Loading…
Loading…
Tender Value
₹4.7 L
EMD Value
₹9,400
Closing Date
24 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
PND WORKS
12 conditions · 1 needing a document upload
No Technical & Financial eligibility criteria are required for the work costing upto 50 Lakhs but recent documents should be submitted in evidence of tenderer's capacity to carry out the work efficiently and of sound financial capacity. In addition, the tenderer should submit Electrical Contractor license, recent Income tax Return clearance, pan card, GST registration certificate & the tenderers shall submit a self- declarationas per tender condition etc. Note: Non-Submission of Valid Electrical Contractor License, Recent Income Tax Return Clearance or Balance sheet, GST Registration Certificate, PAN Card by the Bidder shall result in summarily rejection of his/their bid.The firm may submit work experience certificate related to electrical works, Bank Mandate form, Cancelled Cheque, EPF, ESI, Trade License, etc (If available).The tenderer shall have submitted an undertaking that he is not blacklisted or debarred by Railways or any other Ministry/Department of Govt. of India from participation in tender on the date of opening of bids, either in individual capacity or as a member of the partnership firm or JV in which he was/is a partner/member (Format in Annexure-VA). Concealment/wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
6 conditions · 4 needing a document upload
GST registration certificate along with its supportive documents as per GCC 2022 or its latest amendments must be summitted by the firm. Note:- Non-submission of this document by the bidder shall result in summarily rejection of his/their bid.
Recent Income Tax Return clearance 'OR' Balance sheet must be submitted by the firm. Note:- Non-submission of this document by the bidder shall result in summarily rejection of his/their bid.
PAN Card must be submitted by the firm. Note:- Non-submission of this document by the bidder shall result in summarily rejection of his/their bid.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
GCC 2022 and its all amendments from Railway Board will be followed in this work.
Provision of store of shop No. 24 and raising of floor height of Godown for electrical (G) works under jurisdiction of Dy.CEE/G/KPA.
KPA-EG-OT-04-26-27
KPA-EG-OT-04-26-27
Open
Works - General
9 Months
North 24 Parganas, West Bengal
₹0
₹9,400
24 Aug 2026
31 Jul 2026
10 Aug 2026
55 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,70,883.53 | ||
| — | — | — | 3,021.44 | ||
| Supply, erection, testing and commissioning of LT XLPE cable gland with aluminium sockets (4 Nos.) suitable for LT 4 core 120-185 sq.mm XLPE aluminium conductor armoured cable. | — | 8.00 | — | — | |
| — | — | — | 26,434.8 | ||
| Cable trenching in underground by digging earth and protection of the cable with sand and brick and filling with earth after laying of cable including making good of surface & damages as per CEE/E.Rlys Drg. No. E4/GPST/033/87. | — | 120.00 | — | — | |
| — | — | — | 8,681.1 | ||
| Supply & laying of 100mm dia. heavy duty GI pipe conforming to IS:1239 (Part-1) of latest amendment in underground by cutting trench in road / wall / platform / surface / across the Railway track or recessing in wall / platform / along the Railway track etc. with making good of damages after laying of pipe. (Make as per Annexure-I) | for details. | Breakup | — | — | |
| — | — | — | 2,613.8 | ||
| Laying of cable through the trench, GI pipe, HDPE pipe, PVC pipe, cable tray, cable duct, wall surface etc. as per IS:1255 of latest amendment with making good of damages after laying of cable and connection with switchgears along with necessary materials as required. N.B: only cable will be supplied by Rlys, all other materials required during execution of work and connection are to be supplied by the firm. | — | 140.00 | — | — | |
| — | — | — | 46,335.6 | ||
| Laying, jointing, connection, testing & commissioning of LT cable of different sizes above 95 sq.mm along the wall by necessary clamping arrangement including socketing and termination with epoxy end jointing where necessary. Clamps should be made from 50mm x 6mm MS flat. N.B: Only cable will be supplied by Rly, all other materials required during execution of work and connection are to be supplied by firm. | — | 360.00 | — | — | |
| — | — | — | 23,020.34 | ||
| Supply, installation, connection, testing and commissioning of 4 pole, 250A, 415V, 50Hz MCCB of 35/36kA breaking capacity with adjustable thermal magnetic trip unit, over load, earth fault and short circuit protection in a suitable powder coated sheet steel enclosure with all accessories including connection with gland, socketing, cable entry box etc. as required (Make as per Annexure-I). | for details. | Breakup | — | — | |
| — | — | — | 21,693.39 | ||
| Supply, installation, connection, testing and commissioning of 4 pole, 160A, 415V, 50Hz MCCB, 35/36kA breaking capacity with adjustable thermal magnetic trip unit, over load, earth fault and short circuit protection in a suitable powder coated sheet steel enclosure with all accessories including connection with gland, socketing, cable entry box etc. as required. (Make as per Annexure-I) | for details. | Breakup | — | — | |
| — | — | — | 1,501.55 | ||
| Supply, installation, connection, testing and commissioning of suitable size 4 pole copper busbar of 100A capacity including 4 way sheet steel enclosure having a minimum size of 400mm x 300mm x 150mm with proper fixing arrangement along with incoming and outgoing cable connection with socketing and gland etc. | for details. | Breakup | — | — | |
| — | — | — | 9,397 | ||
| Wiring of main / sub-main line in casing-capping / conduit with 02 Nos. 6 sq.mm (for phase and neutral) and 01 No. 2.5 sq.mm (for ECC) copper wire in suitable size heavy gauge PVC pipe including all other accessories, and making good of wall / ceiling surface as its original condition. Copper wire should be PVC insulated multi strand single core FR/ZHFR/FRLSH 1100V grade conforming to IS:694 of latest amendment (make as per Annexure-I). | — | 50.00 | — | — | |
| — | — | — | 38,982.5 | ||
| Wiring of main / sub-main line in casing-capping / conduit with 02 Nos. 4 sq.mm (for phase and neutral) and 01 No. 1.5 sq.mm (for ECC) copper wire in suitable size heavy gauge PVC pipe including all other accessories including make good of wall / ceiling surface as its original condition. Copper wire should be PVC insulated multi strand single core FR/ZHFR/FRLSH 1100V grade conforming to IS:694 of latest amendment (make as per Annexure-I). | — | 250.00 | — | — | |
| — | — | — | 40,500.68 | ||
| Wiring of light, fan, exhaust fan, wall bracket fan, call bell etc. in casing-capping / conduit with 02 Nos. 1.5 sq.mm (for phase and neutral) and 01 No. 1.5 sq.mm (for ECC) copper wire in suitable size heavy gauge PVC pipe with provision of suitable size PVC board, switch, fuse, LED indicator, ceiling rose, angular holder & all other required accessories with fixing & commissioning electronic fan regulator incase of fan point (excluding supply of fan & regulator) including make good of wall / ceiling surface as its original condition. Copper wire should be PVC insulated multi strand single core FR/ZHFR/FRLSH 1100V grade conforming to IS:694 of latest amendment (make as per Annexure-I). | — | 83.00 | — | — | |
| — | — | — | 3,113.32 | ||
| Wiring of 6A plug-socket point in casing-capping / conduit with 02 Nos. 2.5 sq.mm (phase and neutral) and 01 No. 1.5 sq.mm (for ECC) copper wire in suitable size heavy gauge PVC pipe and suitable size PVC board consisting of 01 No. 6A, 3/5 pin plug-socket, 01 No. 6A switch, 01 No. 6A kit-kat fuse and all other required accessories with making good of wall / ceiling surface as its original condition. Copper wire should be PVC insulated multi-strand single core FR/ ZHFR/ FRLSH 1100V grade conforming to IS:694 of latest amendment (Make as per Annexure-I). | — | 14.00 | — | — | |
| — | — | — | 4,455 | ||
| Wiring of 16A plug-socket point in casing-capping / conduit with 02 Nos. 4 sq.mm (phase and neutral) and 01 No. 2.5 sq.mm (for ECC) copper wire in suitable size heavy gauge PVC pipe and suitable size individual PVC board consisting of 01 No. 16A, 3/5/6 pin plug-socket, 01 No. 16A switch, 01 No. 16A kit-kat fuse, 01 No. LED indicator and all other required accessories with making good of wall / ceiling surface as its original condition. Copper wire should be PVC insulated multi-strand single core FR/ ZHFR/ FRLSH 1100V grade conforming to IS:694 of latest amendment (Make as per Annexure-I). | — | 6.00 | — | — | |
| — | — | — | 2,911.2 | ||
| Wiring of multi-plug point in casing-capping / conduit with 02 Nos. 4 sq.mm (phase and neutral) and 01 No. 2.5 sq.mm (for ECC) copper wire in suitable size heavy gauge PVC pipe and suitable size individual PVC board consisting of 03 Nos. 6A - 3/5 pin plug-socket, 03 Nos. 6A switch, 01 No. 16A -3/5/6 pin plug-socket, 01 No. 16A switch, 01 No. 16A kit-kat fuse and 01 No. LED indicator and all other required accessories with making good of wall / ceiling surface as its original condition. Copper wire should be PVC insulated multi strand single core FR/ ZHFR/ FRLSH 1100V grade conforming to IS:694 of latest amendment (Make as per Annexure I). | — | 4.00 | — | — | |
| — | — | — | 11,501.7 | ||
| Supply, installation, testing & commissioning of 8 way double door SPN MCB DB with copper busbar consisting of (i) 40-63A, 10kA breaking capacity, DP MCB - 1 No., (iii) 6-32A, 10kA breaking capacity, SP MCB - 6 Nos. with neutral link, DIN rail and all other accessories (Make as per Annexure-I). N.B. Ratings of MCBs will be decided by Rly. authority. | for details. | Breakup | — | — | |
| — | — | — | 8,220 | ||
| Supply & testing of LED Tube light, T-8, 4 ft. length, 18-22W (Retrofit type), SMD LED chip, life span of LED>/= 50,000 burning hours, CRI >/= 70, system efficacy >/= 120 Lm/W, color temperature: 6500 K (cool white), PF >/= 0.9 with inbuilt driver and driver efficiency >/=85% with aluminium / polycarbonate housing & polycarbonate diffuser, IP 20 suitable for 220 -240V AC, 50Hz. (Make as per Annexure I) | — | 30.00 | — | — | |
| — | — | — | 3,150.6 | ||
| Supply of batten suitable for 1 No. LED tube light of 4 feet long, both side holder, without ballast and starter with copper wiring. | — | 30.00 | — | — | |
| — | — | — | 4,714.2 | ||
| Fixing, connection, testing and commissioning of LED tube light fittings with batten for indoor use with suitable size GI clamps and GI nut bolts and PVC insulated twin copper flexible cord as connected lead including old fittings to be removed. | — | 30.00 | — | — | |
| — | — | — | 20,578.9 | ||
| Supply & testing of 60W (approx.) LED luminaries for street / girder lighting in pressure die casted aluminium alloy housing with toughened glass cover having SMD LED chip, CRI >/= 70, system efficacy >/= 100 Lm/W, color temperature: 6000 +/- 500K, PF>/= 0.95, life span of LED >/= 50,000 burning hours, IP 66 or better suitable for 220-240V AC, 50Hz. (Make as per Annexure-I) | — | 10.00 | — | — | |
| — | — | — | 2,233 | ||
| Installation, connection, testing and commissioning of LED street/girder light of different capacity including all accessories and old fittings are to be removed, if any. (N.B.: All materials required during execution of the work and connection are to be supplied by the firm) | — | 10.00 | — | — | |
| — | — | — | 4,326.5 | ||
| Supply, fixing & commissioning of MS pipe 40/50 mm dia., 3 feet long bend type with suitable MS clamp (Two pair), nut, bold & washer for fixing of MS pipe for street lights. | for details. | Breakup | — | — | |
| — | — | — | 56,628 | ||
| Supply of BLDC ceiling fan of 1200mm sweep, energy efficient 5 star rated, remote controlled, double ball bearing suitable for single phase, 230V AC, 50Hz conforming to IS:374 of latest amendment with accessories including remote, canopies, nuts, bolts, clamps etc. (Make as per Annexure-I) | — | 24.00 | — | — | |
| — | — | — | 3,131.76 | ||
| Installation, connection, testing and commissioning of the ceiling fan by suitable size GI clamps made of GI flat / 'S' hook & GI nut-bolts including PVC insulated twin copper flexible cord as connected lead (N.B.: All materials required for execution of the work and connection are to be supplied by the firm) | — | 24.00 | — | — | |
| — | — | — | 50,205.45 | ||
| Supply, fixing, connection, testing and commissioning of wall bracket fan, 400mm sweep suitable for single phase 220-230V, 50Hz supply including all accessories (Make as per Annexure-I). | for details. | Breakup | — | — | |
| — | — | — | 59,800.92 | ||
| Supply of BLDC wall mounted (girder) air circulator propeller fan of 750mm sweep, 160-200W suitable for single phase, 220-230V 50Hz AC. (Make as per Annexure-I) | — | 4.00 | — | — | |
| — | — | — | 4,212.4 | ||
| Installation, connection, testing and commissioning of the BLDC wall mounted (girder) air circulator fan by suitable size GI clamps & GI nut-bolts including PVC insulated twin copper flexible cord as connected lead. (N.B.: All materials required for execution of the work and connection are to be supplied by the firm) | — | 4.00 | — | — | |
| — | — | — | 9,518.38 | ||
| Supply, digging, insertion, testing and commissioning of earth pipe made of heavy duty GI pipe of size 50 mm dia, 3 mtr. long including construction of earth pit and each pit should be provided with 2 Nos. of above pipe duly shorted by suitable length of GI flat (50 mm x 6 mm) including necessary earth connection from pit to the distribution panel with 4 SWG GI wire. Alternate layer of salt and charcoal to be spread inside the pit. Earth pit shall be completed with necessary civil work like brick chamber, PCC work & finally covered with medium duty cast iron hinged cover of size 400mm x 400mm (Make of GI pipe as per Annexure-I). N.B.: The earthing should be done as per CEE/KKK's specification. All earth value should be marked on MS plate with date by painting work. The MS flat, plate should be painted by one coat of red oxide and 2 coats of black paint before execution. The marking should be done by white paint. | for details. | Breakup | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022.pdf
ATTACHMENT
AdvancecorrectionslipsofGCC2022.pdf Advance correction slips of GCC2022
ATTACHMENT
Tenderdocuments.pdf
ATTACHMENT
scheduleofwork.pdf
ATTACHMENT
MakeAnnexure-1.pdf
ATTACHMENT
Generalspecifiation.pdf
ATTACHMENT
checklist.pdf
ATTACHMENT
Annexure-IaIbIIIIIVVA.pdf
ATTACHMENT
Annexure-IVVIVIAVIIVIII.pdf
ATTACHMENT
SharamikKalyalSpecialCondition.pdf
ATTACHMENT
AdvancecorrectionslipsofGCC2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .