC waste pipe, PVC connection, chromium plated coupling 32 mm dia, approved pedestal SLS-WHT-1510 & cutting for and pinning ends of brackets or erecting stand all as specified and directed.
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including P or S trap (excluding flushing cistern and flush pipe) all as specified and directed.
S&F in repairs Vitreous China half stall urinals, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, magnum urinal spreader, pointing around urinal back in cement; flush pipe, grating and Union for discharge pipe all as specified and directed.
S&F 50 mm dia low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm fixed complete to walls, ceiling or in floors etc including cutting, chasing, pinning and making floor good with existing one all as specified and directed.
S&F in repairs PVC valve less syphonic action type flushing cistern low level white, dual flush, ISI marked (IS: 7231) with PVC inlet ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection and 32mm dia PVC long bend for squatt pattern etc, set with concrete and making good to floor all as specified & directed.
S&F in repairs Soap dish all as specified & directed .
S&F in repairs 15mm bore, chromium plated bib taps cast copper alloy with crutch or butterfly handle screwed down for iron pipe all as specified & directed.
S&F in repairs fancy type chromium plated 15 mm bore stop valve/angle cock cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed.
S&F in repairs Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union alongwith arm 225mm and flange all as specified and directed..
Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling all as specified and directed.
M&L for Point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volts grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, in casing caping with accessories and incuding provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volts grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches, socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately.
All as per Srl item No.106 here in before but for ceiling fan controlled by one switch.
All as per Srl item No.106 here in before but for socket outlet point 5 Amp on same board.
All as per Srl item No.3 here in before but for socket outlet point 5 Amp on Independent board.
All as per serial item No 106 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) all as specified and directed. Note: Earthing wire should also be 4 Sqmm
S&F switch piano (ISI marked) Single pole 240 volts, 5 Amps all as specified and directed.
S&F socket (ISI marked) 2/3 pin and 5 Amps, flush type, 240 volts all as specified and as directed.
S&F switch socket combination (ISI marked) 2/3 pin and 5/15 Amps, flush type, 240 volts all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet all as specified and directed.
S&F ceiling rose surface bakelite 65x50mm, 3 terminal all as specified and directed.
S&F in repairs Modular type AC Box, 4 Module with Socket and 20 Amp SP mini MCB in plastic box enclosure along with cover plate and top all as specified and directed.
S&F LED light fitting 1x9W/1X10W luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed.
S&F in repairs 20 watt LED, 6500 K, 4 feet long fixed including on pvc square for mounting the fittings and electrically connecting with three single core 23/0.0076. PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting (connector block of lamp fitting) and one for earthing all as specified and directed
S&F recesss mounted low glare luminaire 40 watt 2 X 2 complete with all accessories all as specified and directed.
S&F Exhaust fan 230 volts, 600mm, metal heavy duty with wooden frame including making all electric connection including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall all as specified and directed.
S&F Exhaust fan 230 volts, 300 mm, metal heavy duty with wooden frame including making all electric connection including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall all as specified and directed.
M&L refixing of ceiling fan (old fan) and connecting up including provision of cable from ceiling rose or connector and fan Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust, replacement of defective parts and replacing it with new one including aluminium blades of superior quality, canopies and bearing etc. in order to make ceiling fan smooth in operation with taking down fan, sealing cable end, dismantling romoving and hanging fan with rod of required length and proper hook and blades and removing fan and blades to store all as specified and directed. Note: Connection should be made neatly using two core white flexible cable.
S&F LED security Building light LED 35/45 Watt, pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light all as specified and directed.
S&F in repairs MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection all as specified and directed. Make: Legrand/ Indo Asian
S&F in repairs MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series all as specified.
S&F in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's all as specified and directed.
S&F MCCB DB TPN 8 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, single door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting all as specified and directed. Note : MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule . Note : Copper thimble shall be used for connection of cable .
S&F in repairs MCCB TPN, 240 Volts, 63 to 100 Amps, 10 kA rupturing capacity 415 Volts all as specified and directed.
Taking down carefully copper/aluminum sub main wiring including all fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces all as specified and directed
M&L Sub main wiring in conduit, with two run of 6 sq mm stranded copper conductor PVC unsheathed FRLSH wire along with 6 sq mm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 32 mm dia) for housing the wires for from Pannel / Main DB to house SPN DB including taking down old Unsv submain with all associated fixtures all as specified & as directed. Note: 1) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. 2) Mode of measurement two runs of 6 sqmm cable and one run of 6 sqmm cable with PVC conduit shall be measured as one length.
M&L Sub main wiring with two run of single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia in conduit ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM.
M&L for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm burried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth GI strip 25X4 mm by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm c/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil including necessary testing all as shown in Electrical Plate No 3 of SSR part -I.
RUPESH CONSTRUCTION CO (BID ID -3105174)
ASHOK CONSTRUCTION (BID ID -3104268)
Unitech Enterprises (BID ID -3102774)
Panther Facilities (BID ID -3103467)
HINDUSTAN BUILDERS (BID ID -3101165)
GANGAJAL (BID ID -3099707)
Bidder Name
Unitech Enterprises
HINDUSTAN BUILDERS
ASHOK CONSTRUCTION
Panther Facilities
GANGAJAL
RUPESH CONSTRUCTION CO
N F ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .