| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC 183 MG ROAD JUNGLIGHAT PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN NICOBAR ISLANDS | 744103 | ₹1.6 Cr Quoted ₹1.7 Cr | L1 | Accepted-AOC Being Lowest bidder |
| 2 | L2₹1.8 Cr+₹14.9 L (8.87%)Rejected-Finance VILL SANDIPUR PO DWARNARY DISTT PURBA MEDINIPUR KOLKATA 7134403 WB | KOLKATA | PURBA MEDINIPUR | WB | 7134403 | ₹1.8 Cr+₹14.9 L (8.87%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹1.9 Cr+₹20.8 L (12.4%)Rejected-Finance | ₹1.9 Cr+₹20.8 L (12.4%) | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹1.8 Cr
EMD Value
₹2.5 L
Closing Date
5 Jul 2022, 6:00 pmClosed
CHIEF ENGINEER COAST GUARD VISAKHAPATNAM
Office of CHIEF ENGINEER COAST GUARD VISAKHAPATNAM-530007
SPECIAL REPAIRS TO TEESTA BUILDING OF INS NETAJI SUBHAS KOLKATA
2022_MES_517460_2
CE (CG) /VIZ(KOL)/TOKEN 03 OF 2022-2023
Open Tender
Civil Works
Item Rate
548 days
Kolkata
As per tender documents
8 documents required · 8 mandatory
₹1,000
Garrison Engineer (I) (CG and Navy) Kolkata
₹2.5 L
Yes
15 Jul 2022
8 Jun 2022
7 Jul 2022
8 Jun 2022
5 Jul 2022
23 Jun 2022
Amount
Schedule "A" Part – I to Schedule "A" Part – XVII: NOTE: Schedule "A" Part – I to Part – XIV EXCEPT Schedule "A" Part –IIA , Schedule "A" Part – XV, Schedule "A" Part –XVI and Schedule "A" Part –XVII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only Contractor shall insert their rates for Schedule "A" Part –IIA Schedule "A" Part – XV, Schedule "A" Part –XVI and Schedule "A" Part –XVII under Green coloured field under Column - 6 only
B/R SCHEDULE Demolition & Dismantling of building components :- Demolition of RCC work by mechnical means of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition)
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Removing mortar from and cleaning bricks, obtained from masonry of any description stacking for measurement including all extra handling and removal and disposing off rubbish complete all as specified and directed of cement mortar masonary.
Demolition of brick work manually/mechnical means including stacking of serviceable material and disposal of unserviceable material within 50m leas as per direction of engr-in-Charge
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Demolition of PCC floors and pavings n exc 15 cm thickness (below or above ground level) manually/mechnical means including stacking of serviceable material and disposal of unserviceable material within 50m less as per direction of engr-in-Charge
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M & L brick work with sub class 'B' brick straight of curved on plan exc 6m mean radius built in CM 1:6 on wall
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for Machine cut kota stone slab flooring 20-25mm thick in stair steps over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15mm thick screed bed in CM 1:6 all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement plaster and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15mm thick rendering in CM 1:4 all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for rendering 15 mm thick on brick or concrete surfaces in CM 1:4 mixed with & including WPC @ 2% by weight of cement or as per manufacturer instructions for final coat, finished surface even and smooth without using extra cement complete all as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Supply only liquid WPC
Patch Repair
Repair to sunken portion of toilets :- Dismantling of existing sunken portion upto and including old plastering (i.e upto RCC member). Cleaning of the RCC member and applying approved bonding agent as per Manufacturer Instruction, over 10mm thick plastering in CM 1:4 using liquid WPC by 2% of wt of cement over applying three layers of water proofing coats (epoxy polymer modified) as per approved. Manufacturer and fixing of PVC pipes and floor traps, sanitary appliance and filling with PCC 1:4:8 over providing 50mm thick PCC 1:11/2 :3 using wpc over applying three coats of water proofing treatment. (epoxy /polymer modified) as per standard manufacturer instruction all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Dismantling of loose concrete from RCC members to shape and size to a max depth of 100mm for receiving polymer modified member / micro concrete etc all as specified and directed. (Measurement shall be surface area of member)
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Cleaning rust from rusted steel bar by using alkaline rust remover & wire brush :- Rust Remover :- Cleaning rust from rusted reinforcement bars by using alkaline rust remover painted with brush and removing rust with flex, (after 24 hrs of application of rust remover) with the help of wire brush, sand paper or any other suitable devices and throughly washed with water with the help of pressure jet and allowing it dry complete all as specified and as directed, only area of cleaned steel bar shall be measured for payment.
(a) upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Anchoring system for rebaring by normal steel bar:- Rebaring by normal steel bars: introducing new reinforcement bars for structural connections in RCC, fixing the reinforcement in position using Hilti HY 150 chemical (Rate shall include cost of labour, epoxy cartridges, plastic nozzle etc complete including cleaning the drilled holes of loose dust by blowing air. (The cost of reinforcement shall be payble seperately) (10mm dia and 120mm depth).
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Coating Applications Anti Corrosive coating for corroded reinforcement & newly added steel bar :-Providing mixing and applying over reinforcement bars zinc antirust agent as per specificatin and direction of Engr-in-Charge (Dosage/coverage as per manufacture specification of two component epoxy based zinc rich primer steel as a protective coating to steel reinforcing bars in concrete with total zinc content in dry film>90% by volume and DFT per coat>50 microns).
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Bonding Agent :- Providing and applying bonding agent of approved brand coverage and specification of manufactures (Mixed density : 1.48 Kg/Ltr, adhesive bond strength to be >2.50MPa) Epoxy bonding agent
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Polymer modified concrete for patch repair :- M&L polymer modified concrete upto 25mm thick. Hand trowel application of PMC (Free flowing non shrink repair and could get compressive strength of 35 Mpa at 28 days including plaster
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
RCC Jacketing Application
S/F TMT bars 10 mm dia and over cut to length, bent to shape as required incl cranking bending hooking ends and binding with mild steel wire (annealed ) not less than 0.9 mm dia for column, plinth beam, liltel beam and slab, complete all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Anchorage system for rebaring by normal steel bar :- Rebaring by normal steel bars: introducing new reinforcement bars for structural connections in RCC, fixing the reinforcement in position using Hilti HY 150 chemical (Rate shall include cost of labour, epoxy cartridges, plastic nozzle etc complete including cleaning the drilled holes of loose dust by blowing air. (The cost of reinforcement shall be payble seperately) (10mm diax120mm depth for slab& Coloumn)
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Coating Applications Anti-corrosive coating for corroded reinforcement & newly added steel bar :- Providing, mixing ad applying over reinforcement bars zinc antirust agent as per specification and direction of Engr-in-Charge (Dosage/coverage as per manufacture specification of two component epoxy based zinc rich primer steel as a protective coating to steel reinforcing bars in concrete with total zinc content in dry film > 90% by volume and D.F.T per coat > 50 microns) (In column & Slab)
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 8 storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Bonding Agent :- Providing and applying bonding agent of approved brand coverage and specifications of manufactures (Mixed density : 1.48 Kg/Ltr ; Adhesive bond strength to be > 2.50 Mpa) Epoxy bonding agent (In column & slab)
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Micro- concrete cement based prepacked single component for structural repair. Micro Concrete (Pre pack) :- Providing and laying micro concrete cement based prepacked single component, chloride free, sulphate free, non-shrink, free flow, self compacting, ready to use after mixing water in specified proportion of approved quality. Rate shall be include with new plywood shuttering board cost and supporing jack system/prob to support the shuttering plate. Shuttering plate will be used in patch repair job so shuttering item will be included in this application of High strength, dual- shrinkage compensated, micro- concrete for placing in nominal thickness of 25mm to 200mm for concrete repair with compressive strength for slab/column (ASTM C 109, 7cm cube) of 25MPa at 28 days. (Slab & Coloumn)
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Grouting Applications Nozzle fixing for EPOXY Grouting :- Nozzle fixing for epoxy pressure grouting, drilling 14mm dia holes and about 75 to 100mm deep into exposed/built upto concrete which required improvement at around 300mm c/c in staggered form from all surfaces. Fixing of Neoprene nozzle 12mm dia and 40mm length into the holes with non shrink grade two component epoxy putting in order to carry out pressure grouting. Grouting the nozzle with high molecular weight low viscosity (2-5 cps) thermo-set polymer with pressure of 1-2.5 Kg/cm2.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Epoxy pressure grouting Application :- Inside voids should be treated and sealed with impremeable non shrinkage low viscous epoxy grouting materials (which are threatning the structural integrity or water tightness with mix density of 1.05 Kg/Ltr and then it should be leveled with polymer mortar concrete (PMC, Rate does not include cost of epoxy grouting material
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Waterproofing by Crystalization on all plaster surface :- Providing and applying "concrete waterproofing by crystallization" or equivalent to be supported by at least to international Test reports showing clear scanning electron Microsopic (SEM) photographs of densified and mature crystal formation to plug all the capillary tracks and pores of the concrete permanetely and permeability test as per IS2720 the concrete should not absorbed water more than 1.50 gms and not more than 1mm from the concrete surface.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Plumbing & Other items
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for 15mm thk. Screed bed or bedding layer of cement morter(1:6) for laying tiles, stone slab etc.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M & L Non skid ceramic coloured tiles 7 to 8mm th area of each tile exceeding 0.09sqm but not exc 0.16 sqm in floors etc. set and joined in neat cement slury and pointed in coloured cement to match all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M & L Glazed ceramic tiles in vertical surface 350mmx 300mmx7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Rendering 15 mm thick on brick or concrete surfaces in CM 1:4 as backing coat all as complete all as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F in repair Bib Taps cast copper alloy chromium plated with crutch or butterfly handle screwed down for high pressure, screwed for Iron Pipe or for Brass Ferrule of 15 mm dia complete all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F in repair 15mm dia stop valve/angle stop valve cast copper alloy chromium plated fancy type , high pressure with crutch screwed both ends for iron pipe
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F in repair Pillar Taps 15mm Bore Cast Copper Alloy with Capstan Heads, Chromium Plated, screw -ed down high pressure with or without lette-red ‘HOT’ or ‘COLD’ with long screwed Shanks and Fly-Nuts, screwed for Iron Pipe and fixed complete all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Taking up or down 15mm dia steel tubing and connection including cleaning for re-fixing or removal to store.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Taking up or down 20mm dia steel tubing and connection including cleaning for re-fixing or removal to store.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 8 storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Supplying and laying of 16mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including fittings like MT, FT, metal elbow, metal TEE etc. complete all as specified.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Supplying and laying of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including fittings like MT, FT, metal elbow, metal TEE etc. complete all as specified.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F 10 Ltr capacity PVC valveless syphonic action flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as required and as directed
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F 125 mm size brass chromium plated shower rose fixed to steel pipe or union complete all as specified and directed including taking out old one.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Dismalting of cast iron pipe 100/110 mm dia jointed in cement mortar and taking out.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey & above (Appx 26m to 40 m height)
S&F 110mm bore PVC (SWR) soil waste/rain water pipe and vent pipe of any length fixed to wall in any position /location
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 and above storey (Appx 26m to 40 m height)
S&F PVC (SWR) 110mm dia branch pieces (equal or un-equal) ordinary or any type or with parallel branch with oval access dose at any position.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F PVC (SWR) junction single,(single T), equal or unequal.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F Pedestal pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. complete including trap set in and including concrete ( P or S type) including connection to trap and to flushing pipe, anti syphonic pipe etc complete including provision of lime concrete bedding & making good to floor complete all as specified and directed including taking out old one.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Uptto 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F vitreous China Wash Basin, white, flat back of size 550 x 400 mm including suitable size of CI brackets, brass chromium plated waste fittings 32 mm dia with long screw shanks and fly nuts, flange and bedded in red lead cement complete all as specified and directed including taking down old one.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F 15 mm dia PVC connections, 450 mm long with PTMT nuts of suitable size at two end complete all as specified and directed including taking out old one.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S & F 32 / 40 mm dia 800 mm long PVC corrugated waste pipe fixed to walls complete all as specified and as directed including taking down old one.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F stainless steel grating doom of size 125mm of approved design complete all as specified and as directed including taking out old one.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F in repair sinks with drainage board made of stainless steel lmm thick kitch en or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm each complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F factory made solid PVC door Frame of size 50 mmx47 mm made out of 5mm thick wood grain printed PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet reinforced MS square tube supplying & fixing in opening as per specification & drawing complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F factory made solid PVC moulded door shutter 28 to 30 mm thick (stiles) with 2,4, or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specifications and drawing of page no 146 of SSR Part -II complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm each complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F 2nd class hardwood plain solid, straight chowkat and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints all as specified in and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F 35 mm thick, 2nd class hardwood glazed and skeleton shutters, open rebated and prepare to receive gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for secruing glass/gauge etc size of member of shutter as specified in SSR Part-I Section 8 Clause 8.20(a), fitted to chowkats complete all as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F 30 mm thick flush shutters solid core construction, with particle board core and ply wood face panels commercial type on both sides complete all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F Extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F MS butt hinges medium weight cold rolled of size 100 mm complete all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staple complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staple complete all as specified and directed including down old one.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F mild steel flat iron as in hold fast for door window frames or chowkat etc. cut to length or drilled hole and fixed with screw etc. complete all as directed grade of steel conforming to Fe-290 Gde-E-165
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L 25mm dia stainless steel curtain rod with catrip type with hooks/brackets fixed on walls complete all as specified and directed including taking down old one.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
Taking down cement plaster on brick or concrete wall/ceiling etc including racking out joint hacking for key, scrubbing down with water etc. complete all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L 15mm thick plastering in cement mortar on brick/concrete wall surfaces in CM (1:6) and finishing the surfaces even and smooth without using extra cement complete all as specified & directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L 15mm thick plastering in cement mortar on brick/concrete wall surfaces in CM (1:4) and finishing the surfaces even and smooth without using extra cement complete all as specified & directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing the surfaces even and smooth without using extra cement complete all as specified & directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for preparing new surfaces of internal walls and applying two coat of wall care putty including scrapping to make even and smooth surface to receive paint on internal surface of wall complete all as specified and as directed
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for two coat of oil emulsion distemper over a coat of primer on internal surface of wall, all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for preparing new surfaces of walls and applying two coat of wall care putty including scrapping to make even and smooth surface to receive paint on external surface of wall complete all as specified and as directed
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for applying one coat of anti carbonation paint on external surface of wall complete as per manufacturer instruction all as specified and as directed
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for two coat of exterior emulsion paint (weather coat) on external surface of wall over a coat of alkali resistance primer complete all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for Preparing new surfaces of ceilings and applying two Coat of white wash on ceilings, complete all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for Preparing old surfaces of ceilings and applying two coat of white wash on ceilings, complete all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for complete removal of existing treatment of old wall surfarces all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for preparation of old wall surfarces & applying two coat of wall care putty on internal surface of wall including scrapping to make surface even and smooth to receive paint complete all as all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for two coat of oil emulsion distemper over a coat of primer all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for complete removal of existing treatment of old external surfarces of wall complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for applying one coat of anti carbonation paint on external surface of wall complete as per manufacturer instruction all as specified and as directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for preparation of old wall surfarces & applying two coat of wall care putty on external surface of wall including scrapping to make surface even and smooth to receive paint complete all as all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L for two coat of exterior emulsion paint (weather coat) complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.45mm thick of an colour having tensile strength of 550 Mpa as in roof covering/clading to wall fixed with self tapping screws complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L PCC 1:2:4 type B1(20 mm graded stone aggregate) as in bed block for embedding hold fast of doors, window frames or chowkats including necessary form work complete all as all as specified directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F Framed work such as grills, gratings etc with ends of bars shoulders and/ or riveted or forged into spikes framed guard bars, ladders, framed balusters, walk ways, railing, frame work of water tanks, framed brackets of angles for sheets of chajjas and similar type of work conforming to Fe 290. Gde-E-165 complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
(a) Upto 4 storey (Appx 13.50 m height)
(b) Up to 5th to 8th storey (Appx 13 to 26m height)
(c) Upto 9 to 12 storey (Appx 26m to 37m height)
S&F in repairs 100 mm /110 mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) incl finished the good finish to disturbed concrete surface all as specified. (Up to 12 th Storey).
All as per item No. 350 here in before but 75 mm dia.
E/M SCHEDULE ( INTERNAL ELECTRIFICATION ) Taking down carefully the existing aluminium/copper point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets, ceiling rose, fan regulators, lamp holders, call bell, bell pushes any type etc by unscrewing and taken away from site complete and make good the disturbed surface as existing. Note :cost of unserviceable materials will be charged from the contractor against schedule of credit.
Taking down unserviceable submain wiring any size,complete all as specified and directed.
M&L for point wiring with 1.5 sqmm PVC insulated FRLS sheathed 1100 Volts grade copper multi stranded conductor drawn through and including rigid PVC conduit 20 mm dia concealed in walls ,roofs, etc including 1.5 sqmm PVC insulated copper conductor as earth continuity conductor and connecting it to the common earth dolly all as specified for following
All as per item no 354 but one light/ceiling fan/E fan / bell point each controller by one way switch
All as per item no 354 but one 3 pin 5 Amps socket outlet independent controlled by one switch
All as per item no 354 but one 3 pin 5 Amps socket outlet point on same board
All as per item no 354 but one light point each controlled by two way switch
All as per item no 354 here in before but with 4.0sqmm cable copper for 3 pin 15 Amps socket outlet on independent board,including 2.5 sqmm copper conductor PVC insulated sheathed continuous earth wire and connecting to common earth dolly
M & L for 1 X 20 watt LED ceiling/wall mounted lighting fixture with Lamp Lumen not less than 2100 lumen polycarbonate ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed Make : Havells/Phillips/Bajaj/Jaguar
M & L for 1 X 10 watt LED ceiling/wall mounted lighting fixture with Lamp Lumen not less than 1050 lumen polycarbonate ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed. Make : Havells/Phillips/Bajaj/Jaguar
M & L for round/square (15 watt) decorative ultra silm square & surface profile liner LED lighting fixture with Lamp polycarbonate ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed. Make : Havells/Phillips/Bajaj/Jaguar
A Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified & directed. Make : Havells/Phillips/Bajaj/Jaguar
S & F led bulb 9 Watt pin type system lumen not less than 770 Lumen.Complete all specified & directed. Make : Havells/Phillips/Bajaj/Jaguar
Taking down ceiling fan of any make/model and sweep for ovehauling/servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease, change the bearing and capacitor,painting with synthetic enamel paint double coating by spraying and refixing at site and connection complete from ceiling rose to connector with new flexible cord of suitable size, testing after completion of the work complete all as specified and as directed.
Taking down Exhust fan of any make/model and sweep for ovehauling/servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease, change the bearing and capacitor,painting with synthetic enamel paint double coating by spraying and refixing at site and connection complete from ceiling rose to connector with new flexible cord of suitable size, testing after completion of the work complete all as specified and as directed.
S & F 6 Amps one way single pole switch modular type
S & F 6 Amps two way single pole switch modular type
S & F switch socket combination 2 in one 6 amps modular type
S & F switch socket combination 6/16 Amps 5 in one modular type
S & F socket outlet 3 pin 5A modular type
S & F bell push for calling bell 5 amps modular type
S & F bell multi music type
S & F fan regulator step type electronic flush 2 modular type
S & F modular metal box 1 way
S & F modular metal box 2 way
S & F modular metal box 4 way
S & F modular metal box 6 way
S & F modular metal box 8 way
S & F modular white cover plate with frame 1 way
S & F modular white cover plate with frame 2 way
S & F modular white cover plate with frame 4 way
S & F modular white cover plate with frame 6 way
S & F modular white cover plate with frame 8 way
S & F ceiling rose 3 terminal PVC/polycarbonate isolated body type
S & F Lamp holder PVC/polycarbonate type
M & L MCB FP 'B' series 125 Amps
M & L MCB DP 'B' series 16 Amps
M & L MCB DP 'B' series 10 Amps
M & L MCB SP 'B' series 6 Amps
S & F sheet metal TPN DB 4 way double door with 200 Amps rated bus bar triple pole with neutral.
S & F sheet metal SPN DB 8 way double door with 200 Amps rated bus bar single pole with neutral.
S & F sheet metal TPN DB 8 way double door with 200 Amps rated bus bar triple pole with neutral.
M & L Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC Conduit conceiled type 2x2.5 sq. mm + 1x2.5 sq. mm for earth wire all as specified and directed.
M & L Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC Conduit conceiled type 2x4.0 sq. mm + 1x4.0 sq. mm for earth wire all as specified and directed.
M & L Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC Conduit conceiled type 2x6.0 sq. mm + 1x6.0 sq. mm for earth wire all as specified and directed.
M & L Earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate at a depth not less than 1.5 Mtr below normal ground level surrounded from all sides by 15 cms thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including galvanised earth lead wire 4.0mm dia size upto 7.5 mtr by means of bolts, nuts, checknuts and washers made out of galvanised iron and protected by medium grade 50 mm dia 5 mtr long and connected to main control panel and GI pipe 20 mm medium grade as watering pipe including funnel, wire mesh, PCC Pit made up of PCC 1:2:4 type C2 and RCC cover 40 mm thick with 8 mm bar 15 c/c including excavation and earth work all as specified in SSR Part -1, 2010.
M & L Earth continuity conductor or main earthing lead of 6mm dia GI, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing
S & F 6Module flush type with AC strter, 20 Amps MCB,plug top with indicator,complete all as specified incl connection. Make Northwest Cat No- ACPU6M-FT or equivalent
E/M SCHEDULE ( LIGHTING PROTECTION ) Taking down air termination rod,aluminium strip any size from roof top and down conductors,incl dismantling GI pipe any size and UNSV earthing pits from any location incl making good disturbed surface.
Material and labour for air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed. (Note: GI pipe and PCC block for mounting of Air Termination Rod shall be measured and paid separately under relevent item.)
Material and labour for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground incl taking down old one complete all as specified and as directed. (Note:- Aluminium strip in roof conductors shall not be directly fixed/ touching on roof surfaces.)
Material and labour for test point terminal block made of gun metal or phosphorus bronze size 75 x 75x 25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head brass screw complete all as specified and as directed.
Supply and fixing galvanised steel tubing 40 mm bore, light grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) and fixed to wall, ceiling or laid in floors for earthing strip protection complete all as specified and as directed.
Material and labour for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling, fixing or placing of air termination rods/ roof conductors and mass concrete including necessary form work complete all as specified and as directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron strip of size 32 x 6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick complete all as specified and directed. {NOTE:- Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item.
Materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground not less than 0.30m depth or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and as directed.
E/M SCHEDULE ( EXTERNAL ELECTRIFICATION ) Taking down of old LT Panne including all necessary items with lifting and carrying all as per specified and as directed
Taking down Old U/S HT/LT Cable any Size
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4.0 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2.0 core
Supply and fixing cable jointing kit for 11 KV grade cable for indoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron strip of size 32 x 6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick complete all as specified and directed. {NOTE:- Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item.
Materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground not less than 0.30m depth or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and as directed.
E/M SCHEDULE ( EXTERNAL WATER SUPPLY) ) Taking down old U/S GI Pipe 50 mm bore
Taking down old U/S GI Pipe 40 mm bore
Taking down old U/S GI Pipe 25 mm bore
Taking down Old U/S butterfly valve 50 mm bore
Taking down Old U/S gate valve 40 mm bore
Taking down Old U/S gate valve 25 mm bore
Supply and lay pipe galvanized, “Medium class”, including fittings 50 mm (2”) dia
Supply and lay pipe galvanized, “Medium class”, including fittings 40 mm (1.5”) dia
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (1”) dia
Supply and fix Valve, butterfly conforming to IS 13095,50 mm (2”) dia.
Supply and fix gun metal Valve, stop/gate, screwed,40 mm (1.5”) dia pipe
Supply and fix gun metal Valve, stop/gate, screwed,25 mm (1.0”) dia pipe
Taking down old U/S sluice valve 200/150/80 mm dia including all necessary fittings
Taking down old U/S MS ERW pipe 200mm/150 mm bore dia including all necessary fittings
Taking down hose reel any size including all necessary fittings
Taking down Butterfly valve 150mm dia including all necessary fittings
Taking down Butterfly valve 100 mm dia including all necessary fittings
taking down Non return valve 150/80 mm dia including all necessary fittings
Taking down pressure gauge any type including all necessary fittings
M & L of Sluice valve valve class PN 1.6, 200 mm bore with all necessary fittings complete all as specified and as directed.
Supply, Installation, Testing and Comissioning of mild steel ERW pipe (IS: 1239 part-I) heavy class (class 'c') including cutting, screwing, welding supporting of pipe etc. cpmplete with forged steel/butt welded fittings viz. Tees, bends, elbows, flanges, reducers, clamps/hangers etc. including cutting holes and chases in brick or RCC walls/slabs and making good the same complete include painting of pipes, fittings & steel work with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade of dia.
(a) 200 mm dia
(b) 150 mm dia
M & L MS/CI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 200mm dia size complete all as specified and as directed.
S & F Pressure gauge 4"dial 0-21 kgs rating with all necessary fittings complete all as specified and as directed
S & F Valve, butterfly conforming to each 2954.0 IS 13095 supplied and installed complete of size 100 mm (4") dia.
S & F Butterfly valve conforming to IS: 13095 complete of size 150 mm.
Supply and fix Valves, Sluice, flanged of class 1.6 PN ,150 mm (6”) dia .
Supply and fix Valves, Sluice, flanged of class 1.6 PN ,80 mm (3”) dia .
Supply and fix Non return valve, flanged type of capacity 150 mm (6”) dia .
Supply and fix Non return valve, flanged type of capacity 80 mm (3”) dia .
Material and labour for hose box indoor type made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard including taking down old one.complete all as specified and as directed.
First-aid fire hose reel wall mounting swinging type complete with drum bracket, 25 mm dia ball (stop) valve and 20 mm dia x 30 m long polymer 'light duty' high pressure hose reel tubing as per IS :884-1985.
Supply and fix branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090
Supply & fix fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290
Supply and fix 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903
Supply and fix Gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories.
M & L Rotational moulded polyethylene water storage tanks, 3 layers 2000 litrs capacity (cylindrical vertical with closed top)
Supply and lay Pipes ERW Steel including specials, nominal dia 25 mm as per IS 3589 (1981).
Supply and fix fire hydrant stand post with provn of single outlet conforming to IS 908.
Supply and fix Fire alarm control panel complying with BS EN 54 2 loop panel with 99 detectors & 99 modules & upto 200 detectors and modules per loop.
Supply and fix Fire Alarm sounders / Sirens electronic type horizontal two stage continuous normal operation for at least 50 minutes with sound level 65 db to 120 db Measured at 1.5 m with sound output variation of + 5 db 500m range
Supplying, installation, testing & commissioning of manual call point glass break type resettable type compatible with main fire alarm control board analogue type with chain hammer facility and blinking facility all as per IS 2189 and as directed at Site (Each floor) complete all as specified and as directed.
Supply , installtion, testing & commissioning of cable for fire detection and alarm system with and alarm system with 2 core annealed tinned copper conductor PVC sheathed,flexible, unarmoured 02 core cable 1.5 sqmm as per specifications in existing conduit complete as required.
S & F of Rigid metallic conduit 25 mm bore exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc
S & F of Cast Iron/ pressed steel terminal boxes 60 mm deep with 3mm thick plastic laminated sheet cover of size 100mm X 100 mm.
UNIVERSAL TRADING
CHOWDHURY CONSTRUCTION CO
Bidder Name
Hindustan Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .