Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical dis qualified |
Tender Value
Refer Docs
EMD Value
₹55,000
Closing Date
11 Feb 2023, 2:00 pmClosed
Executive Engineer JPDCL ED Kathua
Office of the Executive Engineer JPDCL ED Kathua
Electrification Works at KGBVs/GHs on Turnkey Basis falling under the jurisdiction of Electric Division Kathua
2023_PDD_203158_1
KED/43 of 2022-23 Dt.19.01.2023
Open Tender
Electrical Works
Turn-key
60 days
kathua
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Executive Engineer JPDCL ED Kathua
₹55,000
28 Feb 2023
21 Jan 2023
13 Feb 2023
21 Jan 2023
11 Feb 2023
21 Jan 2023
21 Jan 2023 - 26 Jan 2023
Amount
Providing of External Electrical Connection to KGBV Basholi
Creation of 100 KVA Sub Station at KGVB Rehan Basohli on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), conforming to IS 1180(Amendment No.4 March 2021) and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long PCC Pole( WL-300Kg)
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Pre fabricated LT Distribution box
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI wire for Anti Climbing
Cement Bottoming 1:2:4 mix as per REC Standards
3-Phase 4 wire Trivector Meter with CT
Wedge Connector/PG Clamps
Sundary Items
Laying of HT line on 9 Mtrs.PCC poles with ACSR Weasel Conductor at KGVB Rehan Basohli on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9 Mtr. Long PCC Pole(WL-300 Kg )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamp
Anti Climbing Devices with clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Aluminium Jointing Sleeves
Stone Pad (300mmx300 mmx75mm)
Laying of LT line on 8 Mtrs.PCC poles with ACSR Weasel Conductor 3 Phase 4 wire at KGVB Rehan Basohli on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8 Mtr. Long Pole(PCC WL-200Kg )
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Conductor
Galvanized Nuts and Bolts
Danger plates
Anit Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
LT line Spacers
Stone Pad
Alm.Jointing Sleeves
Erection of 11 KV Tapping point at KGVB Rehan Basohlion Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9 Mtr. Long Pole(ST-410 SP-33 )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel/ angle iron including Clamps
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Cement bottoming 1:2:4 Mix as per REC Standars
PG Clamps for 50mm2 ACSR conductor
50mm2 ACSR conductor
Aluminium Paint
Red oxide paint
Providing of External Electrical Connection to KGBV Bani
Creation of 100 KVA Sub Station at KGBV Bani on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), conforming to IS 1180(Amendment No.4 March 2021) and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole(ST-410 SP-33 )
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Pre fabricated LT Distribution box
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI wire for Anti Climbing
Cement Bottoming 1:2:4 mix as per REC Standards
3-Phase 4 wire Trivector Meter with CT
Wedge Connector/PG Clamps
Sundary Items
Red oxcide Paint
Aluminium Paints
Laying of HT line on 9 Mtrs.STpoles with ACSR Weasel Conductor at KGBV Bani on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9 Mtr. Long Pole(ST-410 SP-33 )
GI V cross arms with Top Bracket including ClampsChanel Iron Cross arms
GI Channel X-arm including Clamos and Braces
30 mm² ACSR Conductor
PG clamp for ACSR Weasel conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamp
Anti Climbing Devices with clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Red oxcide Paint
Aluminium Paints
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole
Aluminium Jointing Sleeves
Laying of LT line on 8 Mtrs.ST poles with ACSR weasel Conductor 3 Phase 4 wire at KGBV Bani on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8 Mtr. Long Pole(ST-410 SP-15 )
GI Mukhi-Clamp for Shackle insulators
Shackle insulator 16 KN
30mm² ACSR weasel Conductor
Galvanized Nuts and Bolts
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Red oxcide Paint
Aluminium Paints
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole
Al. Jointing Sleeve
LT line Spacers
erection of 11 KV Tapping point at KGBV Bani on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9 Mtr. Long Pole(ST-410 SP-33 )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel/ angle iron including Clamps
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Cement bottoming 1:2:4 Mix as per REC Standars
PG Clamps for 50mm2 ACSR conductor
50mm2 ACSR conductor
Aluminium Paint
Red oxide paint
Providing of External Electrical Connection to KGBV Macheddi
Creation of 100 KVA Sub Station at KGBV Machaddi (Billawar ) on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), conforming to IS 1180(Amendment No.4 March 2021) and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole(ST-410 SP-33 )
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Pre fabricated LT Distribution box
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI wire for Anti Climbing
Cement Bottoming 1:2:4 mix as per REC Standards
3-Phase 4 wire Trivector Meter with CT
Wedge Connector/PG Clamps
Sundary Items
Red oxcide Paint
Aluminium Paints
Laying of LT line on 8 Mtrs.ST poles with ACSR weasel Conductor 3 Phase 4 wire at KGBV Machaddi (Billawar ) on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8 Mtr. Long Pole(ST-410 SP-15 )
GI Mukhi-Clamp for Shackle insulators
Shackle insulator 16 KN
30mm² ACSR weasel Conductor
Galvanized Nuts and Bolts
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Red oxcide Paint
Aluminium Paints
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole
Al. Jointing Sleeve
LT line Spacers
erection of 11 KV Tapping point at KGBV Machaddi (Billawar ) on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9 Mtr. Long Pole(ST-410 SP-33 )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel/ angle iron including Clamps
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Cement bottoming 1:2:4 Mix as per REC Standars
PG Clamps for 50mm2 ACSR conductor
50mm2 ACSR conductor
Aluminium Paint
Red oxide paint
Providing of External Electrical Connection to 100 Bedded Girls Hostel Basholi
Creation of 100 KVA Sub Station at (Girls Hostel) Basohli on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), conforming to IS 1180(Amendment No.4 March 2021) and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² (1 Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long PCC Pole( WL-300Kg)
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Pre fabricated LT Distribution box
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI wire for Anti Climbing
Cement Bottoming 1:2:4 mix as per REC Standards
3-Phase 4 wire Trivector Meter with CT
Wedge Connector/PG Clamps
Sundary Items
Laying of HT line on 9 Mtrs.PCC poles with ACSR Weasel Conductor at Girls Hostel basholi on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9 Mtr. Long PCC Pole(WL-300 Kg )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamp
Anti Climbing Devices with clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Aluminium Jointing Sleeves
Stone Pad (300mmx300 mmx75mm)
PG Clamps for Weasel Conductor
Laying of LT line on 8 Mtrs.PCC poles with ACSR Weasel Conductor 3 Phase 4 wire at ( Girls Hostel) Basohli on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8 Mtr. Long Pole(PCC WL-200Kg )
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Conductor
Galvanized Nuts and Bolts
Danger plates
Anit Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
LT line Spacers
Stone Pad
Alm.Jointing Sleeves
erection of 11 KV Tapping point at ( Girls Hostel) Basohli on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9 Mtr. Long Pole(ST-410 SP-33 )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel/ angle iron including Clamps
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Cement bottoming 1:2:4 Mix as per REC Standars
PG Clamps for 50mm2 ACSR conductor
50mm2 ACSR conductor
Aluminium Paint
Red oxide paint
MAA BALA SUNDRI ENTERPRISES
M/S MAHALAXMI ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .