Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹45.5 L+₹78,089 (1.75%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L2₹45.5 L+₹78,089 (1.75%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 4 | L3₹47.4 L+₹2.7 L (6.00%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 5 | L4₹48.2 L+₹3.5 L (7.78%)Rejected-Finance | L4 | Rejected-Finance Not lowest |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
26 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
CERTAIN ROUTINE ALLIED WORK SERVICES INCLUDING REGULAR COMPLAINTS AT MD ACCN, SCIENTIST HOSTEL AND OTHER AREA UNDER GE(I) RND KANCHANBAGH HYDERABAD
2023_MES_631446_1
8682/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹91,000
Yes
29 Jan 2024
6 Dec 2023
28 Dec 2023
6 Dec 2023
26 Dec 2023
19 Dec 2023
7 Dec 2023 - 13 Dec 2023
Amount
Repair / maintenance of internal/Building light fittings of any type like tube lights / wall bracket light fittings / ceiling lights / mirror lights/ high& Medium bay lights in its position, testing all the compenents/parts, wiring etc,identifying and replacing the defective components like, tube rod, side holders, holders, lamps etc all as directed by Engr-in-charge. Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like, capacitor, lamp holder, connector, connection wire,LED tube, Bulbs etc, replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor's Supervisor / representative will report to concerned JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report on following day before 0900hrs to the JE E/M.
(iv) The contractor has to rectify the defects and make the light fittings functional within 24 hours from the time the list of defective lights is handed over to him / his rep by the concerned JE E/M. In case the light fitting is not made functional for whatsoever reason within the specified time limit, an amount of Rs 50/- per such defective light fitting per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall engage separate team of technicians / repairer at newly various buildings of D,E &F Blocks. (v) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every light fitting and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below. (vii) The contractor should submit the copy of qulaification,Experience as Electrician and police verification certificates while sigining the site orders. (viii) The contractor is fully responsible for providing the safety standards to be maintained by the electricians while attending the electrical defects. (viii) The contractor should submit the complaint registers along with docket slip duly signed by the occupants of the building before claiming any RAR. Any complaints pending for more than the limited time Rs 100 per day per docket would be recovered.
S&F LED tube 20Watt, 6500K CCT,proffesional luminaries with luminous efficiency not less than 120Lm/watt, Single side connection with < 10% THD. Make: Havells/Polycab/Philips/Wipro
S&F in replacment indoor industrial type surface/wall mounted LED integral batten 20W, 6500K CCT, aluminium extruded body and polycarbonate diffuser, <10%THD, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete removing unserviceable fittings all as specified and directed. . Make : Havells/Polycab/Philips/Wipro
S&F in replacment LED PLL lamp Hercules 18Watt, proffesional luminaries single side connection with < 10% THD. Make: Make:Havells/ Jaquar/Crompton/Polycab/wipro
S&F in replacment indoor industrial type recess mounted LED Surface mounted for POP ceiling round downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency.15W, 6500K CCT, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable as required at site with suitable size complete removing unserviceable fittings all as specified and directed Make : Make:Havells/ Jaquar/Crompton/Polycab/wipro
S&F in replacment indoor industrial type recess mounted LED Surface mounted for Recessed Mounting ceiling round downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency.15W, 6500K CCT, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable as required at site with suitable size complete removing unserviceable fittings all as specified and directed Make: Havells/ Jaquar/Crompton/Polycab/wipro
S&F LED luminaire 600 mm x 600 mm 35/36 watt, 220V AC recessed/surface mounted type with high efficiency PMMA diffuser soft glare light with LED efficacy of 120 lm/watt electronic driver,suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size complete. Make: Havells/ Jaquar/Crompton/Polycab/wipro
Supply & Fix in replacement recess mounted LED luminaire 36W 2'x2', 5700K CCT, luminous efficacy of not less than 120lm/watt designed for metric false ceiling type or alongwith frame suitable for POP ceiling or similar mounting system with concealed or exposed 'T' sections, Glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size including making good to the disturbed portion of ceiling complete removing unserviceable fittings all specified and directed. Make : Havells/ Jaquar/Crompton/Polycab/wipro
Supply & Fix recess mounted LED luminaire 36W 4'x1' of size 1195x295x70 mm, 5700K CCT, luminous efficacy of not less than 120lm/watt designed for metric false ceiling type or alongwith frame suitable for Armstrong/ US Gypsum or similar mounting system with concealed or exposed 'T' sections, Glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size including making good to the disturbed portion of ceiling complete removing unserviceable fittings all specified and directed. Make:Havells/ Jaquar/Crompton/Polycab/wipro
S&F in replacement recess mounted LED high bay light with IP-66 protection pressure die cast body with high power SMD LEDs as light source of luminous efficacy 150lm/watt 120W, 240V, 5000K CCT, aluminium heat sink alongwith inbuilt electronic driver, wide beam angle , including hanging the fitting with required hook arrangement required at site. Make: Make:Havells/ Jaquar/Crompton/Polycab/wipro
S&F in replacement LED security light fiitting of luminous capacity 2500lumens,IP-66 protection, 5700K CCT, inbuilt electronic driver with <10%THD made up of die cast alluminium housing with high power LED as lighting source and lens embeded toughned glass cover, separate driver compartment complete fixing with GI bracket made out of 40mm bore GI pipe light grade 1.5Mtr long bend to shape and fixed to pole/wall with necessary MS clamp accessories complete all as specified and directed by Engr-in-charge. Make:Havells/ Jaquar/Crompton/Polycab/wipro
Material and Labour for sub main wiring with 2 runs of 2.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof, floors etc including one run of 2.5 Sqmm PVC copper conductor as earth continuity wire including taking down unserviceable sub main wiring including conduit all as specified and directed. Note : 2 Runs of 2.5 sqmm cable 1 run of 2.5 sqmm cable and 1 run of PVC conduit shall be measured as one unit.
All as per srl item No. 12 here-in-before but with 2 runs 4 sqmm including 1 run of 4 sqmm PVC copper conductor FRLS cable as earth continuity wire including PVC conduit not less than 25mm dia ISI marked PVC conduit. Note : 2 Runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit.
All as per srl item No. 12 here-in-before but with 2 runs 6 sqmm including 1 run of 6 sqmm PVC copper conductor FRLS cable as earth continuity wire including PVC conduit not less than 25mm dia PVC conduit. Note : 2 Runs of 6 sqmm cable 1 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit.
All as per srl item No. 12 here-in-before, but sub main wiring with 4 runs of 4sqmm with 2 run of 4 sqmm copper conductor FRLS as earth continuity wire including PVC conduit not less than 25mm dia PVC conduit. Note : 4 Runs of 4 sqmm cable 2 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit.
Material and Labour for sub main wiring with 4 runs of 6 Sqmm single core ISI marked PVC insulated unsheathed cable 1100 Volts grade multistranded copper conductor cable drawn through in and including surface/concealed rigid PVC conduit medium grade of size not less than 25mm dia and conduit accessories such as bends, tees, junction boxes type on walls, roof, floors etc.. including providing 2 runs of 6 Sqmm PVC insulated unsheathed multistranded FRLS copper conductor cable as earth continuity conductor and connecting to earth dolly wire including taking down unserviceable sub main wiring and conduit all as specified and directed. Note :- 4 Runs of 6 sqmm cable 2 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit. Make for Item No 12 to 16 : For Copper wire : Finolex/Nicco/Havells/Gloster/KEI For PVC conduit : Sudhakar/Polyplast/Supreme/GM Make of Gang Boxes: GM/Havells/Legrand
Material and labour for point wiring complete with ISI marked 1.5 Sqmm PVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, in PVC casing & caping type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including PVC gang boxes as required at site surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:-
One light/ fan point controlled by one, one way switch
One socket outlet 5 pin 5 amps controlled by one switch on same board.
One socket outlet 5 pins 5 amps controlled by one switch on independent board.
All as per item No. 17 here-in-before but wiring with 4.00 Sqmm for 15 Amps switch socket combination on independent board/two pin earth plug and socket including providing 4 Sqmm PVC insulated multi stranded copper earth continuity conductor and connected to common earth dolly. Make For Copper wire : Finolex/Havells/Gloster/KEI. For PVC conduit :Sudhakar/Polyplast/ Avon plast.
Material and labour for point wiring complete with ISI marked 1.5 Sqmm PVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:-
One light/ fan point controlled by one, one way switch
One light point controlled by one, two way switch
One 5 Amps socket point on independent board.
One 5 Amps socket point on same board with other switches
All as per item No. 18 here-in-before but wiring with 2.5 Sqmm FRLS for 15 Amps switch socket combination on independent board/two pin earth plug and socket including providing 2.5 Sqmm PVC insulated multi stranded FRLS copper earth continuity conductor and connected to common earth dolly.
All as per item No. 18 here-in-before but wiring with 4.00 Sqmm FRLS for 15 Amps switch socket combination on independent board/two pin earth plug and socket including providing 4 Sqmm PVC insulated multi stranded FRLS copper earth continuity conductor and connected to common earth dolly.
S&F in repairs PVC / polycarbonate Angle/Batten type lamp holders retrofit type. Make: Anchor/GM/Cona
S&F in replacement for white cover plate with frame 8 module.
S&F in replacement for white cover plate with frame 6 module.
S&F in replacement for white cover plate with frame 4 module.
S&F in replacement for white cover plate with frame 3 module.
S&F in replacement for Modular socket 6A 2/3 Pin 2 module.
S&F in replacement for Modular socket 16A 2/3 Pin 2 Module.
S&F in replacement for modular switch 1 way 6A 1 module.
S&F in replacement for modular switch 1 way 16A 1 module.
S&F in replacement of modular fan regulator 120W,240V, 2module, suitable for ceiling fan of 1200/1400mm sweep.
S&F in replacement of modular fan regulator 120W,240V, 1 module, suitable for ceiling fan of 1200/1400mm sweep.
S&F in replacement for modular switch 2 way 6A 1 module. Make of item No 19 to 30: L&T/Schneider/Crabtree
S & F in replacement of switch piano flush type 5 Amps SP one way all as specified. Make:-Anchor/Cona/GM
S & F in replacement of switch piano flush type 15 Amps SP one way all as specified. Make:-Anchor/Cona/GM
S&F in replacement of fan regulator 120W,240V, switch type suitable for ceiling fan of 1200/1400mm sweep.
S&F in replacement of fan regulator 120W,240V, socket type suitable for ceiling fan of 1200/1400mm sweep.
S & F in replacement of socket combination 5 Amps flush mounted 3/5 pin multi purpose all as specified. Make:-Anchor/Cona/GM
S & F in replacement of socket combination 5/15 Amps flush mounted 3/5 pin multi purpose all as specified. Make:-Anchor/Cona/GM
Supply and fix in replacement MCB DB 08 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed . Make: Legrand/ Schneider/L&T/C&S
Supply and fix in replacement MCB DB 04 way SPN (single door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed . Make: Legrand/ Schneider/L&T/C&S/Havells
Supply and fix in replacement MCB DB 12 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells
Supply and fix in replacement VTPN DB 04 way (double door) sheet metal enclosure factory made suitable for MCCB 415 volts incomer and MCBs as outgoing with 250 amp rated copper busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits including provision of incoming MCCB & outgoing SP/TP MCBs as outgoing complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells
Supply and fix in replacement MCB TPN DB 04 way (double door) sheet metal enclosure factory made suitable for MCB TPN incomer and MCBs as outgoing with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells
Supply and fix in replacement VTPN DB 08 way (double door) sheet metal enclosure factory made suitable for MCCB 415 volts incomer and MCBs as outgoing with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits including provision of incoming MCCB & outgoing SP/TP MCBs as outgoing complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells
Supply and fix in replacement VTPN DB 12 way (double door) sheet metal enclosure factory made suitable for MCCB 415 volts incomer and MCBs as outgoing with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits including provision of incoming MCCB & outgoing SP/TP MCBs as outgoing complete as reqd at site as directed. Make : Legrand/L&T/Schneider/Havells
Supply and fix inreplacement of MCB single pole 6-32 Amps working on 240 volts, 50 HZ AC, 10 KA 'C' curve all as specified and directed. Make: Legrand/C&S/L&T
S&F in replacement of MCB SPN 32-40 Amps working on 240 volts, 50 HZ AC, 10 KA 'C' curve all as specified and directed. Make: Legrand/C&S/L&T/Havells
S&F in replacement of MCB TP 40 Amps working on 415 volts, 50 HZ AC, 10 KA ,'C' curve all as specified and directed. Make: Legrand/C&S/L&T/Havells
S&F in replacement of MCB TPN 63 Amps working on 415 volts, 50 HZ AC, 10 KA ,'C' curve all as specified and directed. Make: Legrand/C&S/L&T/Havells
Supply & Fix in replacement PVC insulated round cable 3 core stranded copper conductor 2.5 sqmm as in connection cord. Make : Polycab / Havells / Plaza
Supply and fix in replacement metal clad plug top 3 pin, 20 amps, ISI marked heavy duty for AC connection cord. Make:Legrand/Havells/Scheinder
Supplying and fixing 1100 volts grade cable PVC insulated copper strandard conductor cable of size 1.5 sqmm flat or circular complete all as specified and directed. Make : Havells/Finolex/Plaza
All as per item No. 50 above but of size 2.5 sqmm
All as per item No. 50 above but of size 4.0 sqmm
All as per item No. 50 above but of size 6.0 sqmm
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed by Engr-in-Charge.
M&L for testing of old earthing using calibrated earth tester and submitting result to Engr-in-Charge. Earthing which showing much more result as specified as directed and disconneted should replaced with new earthing items are considered as below :- Note :- (i) Watering of earthing with 2 bucket 30 ltrs water mixed with salt (Total 5 Kg) shall be carried out one day before the testing and the cost of the same shall deemed to included in quoted rate.
S&F/lay GI earth wire 4 mm dia on walls/floor as earth continuity conductor connected to DBs/ panels etc.
Supply and Fix GI tubing 15mm dia light grade for protection of GI earth wire complete all as specified and directed.
S&F in replacmenet MCCB with rating of 100Amps,415Volts 4pole with 16 kA breaking capacity,thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be 100% of ultimate breaking capcity(Icu) with inbuilt Display for Current Metering with accuracy of class 1. MCCB should be with suitable spreaders and phase barriers for each terminals with all accessories all as specified and directed. Make : Legrand/L&T/Schneider/Havells
All As per item No :58 above but 160Amps, 4 pole, 36 KA. Make : Legrand/L&T/Schneider/Havells
S&F in replacmenet MCCB with rating of 63Amps,415Volts 4pole with 16 kA breaking capacity,thermal magnetic adjustable of overload & fixed short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be 100% of ultimate breaking capcity(Icu) . MCCB should be with suitable spreaders and phase barriers for each terminals with all accessories all as specified and directed. Make : Legrand/L&T/Schneider/Havells
All As per item No :60 above but 125Amps, 4 pole, 16 KA. Make : Legrand/L&T/Schneider/Havells
Supply only capacitor of 2.5 mfd for ceiling fan/exhaust fan. Make: Epcos/Havells/Tibcon
Supply only capacitor of 4 mfd for air circulator/exhaust fan. Make: Epcos/Havells/ Tibcon
Supply only aluminium fan blade for exhuast fan of any sweep/make as per the sample given by the Engr-in-charge.
Supply only carbon steel shaft as suitable for ceiling fan/Exhuast fan/ Pedestal Fan/ Air Circulator fans matching to the existing size.
Material and labour for fixing metal pulg and socket DB for AC connecton (AC box) complete with all accessories etc all as directed. Make: Havells/Legrand/Polycab/Wipro
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC).
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. Note for Sl No 67-69: Old Ceiling fan,Exhaust Fan& Geyser to be deposited at MES store Yard or fixed at other location as directed by Engr-inCharge.
S&F in repairs bus bar chambers mounted on wall/pole including nuts ,bolts & clamps of bus bar capacity 200 A, 6 way .complete all as specified & directed. Make: Havells cat part no IHBC20006 or equivalent in Legrand/Siemens
S&F in repairs MCCB 250 Amps, 4 pole, 25 KA/35KA, 415 Volts, 50 HZ, Icu=100%Ics thermal magnetc with adjustable overcurrent & short current settings including necessary fixing arrangement for fixing of MCCB to the existing panel, connecting cable connections including taking down old unserviceable MCCB complete all as directed. Make: Havells Cat part no IHAE2OB40250 or equivalent in Legrand/C&S
S&F in repairs MCCB 630 Amps, 4 pole, 36KA, 415 Volts, 50 HZ ,Icu=100%Ics thermal magnetic with adjustable overcurrent & short current settings including necessary fixing arrangement for fixing of MCCB to the existing panel, connecting cable connections including taking down old unserviceable MCCB complete all as directed. Make: Havells Cat part no IHLLSEB40630 or equivalent in Legrand/C&S NOTE:For Sl no 71 & 72 rates quoted to be included spreader terminals as per site requirement.
S&F in repairs PVC connection with metal fabricated outer connection for geyser, of best quality 15mm dia, 600mm long with union, brass nuts and washers for hot water pipe for outlet connection complete all as directed. Make : KOHINOOR/ MAHAVIR/ PRAYAG (SYMET)
S&F in replacment indoor industrial type surface/wall mounted LED integral batten 10W, 6500K CCT, aluminium extruded body and polycarbonate diffuser, <10%THD, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete removing unserviceable fittings all as specified and directed. . Make : Havells/Polycab/Philips/Wipro
S & F in replacement of socket combination 5/15 Amps flush mounted 3/5 pin multi purpose gangbox type all as specified. Make:-Anchor/Cona/GM
SRI SAI ENTERPRISES
M.R.ENTERPRISES
ELEVATORS MAINTENANCE ENGINEER WORKS
Venkat Sai Enterprises
hari enterprises
MOHAMMED GHOUSE
Anjana corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .