| 1 | L1₹10.5 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC Being the lowest and reasonable bidder | |
| 2 | L2₹13.1 L+₹1.2 L (10.4%)Rejected-AOC | L2 | Rejected-AOC Being the other than lowest bidder | |
| 3 | L3₹13.4 L+₹1.5 L (12.6%)Rejected-AOC | L3 | Rejected-AOC Being the other than lowest bidder | |
| 4 | L4₹14.1 L+₹2.2 L (18.2%)Rejected-AOC | L4 | Rejected-AOC Being the other than lowest bidder | |
| 5 | L5₹16.7 L+₹4.8 L (40.1%)Rejected-AOC 120 144 III PHASE APNA VIHAR JAMMU J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180010 | L5 | Rejected-AOC Being the other than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
18 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Nagrota
HQ CWE Nagrota Co 56 APO
REPAIR/REPLACEMENT OF HT OH/UG LINES, TRANSFORMER WITH CONNECTED ITEMS AT 213 TC UNDER GE NAGROTA
2023_MES_613866_1
CWE/NGT-21/2023-24
Open Tender
Civil Works
Item Rate
182 days
Transit Camp
As per NIT and tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Nagrota
₹40,000
Yes
2 Jan 2024
16 Aug 2023
25 Sept 2023
16 Aug 2023
18 Sept 2023
4 Sept 2023
16 Aug 2023 - 23 Aug 2023
Amount
Taking down transformer mounted on two/four pole structure or on plateform / indoor floor mounted carefully from their position after removing electrical connection, earthing leads etc, for executing necessary comprehensive preventive maintenance as well as repairs necessiated, including to and fro transporting to MES store yard/ contractor workshop and refixing after execution of maint/repair to their original position or to other location as directed of capacity 40 KVA to 315 KVA.
Labour, tools & plants only for opening the top cover of transformer out/in door type, step down 11 KV/0.415 KV of cap 40 KVA to 315 KVA, lifting of core and winding, draining out transformer oil into container and keeping aside for treatment and reuse, carry out strip inspection of core and windings for comprehensive routine, preventive maintenance and any other necessary repairs required to be executed. Refitting the core & windings after carry necessary routine maintenance / preventive maintenance or repairs so ordered making all electrical connections, providing sundry items i.e bolts, nuts & washers, reassembling the transformer complete, including testing and commissioning to the entire satisfaction of the Engineer-in-Charge, complete all as specified and as directed.
Cork sheet 6mm thick gasket packing to transformers top cover of various capacities upto 160 KVA outdoor/indoor, complete all as specified and as directed.
Filtration, dehydration of transformer oil as drained out from transformer vide Sch 'A' Srl item No. 01 here in before to make the oil fit for re-use by improving its dielctric strength not less than 40 KV. Oil below 40KV di-electric strength shall be replaced with new oil (new oil for topping/or for replacement shall be measured and paid separately under appropriate items of Sch 'A') here in after.
Supply, treating (dehydrating), filling new transformer oil in transformers for topping up levels or for replacement of unfit oil. New oil shall have dielectric strength not less than 60 KV and shall be conforming to IS 335.
Taking out old breathers from transformer, supplying and fixing new breather duly filled with activated agent i.e silica gel for transformer of cap 40 KVA to 315 KVA
Dismantling Core, taking out damaged coils (HV Coils) from its position replacement, including supplying and fixing new winding coils with super enamelled copper winding wires of required gauge, number of turnings & weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and as directed by the Engr-in-Charge
Taking out damaged coils (LT Coils) from its position replacement, including supplying and fixing new winding coils with cotton braided copper wire or strip of appropriate size (thickness & width), number of turnings & weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and as directed by the Engr-in-Charge.
Taking out HV porcelain bushes from transformers for replacement being damaged, including supply and fixing new HV porcelain, vitreous white, brown or green of voltage grade 11KV bushes to suit the size of transformers of different makes transformer of cap 40 KVA upto 315 KVA indoor.
Taking out LV porcelain bushes from transformers for replacement being damaged, including supply and fixing new LV porcelain, vitreous white, brown or green of voltage grade 1100 V bushes to suit the size of transformers of different makes transformer of cap 40KVA upto 315 KVA indoor/out door
Taking out worn out HV metallic alloy(brass/gun metal) bush rods, including supply and fixing new HV metallic alloy (gun metal/brass) bus rods of suitable length and dia with necessary nuts, washers and bushing packing to prevent oil leaking from the bushes including making necessary connections for transformer of cap 50 KVA to 315 KVA
Taking out worn out LV metallic alloy (brass/gun metal) bush rods, including supply & fixing new LV metallic alloy (gun metal/brass) bus rods of suitable length and dia with necessary nuts, washers and bushing packing to prevent oil leaking from the bushes including making necessary connections for transformer of cap 50 KVA to 315 KVA
Supply, fixing, commissioning & testing of dial type temp gauge 100mm dia dial range 0-100 Cº complete with thermostat built in switch
M & L complete for taking out unserviceable tap changing gear for replacement, including supply & fixing, making connections, testing & commissioning new tap changing gears in transformers of any description / rating and make complete all as specified and as directed.
M & L complete for denting out damaged external cooling tube of transformer & bring them to their original shape, of any type and description against of cap 40 KVA to 315 KVA.
M & L for welding to iron surface sheet steel in cooling tube/ body of transformer of any description to prevent leakages of oil , welding in repairs exceeding 2.5 cm but n.exc 5 cm in length, thickness of metal to be welded n.exc 6mm.
Painting to transformer's old painted surface of steel after cleaning, scraping and preparing and filling cavities and providing one coat of synthetic enameled grey paint with spray gun process to transformer of Cap 40 to 315 KVA indoor/outdoor type
Disconnecting and removing to workshop opening for repair automatic voltage stabilizer for automatic operation air cooled servo controlled type input voltage 260-440V and output voltage 420 V of capacity 50 KVA to 160 KVA complete all as specified and as specified and as directed Note : Replacement of the parts if any found worn out/defective shall be measured and paid for separately.
Dismantling and rewinding of dimmer coil with super enameled copper winding wire including varnishing tapping and insulating material to get same capacity of 50 KVA to 160 KVA
Replacement of electronic circuit plate complete with DC transformers (PCB cold) complete capacity of 50 KVA to 160 KVA
Dismantling of old servo motor and supply and fix new servo motor of existing size and capacity complete all as specified and directed.
Dismantling of old carbon brush with carbon holder including supply and fixing new one complete
Replacement of brass studs fixed for input and output of stabilizer with brass nuts for upto 160 KVA cap
Painting to voltage stabilizer's old painted surface of steel after cleaning scrapping and preparing and filling cavities and providing two coat of synthetic enameled cream paint with spray gun process to voltage stabilizer of cap upto 160 KVA
10mm thick Synthetic insulated mat suitable for 11000 Volt grade (ISI Marked) of size 2m x 1m x 10mm complete all as specified and directed.
Material and labour for 80 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe.
Material and labour for cement concrete 1:4:8 type D2 using 40mm graded crushed trap stone aggregate for foundation of poles/stays.
M & L heat shrink cable end joint suitable termination outdoor type for 3 core cable XLPE with aluminium conductor 11000 volt graded (earthed) of cross sectional area 95 sqmm complete kit with all accessories and jointing material and testing after jointing
M & L cable jointing kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm.
Material & Labour for cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending, drilling of holes for bolts in any shape or size as indicated and applying two coats of aluminium paint over a coat of red oxide primer including dismantling of existing mild steel cross arm with clamps from LT/HT poles of any height, place and position.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25M deep below natural ground level ) with top edge of plate not less than 1.5M below normal ground level, surrounded from all sides alternate packed layer of char coal dust and comman salt and electrode connected with galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR part I including necessary earth work in any type of strata, foundation of pit and wall using PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate, 40 mm thick pit cover slab using RCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate with 6 mm dia MS bar @ 100 mm C/C both ways, GI medium grade 20 mm dia pipe for watering including funnel with wire mesh and 15 mm bore GI light grade pipe for earth lead wire protection up to 7.5 mtr complete all as directed including testing complete on completion. Note for item No. 26 & 27 (i) GI wire/strip or protection pipe 15mm/40mm dia upto 7.5 RM included the quoted rate. (ii) The qty above the 7.5 RM shall be measured & paid separetely
All as per Srl Item No. 33 above but using 32x6mm GI earth strip as earth lead & 40mm dia light grade GI protection pipe complete all as specified and directed. Note for item No. 33 & 34 (i) GI wire/strip or protection pipe 15mm/40mm dia upto 7.5 RM included the quoted rate. (ii) The qty above the 7.5 RM shall be measured & paid separetely
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe all as required at site.
Supply & fixing for GI strip 32x6mm on wall/batten or recessed or buried in ground complete all as directed by Engineer-in-Charge.
Supply & Laying in trench or fixed to pole XLPE cable insulated screened, PVC bedded steel strip or wire, armoured, heavy duty electric power cable with aluminium conductor,11000 volts grade, cross-sectional area 95 Sqmm 3 core including taking down/out existing old HT cable of any size and type complete all as specified and directed. (Note : Excavation, returning and removal shall be measured and paid separately).
Excavation in trenches, not exc 1.5 m wide and not exc 1.5m in depth; and getting out any type of soil for errection of HT poles/ laying of HT UG cable and stay assembly complete.
Returning, filling including spreading, levelling, watering and ramming in layers not exceeding 25cm in hard dense soil.
Removing excavated surplus hard dense soil to a distance not exceeding 50M and depositing where directed at a level not exceeding 1.5M above the starting point.
Supply, laying and spreading in layers dry clean river sand for cable cushioning with a layer of sand 8 Cm depth before laying & 15 cm depth after laying the cable punned down to a depth of 10 cm above the top of the cable.
Supply & Laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 450mm x 230mm x 50mm thick complete all as specified.
Supply & laying well burnt bricks (old size), sub class B designation 75, laid flat for cable protection complete all as specified and directed by Engineer-in-Charge.
Material and labour for lightning arrester non linear resistor type comply with IS 3070 Part I 1985 for alternating current system multiple spark gap suitable for voltage grade 11000 volt discharge cap 65 KA complete with all fittings, including dismantling the old unserviceable one.
Material and labour for switch Air break gang operated Triple pole, mechanically operated mounted on insulator & steel frame with operating mechanisum worked from ground level for current rating upto 200 Amps 11000 Volts all with male & female contacts, post insulator 15 Nos, operating rod, handle etc and renewal of jumpers with heavy duty alkathine pipe cable connections including dismantling of old unserviceable switches vertical/horizontal mounted, including insulator & operating mechanisum for repair/replacement of broken/worn out components and insulators etc complete.
Supply and fix and draw ACSR Weasel/Squirrelconductor of size 06 strands of aluminium of 2.59/2.11 mm dia and 1 strand of steel of 2.59/2.11 mm dia on HT poles, bringing the sag within limit fixing on Insulator/Cross arms by means of necessary binding with 16 SWG aluminium binding wire and providing alkathin pipe of approved quality for jumpers, reconnecting the service connections after removing the carbon material including taking down ACSR conductor of any size & type from LT poles at any height position and place complete all as specified and directed by Engr-in-Charge.
Supply and errect Pre-stressed concrete pole 11 mtr long of size 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 with earthing strip on top and bottom of the poles including dismantling of existing HT poles of any description (tubulat/steel/RCC) by cutting from the bottom including dismantling the existing connections, channels, clamps, nuts, bolts etc complete all as specified and directed by Engr-in-Charge. Note:- Excavation incl refilling and removing material/concrete work shall be measured and paid separately.
Material & Labour for stay asembly comprising of stay bow (4000 x 14mm), stay rod 215 cm long and 20 mm dia with nuts, stay plate 300 x 300 x 6 mm thick and 2 nos of thimble complete as shown in electric plate no 1 of SSR part-1 connected to loop type insulator, including dismantling old unserviceable stay assembly complete including loop insulator wire etc from LT poles NOTE :- Earth work excavation, concrete and loop type insulator shall be measured and paid separetely under relevent items of Sch 'A'.
Supply and fix LT loop type insulators, vitreous, porcelain brown, white or green insulators for working pressure of 1100 volts grade of large size with over all dimensions 90 x 140 mm clearance of hole 25.50 mm including dismantling of existing LT loop type insulator from LT poles of any height place and position.
Supply and fix HT Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised iron mild steel spindle two galvanised iron washers and one galvanised iron nuts, 150 mm height, 150 mm dia for conductor 11000 volts grade including dismantling of existing HT pin type insulator from HT poles of any height, place, and position.
Supply and fix LT Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised iron mild steel spindle two galvanised iron washers and one galvanised iron nuts, 100 mm height, 65 mm dia for conductor 1100 volts grade including dismantling of existing LT pin type insulator from LT poles of any height, place, and position.
Supply and fix LT shackle type insulators, vitreous, porcelain brown, white or green insulators for working pressure of 1100 volts grade of 90 mm dia, 75mm height including galvanised mild steel strips 31 x 3 mm size and 12 mm dia bolts, nuts, and washers on existing cross arms including dismantling of existing HT shackle type insulator from LT poles of any height place and position.
S&F Galvanised stay wire stranded of size 7/4 mm including necessary binding, strengthening complete all as directed
M&L for Preparing old painted surfaces of steel tubular poles sewaged pole of any description and length not exc 9 above ground level erected in vertical position in HT OH line including cross arms of angle iron/ channel section clamps brackets etc with one coat of aluminium paint 7.5 mtr from top of the pole onward & remaining with black & white paint strip in 30 cm width alternatively upto ground level & numbering the pole with white paint on black paint base 20 cm dia circular/square shape complete all as specified and directed by Engineer-in-Charge.
M&L for Preparing old painted surfaces of steel tubular poles sewaged pole of any description and length not exc 7.5 above ground level erected in vertical position in LT OH line including cross arms of angle iron/ channel section clamps brackets etc with one coat of aluminium paint 6 mtr from top of the pole onward & remaining with black & white paint strip in 30 cm width alternatively upto ground level & numbering the pole with white paint on black paint base 20 cm dia circular/square shape complete all as specified and directed by Engineer-in-Charge.
Restringing of existing LT over head line of ACSR conductor after opening of binding wire from insulator & bringing the sag within limit rebinding the same with insulator with 16 SWG aluminium wire all including renewal of jumpers with providing alkathin pipe of approved quality of jumpers, reconnecting the service connection after removing the carbon material complete all as directed by Engineer in Charge.
M & L for laying connecting and testing of 1100 volts grade LT XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured, heavy duty electric power cable with aluminium conductor of size and type complete all as specified and directed including dismantling and taking down existing old LT cable of any size and type from pole/duct/trench/floor/wall/pipe etc with cable end boxes, glands, bricks etc with necessary disconnection work and keep in safe custody for the following size of cables :- Note:- (i) Excavation and earth work, sand cushioning, bricks & cable protection pipe will be measured & paid under appropriate items of Schedule 'A'
Cable of size 3.5 core 70 Sq mm
Cable of size 3.5 core 95 Sq mm
Cable of size 3.5 core 120 Sq mm
Note:- Schedule of credit Rs. 1,37,422.50 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
M/S RAJ ENGINEERS
RAVI KUMAR
PROACH ASSOCIATES BUILDERS & ENGINEERS
bamral builder
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .