| Sl No | Description | Qty | Unit | Sumit Enterprises L3 | Shree Ayyappa Engineering L2 | Saviour Security Systems L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation Testing & Commissioning of microprocessor based Networkable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have expandable capacity from 2 loops to 8 loops. The Panel must have Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The Panel must also have the capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connected expansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54-4. The Panel shall have configurable via USB port to PC or memory stick. The Panel shall have dedicated RS232 serial port for optional printer. Approved by LPCB, complete all as specified.
Model- Latitude 2LKS Make: Hochiki or equilant from Bosch/ Seimens | 2 | Each | 2,96,888 ₹5,93,776 | 2,55,000 ₹5,10,000 | 2,50,000 ₹5,00,000 Lowest |
| 1.01Note No. 1 : Contractor must ensure that the proposed fire alarm system must be compatible with the existing fire alarm system installed at site, which is of Bosch Avenar/Honeywell/ Hochiki/Siemens technology. Contractor must ensure that the fire alarm system that he is going to incorporate with the existing Bosch Avenar/Honey Well/ Hochiki/Siemens technology. As each manufacture uses different commmunication protocols, devices of any other make will not be compatible with the existing installtion. Therefore, the Fire alarm control panel and all associated accessories required to centralize the fire alarm system connection must be of Bosch Avenar/Honeywell/ Hochiki/Siemens technology compatible only. While executing centralized fire alarm work all the existing and the proposed panel are to be interconnected to establish communication protocols, integrated and synchronized with the existing fire alarm system for smooth working (i.e Bosch Avenar/Honeywell/ Hochiki/Siemens technology) without modications to the MCP, smoke detector, hooter, control relay, fire panel and all other existing accessories. If any other system is to be installed/integrated the cost of changing the existing fire alarm system and other auxillary hardware is deemed to be included in the quoted be. Note No. 02 : Contractor shall submit (i) Drawing/layout for integration of fire alarm (ii) OEM manuals (iii) Test certificate. | ||||||
| 2.00 | Supply, Installation Testing & Commssioning of Analogue Addressable Multi-Sensor which is fully compatible with Analogue Addressable Protocol, having removable high performance chamber with Twin fire LED's allow 360 degree veiwing, User selectable sensitivity modes 1% to 4.5% obs/m, Incorporate Optical and dual Heat elements, lock mechanism (sensor to base), Electronically addressed, Pulsing/non- pulsing controlled from panel. complete all as specified and directed. Approved by LPCB & VdS.Makes: (Hochiki/Bosch/Seimens) | 190 | Each | 4,366 ₹8,29,540 | 2,865 ₹5,44,350 Lowest | 2,865 ₹5,44,350 Lowest |
| 3.00 | Supply, Installation Testing & Commissioning of Intrinsically Safe Conventional Rate of Rise Heat detector features, Twin LEDs allow 360 degree viewing, Electronics free mounting base, remote indicator output, ATEX classification II 1G EEx ia IIC T5 Tamb = 55 degree, Suitable for installation in areas at Category 1 (inc all lower categories). ATEX Approved Make: Hochiki/Bosch/Seimens | 2 | Each | 10,256 ₹20,512 | 8,260 ₹16,520 Lowest | 8,260 ₹16,520 Lowest |
| 4.00 | Supply, Installation Testing & Commissioning of Analogue Addressable Intrinsically Safe Dual Monitor 4 module with integral Short Circuit Isolator which fully monitored for short/open circuit, Addressing via DIL switches, Approved by LPCB. Make: Hochiki/ Bosch/Seimens | 5 | Each | 14,498 ₹72,490 | 10,320 ₹51,600 Lowest | 10,320 ₹51,600 Lowest |
| 5.00 | Supply, Installation, Testing and Commissioning of Optical Beam Smoke Detector. The detector shall have 5-100 m range, Automatic compensation, Maximum coverage 1500m2, Automatic Signal strength 5 adjustment, Emitter unit can be powered directly from zone (or loop), Features a Latching or Non- Latching fault relay, Full line continuity options, Approved by LPCB & VdS. Model- SPC-ET Make: Hochiki/Bosch/Seimens | 4 | Each | 72,039 ₹2,88,156 | 46,545 ₹1,86,180 Lowest | 46,545 ₹1,86,180 Lowest |
| 6.00 | Supply, Installation Testing & Commissioning of Analogue Addressable Manual Call Point with Integral Short Circuit Isolator, Analogue Addressable Protocol having,Bi-coloured status LED (red for alarm, amber for (short-circuit), Non-frangible element fitted as standard (conforms to EN54), pulsing/non-pulsing can selectable via panel, Electronically addressed, complete all as specified and directed. Approved by LPCB. Makes: (Hochiki/Bosch/Seimens) | 11 | Each | 4,800 ₹52,800 | 3,520 ₹38,720 Lowest | 3,520 ₹38,720 Lowest |
| 7.00 | Supply, Installation, testing and commissioning of Intelligent loop powered wall Sounder with Flasher Beacon which provide a range of tones and volumes with a maximum output of up to 102dB(A) (±2dB(A)) with low current consumption, 51 user selectable tones (all tones EN54-3 compatible). complete all as specified and directed. Approved by LPCB & VdS. Makes: (Hochiki/Bosch/Seimens) | 11 | Each | 8,295 ₹91,245 | 6,090 ₹66,990 Lowest | 6,090 ₹66,990 Lowest |
| 8.00 | Supply, Installation, Testing and commissioning base Fault Isolator fully monitored for short/Open circuit compatible with Analogue Addressable Protocol, Electronically addressed, approved by LPCB, unit incorparates an amber LED to show when it is islating a section of a Loop complete all as specified and directed.
Makes: (Hochiki/Bosch/Sermens) | 6 | Each | 2,400 ₹14,400 | 1,885 ₹11,310 Lowest | 1,885 ₹11,310 Lowest |
| 9.00 | Supply, Installation Testing & Commissioning of Analogue Addressable Dual Relay Controller with integral 9 Short Circuit Isolator which allow 2 independently controlled change over relays, Relay Contact Rated at 30 V DC at 1 Amp. having auxiliary monitored input, followed by Analogue Addressable Protocol, Addressing via DIL switches, Approved by LPCB. Makes: (Hochiki/Bosch/Seimens) | 4 | Each | 8,732 ₹34,928 | 7,670 ₹30,680 Lowest | 7,670 ₹30,680 Lowest |
Tender Value
₹43.7 L
EMD Value
₹87,400
Closing Date
2 Feb 2026, 6:00 pmClosed
CWE AF NAGPUR
HQ CWE AF NAGPUR VAYUSENA NAGAR, NAGPUR 440007 MILITARY ENGINEER SERVICES
PROVN OF CENTRALISED FIRE ALARM SYSTEM AT FIRE SECTION OF 11 BRD AND FIRE ALARM AND DETECTION SYSTEM AT AFLE (ND) UNDER GE (AF) OJHAR
2026_MES_748106_1
80737/E8
Open Tender
Civil Works
Item Rate
GE AF OJHAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF OJHAR
₹87,400
Yes
9 Mar 2026
12 Jan 2026
4 Feb 2026
12 Jan 2026
2 Feb 2026
26 Jan 2026
Supply, Installation Testing & Commissioning of microprocessor based Networkable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have expandable capacity from 2 loops to 8 loops. The Panel must have Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The Panel must also have the capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connected expansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54-4. The Panel shall have configurable via USB port to PC or memory stick. The Panel shall have dedicated RS232 serial port for optional printer. Approved by LPCB. Model- Latitude 2LKS Make: Hochiki or equilant from Bosch/ Seimens
Supply, Installation Testing & Commissioning of Intrinsically Safe Conventional Rate of Rise Heat detector features, Twin LEDs allow 360 degree viewing, Electronics free mounting base, remote indicator output, ATEX classification II 1G EEx ia IIC T5 Tamb = 55 degree, Suitable for installation in areas at Category 1 (inc all lower categories). ATEX Approved Make: Hochiki/Bosch/Seimens
Supply, Installation Testing & Commissioning of Analogue Addressable Intrinsically Safe Dual Monitor 4 module with integral Short Circuit Isolator which fully monitored for short/open circuit, Addressing via DIL switches, Approved by LPCB. Make: Hochiki/ Bosch/Seimens
Supply, Installation, Testing and Commissioning of Optical Beam Smoke Detector. The detector shall have 5-100 m range, Automatic compensation, Maximum coverage 1500m2, Automatic Signal strength 5 adjustment, Emitter unit can be powered directly from zone (or loop), Features a Latching or Non- Latching fault relay, Full line continuity options, Approved by LPCB & VdS. Model- SPC-ET Make: Hochiki/Bosch/Seimens
Supply, Installation, Testing and commissioning base Fault Isolator fully monitored for short/Open circuit compatible with Analogue Addressable Protocol, Electronically addressed, approved by LPCB, unit incorparates an amber LED to show when it is islating a section of a Loop complete all as specified and directed. Makes: (Hochiki/Bosch/Sermens)
Supply, Installation Testing & Commissioning of Analogue Addressable Dual Relay Controller with integral 9 Short Circuit Isolator which allow 2 independently controlled change over relays, Relay Contact Rated at 30 V DC at 1 Amp. having auxiliary monitored input, followed by Analogue Addressable Protocol, Addressing via DIL switches, Approved by LPCB. Makes: (Hochiki/Bosch/Seimens)
Supply, Installation, Testing and commissioning of Electric Siren 02KM range with required MCB, Relays etc, complete all as specified and directed. Make: Kheraj
Supply, Installation Testing & Commissioning of 12 V 12AH Batterries, complete all as specified and directed. Make: EXIDE/Amaron
Material and labour for supply and fix armored fire cable copper conductor of size 1.5 sqmm two core 12 FRLS in Red colour fixed on wall/roof with GI saddle complete all as specifed and directed at site. Make: Havells/Polycab/Safetap
Supply, Install, Testing and commissioning of Sine wave inverter 1176 W with 150 AH Tubular Batterry, complete all as specified and directed.
Supply, Installation Testing & Commissioning of Analogue Addressable Intrinsically Monitor module with integral Short Circuit Isolator which fully monitored for short/open circuit, Addressing via DIL switches, Approved by LPCB. Make: Hochiki/ Bosch/Seimens
Supply, Installation Testing & Commissioning of Analogue Addressable Control module with integral Short Circuit Isolator which fully monitored for short/open circuit, Addressing via DIL switches cnnect with existing Hochiki Lattitude control panel including necessary programming of the system, complete all as specified and directed.
Supply, Installation Testing & Commissioning of Analogue Addressable Control module with integral Short Circuit Isolator which fully monitored for short/open circuit, Addressing via DIL switches cnnect with existing Bosch FPA5000 control panel including necessary programming of the system, complete all as specified and directed.
Supply, Installation Testing & Commissioning of Analogue Addressable Control module with integral Short Circuit Isolator which fully monitored for short/open circuit, Addressing via switches cnnect with existing Seimens control panel including necessary programming of the system, complete all as specified and directed.
Supply, Installation Testing & Commissioning of Analogue Addressable Control module with integral Short Circuit Isolator which fully monitored for short/open circuit, Addressing via switches cnnect with existing Honeywell control panel including necessary programming of the system, complete all as specified and directed.
Supply, Installation, Testing and Commissioning of Signal Booster unit with batterry charger and back up batterries, complete all as specified and directed.
Supply , Installation Testing & Commissioning of 12 V 12AH Batterries, complete all as specified and directed.
Supply,Installation,Testing and commissioning of 1.5 mm X 4 Core FRLS multistranded copper armoured Cable with all fixing materials, complete all as specified and directed. Make:Havells/Polycab/Safetap
Supply,Installation,Testing and Commissioning of Water proof junction Boxes Size 300X200X105mm with connectors, complete all as specified and directed.
Supply,Installation,Testing and Commissioning of Universal Cellular Communicator ,consisting CID to voice messages function and CiD to SMS message function, Stand alone and KIT versions ,Integrated antenna,Rtemote programming by BOSS,direct communication with CMS,06 programmable terminals(input/out put), USB port for programming,Connector for optional external antennas,optional li-Ion batterry for 06 hours autonomy complete approved by EN50136. Make:BENTEL or equivalent.
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil all as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm all as directed.
Removing of surplus soil not exceeding 50 meter and depositing where directed at a level not exc 1.50 mtr above the starting point all as directed.
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report, complete all as specified and directed. Make :- Dura- line/Gemini/Rex. of size 38 mm inner dia
Material and labour for Boring of holes under Road, Pavements, Hard Standing by trench less technology at a depth 0.6 Mtr from top surface including supply & fix HDPE pipe of 80 mm dia suitable for 0.4 MPA working pressure complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
BOQ_837783.xls
BOQ • 0.41 MB
TENDERPAGE80737MERGED.pdf
Tender Documents • 1.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .