Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
26 Dec 2024, 1:00 pmClosed
SE
OFFICE OF EWC BHELUPUR VARANASI
INCREASING CAPACITY OF 33/11KV SUBSTATION JIWANATHPUR CHANDAULI ON SEMI TURN ON SEMI TURNKEY BASS.
2024_PVVNV_982781_1
16/EWC(V)/2024-25
Open Tender
Electrical Works
Lump-sum
60 days
Jeevnathpur Chandauli
Plz Refer Tender Documents
2 documents required · 2 mandatory
₹3,540
EE ESWD VARANASI
₹18,000
21 Jan 2025
12 Dec 2024
27 Dec 2024
12 Dec 2024
26 Dec 2024
12 Dec 2024
SUPPLY OF MATERIALS
24 Volt battery and battery charger with cabinet (As per RESPO Norms):- (1) 12volt lead acid battery 02 No.(2) 24 volt battery charger 01 No. & (3) Cabinet 01 No with stand
Control cable 2x2.5 MM2 (Armored Cable)
Control cable 4x2.5 MM2 (Armored Cable)
Control cable 6x2.5 MM2 (Armored Cable)
Control cable 10x2.5 MM2 (Armored Cable)
11 Kv cable jointing kit 3x400mm2 O/D
11 Kv cable jointing kit 3x400mm2 I/D
11 Kv cable jointing kit 3x185mm2 O/D
11 Kv cable jointing kit 3x185mm2 I/D
11 kV 3x185 sqmm straight through kit
Clamp and connector for 33 kV switchyard equipments
CT Junction box (for control cable wiring)
PT Junction box (for control cable wiring)
G.I pipe 6'' dia for 11 kV DP
G.I pipe 6'' dia for T/F 11 kV side cable
Top channel clamp
Dropper angle clamp
Cable holding clamp for 11 kV O/G feeder DP
Cable holding clamp for T/F 11 kV side cable
PG clamp for ACSR Panther conductor
Stone Pad 300x300x75mm for STP/PCC
Route marker patia for 11 kV cable.
11 kV Danger Board with clamps & bolts as per RESPO norms
Bolts, Nuts & Washer
ERECTION OF WORKS
33/11 kV 20 MVA Power T/F OLTC, ONAF type with neutral current / grounding transformer, cooling fan marshalling box, structures and all required accessories like conservator, radiator, vent pipe, breathers, transformer oil, WTI & OTI etc.
Control pannel for 33 Kv Single T/F
33 Kv CT 400/200/1-1A with terminal connector
CT Structure
33 Kv PT single phase 33 kv/110 volt with terminal connector
33 kV lightening arrestor
33 kV Line Isolator
33 kV Bus Isolator
Structure for L.A.
90 lbs rail pieces for T/F plinth (44.64 Kg/mtr)
11 Kv I/C VCB 1200/600/5-5 A 350 MVA, 24 Volt
11 Kv O/G VCB 200/100/5-5A 350 MVA
11 kv Bus coupler 350 MVA
11 kv disc insulator polymeric
11 kv disc fitting
ACSR Panther conductor
PCC Pole 8.5 Mtr. for Double Pole
Top channel 100x50x6-2240 mm
11 Kv MS channel for dropper angle 100x50x6-2028 mm
MS bracing angle 65x65x6-2700 mm long with 4 nos clamp
MS bracing angle 65x65x6-2700 mm long with 4 nos clamp for 11 kV transformer side cable gantry
Stay set complete (GI stay rod 20x1800 mm, stay wire 7/8 SWG 10 kg, stay clamp, bolt, nut & washer with concerte grouting)
MS earthing rod 20x2500 mm and 6 SWG earthing wire etc. (STP/PCC)
Bus-bar gantry 6.2 Mtr. long for 11 kV T/F side cable rising
24 Volt battery and battery charger with cabinet (As per RESPO Norms):- (1) 12volt lead acid battery 02 No., (2) 24 volt battery charger 01 No., & (3) Cabinet 01 No with stand.
Control cable 2x2.5 MM2 (Armored Cable)
Control cable 4x2.5 MM2 (Armored Cable)
Control cable 6x2.5 MM2 (Armored Cable)
Control cable 10x2.5 MM2 (Armored Cable)
11 kV 3x185 sqmm straight through kit
Clamp and connector for 33 kV switchyard equipments
CT Junction box (for control cable wiring)
PT Junction box (for control cable wiring)
G.I pipe 6'' dia for 11 kV DP
G.I pipe 6'' dia for T/F 11 kV side cable
Top channel clamp
Dropper angle clamp
Cable holding clamp for 11 kV O/G feeder DP
Cable holding clamp for T/F 11 kV side cable
PG clamp for ACSR Panther conductor
Stone Pad 300x300x75mm for STP/PCC
Route marker patia for 11 kV cable.
11 kV Danger Board with clamps & bolts as per RESPO norms
Bolts, Nuts & Washer
Grouting, concreting & plinthing of STP-11 Mtr./PCC 8.5 Mtr
Separate earthing of power T/F with earth pit (2 No x 60 fit for body earthing and 3 No x 60 fit for newtral delta earthing and connecting with GI Strip) (All material to be provided by contractor as per RESPO Norms)
Earthing of indoor equipments (VCB, Control Panel, etc.) with 3" dia, 3.5 Mtr long GI Pipe for chemical pipe earthing and 50x6mm GI Strip including cost of sand, charcoal, bricks, cement, etc. including cost of required material and erection and laying of pipe and GI Strip (with 1x1 Sq. feet earth pit) as per RESPO norms (All material for chemical pipe earthing to be provided by contractor)
Renovation and casting of existing transformer plinth 'TOP' with 8" thick RCC slab and existing rail piece grouting including cost of making of one side ramp by providing rail piece, cement, sand, steel rod, grit and bricks for power transformer loading/ unloading on plinth. Plinth size=4.46x4.46x0.3 Mtr as per RESPO norms. (All material like cement, sand, steel rod, grit, brick to be provided by contractor)
Digging & making of pakka trench (1.5x1 Sq. Mtr. with partation) for 11 kV 3x400 Sq.mm XLPE Cable with double configration circuit by cement, sand, bricks. Providing RCC trench cover & Cable Tray with MS angle 50"X50" per feet suitable for laying of 400 Sq.mm double circuit cable (Cement, sand, brick, rainforced steel rod, grit, MS angle 50x50x5mm etc. with all material provided by contractor) as per attached Drg./RESPO Norms
Laying & dressing of 11 Kv 3x400sqmm XLPE cable with spacer double circuit configuration with spaire cable on cable tray in pacca trench with sand filling as per RESPO Norms.
Digging & making of kaccha trench for 11 kV 3x185 Sq.mm XLPE Cable by providing sand, bricks & stone slab / Patia (for each 11 kV cable) with sand filling as per RESPO Norms (Material like sand, bricks & stone slab / Patia provided by contractor)
Laying & dressing of 11 Kv 3x185sqmm XLPE cable with double circuit configuration into kaccha trench as per RESPO Norms.
Rising of 33 kV side existing structure with material as per site condition
Hoisting of 11 kV 3x185 Sqmm Cable on errected DP
Dismantling of old & used 33/11kV, 10MVA power T/F by disconnection of radiator, conservator and it's oil removal including cost of existing Transformer safe place shifting in switchyard
Dismentling of existing CT, PT, LA, control Panel, 11 kV Switchgear panel, main Bus-bar & it's all jumpers with ACSR DOG including cost of shifting of all dismentled materials from site to concerning UPPCL store
Shifting of 11 kV incomming & outgoing cables of Transformer No. 4 to other VCB to make a space in control room as per site requirement.
Shifting of existing 11 kV Outgoing double circuit cable to new pannel and Double Pole
Installation & commissioning of new 33/11kV, 20 MVA power T/F including cost of T/F oil top-up, fitting of all accessories like conservator, radiator, vent pipe, breather, cooling fan, marshaling box for cooling fan, neutral current/grounding T/F and control wiring etc. & mounting on T/F plinth in safe position as per respo norms
Earthing of S/s for outdoor equipments with 50x6mm GI Strip including cost of material and fitting and laying of earthing strip (All material to be provided by contractor) as per RESPO Norms
Sundry Civil work (Leveling of switchyard by providing extra soil to solve water logging and making turf with pakki nali all around the T/F plinth for water drainage and making of ramp for transformer loading switchyard)
Dismantling of existing fencing and resetting after completion of transformer erection work.
Repairing of VCB Plinth including cost of sand, cement & bricks (All material like sand, cement & bricks to be provided by contractor)
Making Pakka trench in switchyard for laying of control cable including cost of sand, cement, bricks, MS angle 50x50x6 mm and suitable size cable tray (All material like sand, cement, MS angle 50x50x6 mm, cable tray & bricks to be provided by contractor)
Making of 11 Kv 3x400sqmm indoor/outdoor jointing kit
Making of 11 Kv 3x185sqmm indoor/outdoor jointing kit
Painting of S/s Structure
Cartage of all other material
M/S Grid Power Systems (BID ID -4810560)
M/S SACHIN ASSOCIATES (BID ID -4813966)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .