Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance WARD 18 PLOT NO 153 PHASE II HOUSING COLONY NEAR ROTARY EYE HOSPITAL UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹5.0 L
EMD Value
₹10,000
Closing Date
17 Feb 2022, 4:00 pmClosed
Executive Engineer ED-II JPDCL Jammu
Office of the Executive Engineer ED-II JPDCL Jammu
Rate contract for Supply Installation Testing Commissioning of 11/0.433KV 63KVA ,100KVA Distribution Transformer in different locations of Electric Division-II on Turnkey Basis during 2021-22 financial Year
2022_PDD_159493_1
Enit 66A of 2021-22 dated 05-02-2022
Open Tender
Electrical Works
Turn-key
30 days
Within Jurisdiction of the XEN ED- II JPDCL Jammu
Please refer Tender documents.
3 documents required · 3 mandatory
₹200
Executive Engineer ED-II JPDCL Jammu
₹10,000
22 Feb 2022
5 Feb 2022
18 Feb 2022
5 Feb 2022
17 Feb 2022
5 Feb 2022
5 Feb 2022 - 17 Feb 2022
Amount
Supply, Installation & commissioning of 11/0.433kV, 100KVA , 3-phase Distribution Transformer
Supply, Installation & commissioning of 11/0.433kV, 100KVA , 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) with LV Cable Box having detachable Aluminium Gland plate on already existing Substation Structure.
Providing & Fixing of PVC Cable 185 mm² alongwith 12 Nos Al. Thimble of 185 mm²
Providing & Fixing of LT Distribution Box for 100kVA DTR with 160A MCCB for incomer & SFU's for Outgoing Circuit
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Description of Work / Item(s)
Amount
Supply, Installation & commissioning of 11/0.433kV, 63KVA , 3-phase Distribution Transformer
Supply, Installation & commissioning of 11/0.433 KV, 63 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, "BIS Marked" (Aluminium Wound) alongwith LV Cable Box having detachable Alumnium Gland plate.
Providing & Fixing of PVC Cable 120 mm² alongwith 12 Nos Al. Thimble of 120 mm²
Providing & Fixing of LT Distribution Box with100 Amp MCCB for incomer & switch fuse unit for Out Going Ckt.
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
JASMEET SINGH
M/s R.P Electronics and Electricals Company
NEW ALLIED TRADERS
RATHORE ELECTRICAL WORK AND SUPPLIER
KULBUSHAN KUMAR
ARJUN SINGH
M/S TRANS TECH ENGINEERS
M/S DAYAL BUILD TECH
RATHORE ELECTRICAL WORK AND SUPPLIER
JASMEET SINGH
M/S TRANS TECH ENGINEERS
M/S MOHD MUNSHI
KULBUSHAN KUMAR
M/s R.P Electronics and Electricals Company
ARJUN SINGH
M/S DAYAL BUILD TECH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .