| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹11.4 L+₹1.4 L (13.6%)Rejected-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹12.4 L+₹2.3 L (23.3%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹10.8 L
EMD Value
₹21,600
Closing Date
26 Aug 2021, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD Bowenpally Post Secunderabad 500011
PROVISION OF TROLLEY MOUNTED TRANSFORMER AT CAW AREA UNDER GE AF HAKIMPET
2021_MES_453937_2
84656/02/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Hakimpet
As Per NIT
9 documents required · 9 mandatory
₹500
GE AF HAKIMPET
₹21,600
Yes
30 Aug 2021
29 Jul 2021
28 Aug 2021
29 Jul 2021
26 Aug 2021
12 Aug 2021
29 Jul 2021 - 9 Aug 2021
Amount
Supply , installed, Testing and commissioning Transformer step down , Copper wounded, Outdoor Type complete with standard fittings HT 11 KV / 433 volts (at no load) 3 phase 4 wire, 50 Hz, 250 KVA capacity core type double copper wound, oil immersed. naturally cooled,. Oil naturally Air natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with victor group DYn-11 with natural brought out on secondry side (LV side) and having tapping at +- 2.5% & +- 5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temp rise should not exceed 45 degree celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after contineous full load run on an ambient temperature of 40 degree Celsies. The Transformer shall be IS - 1180 marked complete all as specified and as directed and shall comprises of the following :-
(a) Three Nos porceian bushing suitable for 11 KV on HV side complete with copper rods, nuts and washers etc.
(b) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers with cable glands.
(c ) Oil conservator with filter type drain valve and oil level gauge.
(d) De- hydrating breather with first type fill of dehydrating agent (Silica Gel).
(e) Explosive vent, thermometer pocket on tank cover .Oil level gauge , Oil dgain filter valve, Lifting lugs, Oil filling hole with cap , plug with connection plate complete. Air release valve plug and four nos plain solid cast steel detachable rollers.
(f) One No 100 mm dia dial type thermometer vapour pressure type , having range 0-120 Degree Celsius with metal guard having mazimum perimeter temperature reading indicator with re- setting devices.
(g) Two earthing terminal on tank cover to facilitate fixing of 32 mm x 6 mm GI iron earth strip for earthing of body.
(h) Rating plate and terminal marking plate
(j) Extra bushing for neutral, out side the cable box for providing independent set of earthing for neutral
(k) Frist filling of new and unsued transformer oil, IS- 335 marked (Make - Savita / Power Link) filtered and tested complete.
Supply laying, jointing and testing cable HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sq. mm 3.0 core complete all as specified and as directed.
Supply and fixing Cable jointing kit for 11KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3.0 core XLPE armoured aluminium conductor cable of 95 sqmm to 185 sqmm complete all as specified and as directed.
Supply & Laying in trenches or passing through pipe / fixed to pole / wall LT XPLE insulated armoured heavy duty electric cable with alluminium conductor , 1100 volts grade , cross sectional area 120 sqmm X 3.5 core complete all as specified and as directed.
Material and labour for Transformer trolly , totally enclosed suitable for carry the transformer of capacity 315 KVA outdoor type and the trolly having following technical specifications:-
(a) Dimention of platform - 2100mm X 1500mm (+ or -10 mm)
(b) Height - 1500 mm (+ or -10 mm)
(c ) Chassis (Base frame) - MS Channel 75 X 38 mm & 100 X 50 mm
(d) Platfrom (Floor) - MS Plate Approx 5 mm Thick
(e) Trolly Side (Cage Frame) - MS Sq pipe 50 X 50 mm 2 mm thick (+-2 mm ) & covered by weided Mesh of size 75 mm X 30 mm
(f) Front Rear & side door - (3 Doors ) Fabricated with MS Angle iron 35 X 35 X 5 mm covred with weided mesh with heavy hinges and locking arrangement
(g) Support for DO Fuse & insulators MS channels 75 X 38 mm (+-2 mm) height 1720 mm & Distance phase to phase 500 mm distance
(h) Axel - 2 Axel size 50 mm sq and length 1500 mm front without brake down rear with back drum
(j) Rims - Rim 4 in Number
(k) Tyres and tubes - 4 in Nos inflatable of size 600 X16
(l) Suspension - Leaf spring suspension provided on all four wheels with hangers and U bolts suitable for 2.5 ton gross weight.
(l) Suspension - Leaf spring suspension provided on all four wheels with hangers and U bolts suitable for 2.5 ton gross weight.
(n) Draw Bar - MS Channel 75 X 38 mm (+-2mm)
(o) Toeing Hook - MS Round 30 mm
(p) Loading capacity - Suitable to carry 315 KVA Transformer
(q) Paint - Grey Enamel Paint of approved shades
Universal refrigeration and Engineering Company
M/S AMRIT DAS MAHAPATRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .