| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC | L1 | Accepted-AOC Being l1 | |
| 2 | L2₹36.6 L+₹78,553 (2.19%)Rejected-Finance MCB Z 2 13519 ST NO 4 GREEN AVENUE BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Rejected |
Tender Value
₹42.9 L
EMD Value
₹85,800
Closing Date
13 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faridkot
GE Faridkot Military Station
Provn of certain sanctioned works at Faridkot Mil Stn
2023_MES_618747_1
GE FRD-64/2023-24
Open Tender
Civil Works
Item Rate
240 days
GE Faridkot
Class D Category a i
9 documents required · 9 mandatory
₹500
GE Faridkot
₹85,800
Yes
15 Nov 2023
14 Sept 2023
16 Oct 2023
14 Sept 2023
13 Oct 2023
29 Sept 2023
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5m deep and 1.5m wide, for foundation etc or manholes,piers,shafts etc not exceeding 10 Sqm on plan and getting out complete all as specified and directed.
Returning, filling in,including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed .
Removal of surplus soil to a distance not exceeding. 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed .
M&L for cement concrete 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed .
M&L PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in coping,bed blocks and similar works including slightly rounded or chamfered angles including necessary formwork complete all as specified and directed.
M&L for providing Reinforced Cement Concrete M-25 (Design Mix) (using 20 mm graded crushed stone aggregates) as in foundation including rafts, footings, foundation beams, plinth beams, bases of columns etc complete all as specified and directed.
M&L for providing Reinforced Cement Concrete M-25 (Design Mix) (using 20 mm graded crushed stone aggregates) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for providing Reinforced cement concrete M-25 (design mix), (using 20mm graded crushed stone aggregates) as in lintels over 1.5 mtr clear span, siesmic band,beams,cantilevers and similar works complete all as specified and directed .
M&L for providing Reinforced cement concrete M-25 (design mix), (using 20mm graded crushed stone aggregates) as in slab supported on walls, beams, columns,landings,balconies, canopies,deck slabs and in shelves and other similar works complete all as specified and directed and directed .
M&L for brick work with fly ash bricks, using old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed .
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter, for rough finished surfaces of concrete all as specified and directed.
M&L for use and waste of form work to soffits of suspended slab such as roof slabs, not exceeding 200mm thick, horizontal or sloping complete all as specified and directed .
M&L for use and waste of form work to sides of pillars,struts,piers and columns square/rectangular for fair finished surfaces complete all as specified and directed.
M&L for use and waste of form work to sides and soffits of floor or roof beams, beam hunching, girders, lintels, cantlievers, shelves including supports, etc for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape as required, including cranking, bending and binding with & including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed .
M&L for Mild steel TMT bars 5 mm dia and over upto & including 10mm dia, as in stirrups, spacers and binders,cut to length bent to shape required including cranking, binding spirally for hooping for columns, hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed .
M&L for sand filling under floor,foundation with washed and screened dry fine river sand including watering, well ramming and consolidation complete all as specified and directed .
M&L for hard core of gauge not exceeding 63mm using broken stone or boulders, deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed .
M&L for 75 mm thick cement concrete 1:3:6 type C-2( using 40mm graded crushed stone aggregates) as in plinth protection/path, finishing surfaces even and fair complete all as specified and directed .
M&L for forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound, grade A complete all as specified and directed .
M&L for Granite (of any type) machine cut, 20mm thick, bedded and jointed with grey cement slurry over and including screed of 20mm thick in cement mortar 1:6 and pointed with white cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror polishing complete all as specified and directed .
M&L for marble work 18mm thick of any shade (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointed in white cement (1:2) using marble dust with admixture of pigment to match the shade of the marble over and including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
S&F Machine cut kota stone slab in flooring ,20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing,cutting and mirror polishing over and including 20 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed.
S&F Machine cut kota stone slab 18-20mm thick as in skirting,steps,dado,& pillars, set and jointed in cement slurry over & including 15 mm thick rendering in cement mortar1:4 and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type polishing complete all as specified and directed .
S&F Glazed ceramic coloured tiles 450mmx300mmx7mm/350mmx250mmx7mm / 450mmx350mm x7mm thick (colour and shade as approved) as in vertical surfaces such as skirting/dados etc, set and jointed in neat cement slurry & pointed in white cement with pigment to match the colour of tiles over & including 15mm thick rendering in cement mortar 1:4 complete all as specified and directed .
M&L for rendering 15 mm thick in cement mortar 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed .
M&L for rendering 15 mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed .
M&L for rendering 5 mm thick in cement mortar 1:3 on ceiling, surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 Cement : 4 Coarse Sand) the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square meter, top layer 15mm cement Plaster 1:1/2:2 (1 Cement : 1/2 Coarse sand : 2 Stone chipping 10mm nominal size) in panels with grooves all round as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed. Note : Payment for providing grooves shall be made separately)
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
M&L for preparation of newly plastered surfaces of ceiling by applying one coat of wall care putty manually and sanding the surfaces with mechanical equipment and applying two coats of dust proof interior acrylic emulsion paint (premium quality) with mechanical method over and including one coat of appropriate primer with mechanical method complete all as specified and directed.
M&L for applying evenly a tack coat of in industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and directed .
Supply and fix APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150gms/sqm) laid over primed surface by using forced application complete all as specified and directed. Note : (i) The treatment shall be carried out as per the manufacturers instructions and as directed by Engineer in Charge. (ii) The plan area of floor shall be considered for payment (iii) Complete treatment to be carried out by authorised applicator of waterproofing manufacturer.
M&L for applying two coats of aluminium paint over APP membrane complete all as specified and directed .
S&F anodised aluminium frame for doors, window, ventilators with one or more rebates including joining cleat for fixing etc complete with powder coating on aluminium (minium thickness of powder coating 50 micron) as per the specification. The top & bottom horizontal members and vertical members adjacent to walls shall be fixed with floor, ceiling, walls and cills where required and fixing with the help of rawl plug and screw or with fixing clip or with expansion hold plate fasteners complete all as specified and directed.
S&F powder coated (thickness of powder coating not less than 50 micron) coloured aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, powder coated aluminium snap beading, screws, handles 2 Nos in each door, hinges, complete all as specified and directed .
S&F powder coated( thickness of powder coating not less than 50 micron) coloured aluminium window and ventilator shutters,side hung type without sash bars, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, powder coated aluminium snap beading, screws, hinges B-21,100mm long(02 Nos),peg stay 150mm long (01No) ,handle 01 No complete all as specified and directed .
M&L for 4.8 mm thick, plain sheet glass ordinary quality and glazing with oil putty or with wooden beads (supplied alongwith shutters) in squares exc 0.5 Sqm in each pane complete all as specified and directed.
M&L 4 mm thick, plain sheet glass ordinary quality and glazing with oil putty or with wooden beads (supplied alongwith shutters) in squares n.exc 0.5 Sqm in each pane complete all as specified and directed.
S&F door closer hydraulically regulated, Aluminium (extruded section body), designation No 1, universal type, suitable for door shutter upto 700mm in width and weight not more than 35 kg complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made out of mild steel heavy duty & fixed complete all as specified and directed.
S&F 3mm thick Rubber door seal of width not less than 50mm, fixed with stainless steel screws complete all as specified and directed .
S&F stainless steel solid body peg set of six,fancy type ,fixed in position with steel screws complete all as specified and directed.
S&F aluminium anodised barrel tower bolts,100 mm long of extruded section, fixed with screws complete all as specified and directed .
S&F Aluminium anodised, cast type, handle 150 mm size complete all as specified and directed.
S&F brass mortice lock, vertical type, size 75 mm, 4 levers complete all as specified and directed.
M&L for aluminium anodised grill of standard size sections (design & pattern as approved by Engr-in-charge) , fixed to aluminium frame work complete all as specified and directed.
S&F 7-8mm thick PVC laminated gypsum board as in ceiling fixed with screws as per manufacturer's instructions, including anodised aluminium snap grid frame work for false ceiling of grid 605x605mm, hangers 6mm dia (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size & length 60mm and expansion hold fasterners 12.5mm dia,40mm long complete all as specified and directed.
S&F Solid PVC wall lining consisting of 5mm thick wood grain printed PVC sheet having beading/border on top and on joints inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawings all as specified and directed .
S&F 5mm thick PVC Sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing all as specified and directed .
M&L for 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base,mass filling complete all as specified and directed .
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footpath, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed .
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed .
M&L for brick work with sub class 'B' bricks using old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed .
S&F PVC door frame of size 50x47mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube, edges shall be printed to match printed sheet in opening complete all as specified & directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width & stick inside with solvent cement for stile and plain colour PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the style and rail with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site complete all as specified and directed.
S&F Aluminium anodised, cast type, handle 125 mm size complete all as specified and directed.
S&F Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying finishes complete all as specified and directed .
M&L for rendering 15 mm thick in cement mortar 1:4 mixed with WPC on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed . Note:- WPC will be measured and paid separately as supply only
Supply only integral water proofing compound complete all as specified and directed .
M&L for preparation of newly plastered or unplastered surfaces of wall and applying three coats of white wash complete all as specified and directed .
M&L for preparation of newly plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed .
S&F Cast iron floor trap, long neck, 75 mm dia with stainless steel grating including jointing to waste pipe, fixed in cement concrete type B1, 1:2:4 complete all as specified and directed .
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 Ltr capacity,trippled layered, hoisted and fixed in position including PTMT float valves, high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed in position including all necessary fittings complete all as specified and directed.
S&F vitreous china Wash hand basin, white, flat back of size 630x450mm including cutting for and pinning in ends of brackets or erecting stand including Brass chromium plated waste coupling 32mm bore, Waste pipe PVC 32mm bore, pillar taps,fancy type,chromium plated ,cast copper alloy, with capstan head, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of 15mm bore complete all as specified and directed.
S&F pillar taps,fancy type,chromium plated ,cast copper alloy, with capstan head, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of 15mm bore complete all as specified and directed.
M&L for Steel water tubing of 15 mm bore, medium grade, galvanised with all fittings, laid in trenches/ fixed to wall etc complete all as specified and directed .
M&L for Steel water tubing of 20 mm bore, medium grade, galvanised with all fittings, laid in trenches/ fixed to wall etc complete all as specified and directed .
S&F 15mm bore bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down of iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F Stop valve/angle valve, cast copper alloy,screwed down for high pressure with crutch or butter fly handle, screwed both ends for iron pipe of 15mm bore complete all as specified and directed .
S&F PVC connection 15mm dia 45 cm long with brass nut and washer both side complete all as specified and directed.
S&F Grating doom, 100 mm dia of PTMT (minimum weight 25gms) complete all as specified and directed.
S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed .
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches/in floors/fixed to walls including fixing clamps with nut and bolts complete all as specified and directed .
S&F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches/in floors/fixed to walls including fixing clamps with nut and bolts complete all as specified and directed .
S&F PVC (SWR) bends any radius ,110mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single T) equal or unequal,110mm bore complete all as specified and directed.
S&F Chromium plated soap dish of size 160x160x90mm, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F Vitreous china half stall Urinal of size 635x395x420mm, white including providing and fixing plugs, bedding urinal against wall in CM 1:2 securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe and half turn valve 15mm bore connection to drain etc. complete all as specified and directed.
S&F stainless steel urinal push flush valve complete all as specified and directed .
S&F vitreous china wash down water closet pan (pedestel pattern) white in colour including connection pipe to union of flushing cistern, inlet and overflow pipes,connecting only to flushing cistern, anti-syphonage pipe with PVC flush pipe of 32mm dia including plastic seat with cover,white in colour with mild steel chromoum plated hinging and 'P' or 'S' trap device complete all as specified and directed.
S&F brass chromium plated overhead shower rose 125 mm of size with arm and with or without swivel joints to steel pipe or union of size 15mm bore complete all as specified and directed.
S&F Brass Chromium plated basin/sink mixer for mixing hot & cold water screwed down for 15mm bore iron pipe complete all as specified and directed.
S&F PVC waste pipe, 32 to 40 mm for WHB/Sink /urinal up to floor trap and fixed complete all as specified and directed.
S&F 10 litres PVC,valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt of length 150mm with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extuded sections or cast aluminium alloy and fixed complete all as specified and directed .
S&F aluminium anodised,skelton tower bolt of length 450mm with plate,staples,and bolt of extruded section complete all as specified and directed.
S&F Reinforced concrete pipes of size 150mm (internal dia),class NP-2 (ISI marked) laid, jointed and tested complete with collar complete all as specified and directed .
M&L for Concrete bed to drain pipes using PCC 1:4:8 type D-2 40mm graded stone aggregate including packing under haunching against the sides of pipe after laid & tested for 150mm bore of pipes complete all as specified and direced.
M&L for Pre cast cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in manhole cover slab, rounded or chamfered on edge included neccessary formwork, set in cement mortar 1:4 complete all as specified and directed .
S&F Tubular towel rail, brass chromium plated, 20mm dia, D type, 60cm long between flanges complete all as specified and directed .
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2) round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required (Internal Dia of pipe in 150mm) complete all as specified and directed.
Excavating in post holes each not exc 0.50 cum, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layer not exc 25cm and removing surplus soil to a distance not exc 50m and making good surface all as specified`and directed .
M&L for 100mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base,mass filling complete all as specified and directed .
M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour,design & pattern as in footpath, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed .
S&F angle iron posts and struts in fencing, including cutting tops to shape as directed, drilling holes, notching for wire etc,including all necessary drilling, bolting ,riveting or welding etc and similar works conforming to Fe-290 Gde E-165 quality complete all as specified and directed.
M&L for cement concrete 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed .
M&L for preparation of new or previously untreated steel,concrete surface of any description over 10cm width or girth, not otherwise described and applying two coats of black bituminous paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F galvanised,2strand,steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire,staples or steel pins etc. complete all as specified and directed .
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid concealed conduit of suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 2.8mm thick plastic laminate Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated, stranded (Green colour) connected to common earth point dolly for for one light point/fan point/call bell point, 230 volts controlled by one switch complete all as specified and directed .
All as per Ser item No 103 here-in-before but for switch socket combination 5 Amp 5 Pin socket outlet 230 volts on same board with other switches complete all as specified and directed .
All as per Ser item No 103 here-in-before but for switch socket combination 5 Amp 5 Pin socket outlet 230 volts on independent board complete all as specified and directed .
All as per Srl item No. 103 here-in-before for Switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5Sqmm FRLS PVC unsheathed copper conductor and FRLS cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed .
S&F PVC Lamp holder with back plate suitable for batten fittings complete all as specified and directed .
S&F LED bulb 1 x 10 watt Lamp having luminous efficiency warranty 2 years complete all as specified and directed .
S&F complete set of tube light fitting, 1x20 watt LED (4 feet long), 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube, internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Havells Cat Part No LUMILINEBS20WLED865SPCWH/Bajaj Cat Part no 830379 20WCDL/Crompton Cat Part No LDLL20-CDL
S&F complete set of tube light fitting, 1x10 watt LED (2 feet long) 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube, internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed . Havells Cat Part No LHEXACP7IN1W010/Bajaj Cat Part no BCLSB 10W/Crompton Cat Part No LDLL10-CDL
S&F ceiling rose, three terminals, PVC polycarbonate, isolated body with bakalite 20mm back plate complete all as specified and directed .
S&F switch piano, flush type, single pole, one way, 5 /6 Amp,230 V,AC supply complete all as specified and directed .
S&F socket outlet, two in one, 5 Pin 5 Amps, 230 Volt, AC supply, complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 15/16 Amps, 230 volts AC supply complete all as specified and directed.
S&F socket outlet ,2 in 1, 5/6 pin, 15/16 Amps, 230 volts ,AC supply complete all as specified & directed.
S&F factory made epoxy polyester powder coated distribution board TP&N ,4 ways (VTPN DB), double door,(concealed flush to wall) (IP-42 protection) fabricated from minimum 1.2 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 250 Amps bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with space for provision for 4 pole MCCB as incommer and outgoing MCBs as required at site and conforming to IS: 8623 along with cable end box including making good disturbed surface complete all as specified and directed. NOTE: (a) MCCBs and MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of BoQ.
S&F Sheet metal enclosure for DBs,SPN, double door, 230 Volts,8 ways with 200 amps rated bus bar complete all as specified and directed .
S&F MCCB 4 Pole,adjustable type ,415 V, 63 Amps with breaking capacity 16 KA complete all as specified and directed.
S&F MCB SP 5 to 32 Amp, 230 volts, B Curve with breaking capacity 10 KA complete all as specified and directed .
S&F MCB, SPN, 32 amps, 230V, C Series with breaking capacity 10 KA complete all as specified and directed.
Supply & fixing Energy efficient Ceiling fan complete with blades, down rods, electronic type regulator & accessories, 230 V,1400mm sweep, minimum air delivery 245 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) including writing of MES number (Black, Roman, Italic or Indian) n. exc 30cm height complete all as specified and directed.
S&F energy efficient LED Security light fitting of 25W, pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/ roadway luminaire, with driver including electric connection, complete fitting with all accessories on and including bracket of 32mm dia,light grade ,GI pipe ,1.20 m and connecting with twin core twisted flexible copper conductor cable 1.5 Sqmm and with following specifications complete all as specified and directed :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max15%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with TMT bar 8mm dia both ways @100c/c. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
S&F in repair GI pipe, light grade, 40mm bore, for cable protection, fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid separately.
Supply, install, testing and commissioining of hi wall split units indoor/outdoor Air conditioner (3 STAR RATING), heating and cooling type complete with cordless remote control unit and with in built air ioniser and plazma filter for better indoor air quality. Electric driven single phase 230 volts, AC, 50HZ, R-32 refrigerent and Digital Inverter twin rotary of capacity 2 Ton, including copper piping of adeuate size and required length as directed duly insulated with suitable insulating material e.g. glass wool, plywood, moulded thermocoal etc complete with steel bracket with necessary fittings for condensing unit and copper cable of suitable size for making electric connections complete all as specified and directed. Note:-Bidder has to furnish a replacement warranty of 05 years for AC from the date of completion of CA
Supply, install, testing and commissioining of Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 170 volts to 270 volts with output voltage stabilized 230 Volts with accuracy of ± 2.5% of capacity 5 KVA with mounting bracket complete with time delay relay complete all as specified and directed.
Supply, install, testing and commissioining of hi wall split units indoor/outdoor Air conditioner (3 STAR RATING), heating and cooling type complete with cordless remote control unit and with in built air ioniser and plazma filter for better indoor air quality. Electric driven single phase 230 volts, AC, 50HZ, R-32 refrigerent and Digital Inverter twin rotary of capacity 1.5 Ton, including copper piping of adeuate size and required length as directed duly insulated with suitable insulating material e.g. glass wool, plywood, moulded thermocoal etc complete with steel bracket with necessary fittings for condensing unit and copper cable of suitable size for making electric connections complete all as specified and directed. Note:-Bidder has to furnish a replacement warranty of 05 years for AC from the date of completion of CA
Supply, install, testing and commissioining of Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 170 volts to 270 volts with output voltage stabilized 230 Volts with accuracy of ± 2.5% of capacity 2 KVA with mounting bracket complete with time delay relay complete all as specified and directed.
S&F Sub main wiring with two runs of single core PVC FRLS sheathed, insulated, copper cable of 4 Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 4 Sqmm for continous earth wire drawn into and including PVC concealed conduit of suitable size complete all as specified and directed . Note :- Two runs of 4 Sqmm copper cable and one run of 4 sqmm copper wire earth continuty conductor & conduit with accessories shall be measured as one length)
S&F in replacement Sheet Metal single pole and neutral Enclosures with a two pin and earth plug and socket with MCB SP 20 Amps suitable for working on 240 volts AC complete all as specified & directed.
S&F Socket Residual Current Device (SRCD) with steel enclosure including MCB,SPN 20 Amps,240 V, AC supply & plug top complete all as specified and directed. Havells Cat Part No DHDDCDP025202003 or equivalent in Makes as specified in PS.
Supply and fixing LED luminaire 600 mm x 600mm, 35/36 watt, 220 V,AC, Recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed with following specification :- (a) Lumen efficiency of luminaire should be more than 100 Lumen per watt. (b) Voltage operating range : 140 to 270 volts. (c) Temp operating range : Minus 10º C to Plus 50º C. (d) Power factor : Minimum 0.95. (e) THD : Max 10%. (f) IP rating : IP20.(g) CRCA pre coated housing. (h) LED driver of the make as of the luminaire,(j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Inbuilt Surge protection device for 4 KV.
S&F Galvanised steeI tubing,25mm bore, medium grade with all fittings , fixed to wall/ceiling and laid in floors complete all as specified and directed .
S&F 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed .
S & F exhaust fan ,steel body, heavy duty,AC single phase, 4 blades with self closing GI louver shutter suitable for operation on 220/230 volts of 300mm sweep,copper winding,1200 RPM and including three core copper flexible wire 1.00 mm dia drawn into and including PVC flexible conduit and hanging on wall with 4 Nos steel fasterners 10mm dia & 100mm long including wall hole and making good the disturbed surfaces as per existing complete all as specified & directed .
Supplying and fixing and commissioning of electric water heater (Gyser) storage type ABS body of capacity 25 ltrs, BEE appreoved 5 star rating, 230V,single Phase, AC supply inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined quoting complete with all accessories such as safety valve thermostate NRV, connection piece PVC connection for hot and cold water 3 core PVC insulated PVC sheated copper conductor flexible cable including 15 Amp plug suitable for existing socket and fixing material, 04 Nos nut bolt grouting in wall in PCC(1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and directed .
Supply, fixing and testing aesthetically designed LED street light luminiareis of 45 Watts system wattage for energy saving having IP 65/66 degree of protection,with minimum system efficiency as>85%,made of pressure die casting aluminum housing, power coated in graphite grey and heat resistant toughened glass with excellent thermal management and prismatic polycarbonate covers for ensuring efficient optics and uniform distribution of light fitting should have operating voltage range of 150-270 VAC,THD<20%,P.F>.95 and fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K complete all as specified and directed.
Supply, fixing and testing aesthetically designed LED flood light luminiareis of 70 Watts system wattage for energy saving having IP 65/66 degree of protection,with minimum system efficiency as>85%,made of pressure die casting aluminum housing, power coated in graphite grey and heat resistant toughened glass with excellent thermal management and prismatic polycarbonate covers for ensuring efficient optics and uniform distribution of light fitting should have operating voltage range of 150-270 VAC,THD<20%,P.F>.95 and fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K complete all as specified and directed.
Supply, install,commissioning and testing of commercial Air curtain unit of size 46″ x 78″ for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS -CRC 18 gauge square perforated suction grills,Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening as specified.
S&F bracket fabricated out of GI tubing, light grade, 40mm bore, bend to the shape as directed and of length 1.2 mtr complete with mounting MS clamp made of flat iron 45 x 5 mm of suitable length (04 pairs) including nuts, bolts etc of suitable size and painting to MS clamps with two coats of aluminum paint over one coat of red oxide primer complete all as specified and directed.
S&F shackle type,vitreous, porcelain white, brown or green insulator for working pressure 1100 volts, height 75 mm and dia 90 mm including galvanized mild steel straps of 31mm x 3mm size,12mm dia insulator bolts, washers and nuts complete all as specified and directed.
S&F pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998, errecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and white colour upto 1.5 metre height from top of PCC pedestal/coping of poles and numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed.
S&F Stay assembly comprising of 7/8 SWG galvanised stay strand complete with GI stay rod 16mm dia ,mild steel stay plate, stay bow,connecting bracket of suitable mild steel flat , nuts, bolts, washers,loop type insulators etc complete all as specified in electrical plate No I of SSR-2009 (Part- I) complete all as specified and directed.. Note:- Excavation and earth work , PCC shall be measured and paid separately under relevant items of BoQ’.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed.
S&F Aluminium conductor steel reinforced (ACSR), stretched on HT/LT poles without any kink and bends, of various sizes complete including fixing to insulator with aluminium binding wire and coloured sleeved jumper connection with PG clamps including cutting of tree branches falling on the site of work complete all as specified and directed . Note: The size of conductor shall be as directed by Engr-in- Charge.
Supply & fixing PVC insulated, heavy duty ,multi stranded aluminium conductor, PVC sheathed cable, 6 sqmm 2 core complete all as specified and directed .
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including GI strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 40mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with TMT bar 8mm dia both ways @100c/c. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.
Material & labour, for cutting existing road for taking out/laying of underground cable through GI pipe of dia 40mm/80mm including necessary earth work and making good to match with the existing surface with PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) complete all as specified and directed.
Supply, install, commissioning of 16 metre high 16 sided polygon highmast lighting system fabricated out of BS-EN 10025 or equivalent 355 Mpa material in two sections, hot dip galvanised (single dip) internally & externally having uniform coating thickness of 85/ 65 micron for bottom & top section respectively as per BS 729 and with one longitudinal weld and having no circumferential weld suitable for wind velocity of 180 Km/hr as per IS -875 (Part-3) duly provided with accessories like head frame, steel wire rope 6mm dia (7/19 construction with central core SS) trailing cable double drum winch, galvanised lantern carriage arrangement suitable for 09 luminaires symmetrically and end finial. The mast shall have an integral power tool installed inside the base compartment for its operation as per manufacturers design/ details complete all as specified and directed . Highmast light includes the following : -(i) Supply, and fixing of foundation bolts manufactured from special steel alongwith nuts, washers, anchor plates and templates etc as required as manufacturers recommendations suitable for design life not less than 25 years.(ii) Erection and commissioning of high mast with the help of suitable equipments and wiring of luminaries with all copper conductor, cable of suitable size & providing flexible steel conduit pipe ¾” for protection of cable. (iii) Drawing, design and casting of suitable shallow foundation with RCC M-25 mix concrete for high mast considering the safe bearing capacity of soil as 10 tonne/ Sqm at 2.50 metre depth duly approved by GE - 01 Job each. (iv) Casting of suitable foundation with RCC M-25 mix concrete for panel as per manufacturers recommendations. (v) Supply and fix LED flood light fitting luminarie 160 W with LED lamp, secondary optics made in pressure die cast housing and heat sink in aluminium extursion type with IP65 protection class - 08 Nos each (vi) Supply and fix integral aviation obstruction light comprising of aluminium housing with polycarbonite enclosures - LED type - 01 Nos Each (vii) Supply and installaton of control panel (KIOSK) (out door, double door) with auto control timer switch unit with digitial time switch of capacity 63 Amps tripple pole & neutral (TP&N) MCB incomer housing suitable for circuit for operation of mast including suitable control circuit for power tool motor complete as per manufacturer recommendations- 01 Jobs Each. (viii) All necessary Excxavation and earthwork in any type of soil including returning, filling and removal of surplus soil to distance not exceeding 50 metre completed all as specified and directed by Engineer-in-Charge. (ix) Contractor shall submit Manufacturer defect guarantee certificate for a period not less than 05 years.
Supply & fixing copper conductor cable, 1.5 sqmm, twin core core including PVC conduit of suitable size for making connection of street light fittings with suitable cable lugs, clamps, nut, bolts etc complete all as specified and directed.
N.G BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .