Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-Finance | ₹1.1 Cr | L1 | Accepted-Finance L1 |
| 2 | L2₹1.1 Cr+₹17,726.91 (0.17%)Rejected-Finance ANAND BHAWAN KC NANDI PATH BILASI TOWN DEOGHAR JHARKHAND 814113 | BILASI TOWN | DEOGHAR | JHARKHAND | 814113 | ₹1.1 Cr+₹17,726.91 (0.17%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.2 Cr+₹12.8 L (12.1%)Rejected-Finance AT STATION ROAD JAMTARA JHARKHAND 815351 | JAMTARA | JHARKHAND | 815351 | ₹1.2 Cr+₹12.8 L (12.1%) | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | shree ganesh construction L3 | RAVI ANAND L2 | M/S KISHOR KUMAR THAKUR L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. | 0.68 | Cum | 800.37 ₹544.25 | 715.2 ₹486.34 Lowest | 716.25 ₹487.05 |
| 2.00 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.INTERNAL WALL IF REQUIRED | 52.27 | Cum | 453.54 ₹23,706.54 | 405.28 ₹21,183.99 Lowest | 405.75 ₹21,208.55 |
| 3.00 | Taking down chaukhats in Windows including stacking serviceable materials within 15M. Lead and disposal of unserviceable materials with all leads all complete ap per direction of E/I.Out side wall window | 10 | Nos | 115.61 ₹1,156.1 | 103.3 ₹1,033 Lowest | 103.5 ₹1,035 |
| 4.00 | Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I | 44.8 | Cum | 127.12 ₹5,694.98 | 113.59 ₹5,088.83 | 113.25 ₹5,073.6 Lowest |
| 5.00 | Extra for earth work in hard soil as per specification & direction of engineer in charge (Vide classification of soil item B) | 22.4 | Cum | 12.99 ₹290.98 | 11.6 ₹259.84 | 11.25 ₹252 Lowest |
| 6.00 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). | 34.88 | Cum | 46.29 ₹1,614.6 | 41.36 ₹1,442.64 | 41.25 ₹1,438.8 Lowest |
| 7.00 | Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume) | 9.59 | Cum | 493.6 ₹4,733.62 | 441.07 ₹4,229.86 Lowest | 441.75 ₹4,236.38 |
| 8.00 | Providing and laying in position cement concete of soecified grade excluding the cost of centering and shuttering - All work up tp plinth level 1:4:8 (1 cement :4 coarse sand (Zone -III) :8 graded stone aggregrate 40 mm normial size) | 12.39 | Cum | 3,141.25 ₹38,920.09 | 2,806.98 ₹34,778.48 Lowest | 2,813.25 ₹34,856.17 |
| 9.00Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement | ||||||
| 9.10 | All works uptp plinth level | 14.04 | Cum | 4,476.26 ₹62,846.69 | 3,999.93 ₹56,159.02 Lowest | 4,009.5 ₹56,293.38 |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
27 Jan 2026, 11:00 amClosed
Nodal Officer
e-Procurement Cell, Office of The Executive Engineer, Building Construction Department, Building Division, Deoghar
Proposed Setting Up of Integrated Public Health Laboratory at Sadar Hospital at Deoghar for the Year 2025-26
2026_BCD_109426_1
BCD/EE/16/DEOGHAR/2025-26
Open Tender
Civil Works - Buildings
Item Rate
270 days
Deoghar
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹2.8 L
4 Jul 2026
21 Jan 2026
28 Jan 2026
21 Jan 2026
27 Jan 2026
21 Jan 2026
Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.INTERNAL WALL IF REQUIRED
Taking down chaukhats in Windows including stacking serviceable materials within 15M. Lead and disposal of unserviceable materials with all leads all complete ap per direction of E/I.Out side wall window
Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
Extra for earth work in hard soil as per specification & direction of engineer in charge (Vide classification of soil item B)
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume)
Providing and laying in position cement concete of soecified grade excluding the cost of centering and shuttering - All work up tp plinth level 1:4:8 (1 cement :4 coarse sand (Zone -III) :8 graded stone aggregrate 40 mm normial size)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement
All works uptp plinth level
All works above plinth level upto floor V level
Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 10mm./28 mm / 32mm dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 12mm. 16mm 20mm 25mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Centering and shutteing including struting, propping etc and removal of form for Foundations, footings, bases for columns, etc for mass concrete
Centering and shutteing including struting, propping etc and removal of form for Suspended floors, roof , landings , balconies and access platform
Centering and shutteing including struting, propping etc and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shutteing including struting, propping etc and removal of form for Columns, Pillars, Piers, abutments, Posts and struts
providing designation 75 B brickwork in C M ('1 :6 ) in foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing. taxes and royalty all complete as per building specification and direction of E/l.
Providing Designation 100A B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 112 mm thick reinforced designation 100 A brick work vuith fly ash lirne brick (FLAG)confirming to lS 12894-1990 (9"x4'5"x3" ) in C.M. ( 1 . 4 ) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials,n caffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specificationand direction of E/|.
Supplying,frtting and fixing M.S. grill made of 20x6cmm M.S. flat as per approved design and drawing, properly fabrlcated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/1Wt @ 15Kg / sqm
Supplying fitting and fixing glass panes including supplying putty, beads and nails after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/1.
Water proofrng for Old and New Roof Slab :- Providing and laying waterprooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible,material applied with brush, roller or spray for wate proof i n g coating as per manufactlrer specificatio With following steps :-
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dLrst, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from sofftt to identify seepage, leakage. On identiiication of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joinis such as those betr,veen the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the sl u rry ?!gc!ylic polyrner Repai rin g su rface irreg ularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modilied repair moriar ir;cluding a coat of bonding agent of the same with ceme nt slurry rncluding all rnaterial, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, llexrble cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/SqmUcoat For the fJUrpose of n'ieasurernent tite entire treated surface will be measured."
(c) :2nd Cr:ai :-T,: apply the 2nd coat of two component acrylic modified, reatiy to-use, flexible cementttious material right angle to the '1st coat over the glass fibre liad surface. 2nd coat should be applied @0.7 kgl Sqrnt/coat. For the pltrpose of measurement the entire treated surface will be rneasurecl." Alte r three days of drying the 2nd coat, therainwater ouilets to be plugged and ponding test to be done for 48 hours to rrjerrtify se epage, leal<age from soffit and if found necessary rectification lo be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectifcation to be done as per satrsfaction of E/C protected from damage before screed over it. Watqr proofing Brand:*Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A. Acrylic copolmer, Part B Specially graded cementitious powder - Density 1.6 l.rg/l (mixcd density) at +27oC Tensile Strength - 2 lllmm2 after 28 clays (with Fibre cloth) (According to ASTM D 2370)Prillcut Bond Streric;tl-r '-2 I'J/mm2 (concrete lajlqry) (Aqgcrdlglq ISO 4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.'15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Clot (Accordrng to ASTM D 2370)
(d) Protection of treated surface with PCC- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( '1:120) towards tlre rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mrn gap betuieen the panel joint. lntegralwater proofing admixture conforming to lS 2645 @ of 100 ml per bag of of cement to be added in the scree d concrete(pard separately for thts ltems).-All corners shall be charrmfered with 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface slrould be packed properly with rich concrete and the peripheral mouih to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose ofrreasurement the entire treated surface will be measured."
(e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc Warranty for Five years.
Covering of treated surface wrth PCC :- Providing 50mm thick Cementn Concrete M20(1:'1.5:3) r'naintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
Providing and mixing Liquid lntergral water proofing compound in Conctrete or plaster as per rnanufacturer specificatioqand as per cjirection of Eng - in Charge Brand- Sika Plastocrate plus, MYK proof WP 1 0, Fosroc-Cc.rnplast X4211 C, Dr fixit Pidiproof LW+ or Equivalent
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.Tiolet,staircase,shaft wall
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5with 5% cico or any other approved water proofing compoundincluding taxes and royalty all complete as per building specification and direction of E/l.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Same qty Structure work & Window Grill
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Brick
Chips
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.l. box etc as required. Group C
Wiring for group controlled (looped) light point/ fan point exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit etc as required. Group C
S/F light plug point with modular type accessories :Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch. corutection, painting etc. as required (For light plugs to be used in non residential buildings)
S/F power plug point with modular type accessories :Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fxing 6 pin 15/16 amps modular socket outlet and l5/16 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
S.P 5/6 amps, one way modular switch, ISI Marked
S.P 15/16 amps, one way modular switch, ISI Marked
5 pin 5/6 amps, modular socket Outlet, ISI Marked
6 pin 15/16 amps, modular socket Outlet, ISI Marked
Supplying and fixing following size / modules , GI box along with modular base & cover plate for modular switches in recess etc as required.
1 or 2 module (78mmx 78mmx 45mm)
4/5 module mm x 140mm x 50mm
6 module (78mm x 205mm x 50mm)
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Power plug widng in PVC conduit (2 x 4 sq. nun) :-Wiriug for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.nrm FR PVC insulated copper conductor single core cable for loopcarthing etc as required..
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2x1.5 sq.urm+ 1x 1.5 sq.mm earthwire
2 x2.5 sq.mm + I x2.5 sq.mm earth wire
2 x l0 sq.mm+ I x6 sq.mm earthwire
4 x 6.0 sq.mm +2x6.0sq.mm earthwire
4 x 10.0 sq.mm +2x10.0sq.mm earthwire
S/F S.P. MCB DB :- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, compiete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way, Double door
S/F S.P. MCB DB :- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, compiete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4way (4 + 12), Double door, Horizontal type
6way (4 + 18), Double door, Horizontal type
S/F S.P. MCB :-Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, "C" curve,miniature circuit breaker suitable for.inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required.
6/32 amps, Single pole
6/32 amps, DP
50/63 amps, DP
40/63 amps, TP
Supplying and fixing following rating, double pole, (singte phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25amps, DP
40 amps, DP
63 amps, DP
Providing and fixing M.V. danger notice plate of 2O0 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
S/F ceiling rose :-supplying and fxing 2 pin 5 amp. Ceiling rose on the existing junction box/wooen block including connection etc. as required
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed PVC conduit as required.
S/F Batten holder :-supplying and fixing Batten / Angle holder including connection etc as required.
Supply & fixing of modular telephone cord outlet & switch box including connections but excluding modular plate etc. as required.
Supply & fixing of modular TV antenna socket outlet & switch box including connections but excluding modular plate etc. as required.
S/F Modular boxes, base & cover plate :- Supplying and fixing following size / modules , GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module (78mmx 78mmx 45mm)
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm copper conductor PE insulated, with PVC shield in the existing surface/ recessed PVC conduit as required.
Supplying, drawing, of 0.5mm dia (2 pair) FR PVC insulated copper conductor , unarmoured telephone cable in existing surface/ recessed PVC conduit as required
Supplying, drawing, of 0.5mm dia (4 pair) FR PVC insulated copper conductor , unarmoured telephone cable in existing surface/ recessed PVC conduit as required
P/F G.I. lightning condutor final :- Providing and fixing of lighting conductor finial , made of 25mm dia 300mm long , G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc. complete as required.
P/f G.I. lightning conductor tape in horizontal providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required.( for Horizontal run ).
P/F G.I. lightning conductor tape in vertical providing and fxing G.I. tape 20mm x 3rrm thick on parapet or surface of wall for lightning conductor complete as required.( for Vertical run )
MV cable :- supply of ISI marked aluminium cable conductor XLPE PVC insulated cable as per IS : 7098 armoured, served shealthed 1100V grade with termination and laying of cable make :- finolex, polycab, Havells universal- 50 sqmm X 3.5 Core armoured AL Cable for SEB supply
MV cable upto 120 sqm in ground without sand cover Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size Cxceeding 35 sq mm but not exceeding 120 sq. mm in the existing RCC/HUME/STONEWAREA4ETAL pipe as required.
Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to13:374,.2019 including wiring the down rods of standard length (upto 30cm) with l.Ssq.mm. FR PVC insulated, copper wire suitable for 230V 50H2, single phase supply etc. complete as required.make polar/bajaj/havells/philips. 1200mm (48") Ceiling Fan
S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50H2, single phase supply etc. complete as required. 20/22W LED Tube light
LED bulb 9W/10W:- supplying and fixing of LED 9W/10W bilb and acessories as required make :- Bajaj/havells/ phillips.
S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existingpole/pipe for supply voltage 1C[.Z70Y AC,50Hz. Luminarie shall be confirm tolS:,1,0322part-5/section-5 and shall be complete with all neccssary accessories as required 50W LED Flood light
Supplying and fixing recess mounted downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. 10/12w LED DOWNLIGHT
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,lP 65 protection and complete u.,ith integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Earthing with G.I. Earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( with charcoal or coke and salt).
Earthing with copper . Earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.( with charcoal or coke and salt).
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25x5 mm copper strip in 40mm dia G. I. pipe from earth electrode including connection with brass nut, bolt, spring washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Prividing and Fixing of GI lightning conductor Final made of 25mm dia 300 mm Long GI tube , having single prone on top with 85mm dia 6mm thick GI base plate including holes etc complete as required
Providing and fixing GI-tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as required.(for vertical run)
Providing and fixing GI-tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as required.(for horizontal)
Providing and fixing testing joint, made of 20 mm x 3 mm thick gi strip, 125 mm long with 4 Nos. brass bolts, nuts check nuts and spring washers etc. complete as required.
Providing and laying GI tape, 32 mm x 6 mm thick from earth electrode directly in ground as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately
Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 SQM
Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Finishing walls with Acrylic Smooth exterior paint of required shade,New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and m anufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately):Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.
Pre-laminated particle board with decorative lamination on both sides
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Bend 87.5° 110 mm bend
Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 18.53.1 15mm nominal bore
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.15 mm nominal bore, weighing not less than 32 gms
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the wallswherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing PTMT grating of approved quality and colour.125 mm nominal dia with 25 mm waste hole
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
15 mm nominal dia Pipes
20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
25 mm nominal dia Pipes
32 mm nominal dia Pipes
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
Polythene water storage tank of ISI mark (eg sintex/sinter/himgiri/gangotri ) with cover & locking system
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 178 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.75 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
75 mm Coupler
110 mm Coupler
75mm single pushfit coupler
110mm single pushfit coupler
75 mm single tee with door
110mm single tee with door
75 mm single tee without door
110 mm single tee without door
75mm bend 87.5
110mm bend 87.5
75mm shoe (plain )
110mm shoe (plain )
Underground Sump (4000 L)
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
0.63 MM (24 gauge) Galvanized Sheet Steel
0.8 MM (22 gauge) Galvanized Sheet Steel
1.0 MM (20 gauge) Galvanized Sheet Steel
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Damper
Actuator
N.S Items Revolving Chair With Arm Synchronic tilt mechanism (GODREJ INTERIO ACE FULL BACK CHAIR) (Product id: 5116877-5116877-95084053146)
OCEAN LIFE SCIENCE CORPORATION Laboratory Steel Furniture Side bench with rack and table top OCEAN LIFE SCIENCE CORPORATIONR (OLSC-IWB)
BETCO Laboratory Steel Furniture Island bench with table top BETCOR (BETCO-LB-202)
Providing and laying of brick bats including cost of material, labour charges etc complete as per specification & E/I
Hermetically Sealed Sliding Door System: Fabrication, Supply, installation, testing & commissioning of sliding type Hermetically Sealed door having high density particle board cores/ CFC free Polyurethane, high pressure laminate face on both sides, viewing window 300 x 300mm. Size: 1500 x 2100 mm (W x H) as per direction of EIC. Automatic Doors: Provided with Radar Switch - 2 Nos., Foot Switch - 2 Nos. and Photocell Sensors. Automatic Door (1500 mm x 2100 mm) Approved makes -Metaflex /REBBON / MDD Engineering/ Altos / Dormed/ Meditech
Supply, installation, testing and commissioning of modular OT Wall and corner panels with insulated prefabricated puff Panels. The OT wall shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of
80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3. The thickness of Puff shall be minimum 40 mm. The sheet panel shall be of indigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mmlong SS fasteners which shall be fully threaded and power drilled
The Panels of walls and ceilingshall be tied together by suitable SS coving. The individual wall panels of wall and ceiling shall be tied together by suitable SS coving. The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap
All wall-mounted equipment shall be flush mounted and sealed in operation theatre. All the sharp edges and corners shall be in radius to avoid bacterialcontamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wall-mounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. Thework should be executed as per the directions of Engineer–in-Charge.
TB LAB, BACTERIOLOGY,EXTRECTION,MASTER Partition
Supply, installation, testing and commissioning of modular OT Wall and corner panels with insulated prefabricated puff Panels. The OT wall shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of
The thickness of Puff shall be minimum 40 mm. The sheet panel shall be ofindigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mm long SS fasteners which shall be fully threaded and power drilled. The Panels of walls and ceiling shall be tied together by suitable SS coving. The individual panels of wall and ceiling shall be tied together by suitable SS coving.
The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap. All wall-mounted equipment shall be flush mounted and sealed in operation theatre
All the sharp edges and corners shall be in radius to avoid bacterial contamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wallmounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per thedirections of Engineer–in-Charge.
Supply, installation, testing and commissioning of modular OT ceiling panels with insulated prefabricated puff Panels. The OT ceiling shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of 0.80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3.
The thickness of Puff shall be minimum 40 mm. The sheet panel shall be ofindigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mm long SS fasteners which shall be fully threaded and power drilled. The Panels of walls and ceiling shall be tied together by suitable SS coving. The individual panels of wall and ceiling shall be tied together by suitable SS coving.
The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap. All wall-mounted equipment shall be flush mounted and sealed in operation theatre
All the sharp edges and corners shall be in radius to avoid bacterial contamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wallmounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per thedirections of Engineer–in-Charge.
Providing Epoxy flooring self leveling type on strong base in desired colour/design as approved by Engineer-in-Charge. Resin for epoxy is to be of floor grade type i/c appropriate hardner and filler material. with 5 year defect liability period
ETP Supplying, installation, testing & commissioning of Effluent Treatment Plant for the following duty:
Nature of waste water - Lab effluent
Daily Avg. Flow = 2 cum/Day
Reuse of ETP treated water after treatment. Horticulture, Landscaping, irrigation etc.
Influent Characteristics (considered)
BOD5 - 200-250 mg/liter
S. Solids - 250-300 mg/liter
COD - 400- 600 mg/liter
Oil & Grease ` - <50 mg/liter
Effluent discharge standard after treatment:
BOD5 - Less than 30 mg/liter
S. Solids - Less than 50 mg/liter
COD - Less than 100 mg/liter
Oil & Grease - < 5 mg/lt
Supply, installation, testing & commissioning of Screens
Mild Steel Suitable Sized Manually operated Bar Screen as per following specifications-1 nos
Cleaning :- Manual Screen
MOC :- MS
Supply, installation, testing & commissioning of Raw effluent lifting pumps complete with all accessories, motor of required capacity. Pumps shall have following duty: 1 Lot
Flow rate (each) = 0.25 m3/hr
Head = 8-10 m
Make = Kirloskar/Wilo/Eqv.
Supply, installation testing and commisioning of physico-chemical treatment, the system shall be comprising of dosing pump, dosing tank, and Agitators.1 Lot.
Dosing Units
Alum Dosing system
Poly Dosing System
Lime Dosing System
Tube deck media in settling tank
Providing and fixing all interconnecting plant piping of required MOC as MS/UPVC and isolation control valves for making the piping arrangement complete within the battery limits.1 Lot.
Supply, installation, testing & commissioning of SBR feed Pumps with CI casing & CI impeller complete with all accessories, motor of required capacity. The pumps shall be complete with all accessories. Pumps shall have following duty: 2nos
Flow rate (each) = 0.25m³/hr
Head = 8-10 m
Make = WILO/Kirloskar/Eqv.
Supply, installation, testing & commissioning of SBR Based Biological system comprising of the following equipments:1 Lot.
Air Blowers For SBR tanks
Capacity :Apprx. 5-10 m3/hr. @5000-5500 mmwg
Type Twin Lobe
Fine Bubble Diffusers
Qty: 1 Lot
Decanter 1 Nos
Make: PS aqua/ Grannus Water and Env. Solution Pvt. Ltd.
Pipes and fittings for Air piping and Air Grid 1Nos
Supplying, installing, testing, commissioning of Centrifugal Horizontal Filter Feed pumps Complete in CI body & CI impeller with motor, and all other accessories required to complete the system.2 Nos
Pumps = 02 Nos.(1w + 1s)
Flow rate (each) = 0.25 m³/hr
Head = 25 - 30 m
Make - Kirloskar/Eqv
Supply installation testing & commissioning of Sludge transfer feed pumps for sludge transfer to SHT complete with all the accessories, motor of required capacity. The
Flow rate (each) = 0.5/1.0 m³/hr
Head = 8-10 m
Make - Kirloskar/Eqv
Supplying, Installation, testing and commissioning of Chemical dosing system comprising of Sintex Tank with inlet/ outlet connection, piping and valves along with metering pump for dosing. 1 Set
Supplying, installing, testing, commissioning of Sludge Bag System of suitable size for the dewatering of sludge generated per day.1 Set
Make: Grannus Water and Env.Solution Pvt. Ltd.
Mode of operation: Manual
Supplying, installation, testing & commissioning of FRP vessel filter with frontal piping and Valves with all the required accessories. Filter shall include media, standard fittings like pressure gauges, sampling cock, rinse drain.
Dual Media Filter 1 Nos
Dia : 150 mm
Filter media: Fine and coarse sand, pebbles and gravels
Make: PS aqua/ Grannus Water and Env.Solution Pvt. Ltd.
ELECTRICAL PANEL AND ACCESSORIES
Total cost for above work (A) ( In Rs.)
Supply, installation. Testing and commissioning of following Tanks In MSEP/HDPE
Flash Mixer
Flocculation tank
Settling Tank
Break Tank
SBR Tank
Intermediate Water Tank
MAIN LT PANEL
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of panel and Panel fabricated out of 14 gauge CRCA sheet steel in cubicle compartmentised free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel `T’ section and / or flats wherever necessary. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specification and final approved shade. 2 Nos. earthing terminals shall be provided for all panels. Panels shall be suitable for 415 V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in all panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels.
METER BOARD
Incoming
1 No. 160. Amps 4 Pole MCCB and ON/OFF/Trip & shunt trip coil.
Digital energy meter (conzerve – EM 6400NG with RS-485 or equivalent) of accuracy class-I, with 3 Nos. 160/5 amps 15VA CTs.
Phase indicating light shall be protected by suitable rating MCB’s.- 3 Sets
Breaker ON / OFF / TRIP indicating lights with control MCB’s. - 1 Set
Bus Bars
300 amps TPN Aluminium bus bars with colour coded heat shrinkable insulating sleeves - 1 Set.
Outgoing
1 No. 100 Amps TPN Pole MCCB and ON/OFF/Trip
6 No. 40/63 Amps TPN Pole MCCB and ON/OFF/Trip
Panel as described above.
Supply and fixing of Computer terminal (RJ-45) outlet in existing box with modular plate
Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed PVC conduit as required.
Double Skinned Floor Mounted Air Handling Units with Pre & Fine Filter
The face velocity across cooling coil shall be limited to 152 MPM maxm.The capacity of Air-handlers shall be as follows: Fan Outlet velocity Max 9.6 m/s
(For AHU No. Please Refer Basic Of Design & AC Tender Drawing )
AHU / LAB - 2 x 8.5 TR Air Cooled Condenser Outdoor Unit
5000 CFM Supply Blower, 6 Row CC, 125 mm Static , Pressure
for Supply Fan , 5500 CFM Ex. Blower , 75 mm Static Pressure
for Exhaust fan )
Supply Installation, testing & commissioning of Air Cooled Ductable Split Units. - Outdoor & Indoor unit shall connected with DX coil, refrigerant piping, firstcharge of refrigerant & oil, HP/LP cutout, thermostatic expansion valve, distributor, starter and other necessary controls to form a factory tested compact unit. The outdoor unit shall have condenser coil, fans with motor & drive, copleand scroll compressors, panel etc. The ductable units should be complete with programable microprocessor panel (BMS Compatible). ( Make: LG / Blue Star / Daikin) 8.5 TR With Scroll Compessor
Double Skinned Floor Ceiling Suspended Type Fan Filter Unit with Hepa Filter
FFU - 500 CFM with Hepa Filter, 40 MM of WC
FFU - 750 CFM with Hepa Filter, 40 MM of WC
FFU - 850 CFM with Hepa Filter, 40 MM of WC
FFU - 900 CFM with Hepa Filter, 40 MM of WC
DUCTING, GRILLS,DIFFUSER AND INSULATION
Supply,installation and testing of powder coated aluminium extruded grills/diffusers as per specifications given in tender and of following sizes:
Single Louvered supply / Return Air registers (Grill)
Supply / return suare ceiling air terminals (diffusers)
Fresh / Exhaust air louvers with bird screen & damper
Flexible connection for AHU/FCU madeup of f/r fabric compelte with flange
Supply,installation and testing of multiblade type GI Duct Damper for duct/collars to be provided with suitable links and quadrants for control of volume of air
Supply and Application of Acoustic Insulation Inside the Duct with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.conforming to standard specification. 15 mm thick open cell nitrile rubber.
Supply & Installation of Thermal Insulation on Ducts not exposed to sunlight using Closed Cell Class O Nitrile Rubber Elastomeric Insulation of Density 40 - 60 Kg/m3, Thermal Conductivity of 0.037 W/mk at 20 Celcius Mean Temp. and µ≥7000 (without any additional vapour barrier) and with factory laminated aluminium foil of minimum 60 Microns thickness having weight of 193 gsm as per EN ISO 2286-2, tensile strength shall be 90N/15mm as per EN ISO 527-3 with elongation > 10% as per EN ISO 527-3; to be applied on Ducts using manufacturer's recommended Rubber based Adhesive in a blend of Solvents. 25 mm thick (Class O) Foil for Supply Air Duct
MOTOR CONTROL CENTRE
i) For 2 x 8.5TR Outdoor Unit
Supply, installation, testing and commissioning of Cubical type sectinalised floor standing switch board of 31 MVA fault capacity at 415 V complete with 4 strip, 63 A capacity Aluminium Bus - Bar Electrolytic grade, cable alley, switchgears of following capacity & as per specifications.
i) INCOMER
OUTGOINGS
i) For 02 Nos. Outdoor Unit
Controls & interlocking accessories as required. LOT
Power Cabling (PVC insulated and PVC sheathed, armoured, Aluminium Conductor of 1.1 KV grade of following sizes.
i) For Compressor 3.5C x 16 Sq. mm Aluminium Conductor
ii) For Indoor Unit Blower & Compressor 3C x 4 Sq. mm Aluminium Conductor
iii) For Condenser Fan 2C x 1.5 Sq. mm Copper Conductor
Control Cabling ( PVC insulated & PVC sheathed, armoured, Copper Conductor of 1.1 KV grade of following sizes.
6C x 1.5 Sq. mm Copper Conductor
Supply & laying of 8 SWG GI wire.
Add 18 % GST
Add 1% Labour Cess
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
F2.pdf
Tender Documents • 10.33 MB
BOQ_147822.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .