Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC 0 PRAGATIPUR DHARMA SARMA PATH BIRUBARI KAMRUP ASSAM 781016 | KAMRUP METRO | ASSAM | 781016 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹32.2 L+₹1.3 L (4.31%)Rejected-Finance HOUSE NO 129 BASISTHA ROAD BASISTHA CHARIALI PO BASISTHA GUWAHATI 781029 ASSAM | KAMRUP METRO | ASSAM | 781029 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹32.3 L+₹1.4 L (4.62%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹33.3 L+₹2.4 L (7.91%)Rejected-Finance GOSWAMI COLONY PO UDAYAN VIHAR DISTT KAMRUP ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹34.8 L+₹3.9 L (12.7%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹66,420
Closing Date
27 Oct 2022, 6:00 pmClosed
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
SPECIAL REPAIR TO BLDG NO P-36 AND P-100 AT BASE HOSPITAL AT BASISTHA UNDER GE GUWAHATI
2022_MES_554063_1
GE/GUW/50/8258 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GUWAHATI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE GUWAHATI
₹66,420
Yes
10 Dec 2022
23 Sept 2022
29 Oct 2022
23 Sept 2022
27 Oct 2022
15 Oct 2022
23 Sept 2022 - 30 Sept 2022
Amount
Demoliation Cement concrete (unreinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all asdirected.
M&L 100mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in Sub base of floor and finished even and fair complete all as specified and as directed.
M&L 40mm thick cement concrete (1:2:4) type B-1( using 20mm graded crushed stone aggregate) as in floor and finished even and fair complete all as specified and as directed.
M&L 40mm thick cement concrete (1:2:4) type B-2( using 40mm graded crushed stone aggregate) as in Sub base of floor and finished even and fair complete all as specified and as directed.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed withover cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound, Grade B, complete all as specified and as directed.
M&L 20mm thick screed bed or bedding layer in cement mortar (1:6) as in floor finishes complete all as specified and as directed.
M&L 15mm thick screed bed or bedding layer in cement mortar (1:4) in vertical surface finishes, complete all as specified and as directed.
Dismantling of floor hearth or wall tiling incl cement mortar bedding ( but not backing) and removing debris and rubbish off the premises complete all as directed
M&L Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and as directed.
M&L coloured glazed ceramic tiles coloured in vertical surfaces 7 to 8 mm thick (square/ rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, set and jointed in neat cement slurry and pointed in white and colour cement to match shade of tiles including 10mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and as directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as directed.
S&F Gl frame work for seamless ceiling, Size of grid 605 x 605mm, comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, including 4mm thk Pre Painted Non asbestos fibre cement building boards fixed or laid/ inserted to GI framework with screws complete all as specifiedcomplete as required as per manufacturer’s instructions and as directed .
Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each. complete all as directed.
Taking down chowkat with shutter without taking off shutter from the frame exc 1.5 Sqm n.exc 4 Sqm each complete all as directed.
M&L second class hardwood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
S&F mild steel hold fasts; for securing chowkhats and similar small articles conforming to Fe-290 Gde-E-165 incuding treating hold fast with tar or coal tar black paint, sanding complete all as specified and as directed.
M&L Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint complete all as specified and as directed.
M&L providing plain cement concrete type C-1, (1:3:6), (using 20 mm graded stone aggregate), as in copings, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sidescomplete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete as required and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing as specified in SSR Part I, Section 8 complete all as specified and as directed.
S&F 300mm aluminium alloy sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy fixed complete all as specified and as directed.
S&F 200mm long Aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed.
S&F 150mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F 100mm size Butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and as directed.
M&L for preparing new wooden surfaces of any description, not otherwise describe over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two of creosote complete all as specified and as directed.
S&F Colour coated Anodised aluminium frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and directed Note:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
S&F Colour coated anodised aluminium doors shutters including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, along with standard locking arrangements, handles, tower bolts etc as required. complete all as specified and directed Note:-(i) Labour charges for fixing of glass/wire guage is inclusive in the unit rate quoted. Glass/Wire Guage/locks shall be measured and paid seperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
S&F Colour coated anodised aluminium windows/ventilators/partitions any type including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, along with standard locking arrangements, handles, tower bolts etc as required. complete all as specified and directed Note:- (i) Labour charges for fixing of glass/wire guage/aluminum grills is inclusive in the unit rate quoted. Glass/Wire Guage/aluminum grills shall be measured and paid seperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
Supply only 5.5mm thick plain sheet glass, ordinary quality fixed with Aluminum frame work exc 0.5 sqm in each pane complete all as specified and as directed.
Supply only Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminum window/ventilator shutters complete all as specified and as directed.
S&F framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed baluster; walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
S&F Rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) (confoirming to IS 12701-1996) multi layer hoisted and fixed in position 2000 ltrs capacity complete all as specified in SSR Part I, including necessary dismantling old unserviceablle tank complete all as specified and as directed
S&F in repairs 15mm bore stop valves Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair 15mm bore chromimum plated Bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs,15mm bore PVC Connection with PTMT nut of length 450 mm complete all as specified and directed
Taking down 15mm bore steel tubing and connections, including cleaning for refixing the reuseable or removal complete all as specified and directed
S&F 15mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Refixing old serviceable steel tubing in new or old position (wall, ceiling & floor) of 15mm bore with necessary GI (medium grade) fittings complete all as specified and as directed.
Taking down 20mm bore steel tubing and connections, including cleaning for refixing the reuseable or removal complete all as directed
S&F 20mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Refixing old serviceable steel tubing in new or old position (wall, ceiling & floor) of 20mm bore with necessary GI (medium grade) fittings complete all as specified and as directed.
S&F in repair Vitreous China, pedestal pattern white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including 150mm cement concrete (1:5:10) type E-2 using 40mm graded crushed stone aggregate) complete all as specified and as directed.
S&F in repair 10 litres PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flush pipe complete all as specified and directed
S&F in repairs vitreous china wash basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed.
S&F in repair , aluminum anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed
S&F in repair 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repair 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated, fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwe
S&F in repair 600x450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed
Demoliation Brickwork masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as directed
M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed
M&L PCC (1:2:4) type-B2 with using 40 mm graded crushed stone aggregate as in mass concrete for base etc complete all as specified and as directed.
M&L providing plain cement concrete type B-0, (1:2:4), (using 12.5 mm graded stone aggregate), as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as directed.
M&L for 15mm thick rendering with cement mortar (1:4) on fair faces of brick work in two layers (10mm & 5mm)seperately mixed with water proofing compound in top layer as per manufacturer's instructions and finishing the surface even and fair without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L Rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair including taking down plaster complete all as specified and as directed.
M&L Rendering 5 mm thick on concrete surfaces as in ceiling in cement mortar 1:3 for finished even and fair without using extra cement complete all as specified and as directed.
Complete removal of existing treatment on wall/ roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean,free from dust, loose paint etc by skilled labour complete all as directed.
M&L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr. of average thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI Step 3) Allow 6-8 hrs time to dry the putty surface. Note : (a.) The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. (b) Cost of scafolding upto 10m hight of building is included in this item. (c.) The contractor shall submit letter of any manufacturers of paint (as specified in tender) and their authorized applicator by whom the tenderer proposed to excecuted in the subject work before commencement of work Authorized applicator shall have authorization letter from the manufacturer (Minimum regional HQ) and authorization letter needs to be valid for the complete period of execution og the painting work (d) Masking of window/doors during spray painting using polythine film will be included. (e) Cleaning and clearing site of paint, mats etc. included.
M&L for one coat of acrylic water based exterior grade primer @0.9 ltr (undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed. Note (a.) The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. (b) Cost of scafolding upto 10m hight of building is included in this item. (c.) The contractor shall submit letter of any manufacturers of paint (as specified in tender) and their authorized applicator by whom the tenderer proposed to excecuted in the subject work before commencement of work Authorized applicator shall have authorization letter from the manufacturer (Minimum regional HQ) and authorization letter needs to be valid for the complete period of execution og the painting work.
M&L for one coat of acrylic water based interior grade primer @0.8 ltr (undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats. Note (a.) The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. (b) Cost of scafolding upto 10m hight of building is included in this item. (c.) The contractor shall submit letter of any manufacturers of paint (as specified in tender) and their authorized applicator by whom the tenderer proposed to excecuted in the subject work before commencement of work Authorized applicator shall have authorization letter from the manufacturer (Minimum regional HQ) and authorization letter needs to be valid for the complete period of execution og the painting work.
M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint with using auto roller for making the surface uniform complete all as directed. Note :- (a.) The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. (b) Cost of scafolding upto 10m hight of building is included in this item. (c.) The contractor shall submit letter of any manufacturers of paint (as specified in tender) and their authorized applicator by whom the tenderer proposed to excecuted in the subject work before commencement of work Authorized applicator shall have authorization letter from the manufacturer (Minimum regional HQ) and authorization letter needs to be valid for the complete period of execution og the painting work.
M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface with using auto roller for making the surface uniform complete all as specified and directed. Note : - (a) Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper mashking to be carried out before primer and paint application). (b.) The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. (c.) The contractor shall submit letter of any manufacturers of paint (as specified in tender) and their authorized applicator by whom the tenderer proposed to excecuted in the subject work before commencement of work Authorized applicator shall have authorization letter from the manufacturer (Minimum regional HQ) and authorization letter needs to be valid for the complete period of execution og the painting work. NOTES APPLICABLE FOR Srl Item no. 64 to 69 (i) After preperation of surfaces, Engg-In-Charge shall approve the same before applying primer and finishing coats. (ii) Building wise Stage Passing Register shall be maintained and shall be signed by Engg-In-Charge and contractor. (iii) The equipments to be used in the work shall be certified by the manufacturers with whom work proposed to be executed (iii) The contractor shall submit Gurantee Certificate for period of 5 Years from cetified date of completion approved manufacturer warranty for 05 Years
M&L prepartion of newly plastered surfaces of walls and two coats of exterior acrylic emulsion paint (1st quality) over a coat of exterior grade primer complete all as specified and directed.
M&L prepration of new plastered surfaces of wall and applying two coat of oil emulsion distemper over and including wall care putty for obtaining optimum smooth finish (1mm minimum thickness) and a coat of primer complete all as specified and directed.
M&L prepration of new plastered surfaces of ceiling and applying two coat of oil emulsion distemper over and including wall care putty for obtaining optimum smooth finish (1mm minimum thickness) and a coat of primer complete all as specified and directed.
M&L prepration of old plastered surfaces of ceiling providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
S&F mild steel curtain rod 20mm dia thickness not less than 0.75mm, fixed with curtain rod holder fixed in walls with screws and finials caps with 6 Nos of curtain ring per RM complete all as specified and directed. Note: Curtain rod holder and finials caps will be measured and paid seperately at Supply only rates)
Supply only stainless steel curtain holding braket suitable for holiding 20mm curtain rod heavy duty complete all as specified and directed.
Supply only stainless steel finial end cap suitable for curtain rod of 20mm dia as approved complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Rolled mild steel Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. conforming to Fe 410W Gde E-250, Quality B including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
M&L preparing new Steel surfaces of any description, not otherwise describe over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L preparing Old treated Steel surfaces of any description, not otherwise describe over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails complete as required and as directed.
S&F second class hardwood, 20mm thick Boarding, planned both side with butt joints fixed with nails in any situation (except flooring and skirting) complete as required and as directed.
M&L water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top (i) Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried complete (ii) Rendering 10mm thick in CM (1:4) on existing roof surface true to level after applying cement slurry @ 3Kg/Sqm.. (iii) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm. (iv) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.60 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 150gms per Sqm. Polymeric membrane shall be taken to a height as required at site/30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (iv) One coat of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions. Note : (a) Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted. (b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction.
M&L providing plain cement concrete type B0, (1:2:4), (using 12.5mm graded stone aggregate), as in roof padding for levelling course etc and the like including weathering, slightly rounded or chamfered angles & throating as finishing the surfaces fair and even including Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried complete all as specified and directed
M&L TMT bar 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Welding in repairs n. exc 2.5cm in length, Thickness of Metal to be welded Exc. 9mm but n.exc 20mm complete all as specified and directed
M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal, roughed finished surfaces, complete all as specified and as directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping),flat, roughed finished surfaces, complete all as specified and as directed.
M&L Pre polished chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick set and jointed and pointed in neat cement slurry in floor with grey cement and pigment over cement screed 15 mm thick in cement mortar 1:6 complete all as specified and as directed.
M&L for PCC (1:2:4) type B2 (using 40 mm graded stone aggregate) as in surface channels and drain complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.complete all as specified and as directed.
M&L removing, cleaning of defective concrete surfaces, applying one or more coat of primer to the reinforcement non shrink, and applying cementitious mocro concrete and finishing the surfaces even and smooth all as per manufacturers instructions complete all as specified and as directed. Note:- Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.
M&L applying one coat of epoxy primer to concrete surfaces @ 250gm/sqm all as per manufacturers instructions complete all as specified and as directed. Note:- Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down carefully unserviceable main swirch and DB's including MCB's of any description and capacity complete all as specified and as directed.
M&L for concealed point wiring with two single core 1.5 Sq.mm size FRLSH multistranded copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green FRLSH colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including 20mm(minimim) medium grade rigid PVC CONDUIT and conduit accessories i.e. joint boxes, terminal boxes for mounting or housing switches, socket outlets, fan regulators, etc. confirming to IS specifications, including provision of flush modular mounting boxes, with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for MS Sunken boxes & making good to walls, floors etc. complete all as specified & as directed for the following :- Item continued as 96 to 98
One light point/Ceiling fan/Exhaut fan/bell point controlled by one way switch 5/6 amps.
One socket out let 5/6 amps point on the same board controlled by one way switch 5/6 amps.
One socket out let 5/6 amps point on the independent board controlled by one way switch 5/6 amps.
M&L for concealed point wiring for one socket out let 15/16 amps point on the independent board with two single core 4 Sq.mm size FRLSH multistranded copper conductor PVC insulated cables and one single core 4 Sq.mm size green FRLSH colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including 20mm(minimim) medium grade rigid PVC CONDUIT and conduit accessories i.e. joint boxes, terminal boxes for mounting or housing switches, socket outlets, etc. confirming to IS specifications, including provision of flush modular mounting boxes, with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for MS Sunken boxes & making good to walls, floors etc.complete all as specified & as directed
M&L surfaces sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and PVC casing capping medium grade with accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including taking out old unserviceable submain wiring and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED
S&F LED lights fitting 1x 20Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F bracket suitable for fixing of security light fitting made out from 32 mm bore GI pipe, medium grade 1.5 metre in length, made to shape as required, fixed to pole with MS flat iron clamp of size 25x4mm duly welded, bent to shape and making holes etc complete including necessary nuts, bolts & washer etc as required and as specified and directed.
S&F Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, complete all as specified and directed.
S&F Modular shuttered Socket outlet 3/5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and directed.
S&F Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and directed.
S&F Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and directed.
S&F stepped type modular electronic fan regulator 120 watt 2 module suitable for 1200/1400 mm sweep energy saving fans,ISI marked complete all as specified and directed.
S&F ceiling rose, PVC/Polycarbonate, isolated body, three terminals, complete all as specified and directed.
S&F, Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Ttiple pole & neutral with 200 amps rated bus bar, including blanking plates as required and fixed to wall surfaces complete all as specified and as directed. .
S&F, Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 double door, Single pole & neutral with 200 amps rated bus bar, including blanking plates as required and fixed to wall surfaces complete all as specified and as directed.
S&F MCB, TPN, C Series 240 Volts, 63 Amps 50 HZ, 10KA complete all as specified and as directed.
S&F MCB, SPN, C Series 240 Volts, 32 Amps 50 HZ, 10KA complete all as specified and as directed.
S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.
M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab (1:2:4) reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.
PRITHWI BUILDERS
B & L Associates
M.G. ENTERPRISE
M/S SEWAK SINGH
JINDAL VENTURES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .