| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | ₹2.0 L | L1 | Accepted-AOC Awarded for being L1 |
| Sl No | Description | Qty | Unit | M/S LIGHT PALACE L1 |
|---|---|---|---|---|
| 1.00 | Dismantling of 33 kV MOCB out door unit/ indoor pannel installed at switchyard / control room with busbar and all necessary connection engaged with MOCB / MOCB pannel. | 4 | Each | 3,928.5 ₹15,714 Lowest |
| 2.00 | Making and arrangement for installation of VCB outdoor type with its indoor panel with supply of control cable, terminal box with CST 2.5 block and necessary connection with busbar, terminal box etc as required. | 4 | Each | 8,648 ₹34,592 Lowest |
| 3.00 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works for making VCB out door base with 125 X 66 X 6 mm channel 13.70 kg/ Mtr 7.2 Mtr X 13.70 = 98.64 = 99 KG for 1. VCB indoor pannel 2 Mtr X 13.70= 27.4 kg. Total = 27.4+99 kg = 126.4 | 505.6 | Kg | 152.6 ₹77,154.56 Lowest |
| 4.00 | Testing of new 33KV Outdoor VCB, Scope of Work:- VCB 33KV testing (Contact Resistance measurement, Breaker Timing Test, Vaccum Integrity Test) by engaging test kit for final charging and trouble free operation. Secondary Relay Testing & Checking its all tripping function with associated new breaker. | 4 | No | 14,828 ₹59,312 Lowest |
| 5.00 | Testing of 33KV Outdoor PT ( 3nos = 1 set) Scope of work= PT 33KV testing (Ratio, IR Test) by engaging test kit for final charging. | 2 | Set | 5,327.6 ₹10,655.2 Lowest |
| 6.00 | Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC | 1 | Nos | 1,974.28 ₹1,974.28 Lowest |
Tender Value
₹2.3 L
EMD Value
₹3,000
Closing Date
7 Aug 2026, 5:00 pmClosed
Staff officer EnM, Bharatpur Area
Sri Dilip K Behera Mob No- 8763328081 Staff Officer EnM Bharatpur Area Office, NS Nagar Talcher Angul 759148
Installation Commissioning testing of 4 nos 33kV VCB out door type with its indoor pannel and its arrangement at North Quarry and Jambubahali Substation of Bharatpur OCP.
2026_MCL_362297_1
MCL/GM BA/EnM/eTender/2026-27/262711 dtd 21/07/2026
Open Tender
Electrical and Maintenance Works
Item Rate
20 days
Bharatpur OCP
REFER NIT
5 documents required · 5 mandatory
₹3,000
Yes
12 Sept 2026
21 Jul 2026
10 Aug 2026
22 Jul 2026
7 Aug 2026
22 Jul 2026
21 Jul 2026 - 27 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of 33 kV MOCB out door unit/ indoor pannel installed at switchyard / control room with busbar and all necessary connection engaged with MOCB / MOCB pannel. | 4 | Each | 3,928.5 | ₹15,714 |
| 2 | Making and arrangement for installation of VCB outdoor type with its indoor panel with supply of control cable, terminal box with CST 2.5 block and necessary connection with busbar, terminal box etc as required. | 4 | Each | 8,648 | ₹34,592 |
| 3 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works for making VCB out door base with 125 X 66 X 6 mm channel 13.70 kg/ Mtr 7.2 Mtr X 13.70 = 98.64 = 99 KG for 1. VCB indoor pannel 2 Mtr X 13.70= 27.4 kg. Total = 27.4+99 kg = 126.4 | 505.6 | Kg | 152.6 | ₹77,154.56 |
| 4 | Testing of new 33KV Outdoor VCB, Scope of Work:- VCB 33KV testing (Contact Resistance measurement, Breaker Timing Test, Vaccum Integrity Test) by engaging test kit for final charging and trouble free operation. Secondary Relay Testing & Checking its all tripping function with associated new breaker. | 4 | No | 14,828 | ₹59,312 |
| 5 | Testing of 33KV Outdoor PT ( 3nos = 1 set) Scope of work= PT 33KV testing (Ratio, IR Test) by engaging test kit for final charging. | 2 | Set | 5,327.6 | ₹10,655.2 |
| 6 | Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC | 1 | Nos | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 1.28 MB
Tendernotice_2.pdf
PDF • 1.54 MB
BOQ_375209.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .