| 1 | L1₹8.7 CrAccepted-AOC PARISHRAM MADAN MAHAL CHOWK NAGPUR ROAD JABALPUR 248001 | JABALPUR | DEHRADUN | UTTARAKHAND | 248001 | ₹8.7 Cr Quoted ₹8.8 Cr | L1 | Accepted-AOC BEING THE LOWEST BIDDER |
| 2 | L2₹10.2 CrRejected-Finance SIBAL NIWAS BAGADGANJ POST OFFICE NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | ₹10.2 Cr | L2 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 3 | L3₹11.1 CrRejected-Finance | ₹11.1 Cr | L3 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 4 | L4₹11.1 CrRejected-Finance | ₹11.1 Cr | L4 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 5 | L5₹11.6 CrRejected-Finance NO 16 7 739 3RD FLOOR OSMANPURA CHADERGHAT HYDERABAD TELANGANA 500 024 | HYDERABAD | HYDERABAD | TELANGANA | 500024 | ₹11.6 Cr | L5 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | KAIZEN INDUSTRIES L6 | SETH CONSTRUCTION COMPANY L3 | INDUS ENGG AND CONST CO L4 | SATYA PRAKASH BUILDERS LTD L1 | SIBAL AND SIBAL L2 | Accurate Power Systems L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Lumpsum price worked out by the contractor for “BUILDINGS AND STRUCTURES” as listed in Sch 'A' part I above/below the lumpsum price of Rs.7,10,45,000.00 as inserted by MES for Sch ‘A’ part I on srl page No. 31(R) | 1 | LUMP SUM | 9,65,00,000 ₹9.7 Cr | 9,00,00,000 ₹9 Cr | 9,00,00,000 ₹9 Cr | 6,93,11,000 ₹6.9 Cr | 8,45,47,554.9 ₹8.5 Cr | 9,45,75,000 ₹9.5 Cr |
| 2.00 | Lumpsum price worked out by the contractor for “SITE CLEARANCE/ EARTHWORK” as listed in Sch '‘A” part II above/below the lumpsum price of Rs.9,34,685.88 as inserted by MES for Sch ‘A’ part II on srl page No.32(R) | 1 | LUMP SUM | 9,90,000 ₹9.9 L | 11,28,154 ₹11.3 L | 10,18,807 ₹10.2 L | 8,37,000 ₹8.4 L | 7,64,292.64 ₹7.6 L | 9,75,000 ₹9.8 L |
| 3.00 | Lumpsum price worked out by the contractor for “DEMOLITION OF B/R PORTION” as listed in Sch '‘A” part IIIA above/below the lumpsum price of Rs. 17,85,268.79 as inserted by MES for Sch ‘A’ part IIIA on srl page No.34 | 1 | LUMP SUM | 19,90,000 ₹19.9 L | 22,99,501 ₹23.0 L | 21,06,617 ₹21.1 L | 17,85,269 ₹17.9 L | 14,59,814.29 ₹14.6 L | 20,75,000 ₹20.8 L |
| 4.00 | Lumpsum price worked out by the contractor for “DEMOLITION OF E/M PORTION” as listed in Sch '‘A” part-IIIB above/below the lumpsum price of Rs. 97,855.60 as inserted by MES for Sch ‘A’ part IIIB on srl page No.35 | 1 | LUMP SUM | 1,09,000 ₹1.1 L | 1,22,534 ₹1.2 L | 1,07,641 ₹1.1 L | 97,855 ₹97,855 | 86,866.42 ₹86,866.42 | 1,07,500 ₹1.1 L |
| 5.00 | Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY" as listed in Sch ‘A” part IV representing above/below the lumpsum price of Rs. 5,09,602.80 inserted by MES for Sch ‘A’ Part IV on srl page No.36(R) | 1 | LUMP SUM | 6,09,000 ₹6.1 L | 5,21,715 ₹5.2 L | 6,31,907 ₹6.3 L | 7,11,000 ₹7.1 L | 5,15,870.91 ₹5.2 L | 5,75,000 ₹5.8 L |
| 6.00 | Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION" as listed in Sch ‘A” part V representing above/below the lumpsum price of Rs. 16,66,153.15 inserted by MES for Sch ‘A’ Part V on srl page No.38 | 1 | LUMP SUM | 18,00,000 ₹18 L | 17,49,460 ₹17.5 L | 19,99,383 ₹20.0 L | 18,11,000 ₹18.1 L | 14,95,705.68 ₹15.0 L | 17,75,000 ₹17.8 L |
| 7.00 | Lumpsum price worked out by the contractor for “ROAD/ PATH/ CULVERT/ HARDSTANDING” as listed in Sch ‘A” part VI representing above / below the lumpsum price of Rs. 26,34,985.34 as inserted by MES for Sch ‘A’ Part VI on srl page No.40(R) | 1 | LUMP SUM | 27,00,000 ₹27 L | 30,30,233 ₹30.3 L | 28,98,483 ₹29.0 L | 25,77,000 ₹25.8 L | 26,67,395.66 ₹26.7 L | 27,75,500 ₹27.8 L |
| 8.00 | Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL” as listed in Sch ‘A” part VII representing above / below the lumpsum price of Rs. 3,57,700.96 as inserted by MES for Sch ‘A’ Part VII on srl page No.42 | 1 | LUMP SUM | 4,00,000 ₹4 L | 4,29,242 ₹4.3 L | 4,07,779 ₹4.1 L | 4,11,000 ₹4.1 L | 3,65,677.69 ₹3.7 L | 4,75,000 ₹4.8 L |
| 9.00 | Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Sch ‘A” part VIII representing above / below the lumpsum price of Rs.6,40,489.18 as inserted by MES for Sch ‘A’ Part VIII on srl page No.43 | 1 | LUMP SUM | 7,50,000 ₹7.5 L | 7,68,587 ₹7.7 L | 7,42,967 ₹7.4 L | 6,11,000 ₹6.1 L | 6,54,772.09 ₹6.5 L | 7,75,000 ₹7.8 L |
| 10.00 | Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Sch ‘A” part IX representing above / below the lumpsum price of Rs.3,19,716.82 as inserted by MES for Sch ‘A’ Part VIII on srl page No.44 | 1 | LUMP SUM | 4,10,000 ₹4.1 L | 4,31,617 ₹4.3 L | 4,22,026 ₹4.2 L | 4,11,000 ₹4.1 L | 4,00,381.37 ₹4.0 L | 3,75,500 ₹3.8 L |
Updated dates
Tender Value
₹8.6 Cr
EMD Value
₹7.5 L
Closing Date
26 Mar 2026, 9:00 amClosed
Chief Engineer(AF) Nagpur
HQ CE (AF) Nagpur-07
RECONSTRUCTION OF CERTAIN MD ACCN AT VAYUSENA NAGAR UNDER GE AF NAGPUR
2025_MES_741017_3
AF_NGP_801247
Open Tender
Civil Works
540 days
GE AF NAGPUR
For MES Enlisted Contractors- Class S Category a (i) For other Contractor meeting enlistment Criteria of MES for Class S Category a (i)
7 documents required · 7 mandatory
₹3,000
GE AF NAGPUR
₹7.5 L
Yes
18 May 2026
5 Mar 2026
27 Mar 2026
5 Mar 2026
26 Mar 2026
12 Mar 2026
5 Mar 2026 - 12 Mar 2026
Lumpsum price worked out by the contractor for “BUILDINGS AND STRUCTURES” as listed in Sch 'A' part I above/below the lumpsum price of Rs.7,10,45,000.00 as inserted by MES for Sch ‘A’ part I on srl page No. 31(R)
Lumpsum price worked out by the contractor for “SITE CLEARANCE/ EARTHWORK” as listed in Sch '‘A” part II above/below the lumpsum price of Rs.9,34,685.88 as inserted by MES for Sch ‘A’ part II on srl page No.32(R)
Lumpsum price worked out by the contractor for “DEMOLITION OF B/R PORTION” as listed in Sch '‘A” part IIIA above/below the lumpsum price of Rs. 17,85,268.79 as inserted by MES for Sch ‘A’ part IIIA on srl page No.34
Lumpsum price worked out by the contractor for “DEMOLITION OF E/M PORTION” as listed in Sch '‘A” part-IIIB above/below the lumpsum price of Rs. 97,855.60 as inserted by MES for Sch ‘A’ part IIIB on srl page No.35
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY" as listed in Sch ‘A” part IV representing above/below the lumpsum price of Rs. 5,09,602.80 inserted by MES for Sch ‘A’ Part IV on srl page No.36(R)
Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION" as listed in Sch ‘A” part V representing above/below the lumpsum price of Rs. 16,66,153.15 inserted by MES for Sch ‘A’ Part V on srl page No.38
Lumpsum price worked out by the contractor for “ROAD/ PATH/ CULVERT/ HARDSTANDING” as listed in Sch ‘A” part VI representing above / below the lumpsum price of Rs. 26,34,985.34 as inserted by MES for Sch ‘A’ Part VI on srl page No.40(R)
Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL” as listed in Sch ‘A” part VII representing above / below the lumpsum price of Rs. 3,57,700.96 as inserted by MES for Sch ‘A’ Part VII on srl page No.42
Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Sch ‘A” part VIII representing above / below the lumpsum price of Rs.6,40,489.18 as inserted by MES for Sch ‘A’ Part VIII on srl page No.43
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Sch ‘A” part IX representing above / below the lumpsum price of Rs.3,19,716.82 as inserted by MES for Sch ‘A’ Part VIII on srl page No.44
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIFICATION” as listed in Sch ‘A” part X representing above / below the lumpsum price of Rs.3,77,657.00 as inserted by MES for Sch ‘A’ Part X on srl page No.45
Lumpsum price worked out by the contractor for “FIRE FIGHTING” as listed in Sch ‘A” part XI representing above / below the lumpsum price of Rs.66,059.00 as inserted by MES for Sch ‘A’ Part XI on srl page No.47(R)
Lumpsum price worked out by the contractor for “LIGHTENING PROTECTION” as listed in Sch ‘A” part XII representing above / below the lumpsum price of Rs.1,09,034.10 as inserted by MES for Sch ‘A’ Part XII on srl page No.48(R)
SCH 'A' PART XIII (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Sch 'A' Part-II.
(A) DEMOLITION (E/M)
Taking down DB/main switch of any size and making good disturbed surface of wall floor complete all as specified and directed.
Taking down carefully sub-main wiring of any description and making good to their disturbed surfaces to match the existing all as specified and as directed
Taking down Geyser of any size, capacity and any make, including hot and cold flexi pipe from the GI pipe at dismantling and removing the same and deposit to store all as specified and as directed.
Taking down MCCB/MCB of any type any capacity and any make from DB complete all as specified and directed.
Taking down energy meter single phase from blogs of any type and any make and deposit the same at MES store for reuse complete all as specified and directed.
Taking down old unsw GI wire earthing from the blogs complete all as specified and directed.
Taking down old unsw GI tubing 50mm bore from blogs including earth work complete all as specified and directed.
Taking down old unsw GI tubing 25mm bore from blogs including earth work complete all as specified and directed.
Taking down old unsw GI tubing 20mm bore from blogs including earth work complete all as specified and directed.
Taking down old unsw GI tubing 15mm bore from blogs including earth work complete all as specified and directed.
Taking down old unsw LT XLPE cable 35 sqmm 3.5 core from the trench and remove the both ends from the panel and TPN DB of bldgs including earth work complete all as specified and directed
(B) INTERNAL WATER SUPPLY
Supply & Fix 15 mm bore (concealed) angle valve of cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for CPVC pipe or for unions and fixed complete all as specified & directed.
Supply & Fix two way bib taps, 15 mm size fancy type cast copper alloy chromium plated with crutch or butterfly handle, screwed down, for CPVC pipe or for brass ferrule and fixed complete all as specified & directed.
Supply and fix stop/ angle valve 15mm bore cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for CPVC pipes or for unions & fixed complete all as specified and directed.
(C) INTERNAL ELECTRIFICATION
Materials & Labour for point wiring complete with two runs of 1.5 sqmm PVC insulated Point underlined multistranded copper conductor FRLSH cable 1100 volts grade, single core, drawn through and including concealed PVC conduit (medium Grade) of adequate size (not less than 20mm dia) with all fittings and accessories. Including one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor FRLSH Cable (green colour), single core as earth continuity conductor connected to common earth dolly for light.fan and call bell point controlled by one switch and Cutting chases for conduits and sinkings for boxes and making good to walls, floors etc.making good disturbed surfaces complete all as specified and as directed.
Materials & Labour for point wiring complete with two runs of 1.5 sqmm PVC insulated Point underlined multistranded copper conductor FRLSH cable 1100 volts grade, single core, drawn through and including concealed PVC conduit (medium Grade) of adequate size (not less than 20mm dia) with all fittings and accessories. Including one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor FRLSH Cable (green colour), single core as earth continuity conductor connected to common earth dolly for one light point controlled by Two way switch and Cutting chases for conduits and sinkings for boxes and making good to walls, floors etc.making good disturbed surfaces complete all as specified and as directed.
Materials & Labour for point wiring complete with two runs of 1.5 sqmm PVC insulated Point underlined multistranded copper conductor FRLSH cable 1100 volts grade, single core, drawn through and including concealed PVC conduit (medium Grade) of adequate size (not less than 20mm dia) with all fittings and accessories. Including one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor FRLSH Cable (green colour), single core as earth continuity conductor connected to common earth dolly for one 5Amp Switch Socket Combination on Independent board and Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc.making good disturbed surfaces complete all as specified and as directed.
Materials & Labour for point wiring complete with two runs of 2.5 sqmm PVC insulated Point unsheathed multistranded copper conductor FRLSH cable 1100 volts grade, single core, drawn through and including concealed PVC conduit (medium Grade) of adequate size (not less than 20mm dia) with all fittings and accessories. Including one run of 2.5 sqmm PVC insulated unsheathed multistranded copper conductor FRLSH Cable (green colour), single core as earth continuity conductor connected to common earth dolly for one Power point (15 Amps Switch socket Combination) on independent board, and Cutting chases for conduits and sinking’s for boxes and making good to walls, floors etc.making good disturbed surfaces complete all as specified and as directed.
Materials & Labour for point wiring complete with two runs of 2.5 sqmm PVC insulated Point unsheathed multistranded copper conductor FRLSH cable 1100 volts grade, single core, drawn through and including concealed PVC conduit (medium Grade) of adequate size (not less than 20mm dia) with all fittings and accessories. Including one run of 2.5 sqmm PVC insulated unsheathed multistranded copper conductor FRLSH Cable (green colour), single core as earth continuity conductor connected to common earth dolly for Geyser Point and Cutting chases for conduits and sinking’s for boxes and making good to walls, floors etc.making good disturbed surfaces complete all as specified and as directed.
Materials & Labour for point wiring complete with two runs of 4.0 sqmm PVC insulated Point unsheathed multistranded copper conductor FRLSH cable 1100 volts grade, single core, drawn through and including concealed PVC conduit (medium Grade) of adequate size (not less than 20mm dia) with all fittings and accessories. Including one run of 4.0 sqmm PVC insulated unsheathed multistranded copper conductor FRLSH Cable (green colour), single core as earth continuity conductor connected to common earth dolly for AC point Cutting chases for conduits and sinking’s for boxes and making good to walls, floors etc.making good disturbed surfaces complete all as specified and as directed.
Supply and fixing LED Lamp 9 watt 220 volts AC of suitable size complete all as specified and as directed.
Supply & Fix in repair LED building security light fitting 25 watt complete all as specified and directed.
Supply & Fix GI light grade pipe 1.5 m long bend to 45 degree and of diameter 25 mm suitable to building security light power cord pipe diameter with necessary clamps for fixing building security light all as specified and directed including making hole to wall if necessary (For Bldg Security Light) complete all as specified and directed.
Material and labour for sub main wiring with two single core PVC insulated unsheathed cable 6.00 Sqmm (Nominal area) with multistranded FRLSH copper conductor cable, 1100 volts grade drawn through concealed PVC Conduit with all fittings and accessories and earth continuity conductor of single core PVC insulated, unsheathed cable 6.00 Sqmm (Nominal area) with multistranded FRLSH copper conductor, 1100 volts grade and making good disturbed surfaces complete all as specified and as directed. (From 4 way TPN DB to 12 Way SPN DB) Note: (i) Two run of wiring cable, one run of earth wire and one run of PVC Conduit shall be measured as one unit.
Supply and fixing MCCB 63 Amps 4P 25 KA 415 Volt Make Indoasian Car No 830020 including MCCB Enclosure for 63 Amp MCCB Make Indoasian Car No 811985 fixed on wooden board of appropriate size for mounting of enclosure complete all as specified and as directed. Rate inclusive of Fixing of cable including lugging complete all as specified and as directed.
Suppl and fix Smart RF/Cellular Single Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 315 V, 50 Hz, 10 A-60 A conforming to IS-1644-and relevant IEC standards with intuiti Radio Frequency communication facility with self healing mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuit including Polycarbonate Meter Box of minimum suitable size for 1 Phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and directed. Meter Should support sending the following data : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand to software. Meter should have connect / disconnect functionality operable from main/billing software and prepaid features would be MDM / Billing end as per prevalent IS including taking down of existing meter and deposit to MES store yard for safe custody all as specified and as directed. Note:- Contractor has to ensure integration and maintainance of the above 06 nos of meters with the existing Advance Metering Infrastructure (AMI) of smart meters
Material and labour for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion complete all as specified and directed.
(D) EXTERNAL WATER SUPPLY
Supply and lay 100 mm dia ductile Iron pipe, S/S including specials, Class “K-7” complete all as specified and directed.
Supply and fix 80mm dia Strainer Y type conforming to IS, complete all as specified and directed.
Supply and fix 80mm dia Foot Valve conforming to IS 4038, complete all as specified and directed.
Material & Labour for cutting existing 150 mm steel tubing for alterations or additions necessarily done in position without taking down and inserting Tee of 150 x 150 x 100 mm for tapping all as specified and directed.(Tapping point shown and as directed)
Supply, install, connecting, testing and commissioning centrifugal monobloc pump set, with suitable suction / delivery head of head 36 mtr and discharge 417 LPM, CI impeller coupled with three phase induction motor 415 Volt, 2800 RPM with capacity 3.5 HP, including base frame for pump with foundation and connected with inlet as well as delivery pipe with standard arrangement as per manufacturer specification motor, pump, base complete including including accessories complete all as specified and directed.
Material & Labour for valve chamber of internal size 750x750x750mm comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm be;ow GL,100mm thick PCC 1:3:6 type B1 as in copings,3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as specified and as directed.
Material & Labour for earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering all as specified and directed and tested on completion complete all as specified and as directed.
(E) EXTERNAL ELECTRIFICATION
Material & Labour for cement concrete in foundation, filling and mass concrete type B2 1:2:4 (40mm graded aggregate), not exceeding 15 CM in depth for plinth protection for path including dismantling of old surface complete all as specified and directed.
Material & Labour for DWC pipe of 63 mm dia for cable protection complete all as specified and as directed
Supply and fixing LT Panel made out of CRCA sheet 3.15mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS-8623 tinned aluminum bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 250 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (Main Panel)
Incoming: (a) MCCB 4 Pole, 415 V,36 KA (ICS=ICU=ICW for 1 Sec), with magnetic release of capacity 160 Amps, with adjustable type overload protection, short circuit protection - 01 No Outgoing: (b) MCCB 4 Pole, 415 V,16 KA (ICS=ICU=ICW for 1 Sec), with thermal release of capacity 63 Amps, with fixed type overload protection, short circuit protection - 01 No for DG Panel (c) MCCB 4 Pole, 415 V,16 KA (ICS=ICU=ICW for 1 Sec), with thermal release of capacity 100 Amps, with fixed type overload protection, short circuit protection - 02 No for Building (d) Intelligent Panel meter to measure voltage, current, frequency, power factor etc with all connected CTs of each breakers (e) LED indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers
Supply and fixing LT Panel made out of CRCA sheet 3.15mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS-8623 tinned aluminum bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 150 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (DG Panel)
Incoming: a) MCCB 4 Pole, 415 V, 25KA (ICS=ICU=ICW for 1 Sec), with thermal release of capacity 63 Amps, with adjustable type overload protection, short circuit protection - 01 No for DG Panel Outgoing: b) MCCB 3 Pole, 415 V, 25 KA (ICS=ICU=ICW for 1 Sec), with thermal release of capacity 32 Amps, with fixed type overload protection, short circuit protection - 02 No for Lift panel c) MCB 3 Pole, TP, 415 V,16 KA C curve, 32Amps - 01 No for Fire pump d) MCB SP, 230 V,10 KA C curve, 10Amps - 01 No for street light e) Astro Timer switch -01 no for Street lights (f) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs of each breakers (g) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers.
Supply and installation LT Electric control Panel cubical type for out door use floor mounted made out of CRCA outer sheet 3 mm thick and inner sheet of 2mm thick and angle iron legs of size 50 mm x 50 mm x 5mm having front and rear open hinged doors with front openable shutters for each MCCB with spreader with fully enclosed bus bar chamber having insulated bus bar made out of aluminium strips of rating 400 amps for 3 phase/415 volts. 50 C/S 4 wire system with cable entry provision with suitable lugs gland voltmeter, ammeter, CTs and phase indicator complete duly painted with projected an raised platform of suitable size weather and waterproof with necessary locwo costs of stove enameled powder coated paint over a coat of red oxide primer complete and nuts bolt washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped with the following items: (LT Panel at Pump House of Airmen area)
Supply and fix Loop in loop out box (minimum size - 210mm x 155 mm x 92 mm) of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry with MCB 1 Amps, 10 kA, C Curve terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, complete all as specified and directed.
Material & Labour for PVC insulated copper conductor of size 1.5 sqmm 3 core for each steel light complete all as specified and directed.
All as per Item No 19.08 above but using galvanised iron strip 32x6mm as earthing lead complete all as specified & directed.
Supply and fix MCCB enclosure with MCCB 4 Pole, 415 V,35 kA , with magnetic release of capacity 200 Amps, with adjustable type overhead protection, short circuit protection with necessary fitting arrangements and with cable glands, complete all as specified & directed. (AT Gol Chakri Substation For Outgoing to Proposed Main LT Panel)
(F) FIRE FIGHTING
Supply and lay MS ERW flanged pipe 100 mm NB heavy duty duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer conforming to IS:3589 complete all as specified and directed.
Supply and fix 100 mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set complate all as specified and directed.
Supply & fix fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290 complete all as specified and directed.
Supply and fix 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 complete all as specified and directed.
Supply and fix hose box for keeping 2 Nos hose pipe of length 15 meter each, branch pipe.nozzle, coupling etc of MS sheet of Thickness 2.0 mm complete all as specified and directed.
Supply and fix branch pipe gun metal 63 mm instantaneous inlet, made threaded outlet, 20 mm bore nozzle short for hose reel conforming to IS:903 complate all as specified and directed.
Supply and fix hose box for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle , MS sheet 2 mm thickness complete all as specified and directed.
Supply and fix hose reel of 20 mm dia and 30 meter length conforming to IS 5132 complete all as specified and directed.
Supply and fix branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 complete all as specified and directed.
Supply and fix fire hydrant stand post with provn of single outlet conforming to IS 908 complete all as specified and directed.
Supply and fix gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of 02 Nos. 63 mm dia instantaneous type male coupling with built in check valves and 100 mm dia, flanged outlet complete with all accessories complete all as specified and directed.
Supply and fix Dual plates CI wafer type check valve, 100 mm bore tested to pressure of 15Kg/ Sqcm complete set complete all as specified and directed.
Supply and fix pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm complete all as specified and directed.
Cast Iron Air Valves with two air Outlets, 100 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed.
Supply and fix Addressable manual call point resettable type complete all as specified and directed.
Supply and fix Control Console of 12 zone console speaker complete all as specified and directed.
Supply and fix 6 Watt wall mount CD Speaker complete all as specified and directed.
Supply and fix 100 Watt wall mounted amplifier complete all as specified and directed.
Supply and fix Microphone set complete all as specified and directed.
Supply , laying, testing and commisioning of 2C x 1.5 sqmm cable of 1.1 /kv copper conductor power cables in metallic conduit of size 20mm over the wall/ ceiling surface. The rates quoted for laying shall include laying of cables on surface with sabdle, screw etc incl material and labour etc complete as per site requirement complete all as specified and directed.
Supply installation testing and commisioning of supply & laying of 2 core twin twisted 48/0.2 ATC multi strand over all amoured speaker cable as specified in the tender specification complete all as specified and directed.
Supply & installation of Light weight squeeze grip type CO2 type fire extinguishers of 3 kgs capacity with stand from branch new seamless dran controller of explosives approval fitted with wheel valve as per IS : 3224 with ISI mark with discharge hose and horn and supplied with initial charge as per IS :15683 with ISI mark (Sub Station & pump house) complete all as specified and directed.
Supply and fixing of dry powder ABC stored pressure squeeze grip type fire extinguishers, 9 kg cap, IS:15683:2006, filled with ABC mono ammonium phosphate base power-90 complete with discharge hose and wall mouting bracker, 2 mm mild steel EPDM rubber, pressure gauge which work effectively on all class of fires (ABC &E) with 5 years warranty incl transportation all taxes and all labour charges etc complete all as specified and directed.
Supply and fixing of 04 Nos 9 ltr round buttom sand/water buckets along with round bottom type,enamel painted white inside and red outside and letter fire in black outside & handle with mounting bracker aling with suitable MS stand to install the buckets as per the local fire standards complete all as specified and directed.
(F) LIGHTENING PROTECTION
Supply and fix air termination single pointed aluminium rod 12mm dia and 300 mm long for fixing on GI pipe medium grade 40mm dia pipe duly making suitable fixing arrangement of one end of air termination rod including dismantling old one complete all as specified and directed .
Supply and fixing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screws including provision of 30 cmx25cmx8cm sheet metal box made out of 3.15 m thick CRCA sheet with front hinged door shutter & locking arrangement and duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
(G) DG SET
(a) Engine: Diesel engine 1500 RPM of 25.5 BHP or as recommended by manufacturer, water cooled, conform to IS-10000, overload capacity of 10% for one hour in every 12 hours of continuous run, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, radiator and all standard fittings/fixtures as per standard manufacturing practices and battery charging ammeter and fuses, and also including self starter (12V) battery charging alternator complete. (b) Alternator: AC alternator, brushless, 415 V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 25 KVA at PF 0.8, 1500 RPM, insulation class 'H' enclosure SPDP (IP 23), self excited & self regulated with AVR for +1% voltage regulation, conform to IS-4722, overload capacity of 10% for one hour in every 12 hours of continuous run, coupled directly/ suitably to and to match the above engine. (c) Enclosure: Provision of an integral type, approved/certified acoustic enclosure as per CPCB-IV complaint, for the DG set to restrict the noise level to 75 dbA at one metre and ensure that temperature rise within the canopy shall not exceed 5-7 degree celsius, shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and provided with non igniting fire retardant foam as acoustic material. There shall be four hinged doors out of which one shall be with glass window and base frame shall be of ISMC.
LIFT Supply, installation, testing & commissioning of Passenger lift electrically operated with modular microprocessor based controls, complete with power driven automatic center opening with 18 SWG stainless steel (SS) moon rock finish sliding car doors and landing doors having stainless steel (SS) car enclosure suitable to carry 13 passenger lifts (884 kgs) at speed of 1.5 M/Sec to serve upto 6 floors (G+05) ,full collective operation with all standard features mentioned below and human interface device (HID) and along with (ARD) automatic rescue device confirming to NBC 2016, IS 14665 (Part-1): 2000 and IS 14665 (Part-2/Sec 1 &2) & (Part-3/Sec 1 &2) : 2000( latest edition and amendment up to date) complete all as specified and as per following technical specification.
(o)Door Opening: Center opening doors 800mm W x 2000mm H with provision of emergency key opening at all landings.SS car door finish with 2 hr. fire resistance door duly supported by valid test certificate issued by NABL accredited or Independent test laboratory.Car door lock compatible (p)Door Operation: Automatic power operation with adjustable door opening and closing timings.Variable speed high-traffic door operator (q)Monitoring: Pulse 24/7 belt integrity monitoring system and Automated rescue operation (r)Indicators: Hall position indicators for car & landing Direction and position indicator with stainless steel fixtures at all floor. (s) Over Head available/Required for 1.5 m/s: ( car height + 1900) 4100mm (t) Pit available/Required for 1 m/s :1600mm deep (u) Levelling accuracy ± 5mm independent of load in the car. (v) Guide Rails: Tounge& Groove Guide Rails (w)Brake: Braking of the lift will be done by electronically varying the voltage and the frequency of motor feeding current (variable Voltage and Variable frequency control) i.e., VVVF control(x) 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door)
The following shall also be provided in addition to above STANDARD FEATURE (i) Anti Nuisance car call protection. (ii) Automatic car return device (home landing). (iii) Independent service (for Simplex only). (iv) Overloading Device. (v) Nudging. (vi) Emergency fireman's service. (vii) Audio's car call button. (viii) Emergency Car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time protection. (xi) Emergency Alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation. (xv) Belt inspection device 7 auto fan cut off.
ADDITIONAL DEVICE Automatic rescue,infra red sensor, overload warning indicator and floor announcing system with music/arrival chime HUMAN INTERFACE DEVICE (i) Hall button with micro stroke push buttons combined with 16 signals digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push button located on side panel. (iii) Door open door closed on car operating panel. (iv) 2 way inter communication system in cabin (v) Dot matrix position indicator. (vi) Battery operated alarm well & emergency light. (vii) Fireman witch at main lobby. (viii) Manual rescue operation (ix) Call register indicator in all landings. (x) Attendant operation in car panel.
SAFETY FEATURES Motor overheatprotection , phase failure and reversal protection and features as per ISI / IS code /NBC Provision.Every lift installation shall necessarily be provided with the safety features in accordance with IS 14665(Part-4/Sec-4):2001 Note for Item no.1: (i) Contractor shall note that the defects liability period for lift shall be three years from the certified date of completion on as certified by GE: During the said defects liability period, the lift shall be kept functioned serviceable all the time and all consumable items shall also be provided by contractor for running of the lift. (ii) The lift shall be inspected and commissioned by the lift inspector and it shall be the responsibility of the contractor to get the lift inspected & commissioned without any extra cost to the department. (iii) Cost of the above provisions shall be deemed in the rates quoted by contractor. (iv) All dimensions given above are recommended dimensions . In the event of any variations mutually agreed between manufacturer and purchaser are permitted. However, variation in car inside dimensions shall be within the maximum area limits specified in 1S 14665 (Part 3/Sec 1). (v) Dimensions of pit depth and overhead may differ in practice as per individual manufacturer’s design depending upon load, speed and drive. However, the pit depth and overhead shall be such as to confirm to the requirements of bottom clearance and top clearance of IS 14665 (Part 2/Sec 1).
(vi) Contractor to obtain permission and approval prior to commencement of work and lift license from state govt authority. (vii) Item cost includes required scaffolding & structural steel brackets for erecting lift as per above specification, obtaining required all necessary permissions of Lift inspector to erect and complete the elevator work, Liaisons to operate the elevators including all necessary charges, payments for the same etc complete. (viii) Contractor to verify all above required dimension at site prior to procurement of lift . In the event of any variation the commercially available standard size lift with respect to load and category shall be submit to dept for approval. (ix) Contractor shall submit GA drawing along with other relevant details to GE for approval prior to procurement of lift.
Total amount of SCHEDULE 'A' PART XIII (MISC B/R & E/M ITEMS)
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 4.88 MB
801247tenderdocument.pdf
Tender Documents • 1.89 MB
BOQ_845850.xls
BOQ • 0.32 MB
801247DRGS.pdf
Additional Documents • 25.50 MB
801247REVDRG.pdf
Additional Documents • 27.77 MB
801247Schedule.pdf
Additional Documents • 0.28 MB
SOF399SHTNO1OF1.pdf
Additional Documents • 2.06 MB
TD154155.pdf
Additional Documents • 8.34 MB
TDSERIALWISE.rar
Additional Documents • 23.88 MB
Download all tender documents and submit your bid