Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹23.8 L+₹32,060 (1.36%)Rejected-AOC | L2 | Rejected-AOC not found lowest | |
| 3 | L3₹25.9 L+₹2.4 L (10.1%)Rejected-AOC | L3 | Rejected-AOC not found lowest | |
| 4 | L4₹28.0 L+₹4.5 L (19.2%)Rejected-AOC | L4 | Rejected-AOC not found lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
11 Mar 2023, 6:00 pmClosed
GE Basoli
GE Basoli PO lakhanpur Distt Kathua JK
Repair/Maintenance of STPs and as allied works and LT panel, busbar and allied works at Basoli and Janglot under GE Basoli
2023_MES_580173_1
GE/BAS-80/2022-23
Open Tender
Civil Works
Item Rate
180 days
Basoli and Janglot under GE Basoli
Class D Catg b (i)
7 documents required · 7 mandatory
₹500
GE Basoli
₹60,000
12 May 2023
10 Feb 2023
13 Mar 2023
10 Feb 2023
11 Mar 2023
24 Feb 2023
Amount
Material and labour for. lifting and lowering of submersible pump set 30/40 HP capacity and of size 80/100mm bore of dia with flanged column pipe ( each length of column pipe not more than 3 mtr ) maximum depth of submersible pump not more than 150mtr by opening the column pipe after removing old burnt / rusted nut bolts, washers including replacement of rubber gasket and nut bolts and washer etc, complete all as specified and as directed .
Material and labour for. lifting and lowering of submersible pump set 15 to 25 HP capacity and of size 80/100mm bore of dia with flanged column pipe ( each length of column pipe not more than 3 mtr ) maximum depth of submersible pump not more than 150mtr by opening the column pipe after removing old burnt / rusted nut bolts, washers including replacement of rubber gasket and nut bolts and washer etc, complete all as specified and as directed .
Dismantling and step opening of unsv booster/ centrifugal pump set of capacity 40 HP and segrigated all serviceable and unserciveable parts, kept at site for re use after repair/ replacement and maintenance of pumps set by replacing of impeller, bushes, bearing and other required parts of suitable size and making the pump serviceable including servicing, cleaning,greasing, overhauling,re-alignment with lock, key, nut, bolts,washers etc. and reassembling the same after testing complete all as specified and directed.
Dismantling and step opening of unsv booster/ centrifugal pump set of capacity 50 HP and segrigated all serviceable and unserciveable parts, kept at site for re use after repair/ replacement and maintenance of pumps set by replacing of impellar, bushes, bearing and other required parts of suitable size and making the pump serviceable including servicing, cleaning,greasing, overhauling, re-alignment with lock, key, nut, bolts,washers etc. and reassembling the same after testing complete all as specified and directed.
Repair/maint of unsv submersible motor 30 to 40 HPfrom bore well and dismantling and strip opening of 3 phase 415 volt, 2900 rpm at site in presence of JE/Engineer-in-charge for checking complete carrying motor to workshope for repair of motor ,dismentling and step opening to complete of under mentioned capacity, and segrigate all serviceable parts and kept at site for reuse and rewinding with PVC insulated supper quality water proof copper winding wire of suitable size/gauge and nos of turns incl replacing insulated material varnish, drying and submersible cable for connection from motor to out side up to 1.5 mtr length and reassembling including testing at site on full load complete all as specified and directed.
Repair/maint of unsv submersible motor 15 to 25 HPfrom bore well and dismantling and strip opening of 3 phase 415 volt, 2900 rpm at site in presence of JE/Engineer-in-charge for checking complete carrying motor to workshope for repair of motor ,dismentling and step opening to complete of under mentioned capacity, and segrigate all serviceable parts and kept at site for reuse and rewinding with PVC insulated supper quality water proof copper winding wire of suitable size/gauge and nos of turns incl replacing insulated material varnish, drying and submersible cable for connection from motor to out side up to 1.5 mtr length and reassembling including testing at site on full load complete all as specified and directed.
Dismantaling and step opening of burnt out electric motor of capacity 50 HP and rewinding with supper enameled copper wire of existing gauge, number of turns, insulating and heat varnishing, greasing complete including replacement of bushes, bearing check nut, and other required parts and applying two coats of synthetic enamel paint over a coat of red oxide primer to external surface of motor and testing complete all as specified and directed.
Dismantaling and step opening of burnt out electric motor of capacity 40 HP and rewinding with supper enameled copper wire of existing gauge, number of turns, insulating and heat varnishing, greasing complete including replacement of bushes, bearing check nut, and other required parts and applying two coats of synthetic enamel paint over a coat of red oxide primer to external surface of motor and testing complete all as specified and directed.
Material and Labour to repair / maint of unsv booster/ centrifugal pumps of 20 HP capacity and dismantling and strip opening to complete booster/centrifugal pump under mention cap and segrigated all serviceable parts and kept at site for reuse incl replacement of bronze impellar of suitable size and bushes bearing and other required parts and making serviceable to the pump complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete and all as directed.
All as per description serial item No 6 above but 10 HP capacity
All as per description serial item No 6 above but 7.5 HP capacity
All as per description serial item No 6 above but 5 HP capacity
All as per description serial item No 6 above but 3 HP capacity
All as per description serial item No 7 above but 2 HP capacity
Material and Labour to repair / maint of unsv booster/ centrifugal pumps motor electric driven for 20HP capacity and dismantling and opening complete motor under mention cap and segrigated all serviceable parts and kept at site for reuse incl rewinding motor with supper enamled wire of suitable gauge complete , and replaceing bushes, bearing check nut, and other required parts an+B36d varnishing the same incl painting of motor , making serviceable to the motor complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete and all as directed.
All as per description serial item No 15 above but 10 HP capacity
All as per description serial item No 15 above but 7.5 HP capacity
All as per description serial item No 15 above but 5 HP capacity
All as per description serial item No 15 above but 3 HP capacity
All as per description serial item No 15 above but 2 HP capacity
Supply only Contactor ML3, Make: semense/ L&T or equivalent as approved by GE.
Supply only contact kit for ML3 contactor. Make: semense/ L&T or equivalent as approved by GE.
Supply only contact kit for ML2 contactor. Make: semense/ L&T or equivalent as approved by GE.
Supply only Spare coil for ML2 contactor. Make semense/ L&T or equivalent as approved by GE.
Supply only Electronic timer (Type ET-100 of 9 to 30 sec of make semense/ L&T or equivalent as approved by GE.
Supply only overlod relay MN5 of L&T (Range 10-15 A) make semense/ L&T or equivalent as approved by GE.
Supply only overlod relay MN5 of L&T (Range 15-30 A) make semense/ L&T or equivalent as approved by GE.
S & Fix MCCB 160 Amps 415 Volts 25 KA four pole, 50 hz megnetic fix type all as specified and directed
S & Fix MCCB 100 Amps 415 Volts 16 KA four pole, 50 hz megnetic fix type all as specified and directed
S & Fix MCCB 63 Amps 415 Volts 16 KA Three pole, 50 hz megnetic fix type all as specified and directed
S & Fix MCCB 32 Amps 415 Volts 16 KA Three pole, 50 hz megnetic fix type all as specified and directed
S & Fix MCB Triple pole 32 Amps 415 Volts 10KA all as specified and directed
S & Fix MCB Triple pole 16 Amps 415 Volts 10KA all as specified and directed
M&L for painting of CI/MS pipe of any size ie 200 mm/150 mm/100 mm dia at STP No.1 with one coat red oxide primer and synthetic enamel black & blue paint by applying two coat and to match with existing colour coading all as specified and directed.
M&L for painting of CI/MS pipe of any size ie 200 mm/150 mm/100 mm dia at STP No.2 with one coat red oxide primer and synthetic enamel black & blue paint by applying two coat and to match with existing colour coading all as specified and directed.
M&L for painting of CI/MS pipe of any size ie 200 mm/150 mm/100 mm dia at STP No.3 & 4 with one coat red oxide primer and synthetic enamel black & blue paint by applying two coat and to match with existing colour coading all as specified and directed.
M&L for painting of Dual Media filter at STP No.1, 3 & 4 with one coat red oxide primer and synthetic enamel Aluminium paint by applying two coat and to match with existing colour coading all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25cm completed all as specified and directed.
Supply & laying of approved quality sand under cable upto 15cm before laying the cable and 8cm over the cable after laying, punned down to overall thickness of 18cm in trenches for cable cushioning complete all as specified and directed. (Punned thickness shall be measured)
Material and labour for well burnt, old size Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable with width equal to length of brick complete all as specified and directed.
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 95 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,cross section area are as under of Make- polycab/KEI/RPG including disconnecting and taking out old unsv LT/AB cable.Note : (I) Earth work/ sand cushioning shall be measured and paid separately .
Supply and laying for 80 mm bore dia of Galvanised iron tubing "Medium grade" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend,elbows,sockets reducer ,nipples and union including taking out old unserviceable GI tubing complete all as specified and directed.
Supply and laying for 50 mm bore dia of Galvanised iron tubing "Medium grade" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend,elbows,sockets reducer, nipples and union including taking out old unserviceable GI tubing complete all as specified and directed.
Supply and laying for 40 mm bore dia of Galvanised iron tubing "Medium grade" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend,elbows,sockets reducer ,nipples and union including taking out old unserviceable GI tubing complete all as specified and directed.
Supply and laying for 25 mm bore dia of Galvanised iron tubing "Medium grade" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend,elbows,sockets reducer ,nipples and union including taking out old unserviceable GI tubing complete all as specified and directed.
Supply and laying for 20 mm bore dia of Galvanised iron tubing "Medium grade" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend,elbows,sockets reducer ,nipples and union including taking out old unserviceable GI tubing complete all as specified and directed.
Supply and fix in repair for 25 mm bore dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in repair for 20 mm bore dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point all as specified and directed.
Supply and laying GI pipe light grade galvanized with all fittings laid in trenches for cable protection of 50 mm bore all as specified and directed.
Taking out faulty U/G cable off size by removing PCC covers or bricks of any specification for replacing the same with new LT U/G cable as mentioned in item Nos. Item No 8 to 15 all specified and as directed.
Supply, laying in replacement of LT U/G cable with aluminum conductor heavy duty armoured with GI strips 1100 volt grade of size 3.5 core 300 Sq mm per IS specifications complete all as specified and as directed.
All as per srl item No 53 above but size 120 Sq mm x 3.5 core 120 Sq mm all as specified and directed.
All as per srl item No 53 above but size 95 Sq mm x 3.5 core all as specified and directed.
All as per srl item No 53 above but size 70 Sq mm x 3.5 core all as specified and directed.
All as per srl item No 53 above but size 50 Sq mm x 3.5 core all as specified and directed.
All as per srl item No 53 above but size 25 Sq mm x 3.5 core all as specified and directed.
All as per srl item No 53 above but size 16 Sq mm x 4 core all as specified and directed.
All as per srl item No 53 above but size 16 Sq mm x 2 core complete all as specified and directed.
Supply and fix for DWC high density polyethylene pipes having dia 63/50 mm as per site requirement having corrugation on the wall and plain surface on the wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required complet all as specified and directed.
S&F in Replacement of ACSR conductor steel re-inforced of any size on pole including binding wire and line taps of appropriate size & type complete all as directed.
Supply and fix in replacement of PVC line phase separators for over head line LT conductor of any size suitable to stand 1100 volts to maintain the required spacing between 5 conductors complete all as per site requirement and all as directed.
Taking down unsv outdoor LT panel with MCCB after disconnecting the electric supply and keeping in safe custody for giving credit to the contractor all as specified.
M&L Earthing complete with GI earth plate electrode 60x60cmx6.3mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with topedge of the plate not less than 1.5m below normal ground level connected to GI earth strip 25x4 mm dia protected by GI pipe light grade 15mm dia, 20 mm medium grade for watering with funnel including test point up to 7.5 meter from earth pit, common salt, charcoal dust and connected to panel bd/DB by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 5 of SSR part I including necessary earth work and excavations in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc complete a as specified.
Taking down Aluminium TPN busbar/Changeover any size and any capacity after disconnecting the electric supply and keeping in safe custody for giving credit to the contractor all as specified.
S&F in replacement of off load changeover switch in sheet metal enclosure four pole 100 Amps capacity suitable for 415 volt, 50 Hz with side operating handle complete with connected fixing arrangement switches, fastness, gutties etc. for fixing the same on wall / panel etc all as specified and directed.
S&F in replacement of off load changeover switch in sheet metal enclosure four pole 63 Amps capacity suitable for 415 volt, 50 Hz with side operating handle complete with connected fixing arrangement switches, fastness, gutties etc. for fixing the same on wall / panel etc all as specified and directed.
S & F of aluminium TPN busbar chamber of capacity 100 amps, 415 volt with proper insulator mounting/routing in properly wall/surface with suitable PCC/Nuts & bolts complete all as specified and directed.
DASHMESH BUILDERS
SHUSHANT ASSOCIATES
Ashoka Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .