| 1 | L1₹36.9 LAccepted-AOC 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹38.7 L+₹1.3 L (3.50%)Rejected-Finance 93 61 AGARWAL FARM MANSAROVER JAIPUR 302020 | JAIPUR | JAIPUR | RAJASTHAN | 302020 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹39.4 L+₹2.1 L (5.55%)Rejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹43.3 L+₹6.0 L (16.0%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹44.9 L+₹7.5 L (20.2%)Rejected-Finance 499 A VIDHYUT NAGAR A AJMER ROAD JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
30 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JAIPUR
HQ CWE JAIPUR
UPGRADATION OF HT ELECTRIC SYSTEM IN ZONE III AREA UNDER (GE SOUTH) AT JAIPUR MIL STN
2020_MES_389036_1
CWE/82017/JPR(S)/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
JAIPUR
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (SOUTH) JAIPUR
₹98,000
Yes
18 Dec 2020
22 Oct 2020
2 Dec 2020
22 Oct 2020
30 Nov 2020
5 Nov 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables erection of poles / struts/stays etc not exceeding 10 Sqm on plan, not exceeding 1.5 metre in depth and getting out in any type of soil. .etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil. .etc complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.50metre above the starting point. .etc complete all as specified and directed.
Supplying and laying un-reinforced precast cable covers class HV, type I, flat, size 300mm x 180mm x 40mm.etc complete all as specified and directed.
M & L Sand cushioning to XLPE underground cable with screened and washed sand and punning to provide a required cover.etc complete all as specified and directed.
M&L for PCC (1:3:6) type C2 using 40 mm grade stone aggregate in base & foundation of stay assembly /struts/poles including necessary form work etc complete all as specified and directed.
M&L for PCC (1:3:6) type C1 using 20 mm grade stone aggregate in pedestal of poles including necessary form work etc fair finished the exposed surfaces using extra cement etc complete all as specified and directed.
Supply, laying and commissioning XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade IS-7098 marked, suitable for HT 11 KV (E) System laid in trenches/ ducts/ encased in GI pipe/ fixed to poles including jointing & testing complete all as specified and directed of cross sectional area 185 Sqmm, 3 core cable (Earthed).
M&L for cable end termination, jointing kit, HT 11 KV (Earthed) grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade of size 185 Sq.mm x 3 core etc complete all as specified and directed.
M&L for cable end termination, jointing kit, HT 11 KV grade, heat shrinkable, indoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade of size 185 Sq.mm x 3 core etc complete all as specified and directed.
M&L for cable, jointing kit, HT 11 KV grade, heat shrinkable, straight through type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade of size 185 Sq.mm x 3 core etc complete all as specified and directed.
M&L for mild steel work such as angle iron fencing post struts and flat iron fillets etc of grade Fe-310-0, including drilling holes, punching, splitting ends to secure chain link fencing or fixing of barbed wire to posts including all necessary cutting, welding drilling, bolting or riveting etc and including bands strap support for chain link, steel screw as required, flat iron strip fixed to secure the fencing on posts complete and rolled mild steel Framed work as in Gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails & guides) & hanging; also fastening & fixing complete GDE Fe 410-0 or Fe 310-0 including taking down old fencing etc. complete all as specified and directed
S&F of chain link fencing of size 150mm x 100mm, 4mm dia galvanised steel wire including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire etc. complete all as specified and directed .
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. NOTES :- (i) The concrete pit shall be PCC (1: 3:6), 20mm thick precast cover slab of RCC (1:2:4) type B1 using 20mm graded stone aggregate with suitable mild steel handle in lieu of cast iron cover shown in electrical plate No-03 of MES SSR Part-I. Reinforcement in RCC cover shall be 8 mm dia TMT steel bar @ 150mm c/c both ways. (ii) Item includes the cost of 7.5 mtr GI pipe for protection of earth lead/strip. Any variation in length shall be measured and paid through relevant item of schedule 'A'. (iii) Item includes the cost of 7.5 mtr earth lead strip. Any varriation in length shall be measured and paid through relevent item of schedule 'A'. iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to packed thickness of 150mm on all sides as specified.
M&L earthing complete as per electrical plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 600 mmx600mmx6mm, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. NOTE:- (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.00 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire. (iii) Quoted shall include cost of 7.5 metre earth lead wire. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
S&F and laying galvanised steel tubing light grade 100mm bore (ISI marked) for protection of underground cable on poles / walls under road crossing etc including dismantling & taking down existing pipe etc complete all as specified and directed.
M&L for boring of existing road/path for laying of GI pipe protection for UG cable including making good disturbed area/surface etc complete all as specified and directed.
M&L pre-stressed cement concrete poles, 11 metre long with minimum cross section 152 mm x 152 mm at top and minimum cross section 152 mm x 260 mm at bottom, class-9, conforming to IS-1678 etc complete all as specified and directed.
Supply, installing, testing and commissioning of Air break, gang operated, triple pole switch, outdoor, horizontal / vertical mounting type (ISI marked), mechanically operated, mounted on insulators and frame work with operating mechanism worked from ground level with locking arrangements including Godrej pattern 65mm pad locks with two keys, complete suitable for HT 11 KV, 50 Hz AC supply including necessary electric connections complete including taking down old U/S all as specified and directed by Engineer-in-Charge of following rating :-
(a) 400 Amp rating complete with fuse carriers and HT fuse elements.
S&F of lightening arrestor expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable for 11000 volts etc complete all as specified and directed.
Dismantling of old existing ACSR or AAC conductors of any size and any type etc complete all as specified and directed.
Dismantling of cross arms, bracing, support, clamps, nut & bolt of mild steel channel or angle sections etc complete all as specified and directed.
Dismantling of old existing insulators of any shape and any type etc complete all as specified and directed.
Dismantling of old existing stay assembly of any size and any type etc complete all as specified and directed.
Dismantling of prestressed cement concrete poles complete of any size including PCC foundation and necessary excavation and earth work and making good to disturbed surfaces etc complete all as specified and directed.
Supply, installation, testing and commissioning of 11 KV outdoor (IP 54) type extensible ring main unit (RMU) floor mounted, with internal copper bus bars and Metering Modules. All live parts, bus pars, VCBs connections of RMU should be enclosed in Stainless Steel tank of 2+/-0.5 mm thick sealed for life having IP67 degree of protection filed with gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200.RMU shall have solid earthing system, RMU should complete with all accessories, fittings & fixtures as per with IEC standards 62271-200. Internal arc type tested for 25KA for 3 Sec, RMU test reports shall be type tested. OEM shall submit type etc complete all as specified and directed.
(a) Rated voltage should be – 12 KV.
(b) Rated power frequency voltage – 28 KV.
(c) Rated lightning impulse withstand voltage – 75 KV.
(d) Rated current for VCB feeder – 630A.
(e) Rated short time current withstand – 25 KA for 3 Sec.
(f) Rated short time making current – 50 KA.
(g) Nominal operating gas pressure – 1.2 Bar abs.
(h) Ambient Temperature – (0 deg C to + 55 deg C).
(j) Rated internal are rating – 21 KA for 1 Sec IAC-AFLR in tank and cable box both.
(k) RMU shall be fully motorised and manual operation both.
(l) RMU shall be provided with battery and battery charger rated for 24 V DC for motorisation.
(m) Cable boxes suitable for termination of upto 1x3Cx185 Sq.mm XLPE cable with touch proof cable termination kit (185 Sq.mm, 3 core, 11KV) suitable clamping plate and copper earthing bar for grounding the cable braid.
(n) “Live Cable” LED indicators through capacitor voltage dividers mounted on the bushings.
(o) RMU cable box shall be only front accessible type to have easy access to protection and metering CTs.
(p) RMU shall have suitable metering compartment.
(q) RMU metering compartment shall be provided with line connected potential transformer rated for ratio 11V3/110v3, 25VA for metering purpose having class 0.5 accuracy for all incoming and outgoing feeders.
(r) RMU shall be provided with metering CTs rated for 200-100/1 amps class – 0.5 accuracy, 2.5 VA burden for all circuit breakers and load break switches.
(s) RMU shall be provided with protection CTs rated for 200-100/1 amps class – 10P10 accuracy, 2.5 VA burden for all circuit breakers.
(t) All feeder of RMU shall be provided with multifunction meters with accuracy class 0.5 having complete range of measurement including maximum demand shall have serial port for communication on MODBUS protocol. The RMU manufacturer shall use meters of reputed make.
(u) All circuit breaker feeders shall be self powered and provided with over current & earth fault protection for transformer and shall have serial port for communication on modbus protocol. The RMU manufacturer shall use relay of reputed make.
(v) RMU shall be provide with fault passage indicators on every feeder having LCD display and auto reset facility and one NO/NC auxiliary contact for showing status of SCADA.
(x) Electrical as well as mechanical interlocking arrangement shall be provide for safety and operations.
Note :- The quoted rates include PCC footing with brick masonry platform 1.2 m wide on all four sides of RMU duly plastered including approach stairs. RMU shall be installed at a height of 75 cm above ground level including making arrangement for cable entry on rear side.
S&F for HT cables route indicator cast iron of suitable size along HT cable trench including painting and grouted in ground in PCC etc complete all as specified and directed by Engr-in charge.
Schedule of Credit
M/S Anil Enterprises
M/s SCHOLASTIC ENTERPRISES
SHREE BHAGWATI ENTERPRISES
DIVYA ASSOCIATES
Ms Kamal Kant Agarwal
krishna Associate
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .