Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹10.0 L | L1 | Accepted-AOC Being lowest Bidder |
| 2 | L2₹10.4 L+₹46,897 (4.71%)Rejected-AOC NEAR LIC OFFICE KALAIGNAR ARIVALAYAM SHOP ROOM NO7 GROUND FLOOR OF BACK SIDE PHOENIX BAY SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹10.4 L+₹46,897 (4.71%) | L2 | Rejected-AOC Being L2 |
| 3 | L3₹10.6 L+₹60,254 (6.05%)Rejected-AOC | ₹10.6 L+₹60,254 (6.05%) | L3 | Rejected-AOC Being L3 |
| 4 | L4₹10.6 L+₹63,691 (6.39%)Rejected-AOC | ₹10.6 L+₹63,691 (6.39%) | L4 | Rejected-AOC Being L4 |
| Sl No | Description | Qty | Unit | M/s Karbhagam Sales Agency L4 | Tropical Refrigeration L1 | RK TRADERS L2 | Everest Cooling Works L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for taking out existing unserviceable scroll compressor and replace with new compressor suitable for working on 380-415V 3 phase , 50Hz, LR : 87A, having lubricant : PVE / 1.6 L suitable for R-407C refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified.
Make-Danfoss scroll compressors Model No- HLP072T4LC6 or equivalent. | 1 | EACH | 79,200 ₹79,200 | 78,000 ₹78,000 Lowest | 78,500 ₹78,500 | 79,200 ₹79,200 |
| 2.00 | M&L for taking out existing unserviceable scroll compressor and replace with new compressor suitable for working on 220-240 V 1 phase, 50 Hz, suitable for R-22 refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing, vacuum the system and charging suitable refrigerant gas and testing after replacement complete all as specified.
Make - EMERSON Copeland scroll compressors Model No-CR22K6M-PF1-111DM or equivalent. | 1 | EACH | 79,200 ₹79,200 | 78,000 ₹78,000 Lowest | 78,500 ₹78,500 | 79,650 ₹79,650 |
| 3.00 | M&L for taking out existing unserviceable scroll compressor and replace with new compressor suitable for working on 415 V 3 phase , 50Hz, suitable for R-404a refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified.
Make-Danfoss scroll compressors Model No- ZB21KQE-TFD-524/ ZF15KQE-TFD 551 or equivalent. | 1 | EACH | 84,700 ₹84,700 | 82,500 ₹82,500 Lowest | 82,650 ₹82,650 | 84,500 ₹84,500 |
| 4.00 | M&L for replacement of unserviceable blower motor 3 Phase, 415 V, 50 HZ, 0.75-1 HP 1400 RPM, S1 duty, Frame-80 of air cooled AC plant (5.5 TR) as per existing make, model and type complete all as directed by Engr-in-charge. | 2 | EACH | 7,350 ₹14,700 | 7,000 ₹14,000 Lowest | 7,120 ₹14,240 | 7,325 ₹14,650 |
| 5.00 | S&F in replacement of blower belt of AHU / Compressor belts as per existing model and type ISI marked including re-alignment of the motor and blower if required for proper tension of belts as directed by Engr-in-charge. | 10 | EACH | 798 ₹7,980 | 750 ₹7,500 Lowest | 760 ₹7,600 | 780 ₹7,800 |
| 6.00 | S&F existing fan motor with blade of outdoor condenser unit of air cooled package/ central type AC plant (5 to 7.5TR) | 2 | EACH JOB | 8,250 ₹16,500 | 8,000 ₹16,000 Lowest | 8,100 ₹16,200 | 8,250 ₹16,500 |
| 7.00 | Supply and filling/topping up refrigerant gas R-22/R134a/R-404A/R-407C/410A/R-507/R-513A in scroll compressors of package type AC plants of any capacity as per OEM specification including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.
Make : Mefron/Floron/Refron.
Note :- The rates quoted by the contractor for topping up/ filling of refrigerant gas shall deemed to include leakage detection, rectification of leakage by brazing, nitrogen pressure testing, etc. | 107 | KG | 3,250 ₹3,47,750 | 2,950 ₹3,15,650 Lowest | 3,050 ₹3,26,350 | 3,250 ₹3,47,750 |
| 8.00 | M&L for Servicing outdoor units & ducting of air cooled central/ Package type AC plant 5.5 TR through OEM service Engineer having min 5 yrs. experience by cleaning of cooling coil by using chemical if reqd, including combing of fins by using fins comb to making straight the fins, checking all electrical & control wiring, servicing, oiling of blower motor, etc. complete as specified by OEM and directed by Engr-in-charge.
Make of installed plant- Blue Star | 2 | EACH JOB | 7,450 ₹14,900 | 7,250 ₹14,500 Lowest | 7,300 ₹14,600 | 7,450 ₹14,900 |
| 9.00 | Labour only for servicing of Main Electric Panel board / Control panel board of Central / Package type AC Plant by cleaning the panel with blower, replacement of unserviceable burnt wire, cables with existing size & length including proper numbering, replacement of u/s fuse link, lugs, washer, nuts, bolts, checking proper electrical connection, connectivity etc. & find out defective parts and making the panel functional by replacing the unserviceable item (taken as supply only) as directed by Engr-in-charge.
Note : -
(i) Unserviceable parts as MCB, MCCB, contactor, relay, MPD, etc. will be measure and paid separately under relevant items of BOQ at supply only rates.
(ii) Minor parts like thimbles, tags, nut, bolts, washers etc shall be deemed to be included in rate quoted against this item. | 2 | EACH JOB | 3,120 ₹6,240 | 2,800 ₹5,600 Lowest | 3,000 ₹6,000 | 2,990 ₹5,980 |
| 10.00Supply only the following for above items (Make- Hager/Legrand/C&S/L&T/Merlin Gerin) | |||||||
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
18 Jun 2026, 6:00 pmClosed
CWE CARNICOBAR
HQ CWE Carnicobar c/o 99 APO
REPAIR MAINTENANCE OF ALL TYPE AC COLD STORAGE PLANTS AND ITS PERIODICAL MAINT AT AIR FORCE STATION CAR NICOBAR
2026_MES_766433_2
81005/E8
Open Tender
Civil Works
Item Rate
Carnicobar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE 866 EWS
₹20,000
Yes
30 Jul 2026
4 Jun 2026
20 Jun 2026
4 Jun 2026
18 Jun 2026
12 Jun 2026
5 Jun 2026 - 10 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for taking out existing unserviceable scroll compressor and replace with new compressor suitable for working on 380-415V 3 phase , 50Hz, LR : 87A, having lubricant : PVE / 1.6 L suitable for R-407C refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified.
Make-Danfoss scroll compressors Model No- HLP072T4LC6 or equivalent. | 1 | EACH | - | - |
| 2 | M&L for taking out existing unserviceable scroll compressor and replace with new compressor suitable for working on 380-415V 3 phase , 50Hz, LR : 87A, having lubricant : PVE / 1.6 L suitable for R-407C refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified.
Make-Danfoss scroll compressors Model No- HLP072T4LC6 or equivalent. | 1 | EACH | - | - |
| 3 | M&L for taking out existing unserviceable scroll compressor and replace with new compressor suitable for working on 415 V 3 phase , 50Hz, suitable for R-404a refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified.
Make-Danfoss scroll compressors Model No- ZB21KQE-TFD-524/ ZF15KQE-TFD 551 or equivalent. | 1 | EACH | - | - |
| 4 | M&L for replacement of unserviceable blower motor 3 Phase, 415 V, 50 HZ, 0.75-1 HP 1400 RPM, S1 duty, Frame-80 of air cooled AC plant (5.5 TR) as per existing make, model and type complete all as directed by Engr-in-charge. | 2 | EACH | - | - |
| 5 | S&F in replacement of blower belt of AHU / Compressor belts as per existing model and type ISI marked including re-alignment of the motor and blower if required for proper tension of belts as directed by Engr-in-charge. | 10 | EACH | - | - |
| 6 | S&F existing fan motor with blade of outdoor condenser unit of air cooled package/ central type AC plant (5 to 7.5TR) | 2 | EACH JOB | - | - |
| 7 | Supply and filling/topping up refrigerant gas R-22/R134a/R-404A/R-407C/410A/R-507/R-513A in scroll compressors of package type AC plants of any capacity as per OEM specification including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.
Make : Mefron/Floron/Refron.
Note :- The rates quoted by the contractor for topping up/ filling of refrigerant gas shall deemed to include leakage detection, rectification of leakage by brazing, nitrogen pressure testing, etc. | 107 | KG | - | - |
| 8 | M&L for Servicing outdoor units & ducting of air cooled central/ Package type AC plant 5.5 TR through OEM service Engineer having min 5 yrs. experience by cleaning of cooling coil by using chemical if reqd, including combing of fins by using fins comb to making straight the fins, checking all electrical & control wiring, servicing, oiling of blower motor, etc. complete as specified by OEM and directed by Engr-in-charge.
Make of installed plant- Blue Star | 2 | EACH JOB | - | - |
| 9 | Labour only for servicing of Main Electric Panel board / Control panel board of Central / Package type AC Plant by cleaning the panel with blower, replacement of unserviceable burnt wire, cables with existing size & length including proper numbering, replacement of u/s fuse link, lugs, washer, nuts, bolts, checking proper electrical connection, connectivity etc. & find out defective parts and making the panel functional by replacing the unserviceable item (taken as supply only) as directed by Engr-in-charge.
Note : -
(i) Unserviceable parts as MCB, MCCB, contactor, relay, MPD, etc. will be measure and paid separately under relevant items of BOQ at supply only rates.
(ii) Minor parts like thimbles, tags, nut, bolts, washers etc shall be deemed to be included in rate quoted against this item. | 2 | EACH JOB | - | - |
| 10Supply only the following for above items (Make- Hager/Legrand/C&S/L&T/Merlin Gerin) | |||||
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Tender.pdf
Tender Documents • 1.22 MB
BOQ_862105.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .