Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC VILL MANKAR NORTH RAIPUR PO MANKAR DISTT PURBA BARDHAMAN PIN 713144 WB | MANKAR | PURBA BARDHAMAN | WB | 713144 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹19.9 L+₹45,822 (2.35%)Rejected-Finance VILL PO PS BELLATORE DIST BURDWAN PIN 722 203 WEST BENGAL | BELLATORE | BURDWAN | WEST BENGAL | 722203 | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹22.4 L+₹2.9 L (15.1%)Rejected-Finance OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L3 | Rejected-Finance Other than L1 bidder |
Tender Value
₹23.1 L
EMD Value
₹46,300
Closing Date
9 Dec 2024, 6:00 pmClosed
GE AF PANAGARH
GE AF PANAGARH MES AF STATION PANAGARH PO BIRUDIAH WEST BENGAL 713148
REPAIR/ MAINTENANCE OF COMPACT SUB STATION OF VARIOUS CAPACITIES, HANGER LAMPS, COPPER EARTHINGS ALONGWITH CONNECTED WORKS AT C-130J COMPLEX AT 87 SQN AT AFS PANAGARH UNDER GE (AF) PANAGARH
2024_MES_683413_1
C/8797/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STATION PANAGARH
Please refer tender document
7 documents required · 7 mandatory
₹500
GE AF PANAGARH
₹46,300
19 Dec 2024
12 Nov 2024
11 Dec 2024
12 Nov 2024
9 Dec 2024
25 Nov 2024
Amount
Disconneting of cables from LT ACB panel of various capacity (i.e 1600Amp-04 Nos, 1250Amp-05 Nos and 800Amp-08 Nos), checking and testing of relays with the help of relay testing kit (boosting kit) and resting of relays as per desire load current re-connecting the cables including calibration of relays, checking of tension spring and adjusting of proper tripping relay and fuctionting and replacement of old unserviceable parts if required and testing complete for tripping all directed by Engineer-in-Charge (Note: (i) Spares required i.e. Digital MFM (Multi function meter), standard control contactor 'N' range with accessories, shunt closing release, different capacity and voltage, self power numerical protection delay, fuse link with base will be paid and measured separately and taking down of spare parts shall be included in this item (ii) Minor parts other than note (i) and labour cost shall be inclusive in this rate)
S&F for Tmax power distribution circuit breaker of 400 Amps four pole adjustable thermal and magnetic setting type,50 KA breaking capacity, 415 volts, 50 Hz, ICU=100% including taking down old unserviceable power circuit breaker/MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed. (Make: ABB, Cat No. 1SDA054478R1, type- T5 frame- 400 TMA or equivalent of L&T /Legrand/siemens/schneider)
S&F for Tmax power distribution circuit breaker of 200 Amps four pole adjustable thermal and magnetic setting type,36 KA breaking capacity, 415 volts, 50 Hz, ICU=100% including taking down old unserviceable power circuit breaker/MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed. (Make: ABB, Cat No. 1SDA068109R1, type- XT4 250 frame- 200 TMA or equivalent of L&T /Legrand/siemens/schneider)
S&F for Tmax power distribution circuit breaker of 125 Amps four pole adjustable thermal and magnetic setting type,25 KA breaking capacity, 415 volts, 50 Hz, ICU=100% including taking down old unserviceable power circuit breaker/MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed. (Make: ABB, Cat No. 1SDA067042R1, type- XT2 160 frame- 125 TMA or equivalent of L&T /Legrand/siemens/schneider)
S&F for Tmax power distribution circuit breaker of 63 Amps four pole adjustable thermal and magnetic setting type,25 KA breaking capacity, 415 volts, 50 Hz, ICU=100% including taking down old unserviceable power circuit breaker/MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed. (Make: ABB, Cat No. 1SDA067037R1, type- XT2 160 frame- 63 TMA or equivalent of L&T /Legrand/siemens/schneider)
Supply only digital MFM (Multi function meter) flush mouting of size 96mm x 96 mm, complete all as specified and directed.
Supply only standard control contactor 'N' range with accessories having 2 x NO and 2 x NC (total 04 Nos contractor) coil voltage 220-230V,50Hz/ 230-240V, 60Hz complete all as specified and directed. (Make: ABB, Cat No- 1SBH141001R8022, (type of code reference- N22E or equivalent of L&T /Legrand/siemens/schneider)
Supply only shunt closing release with accessories, coil voltage 220V/ IEC/ 50Hz/220-240V complete all as specified and directed. (Make: ABB, Cat No- E1/6-T8 1SDA038302R1 or equivalent of L&T /Legrand/siemens/schneider)
Supply only low voltage power breaker (UVR) with accessories, coil voltage 440V/ IEC/ 50Hz/440-480V complete all as specified and directed. (Make: ABB, Cat No- 1SDA038315R1 or equivalent of L&T /Legrand/siemens/schneider)
Supply only self powered numerical protection relay 220V, 50Hz, without communication PORT complete all as specified and directed. (Make: ASHIDA, Model No ADR-141-S, CTSEC-1A or equivalent of ABB/L&T /Legrand/siemens/schneider)
Supply only HRC fuse link with Base rating-2-10 A complete all as specified and directed. (Make: ABB/L&T /Legrand/siemens/schneider)
Modification of existing indoor type VCB Panel servicing with electrical & Mechanical ON/OFF interlocking, Auxilary contact Block (6 NO + 6NC)- 04 Nos contactor 110V DC Eradicating complete existing control wiring for PS-01 & PS-02 complete all as specified and directed.
Repair/maintenance of Compact Sub Station Door (ie alignment of door, locking arrangement of door, repair/replacement of Hinges) including all accessories such as welding, nut bolt, door lock etc. complete all as specified and directed. (Note: all material and labour required for repair and replacement shall be included in this item as each job)
S&F for LED indicator lamp (R,B,Y) 50Hz, 240V AC complete as in repair all as specified and directed. (Make: C&S, Cat No. RCN7-1VL75 or equivalent of ABB/L&T /Legrand/siemens/schneider)
S&F for 400 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection complete with all accessories duly prewired and including fixing arrangement at different hanger area upto height of 24 mtr by providing clamps, nuts, bolts, and washers etc after taking down old unserviceable flood light fitting of any type duly disconnecting the electric supply complete all as specified and directed. (Note: (i) Contractor shall ensure all safety aspects of menpower who are working at site duly proper insurance of the individual (ii) All necessary tools and plants for fixing and taking down of lamp fittings light boom ladder with safety equipment etc shall be provided by the contractor (iii) LM-79 and LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings to the Engineer-In-Charge. (iv) Warranty certificate shall be submitted for LED light fitting by the contractor and also company warranty certificate submitted as per standard format for minimum 50000 Hrs from the date of install the light fittings to the Engineer-In-Charge before payment. (v) LED light fitting and drivers shall be of same make.) (Make:- Crompton, Model No CFS-512-400-57-30D-HL3-GL-NGG or Havells Cat No. JETARESOLUTEFLS400W2MLED75730DTOTG or equivalent in Philips)
Dismantling of existing Highmast light for 20 to 26 mtr height incl repairs to raising and lowering system of High mast light and repair to double drum winch, proper checking of lubrication system and tighting of trailing cable repairs to remote for up & down carriage, refixing of flood light luminaries with suitable bracket and making serviceable incl base protection of High Mast Light all as specified and directed. (Note: (i) Replacement of defective parts and accessories shall be included in this item. (ii) Transportation and T&P i.e. Hydra crane, Ladder, spanners of any other equipments for repair of High mast Light shall be provided by contractor and cost for the same deemed to be included in quoted rate.)
M&L for rewinding of 3 phase squirrel cage induction motor of 1.5 HP capacity including taking down carefully after removing all electrical & mechanical connection from Highmast pole of any height, taking into workshop, removing burnout winding wire carefully and rewinding with suitable size of new winding wire (pvc insulated ) of same gauge, reassembling, testing & commissioning all as specified and directed.
S&F for 500 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection complete with all accessories duly prewired and including fixing arrangement at different high mast by providing clamps, nuts, bolts, and washers etc after taking down old unserviceable flood light fitting of any type duly disconnecting the electric supply complete all as specified and directed. (Note:- (a) LM-79 and LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings to the Engineer-In-Charge. (b) (iv) Warranty certificate shall be submitted for LED light fitting by the contractor and also company warranty certificate submitted as per standard format for minimum 50000 Hrs from the date of install the light fittings to the Engineer-In-Charge before payment. (Make:- Crompton, Model No CFS-513-500-57-60D-SL-GL-NSG or Havells Cat No. JETAVALOURLEFL500W4MLED757PINTMBLTG or equivalent in Philips)
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
KMT INDUSTRIES (BID ID -3184412)
M/S Ali Trading Co (BID ID -3178773)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .