Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC NO 16 11 ANBAZHAGAN NAGAR MAIN ROAD MINJUR 601203 | THIRUVALLUR | TAMIL NADU | 601203 | ₹13.0 L Quoted ₹14.9 L | L1 | Accepted-AOC L1 TENDERER |
| 2 | L2₹17.9 LRejected-AOC 210 1 C ARIYAMANGALAM CORPORATION ROAD JEGANATHAPURAM TIRUCHIRAPPALLI TAMIL NADU 620010 | TIRUCHIRAPPALLI | TAMIL NADU | 620010 | ₹17.9 L | L2 | Rejected-AOC L2 TENDERER |
| Sl No | Description | Qty | Unit | Andavar Engineering Industries L2 | SAHIRA ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Charges for Removal of actuator from the valve stem, removal of actuator thrust base, Dismantling of valve bonnet, removal of valve stem and gate and Cleaning of valve internals, Lapping of valve gate seating area, Blue matching of Valve gate seating area and seat in valve body and Assembling of valve gate and stem in the valve casing, assembling of valve bonnet, renewal of gasket in valve bonnet, fixing the actuator on the valve stem, renewal of thrust roller bearings and commissioning the valve (Motor operated, GV -200/Class-300) including cost of consumables and hire charges for T&P's. | 9 | NOS | 87,780 ₹7.9 L | 73,150 ₹6.6 L |
| 2.00 | Attending Gland Leak in 200 NB Class-300 inert steam main valve
Charges for isolating the valve, attending gland leak by loosening gland nuts, replacing glands and tightening the gland, etc., including cost of consumables and hire charges for T&P's. | 36 | NOS | 4,440 ₹1.6 L | 3,700 ₹1.3 L |
| 3.00Charges for Welding if any punctured steam pipe line by IBR quality welding by removal of existing GI/AL Cladding sheet and insulation after completion of welding, reassembling the same. | |||||
| 3.01 | Charges for welding the steam pipeline by IBR quality welding includes edge preparation, fit up preheating and post heating and completion of welding. | 18 | JOINTS | 5,340 ₹96,120 | 4,450 ₹80,100 |
| 3.02 | Charges for renewal/rectification of damaged insulation sheet and refaxing of new/retrieved GI/AL sheet over the insulation. | 22 | SQ.MTR | 660 ₹14,520 | 550 ₹12,100 |
| 3.03 | Charges for removal of damaged insulation and re-fixing with new/old insulation wool material in critical pipelines, valves, ducts etc., | 22 | SQ.MTR | 1,110 ₹24,420 | 925 ₹20,350 |
| 4.00Material Supply Portion: | |||||
| 4.01 | Thrust roller Bearing Model AXK85110 for 200NB Inert Steam valve. | 18 | NOS | 1,590 ₹28,620 | 1,325 ₹23,850 |
| 4.02 | Stem Nut for 200NB Inert Steam valve | 4 | NOS | 85,200 ₹3.4 L | 71,000 ₹2.8 L |
| 4.03 | Actuator Thrust Base for 200NB Inert Steam Valve | 4 | NOS | 69,360 ₹2.8 L | 57,800 ₹2.3 L |
Tender Value
Refer Docs
EMD Value
₹12,200
Closing Date
4 Feb 2026, 2:00 pmClosed
CHIEF ENGINEER/NCTPP III
CHIEF ENGINEER/NCTPP-III CHENNAI 600 120
NCTPP III Mechanical I Circle Mill Plant Maintenance Division Breakdown Maintenance works in the Mill Inert System for a period of One year from the date of handing over of site
2026_EB_645442_1
CE/ NCTPP III/SE/M-I/OT-10/2025-26
Open Tender
Maintenance Works
365 days
NCTPP III CHENNAI
REFER TENDER NOTICE
2 documents required · 2 mandatory
₹0
₹12,200
Yes
27 Mar 2026
21 Jan 2026
5 Feb 2026
21 Jan 2026
4 Feb 2026
21 Jan 2026
Charges for Removal of actuator from the valve stem, removal of actuator thrust base, Dismantling of valve bonnet, removal of valve stem and gate and Cleaning of valve internals, Lapping of valve gate seating area, Blue matching of Valve gate seating area and seat in valve body and Assembling of valve gate and stem in the valve casing, assembling of valve bonnet, renewal of gasket in valve bonnet, fixing the actuator on the valve stem, renewal of thrust roller bearings and commissioning the valve (Motor operated, GV -200/Class-300) including cost of consumables and hire charges for T&P's.
Attending Gland Leak in 200 NB Class-300 inert steam main valve Charges for isolating the valve, attending gland leak by loosening gland nuts, replacing glands and tightening the gland, etc., including cost of consumables and hire charges for T&P's.
Charges for Welding if any punctured steam pipe line by IBR quality welding by removal of existing GI/AL Cladding sheet and insulation after completion of welding, reassembling the same.
Charges for welding the steam pipeline by IBR quality welding includes edge preparation, fit up preheating and post heating and completion of welding.
Charges for renewal/rectification of damaged insulation sheet and refaxing of new/retrieved GI/AL sheet over the insulation.
Charges for removal of damaged insulation and re-fixing with new/old insulation wool material in critical pipelines, valves, ducts etc.,
Material Supply Portion:
Thrust roller Bearing Model AXK85110 for 200NB Inert Steam valve.
Stem Nut for 200NB Inert Steam valve
Actuator Thrust Base for 200NB Inert Steam Valve
GI Sheet Thickness 0.63mm (22 sq.m)
Insulation Wool Thickness 75mm
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
BOQ_773488.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid