| 1 | L1₹25.3 LAccepted-AOC PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹28.9 L+₹2.7 L (10.4%)Rejected-Finance | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹29.7 L+₹3.6 L (13.6%)Rejected-Finance | L3 | Rejected-Finance Third lowest amount quoted | |
| 4 | L4₹30.0 L+₹3.8 L (14.5%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance Fourth lowest amount quoted | |
| 5 | L5₹36.8 L+₹10.6 L (40.6%)Rejected-Finance 1476 SARASWATI COLONY CHERITAL JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L5 | Rejected-Finance Fifth lowest amount quoted |
Tender Value
Refer Docs
EMD Value
₹77,500
Closing Date
25 Dec 2021, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2021_MES_490333_1
8376/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D a(i) (ii) b (i)
6 documents required · 6 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹77,500
Yes
7 Jan 2022
25 Nov 2021
27 Dec 2021
25 Nov 2021
25 Dec 2021
11 Dec 2021
25 Nov 2021 - 3 Dec 2021
Amount
Supply and lay pipe galvanized, “Medium grade”, including all fittings of 50 mm bore tube, laid in trenches complete all as specified and directed. Make :- ITC/Jindal/Zenith/Tata/Prakash/Surya.
Supply and lay pipe galvanized, “Medium grade”, including all fittings of 40 mm bore tube, laid in trenches complete all as specified and directed. Make :- ITC/Jindal/Zenith/Tata/Prakash/Surya.
Supply and lay pipe galvanized, “Medium grade”, including all fittings of 25 mm bore tube, laid in trenches complete all as specified and directed. Make :- ITC/Jindal/Zenith/Tata/Prakash/Surya.
Supply and lay pipe galvanized, “Medium grade”, including fittings of 20 mm bore tube, laid in trenches complete all as specified and directed. Make :- ITC/Jindal/Zenith/Tata/Prakash/Surya.
Supply and lay pipe galvanized, “Medium grade”, including fittings of 15 mm bore tube, laid in trenches complete all as specified and directed. Make :- ITC/Jindal/Zenith/Tata/Prakash/Surya.
Taking up/down GI Pipe of 40 mm to 50 mm bore and all fititng in any position as directed by Engr-in-Charge.
Taking up/down GI Pipe of 25 mm bore and all fititng in any position as directed by Engr-in-Charge.
Taking up/down GI Pipe of 15 mm to 20 mm bore and all fititng in any position as directed by Engr-in-Charge.
Supply and fix , stop valve 15 mm copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed all specified and directed by Enginer-in-Charge.
Supply and fix , stop valve 20 mm copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed all specified and directed by Engineer-in-Charge.
Supply and fix , stop valve 25 mm copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed all specified and directed by Engineer-in-Charge.
Supply and fix , stop valve 40 mm copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed all specified and directed by Engineer-in-Charge.
Supply and fix , stop valve 50 mm copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed all specified and directed by Engineer-in-Charge.
Taking down old stop valve of any size/capacity complete all as specified and directed.
S&F monoblock pump set of rating 2 HP self priming of dimension 21 x18 x 34 CM, 23-26 Kg weight mild steel , 18-26 Mtr Head, complete with all acessories single phase, 230 Volt all as specified and directed by Engineer-in-Charge.
Excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr depth and getting out complete all as specified and directed.
Returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc. 25cm all as specified and directed by Engineer-in-Charge.
Removing excavated soil n.exc 50 mtr and depositing where directed at a level n. exe 1.5mtr above the starting point all as specified and directed.
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification:- including necessary excavation and earth work in any type of soil, returning, filling and removal of surplus soil. Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1200 x 1200x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing.
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification:- including necessay excavation and earth work in any type of soil, returning, filling and removal of surplus soil. Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 900 x 900x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing.
Unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and directed. Note : maesurement shall be done after puning down of sand.
Brick covering with width equal to length of bricks as mechanical protection to cable with well burnt sub class `B` bricks laid dry and flat complete all as specified and as directed.
Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 80 mm dia Make - ITC/JINDAL/ZENITH/TATA/PRAKASH SURYA.
Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 40 mm dia Make - ITC/JINDAL/ZENITH/TATA/PRAKASH SURYA.
Point wiring conceled1100 volt grade single core PVC and unsheathed cable with multistranded copper conductor 2.5 sqmm drawn in and including eletrical grade 40 mm PVC conduit & conduit assocerries wall/ ceilling including PVC insulated unsheathed earth wire with copper conductor of & laminated wooden board (second class hard wood) or PVC board on wall for mounting of switches switch sockets fan regulator etccomplete all as specified and making good distrubed surfaces.
S &F double ploe earth enclosure with 2 pin earth plug sokcet complete with MCB SP 25 amp, flush mounting type complete all as specified and directed.
Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through in and including PVC conduit on walls/roof/floors all as directed by Engineer in Charge. Notes:- (i)Two wires of 4 sqmm and one wire of 2.5 sqmm & PVC conduit shall be measured as one unit.
Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 4.00 Sqmm to be drawn through in and including PVC conduit on walls/roof/floors all as directed by Engineer in Charge. Notes:- (i)Two wires of 6 sqmm and one wire of 4.00 sqmm & PVC conduit shall be measured as one unit.
Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 4 Single core of size 10 Sq mm, earth continuity conductor of size 6 Sq mm to be drawn through and including PVC conduit 25 mm dia medium grade conceled in walls/roof/floors all as directed by Engineer in Charge.Notes:- (i) Four wires of 10 Sq mm and two wire of 6 Sq mm and one run of PVC conduit shall be measured as one unit.
MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail ,415 Volts TPN with 4 way Double door , IP-43-IK09 protection grade complete all as specified and directed.
MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail ,230 Volts SPN with 8 way Double door , IP-43-IK09 protection grade complete all as specified and directed.
Supply & lay XLPE insulated armored and PVC sheathed heavy duty electric cable of size 4 core, 25 sqmm with aluminum conductor 1100 Volt grade laid in tranches passing through pipes/ducts including testing complete. NOTE :- Rate is inclusive of cable lugs & cable gland.
Supply & lay XLPE insulated armored and PVC sheathed heavy duty electric cable of size 3.5 core, 70 sqmm with aluminum conductor 1100 Volt grade laid in tranches passing through pipes /ducts including testing complete. NOTE :- Rate is inclusive of cable lugs & cable gland.
Supply & lay XLPE insulated armored and PVC sheathed heavy duty electric cable of size 3.5 core, 120 sqmm with aluminum conductor 1100 Volt grade laid in tranches passing through pipes /ducts including testing complete. NOTE :- Rate is inclusive of cable lugs & cable gland.
Note for Srl Item No 32, 33, 34. Necessary excavation and earth, sand cushning and cable cover work shall be measured and paid in relevant item here in before.
Supply ,install,testing and commissioning CPRI Approved of Thermoplastic Polycarbonate panel which is shock, rust, dust, impact and water proof, halogen and silicon free, UV resistance with internally embedded gasket high grade gasket made of polyurethane.The thermoplastic panel suitable size with degree of protection IP 65, type tested , system voltage 415 V, 50Hz, 4 wires, Square copper bus bar Chamber 400 Amp Capacity with temperature resistance of - 40° C to 120° C, with cable entry ,suitable size of Glands, terminals & thimbles all as specified and prewired with suitable size of PVC insulated copper conductor cable duly mounted on angle iron frame fixed on PCC blocks fixed with grouted bolts nuts and washers complete including suplly fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 250 Amp 36 KA - 01 No (incoming) (b) MCCB 4 pole 415 volts 3 phase 100 Amp 25 KA - 02 Nos (outgoing) (c) MCCB 4 pole 415 volts 3 phase 63 Amp 25 KA - 02 Nos (outgoing) (d) Digital Ampere metre - 01 No (e) Digital Volt metre flush type - 01 No (f) LED Indicator RYB - 01 Set (Set of three) Make: Hager/Legrand/ABB/C&S/Siemens of MCCB & Pannel of Make : Hensal / Rittal/Meco. Note : (i) Drawing from original equipment manufactorer (OEM) to be got approved from accepting officer before supply of panel. Drawing from any other agency/system house will not be approved. (II) Panel should be manufactured and assembled by OEM only. Fabrication/assembling from any system house will not be accepted. (iii) Inspection by company Engineer after installations at site is mandatory and rates deemed to be included it the overall quoted rates.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI strip 32x6 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth strip 32x6 mm as earth lead and 40 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core laid in trenches ass al specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core laid in trenches complete all as specified and directed.
Note for Srl Item No 38 & 39. Necessary excavation and earth, sand cushning and cable cover work shall be measured and paid in relevant item here in before.
Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 50 mm dia Make - ITC / JINDAL /ZENITH/TATA/ PRAKASH SURYA
Supply & fix PVC junction box IP 65 Protection of size 0.200 x 0.250 x 0.115 complete with 1 Nos of MCB SP 25 Amps & 4 way industrial connector including Clamp made out of MS flat 30X5 mm, connection from junction box to street light fitting with three single core PVC insulated & PVC sheathed wire 2.5 Sqmm copper. Make of Box- SPELS BERG/RITTAL/HENSEL CAT NO K8350
Supply and fix steel tubular swaged poles type 410 SP-22 (9.0 meter long) complete with CI base plate and finial including foundation and copping complete all as specified and directed. Note :- Excavation and earth work PCC 1:4:8 & 1:3:6 shall be measured and paid under relevant items here in before.
S&F in repairs sheet metal box of size 60cmx60cmx20 cm for fixing street light timer switch, frame pole mounted type fabricated out of 1.6 MM sheet steel including powder coat painting over a coat of red oxide primer including, consisting of the following complete all as specified and directed :- (a) MCCB 63 A 25 KA, 4 POLE, thermal magnetic relese, Ics=100% Icu & L&T, Cat Part No- CM97919OOH2OG /Legrand cat No-420013/schneider cat No-LV510315 - 2 nos. (b) Astronomical, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T cat no- T2 DD T7/MDS/GIC - 1 no. (c) Power contactor ML-4, 3 pole rating not less than 70 A with 230 coil make L&T/SEIMENS - 1 no. (d) Internal wiring and, clamp- 02 no, made out of 40x5mm flat & angle 40x40x5mm -0.90m long -2 nos. (e ) MCB SP 6 amps-1 No
S&F in repair LED street light lumanaries of size 120 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection complete all as specified and directed. Make: BAJAJ/HAVELLS/PHILIPS/CROMPTON.
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-3 of SSR-2009 (part-I)
M&L for Plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation of poles etc complete all as specified and directed.
M&L for Plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete for stays,foundation and platform for transformer installation complete all as specified and directed.
M&L for Plain cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate for coping of pole with and including formwork complete all as specified and directed.
Taking Down of street light Bracket including clamps of any type/any size from to pole/wall including necessary nut & bolts as directed complete all as specified and directed.
S&F GI pipe bracket made of light Grade tubing of size 40 mm bore, duly bended by hot forgoing length 1.20 mtr including two sets of clamps made of 30mm x 5mm thick Flat iron with GI bolt,nuts & washers complete all as specified and directed .
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in hard dense soil complete all as specified and directed including removal of defies/surplus soil.
Taking down of OH ACSR conductor of any size and any position including all accessories as directed by Engr-in-Charge.
M&L broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
S &F machine pressed rubber moulded coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment bedded and laid over and including 50 mm thick sand cushion compected in two layer of 25 mm each with joint filled as specified and directed.
M&L Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L Rendering 15mm thick in CM 1:6 on brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
M&L Stone kerb of machine pressed coloured precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate, block of size 30cmX30cmX15cm finished at top bullnosed shape and finished surface even and smooth using coloured pigment and jointed in CM 1:6 struck finished, applying two coats of paints in zebra pattern as directed by Engr-in-Charge.
Excavating in post holes (or similar holes) in hard/dense soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
M & L cement concrete (1:3:6) type C1 (20mm graded stone Agg.) as in embedding of angle iron post all as per specified and directed.
M & L for 100 mm thick PCC 1:4:8, type D2, using (40mm graded stone aggregate) as in sub- base floor complete all as specified and directed.
S & F steel work in tubular trusses including special shaped, using ERW pipe or induction butt welded tubes of any shape as directed conforming to IS 1161-1979 grade St -240 complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of grade Fe-410- W(Gde- E-250) also welding, fastening and fixing complete all as specified and directed.
S&F Mild steel screw bolts (machine made) 11 to 15 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
S&F Pre- painted galvanise aluminum zinc coating GI based corrugated steel sheet 0.60 mm (Profiled) thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall of mangalore pattern design, fixed with self tapping screws as specified & directed.
S & F mild steel flat iron as in wind tie for roof including securing bolts.
M&L for preparation of new or previously untreated surfaces including priming with red oxide, zinc chrome and applying two coat of synthetic enamel paint on surfaces of any description, over 10cm in width or girth,not otherwise described.
Schedule of credit amount of Rs. 88,285.00 to be deducted during AOC
Skyline Encon
M/s Ajayshwar Singh Rana
Goodluck Enterprises
RAINA SALES AND SERVICES
RAVINDRA ELECTRICAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .