| 5 | Rejected-Technical 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | - | Rejected-Technical 2nd cover due to MAF not uploaded nor hard copy submitted even after intimation through shortfall dt 05 Oct 2026 |
| Sl No | Description | Qty | Unit | RUCHIKA ENGG.WORKS L2 | Saini Enterprises L3 | SAMIYA ENTERPRISES L4 | SHALIMAR INTERIORS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing and Commissioning of Double Dome Shadowless OT Light complete with ceiling flange, base tube and ceiling fixed assembly, all as specified and directed by Engineer-in-Charge. The OT light shall be European CE certified and US FDA registered and shall conform to IEC 60601-1 and IEC 60601-2-41 standards for medical electrical equipment with Class-I protection. The system shall consist of one main and one satellite round-shaped light head based on microprocessor controlled Hybrid LED technology with obstruction sensing and depth selection facility. Illumination shall be provided by multiple high performance Hybrid LEDs with illuminance of 1,60,000 Lux or higher using 100–120 LED lamps and light head diameter between 70–80 cm. LED life shall be 60,000 hours or more. External housing shall be made of high-grade ABS plastic resistant to electrical, thermal and chemical effects with efficient heat dissipation ensuring temperature rise not more than 1°C above ambient temperature. The illumination field diameter shall be adjustable from 18–35 ±1 cm with variable colour temperature from 3600K to 5500K ±100K and Colour Rendering Index (CRI) Ra/R9/R13 of 99 or better. Light depth shall be 65–120 cm with intensity control from 25% to 100%. Light head suspension shall be fully cardanic and shall not interfere with OT laminar airflow system, complying with DIN 1946-4 standards having turbulence intensity of 13–14%. The system shall have Endo Light facility for laparoscopic surgery with dim illumination range from 1600–16000 Lux. Shadow dilution performance shall be 95% with tube, 90% with one mask, 65% with two masks, 85% with one mask at base of tube and 60% with two masks at base of tube.>>>
Make: Luvis / Stryker / Drager/ Hospedia | 2 | Each Job | 24,00,000 ₹48,00,000 | 24,50,000 ₹49,00,000 | 24,70,000 ₹49,40,000 | 22,99,999 ₹45,99,998 Lowest |
| 1.01>>>The fitting shall have minimum ingress protection IP42 with radiation energy not exceeding 3.7 mW/m²/lx and illumination energy 550 W/m² ±10. The system shall be provided with sterilizable handle and touch-sensitive arm control for adjustment of illumination field, intensity, colour temperature and depth of light including synchronization of both light heads. SMPS shall be of 28V DC capacity and complete system shall include remote cordless tablet PC for changing operating parameters and integrated/external UPS suitable for minimum one hour backup. | |||||||
| 1.02>>>The above OT light must comprises of camera which should be mounted on light head for displaying real time images during surgery with a coaxial camera chip of 1.28 CMOS or more than with 2.10 Megapixels capability with atleast 12X Digital Zoom and 30X Optical Zoom. 4K (3840x2160) image capture and external recording. Camera control should have function like Zoom In/Out, White balance, Focus In/Out, Auto, Aperture In/Out, Freeze. All Function of HD Camera should be controllable through Android Tablet PC/ Voice control & Touch Panel. It should be in 4K: (3840x2160) pixels/ 60 frames/ Sec. Minimum Object distance 10mm to 1200mm or as applicable. Focal length 4.3 to 129mm. Shutter speed 1/1-1/10000 (22 Steps). Signal Noise ratio 50DB. Output 3G HD-SDI, SMPTE 424M and 292M. Light and Integrated Camera should have a control through Touch Panel of the control equipment placed inside the operating room. Note for Item No.1: (i) The Contractor shall submit a Manufacturer's Authorization Form (MAF) from the OEM of OT light, covering all warranties, alongwith the Technical Bid. (ii) The Sample Proforma of Manufacturer's Authorization Form (MAF) is given in tender as Annex 'A'. | |||||||
| 2.00 | M & L for Sub-Main Wiring with 2 runs of 4 Sqmm FRLS, PVC insulated, unsheathed, stranded copper conductor cable (ISI marked) drawn through PVC conduit of suitable size including all conduit accessories, together with 1 run of 4 Sqmm FRLS copper cable as earth continuity conductor, complete with thimbles, lugs, terminations and connections from Main DB/Panel to Double Dome Shadowless OT Light etc, including chasing/fixing of conduit in wall, ceiling or slab as required and making good disturbed surfaces with cement mortar (1:4) to match existing finish, complete in all respects as specified and directed by Engineer-in-Charge. | 36 | RM | 350 ₹12,600 | 450 ₹16,200 | 400 ₹14,400 | 299 ₹10,764 Lowest |
| 3.00 | M & L for carefully dismantling/removing existing gypsum false ceiling including framework, suspension arrangements, screws, fittings and accessories at required locations for installation/fixing of Double Dome Shadowless OT Lights, without causing damage to adjoining ceiling surfaces and services. The work shall include cutting/opening of ceiling wherever required, temporary stacking of dismantled materials, refixing/reinstallation of existing false ceiling after completion of OT light installation and providing additional/new gypsum false ceiling wherever damaged or not reusable, including GI framework, hangers, perimeter channels, jointing, finishing, screw fixing, cutting for light fixtures and all necessary accessories. The work shall also include making good disturbed surfaces, finishing joints with approved jointing compound, sanding and matching existing texture/finish including painting/touch-up to match existing ceiling appearance, complete in all respects as specified and directed by Engineer-in-Charge. | 15 | SQM | 1,100 ₹16,500 | 1,200 ₹18,000 | 999 ₹14,985 Lowest | 1,999 ₹29,985 |
Tender Value
₹44.2 L
EMD Value
₹88,500
Closing Date
28 Sept 2026, 6:00 pmClosed
GE E/M RR HOSP DELHI CANTT-10
GE E/M RR HOSP DELHI CANTT-10
GE/H/T-26/2026-27 PROVN OF SHADOWLESS OT LIGHT FOR BURN CENTRE AND LABOUR ROOM AT AHRR UNDER GE E/M R AND R HOSP DELHI CANTT-10
2026_MES_775244_2
GE/H/T-26/ 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M RR HOSP DELHI CANTT-10
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE E/M RR HOSP DELHI CANTT-10
₹88,500
Yes
15 Oct 2026
4 Aug 2026
30 Sept 2026
4 Aug 2026
28 Sept 2026
14 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of Double Dome Shadowless OT Light complete with ceiling flange, base tube and ceiling fixed assembly, all as specified and directed by Engineer-in-Charge. The OT light shall be European CE certified and US FDA registered and shall conform to IEC 60601-1 and IEC 60601-2-41 standards for medical electrical equipment with Class-I protection. The system shall consist of one main and one satellite round-shaped light head based on microprocessor controlled Hybrid LED technology with obstruction sensing and depth selection facility. Illumination shall be provided by multiple high performance Hybrid LEDs with illuminance of 1,60,000 Lux or higher using 100–120 LED lamps and light head diameter between 70–80 cm. LED life shall be 60,000 hours or more. External housing shall be made of high-grade ABS plastic resistant to electrical, thermal and chemical effects with efficient heat dissipation ensuring temperature rise not more than 1°C above ambient temperature. The illumination field diameter shall be adjustable from 18–35 ±1 cm with variable colour temperature from 3600K to 5500K ±100K and Colour Rendering Index (CRI) Ra/R9/R13 of 99 or better. Light depth shall be 65–120 cm with intensity control from 25% to 100%. Light head suspension shall be fully cardanic and shall not interfere with OT laminar airflow system, complying with DIN 1946-4 standards having turbulence intensity of 13–14%. The system shall have Endo Light facility for laparoscopic surgery with dim illumination range from 1600–16000 Lux. Shadow dilution performance shall be 95% with tube, 90% with one mask, 65% with two masks, 85% with one mask at base of tube and 60% with two masks at base of tube.>>> | 2 | Each Job | - | - |
| 1.1 | >>>The fitting shall have minimum ingress protection IP42 with radiation energy not exceeding 3.7 mW/m²/lx and illumination energy 550 W/m² ±10. The system shall be provided with sterilizable handle and touch-sensitive arm control for adjustment of illumination field, intensity, colour temperature and depth of light including synchronization of both light heads. SMPS shall be of 28V DC capacity and complete system shall include remote cordless tablet PC for changing operating parameters and integrated/external UPS suitable for minimum one hour backup.
Make: Luvis / Stryker / Drager /Ascentech. | - | - | - | - |
| 2 | M & L for Sub-Main Wiring with 2 runs of 4 Sqmm FRLS, PVC insulated, unsheathed, stranded copper conductor cable (ISI marked) drawn through PVC conduit of suitable size including all conduit accessories, together with 1 run of 4 Sqmm FRLS copper cable as earth continuity conductor, complete with thimbles, lugs, terminations and connections from Main DB/Panel to Double Dome Shadowless OT Light etc, including chasing/fixing of conduit in wall, ceiling or slab as required and making good disturbed surfaces with cement mortar (1:4) to match existing finish, complete in all respects as specified and directed by Engineer-in-Charge. | 36 | RM | - | - |
| 3 | M & L for carefully dismantling/removing existing gypsum false ceiling including framework, suspension arrangements, screws, fittings and accessories at required locations for installation/fixing of Double Dome Shadowless OT Lights, without causing damage to adjoining ceiling surfaces and services. The work shall include cutting/opening of ceiling wherever required, temporary stacking of dismantled materials, refixing/reinstallation of existing false ceiling after completion of OT light installation and providing additional/new gypsum false ceiling wherever damaged or not reusable, including GI framework, hangers, perimeter channels, jointing, finishing, screw fixing, cutting for light fixtures and all necessary accessories. The work shall also include making good disturbed surfaces, finishing joints with approved jointing compound, sanding and matching existing texture/finish including painting/touch-up to match existing ceiling appearance, complete in all respects as specified and directed by Engineer-in-Charge. | 15 | SQM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
BOQ_876838.xls
BOQ • 0.32 MB
T26Tender.pdf
Tender Documents • 1.15 MB
corr04t26.pdf
PDF • 0.69 MB
Corr03.pdf
PDF • 0.37 MB
Corr02.pdf
PDF • 0.37 MB
Corr02.pdf
PDF • 0.37 MB
T26corr01.pdf
PDF • 0.37 MB
T26corr01.pdf
PDF • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .