Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC | L1 | Accepted-AOC Being the lowest and reasonable bidder | |
| 2 | L2₹10.4 L+₹3.5 L (50.7%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in requisite a(ii) category |
| Sl No | Description | Qty | Unit | M/S A Q ENTERPRISES L1 | M/S Noor Mohammad Shalla L2 |
|---|---|---|---|---|---|
| 1.00 | M & L for servicing to RO Plant of capacity 3000Ltrs / hour including chemical cleaning by skilled person of Indian ion company/Thermax/ Zenith/Western. | 1 | Each Job | 3,000 ₹3,000 Lowest | 7,000 ₹7,000 |
| 2.00 | M & L for servicing to RO Plant of capacity 500Ltrs / hour including chemical cleaning by skilled person of of Indian ion company/Thermax/ Zenith/Western. | 1 | Each Job | 2,000 ₹2,000 Lowest | 4,000 ₹4,000 |
| 3.00 | Supply and fix in replacement Hydranautics membranes top quality recommended byapproved company suitable for 3000 ltrs per hour RO Plant.
Make - Indian ion company/Thermax/ Zenith/Western. | 2 | Each | 45,000 ₹90,000 Lowest | 60,000 ₹1,20,000 |
| 4.00 | Supply and fix in replacement Hydranautics membranes Top quality recommended by approved company suitable for 500 ltrs per hour RO Plant.
Make - Indian ion company/Thermax/ Zenith/Western. | 2 | Each | 19,000 ₹38,000 Lowest | 20,000 ₹40,000 |
| 5.00 | Supply and fix in replacement Media complete (Carbon, Stone, Sand and Pebbles) suitable for 3000 ltrs per hour RO Plant. | 1 | Each Job | 15,000 ₹15,000 | 7,000 ₹7,000 Lowest |
| 6.00 | Supply and fix in replacement Media complete (Carbon,Stone,Sand and Pebbles) suitable for 500 ltrs per hour RO Plant. | 1 | Each Job | 15,000 ₹15,000 | 5,000 ₹5,000 Lowest |
| 7.00 | Supply and fix in replacement UV Ballast and fuse etc complete suitable for 3000 ltrs per hour RO Plant.
Make - Indian ion company/Thermax/ Zenith/Western. | 1 | Each | 500 ₹500 Lowest | 2,000 ₹2,000 |
| 8.00 | Supply and fix in replacement UV Ballast and fuse etc complete suitable for 500 ltrs per hour RO Plant.
Make -Indian ion company/Thermax/ Zenith/Western. | 1 | Each | 500 ₹500 Lowest | 1,500 ₹1,500 |
| 9.00 | Supply and fix in replacement UV Candle 20 inch long suitable for 3000 ltrs per hour RO Plant.
Make -Indian ion company/Thermax/ Zenith/Western. | 1 | Each | 500 ₹500 Lowest | 1,500 ₹1,500 |
| 10.00 | Supply and fix in replacement UV Candle 20 inch long suitable for 500 ltrs per hour RO Plant.
Make -Indian ion company/Thermax/ Zenith/Western. | 1 | Each | 500 ₹500 Lowest | 1,500 ₹1,500 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
19 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) CIF(K)
AGE(I) CIF(K) Co 56 APO
REPAIR AND MAINTENANCE OF INDUSTRIAL RO PLANTS AND SAND FILTRATION TANKS, WATER PUMPS AND MOTORS AT SHARIFABAD MIL STN UNDER AGE (I) CIF (K)
2025_MES_715951_1
AGE (I) CIF (K) - 32/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Shalateng
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
Yes
AGE(I) CIF(K)
₹20,000
Yes
23 Aug 2025
21 Jun 2025
21 Jul 2025
21 Jun 2025
19 Jul 2025
5 Jul 2025
Amount
M & L for servicing to RO Plant of capacity 3000Ltrs / hour including chemical cleaning by skilled person of Indian ion company/Thermax/ Zenith/Western.
M & L for servicing to RO Plant of capacity 500Ltrs / hour including chemical cleaning by skilled person of of Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Hydranautics membranes top quality recommended byapproved company suitable for 3000 ltrs per hour RO Plant. Make - Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Hydranautics membranes Top quality recommended by approved company suitable for 500 ltrs per hour RO Plant. Make - Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Media complete (Carbon, Stone, Sand and Pebbles) suitable for 3000 ltrs per hour RO Plant.
Supply and fix in replacement Media complete (Carbon,Stone,Sand and Pebbles) suitable for 500 ltrs per hour RO Plant.
Supply and fix in replacement UV Ballast and fuse etc complete suitable for 3000 ltrs per hour RO Plant. Make - Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement UV Ballast and fuse etc complete suitable for 500 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement UV Candle 20 inch long suitable for 3000 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement UV Candle 20 inch long suitable for 500 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Hose pipe 20 mm suitable for 3000 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Hose pipe 20 mm suitable for 500 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Rotor Meter suitable for 3000 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Rotor Meter suitable for 500 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Pressure Meter suitable for 3000 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Pressure Meter suitable for 500 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Relay for automatic panel suitable for 3000 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Relay for automatic panel suitable for 500 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western.
Dismantling and replacement of burnt existing burnt winding of water pump 5.5 HP by new copper winding wire including binding, varnising, fitting in same place and testing complete suitable for 3000 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western/ Equivalent make as mentioned in particular specification.
Dismantling and replacement of burnt existing burnt winding of water pump 2.5 HP by new copper winding wire including binding, varnising, fitting in same place and testing complete suitable for 500 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western/ Equivalent make as mentioned in particular specification.
Dismantling and replacement of burnt existing burnt winding of water pump 2 HP by new copper winding wire including binding, varnising, fitting in same place and testing complete suitable for 3000 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western/ Equivalent make as mentioned in particular specification.
Dismantling and replacement of burnt existing burnt winding of water pump 1 HP By new copper winding wire including binding, varnising, fitting in same place and testing complete suitable for 500 ltrs per hour RO Plant. Make -Indian ion company/Thermax/ Zenith/Western/ Equivalent make as mentioned in particular specification.
Taking down old unserviceable PVC Pipe 32 mm dia and supply and fix PVC pipe 32mm dia complete with all fittings as directed by Engr-in - charge
Supply and fix in replacement globe or gate valves, brass body head, screwed both ends (as per sample) for stain less steel pipe 32mm bore complete all as specified and as directed
Supply and fix gun metal, globe or gate valves, with iron wheel head, screw both ends for iron pipe and fixed 50 mm bore complete all as specified
M& L for Servicing of dosing pump 0.5 HP capacity and replacement of PVC pipe complete all as specified and as directed.
Supply only Cartridge 30" long of RO Plant 3000Ltrs / hour. Make -Indian ion company/Thermax/ Zenith/Western.
Supply only dosing Chemical anti scalant as per recommended by Indian ion company/Thermax/ Zenith/Western.
Supply and fix in replacement Media Carbon (coconut shell coal) suitable for Sand filtration plant 10000 GLNS per hour capacity.
Supply and fix in replacement Media complete (Stone,Sand and Pebbles) suitable for sand filtration plant.
Supply and fix in replacement PVC Nozzle suitable for sand filtration plant 10000 GLNS CAPACITY.
Material and labour for dismantling hot air plant/ wall mounted heater, transporting to work shop for repair/ servicing such as calibration and complete repair of hot air plant of any capacity on work bench pressure including supply of hot air as per standard procedure, any spares required for repair such as washers for speed adjustment, split cotter pin etc is deemed to be inclusive in the quoted rates.
Material and labour for dismantling to fuel injector pump, transporting to work shop for repair/ servicing such as calibration and complete repair of fuel injecton pump of hot air plant of any capacity on work bench pressure including supply of hot air as per standard procedure, any spares required for repair such as washers for speed adjustment, split cotter pin etc is deemed to be inclusive in the quoted rates.
Disconnecting existing defective electric motor of any make and capacity 20/15 HP from electric mains, isolating the necked connections, removing from foundation by unscrewing the nuts, bolts etc, decoupling from pump, opening of motor for inspection in presence of Engr-in-Charge & carry out minor repairs at site or transporting to workshop and back, re-assembling the motor after repair, refixing in position re-connecting the same as prior to removing from foundation including replacement of nuts, bolts washers of suitable size, testing and commissioning complete all as specified and directed. Note :- (a) Replacement of defecting parts shall be measured and paid separately as S&F here in after. (b) In case of major repairs not possible at site, the motor shall be shifted to contractor’s workshop, and cost of shifting to workshop and back to site is deemed to be included in the rates
All as per srl item No 34 above but capacity 2.0 to 5.0 HP
Taking out old unserviceable/burnt copper winding of motors capacity 20/15 HP (defective motor taken out in item No. 34 above) and material and labour for rewinding of elect motor of capacity 20/15 HP with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor, slots, all winding/insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engr-in-Charge all as specified and as directed.
All as per item No. 36 above but capacity 2.0 to 5.0 HP
M&L for replacement of coupling suitable for pump set 20 HP capacity centrifugal pump all as specified and directed as per site requirement.
Taking out unserviceable terminal plate with connector and outer cover of electic motor of any make and type, 20 HP capacity and supply & connecting, testing terminal plate with connector same as per existing complete all as specified and as directed Engr-in-Charge.
All as per item No. 39 above but capacity 2.0 to 5 HP.
M&L for replacement of Ball bearing of the electric motor 20/15 HP opened in item No 39 here in before complete all as directed. Make: SKF/TATA/NBC.
All as per item No.42 above but capacity 2.0 to 5 HP. Make: SKF/TATA/NBC.
Disconnecting electric connections from starter, disconnecting the water connections carefully by unscrewing the nuts, bolts and taking out from well the submersible pump set including column pipes, and submersible cable, disconnecting the pump and motor opening the pump and motor to locate the faults in presence of Engineer-in-Charge, and carry out necessary repairs as directed including transporting to workshop, re-assembling the same after repair, taking down in well, including column pipe of any dia, 10 ft long upto 20 Nos, and submersible cable, which have been taken out, re-connecting all electrical and water connections as per existing complete testing and commissioning all as specified and as directed. Note:- The replacement of parts shall be measured and paid separately.
Taking out old unserviceable/burnt winding from the submersible 3 phase motors 5 HP and M&L for rewinding the same with insulated winding wire as per existing gauge as approved by Engr-in Charge and testing after repair complete all as specified and as directed.
All as per Ser Item No 44 but motor of capacity 10 HP
All as per Ser Item No 44 but motor of capacity 15 HP
All as per Ser Item No 44 but motor of capacity 1.0 to 1.5 HP
M & L for replacement of unserviceable/ defective Gun metal bush of submersible pump of any make and capacity 5 HP pump motor after inspection by Engineer-in-Charge all as specified and as directed.
All as per Ser Item No 48 but motor of capacity 10 HP
All as per Ser Item No 48 but motor of capacity 15 HP
M & L for replacement of unserviceable/ defective PVC bush of submersible pump of any make and capacity 1.0 to 1.5 HP after inspection by Engineer-in-Charge all as specified and as directed.
M & L for replacement of unserviceable/ defective PVC impeller of submersible pump of any make and capacity 1.0 to 1.5 HP after inspection by Engineer-in-Charge all as specified and as directed.
M & L for replacement of unserviceable/ defective Gun metal impeller of submersible pump of any make and capacity 10 HP after inspection by Engineer-in-Charge all as specified and as directed.
All as per Ser Item No 53 but of capacity 15 HP
All as per Ser Item No 53 but of capacity 5 HP
Supply installation testing and commissioning of star delta starter three phase submersible pump controllers (with single phase preventer) with enclosure for 15/17.5 HP pump complete all as specified and as directed. Model No. MU-G15 FASD(WITH WIDEBAND COIL) of Make:- L&T/ Equivalent in Havells/ABB/ Schneider.
Supply installation testing and commissioning of star delta starter three phase submersible pump controllers (with single phase preventer) with enclosure for 20 HP pump complete all as specified and as directed. Model No. MU-G20 FASD(WITH WIDEBAND COIL) of Make:- L&T/ Equivalent in Havells/ABB/ Schneider.
Supply installation testing and commissioning of star delta starter three phase submersible pump controllers (with single phase preventer) with enclosure for 10 HP pump complete all as specified and as directed. Model No. MU-G10 FASD(WITH WIDEBAND COIL) of Make:- L&T/ Equivalent of Havells/ABB/ Schneider.
Supply and fixing in replacement ON LOAD changeover switch (Euroload) 4 pole open execution of 100 Amp capacity. Cat No. IHCNFOO100 of Havells or equivalant as per list of makes mentioned in particular specifictions.
Material and labour for dismantling to fuel injector pump, transporting to work shop for repair/ servicing such as calibration and complete repair of fuel injecton pump of hot air plant of 1000 Ltrs capacity on work bench pressure including supply of hot air as per standard procedure, any spares required for repair such as washers for speed adjustment, split cotter pin etc is deemed to be inclusive in the quoted rates.
Replacement of nozzle tip
Replacement of photo sensor
Replacement of photo ignition transformer
Replacement of burner gasket
Replacement of electromagnetic rod
Replacement of auto thermocut
Replacement of relay box
Note :- An amount of Rs. Rs 19,796.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S Noor Mohammad Shalla (BID ID -3356237)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .