| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-Finance A 160 2ND FLOOR KRISHNA BHAWAN VIKAS MARG SHAKARPUR DELHI 110092 | DELHI | DELHI | DELHI | 110092 | L1 | Accepted-Finance Accepted | |
| 2 | L2₹21.5 L+₹2.5 L (13.2%)Accepted-Finance | L2 | Accepted-Finance Accepted | |
| 3 | L3₹21.9 L+₹2.9 L (15.5%)Accepted-Finance SHOP NO 135 KHANNA MARKET SOUTH DELHI 110003 | NEW DELHI | DELHI | 110003 | L3 | Accepted-Finance Accepted | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Completion certificate has been expired |
Tender Value
₹22.9 L
EMD Value
₹45,779
Closing Date
5 Jun 2026, 3:00 pmClosed
Executive Engineer(E)
Judiciary Electrical Division-I, PWD, Yamuna Western Bank, Lok Nayak Setu, New Delhi-110002
Replacement of Baggage Scanner Machine 4th Floor Admin Block at Karkardooma Court Complex, Delhi.
2026_PWD_291914_1
46/EE(E)/JED-1/PWD/2026-27
Open Tender
Electrical Works
Percentage
60 days
Karkardooma Court Complex.
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹45,779
16 Jun 2026
23 May 2026
5 Jun 2026
23 May 2026
5 Jun 2026
23 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing of Boom Barrier system at the entrance should provide a secure and reliable obstacle to the vehicles entering the premises . The barrier should be an Electro-Mechanical Boom Barrier, suitable for continuous and heavy-duty operation.It should be microprocessor-based with Genetec command software forfuture upgradation.The bidder shall submit a valid compatibility certificate from Genetec confirming the same.The Boom Arm length shall be up to 3 meters, made of hexagonal / octagonal profile for enhanced strength and stability.Duty cycle should be 100% and should operate on a 24V(DC) BLDC Motor.The minimum Ingress Protection (IP) rating shall be IP67 or better.The OEM of the Boom Barrier should have quality certificates like ISO9001:2015 & safety certificates ISO45001:2018 from a reputed certifying body like TUV, BV, SGS. The Boom Barrier shall be CE / UL certified, ensuring compliance with safety and performance standards complete with testing commissioning etc as required at site.Supplying and fixing of Boom Barrier system at the entrance should provide a secure and reliable obstacle to the vehicles entering the premises . The barrier should be an Electro-Mechanical Boom Barrier, suitable for continuous and heavy-duty operation.It should be microprocessor-based with Genetec command software forfuture upgradation.The bidder shall submit a valid compatibility certificate from Genetec confirming the same.The Boom Arm length shall be up to 3 meters, made of hexagonal / octagonal profile for enhanced strength and stability.Duty cycle should be 100% and should operate on a 24V(DC) BLDC Motor.The minimum Ingress Protection (IP) rating shall be IP67 or better.The OEM of the Boom Barrier should have quality certificates like ISO9001:2015 & safety certificates ISO45001:2018 from a reputed certifying body like TUV, BV, SGS. The Boom Barrier shall be CE / UL certified, ensuring compliance with safety and performance standards complete with testing commissioning etc as required at site. | 1 | Job | 17,58,500 | ₹17,58,500 |
| 2 | Supplying and fixing of Boom Barrier system at the entrance should provide a secure and reliable obstacle to the vehicles entering the premises . The barrier should be an Electro-Mechanical Boom Barrier, suitable for continuous and heavy-duty operation.It should be microprocessor-based with Genetec command software forfuture upgradation.The bidder shall submit a valid compatibility certificate from Genetec confirming the same.The Boom Arm length shall be up to 3 meters, made of hexagonal / octagonal profile for enhanced strength and stability.Duty cycle should be 100% and should operate on a 24V(DC) BLDC Motor.The minimum Ingress Protection (IP) rating shall be IP67 or better.The OEM of the Boom Barrier should have quality certificates like ISO9001:2015 & safety certificates ISO45001:2018 from a reputed certifying body like TUV, BV, SGS. The Boom Barrier shall be CE / UL certified, ensuring compliance with safety and performance standards complete with testing commissioning etc as required at site.Supplying and fixing of Boom Barrier system at the entrance should provide a secure and reliable obstacle to the vehicles entering the premises . The barrier should be an Electro-Mechanical Boom Barrier, suitable for continuous and heavy-duty operation.It should be microprocessor-based with Genetec command software forfuture upgradation.The bidder shall submit a valid compatibility certificate from Genetec confirming the same.The Boom Arm length shall be up to 3 meters, made of hexagonal / octagonal profile for enhanced strength and stability.Duty cycle should be 100% and should operate on a 24V(DC) BLDC Motor.The minimum Ingress Protection (IP) rating shall be IP67 or better.The OEM of the Boom Barrier should have quality certificates like ISO9001:2015 & safety certificates ISO45001:2018 from a reputed certifying body like TUV, BV, SGS. The Boom Barrier shall be CE / UL certified, ensuring compliance with safety and performance standards complete with testing commissioning etc as required at site. | 2 | Job | 1,68,150 | ₹3,36,300 |
| 3Supplying , Laying and fixing of following one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. | |||||
| 3.1 | 3 X 6 sq. mm copper conductor armoured | 180 | Mtrs | 802 | ₹1,44,360 |
| 3.2 | 3 X 4 sq. mm copper conductor armoured | 130 | Mtrs | 575 | ₹74,750 |
| 4Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | |||||
| 4.1 | 8 way, Double door | 1 | No. | 2,773 | ₹2,773 |
| 5Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||||
| 5.1 | Single pole | 6 | Nos. | 285 | ₹1,710 |
| 6Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.42 MB
BOQ_387444.xls
BOQ • 0.34 MB
Corrigendum.pdf
PDF • 0.37 MB
Corrigendum.pdf
PDF • 0.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .