| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC 00 BAJRANG CHOK MAHOBA MAHOBA UTTAR PRADESH 210427 | MAHOBA | UTTAR PRADESH | 210427 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹27.9 L+₹4.7 L (20.5%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹29.7 L+₹6.5 L (28.1%)Rejected-Finance 210 C RAM DASS KA HATA SADAR CANTT LUCKNOW UP PIN 226002 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226002 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹31.5 L+₹8.4 L (36.2%)Rejected-Finance 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L4 | Rejected-Finance Being not lowest |
Tender Value
₹28.5 L
EMD Value
₹57,160
Closing Date
29 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT, LUCKNOW
PROVN OF CERTAIN MINOR WORKS AT AF STN BKT
2021_MES_457042_1
8526/BKT/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) BKT
₹57,160
Yes
3 Sept 2021
3 Jul 2021
31 Jul 2021
3 Jul 2021
29 Jul 2021
16 Jul 2021
60 days
Amount
M&L for aluminium powder coated partition using aluminium sections fitted with 5mm thick tinted glass in upper portion from 3' height as directed and 12 mm thick prelaminated particle board both side of standard quality of approved make, any type upto 3' height from bottom using glazing clips including jointing cleat for fixing glazing clips, rubber packing anodised aluminium beading etc aluminium tower bolt, floor stoper and locking arrangement by providing latch lock of standard quality of approved make complete all as specified and directed and as per CE(AF) Allahabad Drg No CE/ALD/TD-224 Sh 1/1 dated 17 Oct 2012.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified.
Removing excavated material n exc 50m & depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specifed and directed
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete etc all as specified
M&L PCC 1:3:6 type C-2 (40mm graded stone aggreage) as in foundation filling and mass concrete etc all as specified
S&F steel work in tubular trusses including special shaped washer etc, complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St 240 complete all as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet .50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws a specified
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F mild steel work as in bands, straps, clamps, hold fasts and similar work confirming to Fe 410-0 or Fe -310-0 including bolts all as specified and directed.
M&L preparing new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M&L hardcore of gauge of broken stand n.exc 63mm, deposited spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L for 100mm thick PCC 1:4:8 type D-2 as in sub base or floor for laying of interlocking paver block as per specified and directed
M&L PCC 1:2:4 type B1 using (20mm graded stone aggregate) as in flooring 100mm thick finished even and smooth without using extra cement all as speificed and directed
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc and getting out in soft/ loose soil
Returning filling in, including spreading levelling watering and well ramming in layers not exceeding 25cm thick with soft/loose soil complete all as specified
M&L for brick work with sub class 'B' brick (using old size bricks) straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed
M&L for 15mm thcik rendering on fair faces of brick work in cement mortar 1:6 and surface finished even and smooth without using extra cement complete all as specified and directed
M&L for 15mm thcik rendering on other than fair faces of brick work in cement mortar 1:6 and surface finished even and smooth without using extra cement complete all as specified and directed
S&F Hand rails, half round or other steel section or core for wooden hand rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc : flat iron fillets (for securing wire mesh etc) includding all necessary drilling bolting or riveting etc, and similar work conforming to FE-290 Gde E-165 complete all as specified and directed
M&L for forming 12mm thick expansion joint filled with pre-formed bituminious filler & top 30mm primed & sealed with sealing compound Grade 'A' thickness of concrete slab 150mm complete all as specified and directed
M&L for forming construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and directed
Supply and fixing factory made UPVC door frame made of UPVC extruded sections having an overall dimension (extruded section profile) 42 x 50 mm (tolerance + 1mm) with wall thickness 2.00mm ( + 0.2mm), corners of the door frame jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical the frames re-inforced by galvanised MS tube size 19 x19 mm and 1 mm ( + 0.10mm ) wall thickness and 3 Nos. Stainless steel hinges fixed to the frame complete all as specified and as per directions
Providing and fixing factory made UPVC white colour casement (Openable) Door made of extruded profile with wall thickness of 2.3mm ( + 0.2mm). Window profile with hollow section with maltii chamber, frame 60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc, making arrangement for fixing of hardware EPDM gasket 1.2 + 0.2mm thick galvanised steel Frame (28 mm x 21.5 mm), sash (31mm x 27mm), T profile, frame will be fixed to the wall with 8mm x 100mm long fastners. Hardware (Casement door handle made of zinc alloyed ( white powder coated) corner striker. Secondary strikers, cylider, door tranmission gear made of mild steel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) and 5mm thick glazing with slelected qulaity glass. Note :- The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose).
S&F 5.5 mm thick one side looking glass fixed for UPVC frame complete all as specified and direccted
Taking down aluminium door frame with shutter (any size) and making good surface of wall and floor surface complete all as specified and directed
Supply and install and testing hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quailty using Non CFC and eco friendly refrigerant Gas of capacity 1.5 TR with minimum 3 star rating and EER 3.2 including outdoor unit consisting of compressor, condensor coil, candensor fan with motor and indoor unit consisting of blower, fan motor , PCB for better air flow complete all as specified and approved by EIC. Make: LG / Carrier /Hitachi /Daikin/Bluestar Note :- (i). Cutting holes in walls/window of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate . (ii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer inclusive in above rate. (iii) copper piping/drain piping is included in above rate. (iv) Iron stand for fixing out door unit in wall or rooftop is included above rate.
Supply & Fix wall mounted digital display voltage stabilizer copper winding, for automatic voltage correction single phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 230Volt and High / low voltage cut off with facility of including instant start & time delay relay of 3 minute capacity 4KVA. Make : Blue Bird, Marc Arora, V guard, Microtek
Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Mettalic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete fixed as in repairs complete all as specified and directed by Engineer-in-Charge Make Havells/MDS/Legrand
S&F Submain wiring with two single core PVC insulated FRLS multistrand copper conductor cable of size 4 Sq mm drawn into and including non metallic heavy duty rigid concealed PVC condute not less than 25 mm size ISI marked ivory colour (Pressfit or similar brand ) with all fittings / accessories and 04 Sq mm FRLS multistrand copper conductor cable as continuous earth wire complete. (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate quoted for this items.)
M&L for chemical earthing complete with copper plate electrode 900x600x5 mm burried directly in ground vertically to a depth not less than 4.70 mtr below normal ground level (with top edge of earth plate not less than 3.60 mtr below ground level) connected to copper strips 32 mm x6 mm as main earhing lead by means of brass brazing at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and eath work in any type of soil , GI pipe medium grade 50 mm bore for protection of copper strips from each electrode to earth test point of galvenised iron/steel adequetely quality of charcoal dust ,common salt and magnesium sulphate in alternate layers of 100 mm thick x 6 layers all around the plate and RCC (1;2;4) type B1 using 20 mm graded crushed stone aggregate ) cover of size 54x54x50 mm reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel flushed type handle 12 mm dia PGI funnel with wire mess ,20 mm dia GI pipe light graded for watering . Note : On testing, after completion of job, If less than 01 ohm earth resistance is not found, the earthing shall be redone at no extra cost to govt.
Supply and fix copper strips 32x6 mm duly fixed on the wall by saddels,clamps,fixing screw etc. and necessry drilling for tapping of branch complete all as specified and directed.
M & L for pit indicator made of MS angle iron of 30x30x6 mm and CRCA sheet for display of EP No & ER value in ohm on size 30cmx30cmx4mm shall be fixed with minimum 02 no of nut and bolt . The MS angle iron ensure minimum planting depth of 300 mm below ground level and 300 mm ground level including all earth work . The MS angle iron shall be painted with synthetic enamelled paint over coat of red oxide primer through out the length and therfoe plate in the portion of planting depth. Writting of letter EP & ER value in ohm and date of testing all as directd and specified by EIC. Note- Coloue coding and earth pit shall be as per Appx A of VCAS diective 17/2016.
Supply and fix copper test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including three nos 8 mm dia 25 mm long hexagonal head screw all as specified and directed.
Supply and fixing LED Light Fitting 1x16 Watt flame proof ,CMRI certified recommended for gas/vapour group of IIA &III B ,zone 1 and 2 and IP 65 Protection with die cast alluminium housing with heat resistant toughned glass with LED tube light, fixtures, driver holders ,connectors etc complete with all accesories prewired and including connecting with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
M&L for flame proof point wiring with two single core FRLS PVC insulated & PVC unsheathed stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade in and including stove enamelled steel conduit of size 20 to 25 mm with all accessories and one single core PVC insulated & PVC sheathed solid FRLS copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete incuding cutting chesses on wall/ floour/ ceiling etc. & making good the disturbed surface with 1:4 cement morter all as specified for one light / fan point controlled by one 5 Amps switch one way complete. Make of Cable :- Havells/ Plaza/Finolex/Polycab. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex
M&L switch flame proof rotory type with termination box in LM 6, 16 A,single phase 250 volts,complete all as specified and directed by Engr-in-Charge.
S & F flame proof, weather proof DB SPN 230 volt 4 way with bus bar in cast alluminium LM-6 enclosure externally spring type knob complete with M 25 cable entry to suit incoming cable and 2 nos M-20 cable entries for outgoing cable from bottom with cable gland suitable for hazardous area and confirming to IS -2147/62 Neoprene gasket degree of protection IP 65 including flame proof MCB as specified below complete all as specified and directed. (i) MCB SPN 20 Amp -01 No for incoming (ii) MCB SP 6 to 32 Amp 10 KA -02 Nos for outgoing
Supply Install and Testing of addressable fire alarm Panel which consists of display board which will have 160 Character Display with Touch key pad, Mother board which will have CORTEX 32 Bit Processor, Inbuilt RS- 485 Networking Circuit for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the Configuration tools, Two inbuilt programmable inputs, Two inbuilt NAC’s, and Three Programmable Relays, and 4 Loop Card circuits. Power Supply Board which will have SMPS fully protected board, which its operates on 120 to 220V AC ± 10% with 50/60 Hz, battery backup 24V DC with built-in charger. The panel have IP- 50 rating Optional: for BMS integration MODBUS converter, Graphical Software, Software for TCP/IP Module, provision for Auto dialler Approval UL Listed, Make: Ravel (Avni)
Supply & fix loop Card which will have 254 devices of both detectors and modules in a single line circuit, SLC supports both Class A and Class B wiring all as specified and directed Approval: UL Listed, Make: Ravel
Supply Install and Testing of multi sensor smoke Detector Voltage , 17 ~ 28V DC, Reset Voltage less than 3V, Standby Current 500 µA, Alarm Current 7 mA., Remote Output 2mA maximum open collector, Thermal Rating 59 °C (138 °F), Rate of Raise of Temp 11.1°C / min (20°F/min), Smoke Sensitivity (2.12 ± 0.61) % / ft, High 1.1% ft, Middle 1.4% ft, Low 2.3% ft, Air Velocity 0 – 4000 fpm,. Operating Temperature -10 °C to 50 °C, Humidity 0 – 95% RH, non-condensing, Approval: UL Listed, Make: Ravel
Supply & fix in repair of addressable type base,Supply voltage (min) 17V, Max Supply Voltage(Vmax) 28VDC, Quiescent Current at 24V(Ic) 30µA, Leakage Current at 24V(IL) 2 mA when isolating , 24VDC, Max Curent (through loop)(IS) 1A continuous, 3A Peak Approval: UL Listed, Make: Ravel
Supply Install and Testing of control module UI-Listed (9th Edition) , Supervised a Class ‘B’ Style ‘Y’ output circuit, Module Status by RED LED., Analogue Communication with the panel., Module Addressing by 8 way DIP switches.
Supply Install and Testing of Sounder Input Voltage 24V DC (15-30V), Current 100 mA @24V, Relative Humidity 93 ± 2 @ 32°C, Operating Temperature -10 to 50°C, Sound Level 112 db +/- 5dB @ 30cm, Tone Type Sweep Siren,
M&L for repairing of outdoor sieren hooter including servicing and replacement of all unsv parts all as specified and directed.
Supply Install Testing and commissioning of Addressable Manual Call Point – Resettable type – with back box with Binary coded address setting with Status LED for 360° visibility – IP:50 Rating – Make: Ravel
H C CONSTRUCTION
M/S PRATAP BUILDERS
Industrial Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .