Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹36.9 L+₹51,940 (1.43%)Rejected-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L2 | Rejected-AOC not found lowest | |
| 3 | L3₹38.7 L+₹2.3 L (6.45%)Rejected-AOC VILL NAYA GUGNAN PO SUJANPUR TEH DISTT PATHANKOT 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L3 | Rejected-AOC not found lowest | |
| 4 | L4₹38.8 L+₹2.4 L (6.61%)Rejected-AOC C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L4 | Rejected-AOC not found lowest | |
| 5 | L5₹43.4 L+₹7.1 L (19.4%)Rejected-AOC | L5 | Rejected-AOC not found lowest |
Tender Value
Refer Docs
EMD Value
₹84,300
Closing Date
25 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Basoli
GE Basoli PO lakhanpur Distt Kathua JK
SPECIAL REPAIR OF BLDG NO P-1 2 and 3 OFFERS MESS SERVANT QTR AND NP1, 2 and 3SERVANT BATHROOM and TOILET OF 510 LT AD MSL REGT SP AND PROVN OF SOKAGE WELL WITH SEPTIC TANK NEAR BLDG NO P-70JCO LIVING ACCN,P-88 OR LIVING ACCN AND P-80 ADM BLOCK OF 95
2022_MES_554615_1
GE/BAS-52/2022-23
Open Tender
Civil Works
Item Rate
150 days
Madhopur under GE Basoli
class D catg a(I)
7 documents required · 7 mandatory
₹500
Yes
GE Basoli
₹84,300
Yes
7 Jan 2023
27 Sept 2022
27 Oct 2022
27 Sept 2022
25 Oct 2022
11 Oct 2022
Amount
M&L for RCC Septic tank 100 users conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. Ref drg no CEPZ/STD-199/20 sht 1/2 & 2/2 dt 16-11-2020
M&L for RCC Septic tank 50 users conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users Ref drg no CEPZ/STD-199/20 sht 1/2 & 2/2 dt 16-11-2020
M&L for construction of septic tanks, exc, in ordinary soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame vent shaft and sludge chambers etc., complete for 50 users . Ref Drg no CEPZ/TD/013/13 Sht 1/5 to 5/5
M&L for construction of soakage well, 3.00 m dia and 4.50 m depth below inlet pipe (depth of inlet pipe 45cm below normal ground) including excavation and earth work in any type of soil, cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate in foundation, brick work in CM 1:4, RCC M-25 (Design Mix) Cover slab, manhole cover with angle iron frame, appropriate and suitable size brick bat filling, SWG junction 150mm bore CI vent pipe and Cowl etc. complete all as specified and as shown on drawings. Ref Drg no CEPZ/TD/013/13 Sht 1/5 to 5/5
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n. exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in, any type of soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil, complete all as specified and as directed.
Removing excavated material (soils) to a distances exc 50 m and and not exceeding 100m depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and as directed.
M&L for Concrete bed to drain pipes laid to falls including packing under and completely surrounding of pipe after they are laid and tested in cement concrete 1:4:8 for 150mm bore pipes, complete all as specified and as directed. NOTE:- (i) Thickness of bed below the barrel of pipe shall be 100mm and width of bed shall be 300mm plus of outer dia meter of drain pipe(not of socket/collars) (ii) Unit rate includes necessary shuttering /form work as required.
M&L for RCC pipe, class NP-3 for 150 mm bore laid and jointed concrete bed, complete including testing etc all as specified and shown on drawing(Concrete bed shall be assured and paid separately) complete all as specified.
M&L for Cement concrete in foundations, filling and mass concrete type D-2, 1:4:8 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed.
M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed.
M&L for Pre cast cement concrete C1,1:2:4 (using 20 mm graded stone aggregate) as in landings, cover slabs, (for manholes etc.) chullah hoods, chajjas, water trough,mangers, shelves and similar articles with plain faces, complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces using cement plaster 1:4 finished even & smooth without using extra cement, complete all as specified and as directed.
M&L for Cement concrete M-15(Nominal Mix) type B-1 using 20mm graded crushed stone aggrgates as in coping,benching including weathering slightly rounded or chemfered angles and finishing exposed surfaces even and smooth including use and waste of necessary form work and finishing all exposed surfaces, complete all as specified and as directed.
Taking down steel window & ventilator with wire mesh/glazed shutter (Without taking of shutter from frame) area n exc 1.50Sqm each, complete all as specified and as directed.
Taking down chowkat with shutter (Without taking of shutter from frame) area exceed 1.50 Sqm but not exceed 4.00 Sqm each, complete all as specified and as directed.
Demolition of cement concrete (un reinforced )in ground floors and paving n exc 15 cm thickness (below or above ground level)complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises of MD land, complete all as specified and as directed.
Dismantling of water tank of capacity exc 500 but not exc 1000 ltr from roof slab, complete all as specified and as directed.
Taking up or down steel tubing and connections of 15mm bore dia of pipe, complete all as specified and as directed.
Taking up or down steel tubing and connections of 20mm bore dia of pipe, complete all as specified and as directed.
Taking down cement plaster on brick or stone walls or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with, water etc , complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L Brick work with sub class `B' bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:6 complete all as specified and directed.
M&L rendering 15 mm thick on brick walls with CM 1:6, finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for rendering 15 mm thick in CM (1:4) on brick work or concrete masonry wall surface finished even and smooth with out using extra cement mixed with water proofing compound.( WPC shall be measured and paid separately), complete all as specified and as directed.
Supply only integral Water Proofing Compound, complete all as specified and as directed.
M&L for rendering 10 mm thick in CM (1:3) finished even and smooth in ceiling without using extra cement, complete all as specified and as directed.
M&L for rendering 10 mm thick in CM (1:4) on concrete surface for receiving and fixing of skirting/dado tiles in vertical surfaces, complete all as specified and as directed.
M&L for screed bed or bedding of layer 15 mm thick in CM (1:6) for laying of floor finishes, complete all as specified and as directed.
M&L for 25mm thick cement concrete type B0 1:2:4 using (12.5 mm graded stone aggregates) as in flooring, complete all as specified and as directed.
M&L for Non-skid Ceramic coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but n . Exc 0.18 sqm ,in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match shade complete all as specified and as directed.
M&L for Non-skid Ceramic coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.18 sqm but n . Exc 0.36 sqm ,in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match shade complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles in vertical surface 450mmx350mmx7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed.
M&L 75 mm thick 1:3:6,Type C-2 (using 40mm graded agg) in plinth protection etc.laid in alternate bays all complete and as specified.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube as specified and drawing.
S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of M.S tube for top & bottom rails M.S. frame shall be covered with heat molded wood plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheet as for top rail lock rail & bottom rail on either side,complete all as specified and as directed.
S&F 35mm thick IInd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated
M&L for Pressed steel frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike mate etc complete of size 105x60mm Complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in back filling of chowkats Complete all as specified and directed.
M&L Box type steel windows and ventilator comprised of tubular frame and shutters made out of 1.25mm thick MS Sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes only shall be measured and paid seperately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 150mm long for each leaf and 10mm square bar grills at spacing shown on drg welded to GI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F Galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples, complete all as specified and as directed.
S&F sheet glass ordinary quality 3mm thick with oil putty in area n.exc 0.5 Sqm in each pane, complete all as specified and as directed.
S&F figured pin headed glass 3mm thick with oil putty in area n.exc 0.5 Sqm in each pane, complete all as specified and as directed.
S&F 100mm butt hinges, medium weight, cold rolled mild steel, complete all as specified and as directed.
S&F for 150mm long aluminum, anodized, barrel tower bolts of extruded section and fixed, complete all as specified and as directed.
S &F mild steel sliding door bolts plate type stove enameled black with bright bolts not less than 12mm dia with including a minimum of 6 bolts nut four on bolts plate & two on staple plate of 300 mm long, complete all as specified and as directed.
S&F for 150mm long aluminum handles, cast type, anodized, complete all as specified and as directed.
S&F rotational molded polyethylene water storage tank (Cylindrical vertical with closed tip) of 1000 ltrs hoisted and fixed in position all as specified and directed in SSR-Part-I on roof, complete all as specified and as directed.
Supply and fixed gun metal gate valve 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed.
Supply and fixed ball brass valve, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule all as secured and directed 20mm bore, complete all as specified and as directed.
Supply & Fixed 15mm bore dia of tubing with screwed socket joints, medium grade galvanized steel with all necessary tube fittings and fixing complete with clips, wall hooks etc to wall and ceilings or laid in floor including necessary changing and cutting in brick/concrete surfaces and making good the disturbed surface complete in CM 1:4, complete all as specified and as directed.
Supply & Fixed 20mm bore dia of tubing with screwed socket joints, medium grade galvanized steel with all necessary tube fittings and fixing complete with clips, wall hooks etc to wall and ceilings or laid in floor including necessary changing and cutting in brick/concrete surfaces and making good the disturbed surface complete in all respect as specified.
S&F in repair, Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including plastic seat cover , white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and jet spray, complete all as specified and as directed.
S&F PVC flushing cistern low level ,10 lit. cap. With it’s complete accessories, fixed complete incl. connection to water pipe and seat, complete all as specified and as directed.
S&F in repair aluminium anodised tubular towel rails 20mm dia D type 60cm long between flanges alongwith brackets, complete all as specified and as directed.
S&F in repair 15 mm bore CP fancy type bib Taps with flange cast copper alloy with crutch or butterfly handle, screwed down , screwed for iron pipe, complete all as specified and as directed.
S&F in repairs 15 mm dia stop valves/angle valve , cast copper alloy,chromium plated screwed down, high pressure with crutch or butterfly handle, screwed for iron pipe in repair, complete all as specified and as directed.
S & F PVC connections 15 mm with PTMT nuts of length 450 mm, complete all as specified and as directed.
M& L cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone agg) of uniform thickness 50mm , top surface of plain concrete padding shall be finished even & fair w/o using extra cement complete all as specified and directed.
M&L for roof treatment with the following specicification - (a) Removal of existing old treatment of any type and roughening surfacesof old concrete of picking sweeping and washing down with water (b) applying evenly one coat of blown hot bitumen of grade 85/25 @ 1.2 kg per sqm on primed surfaces. (e) Applying a layer of APP based polymeric membrane 3mm thick (minimum) weighting 3.5 kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160 gms per sqm top of membrane with mineral gravel finish. The overlap shall be minimum 100mm on transverse direction and 75 mm on longitudinal direction and sealing overlap by torch application . NOTE:- The work shall be executed by contractor through authorised applicator of manufacturer firm.
M &L for preparation new or previously untreated wood surface not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paints over a coat pink primer, complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coat of Synthetic enamel paint over a red oxide etc, complete all as specified and as directed.
M&L Applying two coats of oil bound distemper with priming coat on plastered and other surface with alkali resistant priming paint of any colour or tint over a coat of putty including preparation of newly plastered surfaces of walls complete all as specified as directed.
M&L for preparation of new plastered surface and applying three coats of white wash on ceiling, complete all as specified and as directed.
M&L for preparation of new plastered surface and applying three coats of white wash on wall, complete all as specified and as directed.
M&L preparation new plastered surfaces of walls and applying two coats of cement base paint over priming plastered and other surface with alkali resistant priming paint all as specified and directed.
S&F Curtain rod 20mm dia of ms powder coated with incl PVC brackets , Stops, rollers etc. Complete all as specified and directed.
M&L Machine pressed precast coloured conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness , M-40 Grade with Grey cement and pigment, complete all as specified and as directed.
M&L for Sand filling under foundation including watering and consolidation for fixing the interlocking pavers blocks, complete all as specified and as directed.
S&F in repair Vitreous China urinals, Half stall type, white, with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement; fixing with flush pipe, grating and Union for discharge pipe. includinng provn of push type flushing system complete all as specified and directed.
S&F in repair Vitreous china wash basin white , flat back size 550 X 400 mm including brackets including cutting for and pinning in ends of brackets or erecting stand including PTMT 32mm waste coupling and waste pipe, complete all as specified and as directed.
S&F in repair Pillar tap cast copper alloy fancy type with capstan heads, chromium plated Fancy type screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long shanks and nut screwed for iron pipe of 15 mm bore, complete all as specified and as directed.
S&F cast iron soil, waste and vent pipes in any length with or without ears, with cement joints laid in trenches or in floor, 100mm dia, sand cast pipes, complete all as specified and as directed.
S&F cast iron soil, waste and vent pipes in any length with or without ears, with cement joints laid in trenches or in floor, 75mm dia, sand cast pipes, complete all as specified and as directed.
S&F 100 mm dia Bends (any radius) diminishing pieces or tapers (larger bore measured), complete all as specified and as directed.
S&F 75 mm dia Bends (any radius) diminishing pieces or tapers (larger bore measured), complete all as specified and as directed.
S&F cast iron trap 'P' or 'S' 100 mm, fixed in position , complete all as specified and as directed.
S&F 100mm dia Bends (any radius) with duck's foot or heel rest, complete all as specified and as directed.
S&F cast iron soil, waste and vent pipes in any length with or without ears, with cement joints fixed to walls, 75mm dia, sand cast pipes including two coats of black Japan paint, complete all as specified and as directed.
S&F cast iron floor trap 75 mm, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4), complete all as specified and as directed.
Taking down old damaged SGSW pipes including necessary excavation, supply and jointing of UPVC underground drainage pipe (UDS) type 'B' 160mm dia with thickness 4mm (min) and pressure rating SN4 as per IS-15328, jointed in cement solvent solution complete including testing, haunching against the sides of pipes in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) including returning, filling in and disposal of surplus soil to a distance n.exc. 50m complete all as specified and as directed.
M&L for Providing, cement concrete 1:2:4 type B1, using 20mm graded stone aggregate in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rouinded for chamfered angles and throating, complete all as specified and as directed.
M&L 75mm thick cement conc type C-2 1:3:6 (40mm graded stone agg) finished even and fair, complete all as specified and as directed.
S&F stop valve cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe with long shank chromium plated concealed type, complete all as specified and as directed.
S&F in repairs 125mm size brass chromium plated shower rose with swivel joints, complete all as specified and as directed.
S& F aluminium Peg set of six hooks size 50mm to 60mm, complete all as specified and as directed.
S&F in repair vetreous China squatting pan Orissa pattern size 580 x 440mm white with integral foot rest ( excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anty syphonage pipe etc. complete incl making good to floor all as specified.
S & F in rolled mild steel Fe-410-W(Gde-E-250) quality -B Roof trusses (framed) trussed,purlins,crane gantries,rails and fastening and heavy bracket framing(Beam,tee,angle,channel or flat sections)including distance pieces,cleats etc including red oxide and two coat of synthetic enamel paint all as specified and directed
M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Point wiring with 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable in and incl rigid PVC conduit concealed with pressed mild steel terminal boxes duly painted with a coat of red oxide primer with suitable thickness plastic laminated sheet cover of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed by Engr-in-charge. Note: a) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc (b) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan etc with proper fixing clips all as directed
All as per item No 94 but for one 3 pin 5 Amp socket outlet on independent board.
All as per item No 94 but for one 3 pin 5 Amp socket outlet on same board.
Point wiring with 2.5 sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable drawn in and including rigid PVC concealed conduit medium grade of suitable size with sunk cast iron/pressed steel terminal boxes of adequate size with suitable thickness plastic laminated sheet cover for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm FRLS,PVC insulated and unsheathed copper conductor cable (multistranded) as earth wire to common earth dolly, complete all as specified.
S&F switch piano flush button single pole one way 5 amps 230 volts,complete all as specified and directed by Engr-in-Charge.
S&F switch piano 15 amps flush type single pole one way suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet flush type 5 pin 6 amps suitable for 240 volt AC Complete all as specified and directed.
S&F socket outlet 2 in 1, 5 pin 15 amps flush type suitable for 240 volt AC Complete all as specified and directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings complete
S&F ceiling rose surface bakelite two to three terminal isolated body fixed on PVC round block complete all as specified.
Supply & fix Fan Regulator, 220V, Switch type dimmer, complete all as specified and directed.
S& F LED Lamp 9 watt , Complete all as specified and directed.
S&F in replacement LED tube light fitting. ,1x20w, 220v AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
M&L 25 watt LED Street light/ Bldg Security light fitting of IP-66 protection, pressure die cast aluminium housing with epoxy powder coated finish having polycarbonate cover with all accessories pre-wired with and including light grade GI pipe bracket for fixing on pole/ angle iron bracket for fixing on wall as required & connecting up with three core flexible copper conductor cable of size 1.0 Sqmm complete all as specified and as directed
S&F in replacement sheet metal powder enclosure powder coated double door SPN 8, way having provision for one No incoming MCB SPN and out going MCBs SP AC 230 Volts, 50 HZAC supply having protection IP 43, IK-09 with copper bus bar rated 200 Amps, neutral link,earth bar complete all as specified. Make: Legrand/L & T/polycab any other make as per list circulated by HQWC. Note :- MCBs shall be paid separatly
S&F in replacement MCBs isolator 40 Amps, 240 Volts, 10 KA breaking capacity of C series all as specified.
S&F in replacement MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards all as specified.
S&F in replacement sheet metal powder enclosure powder coated double door SPN 4, way having provision for one No incoming MCB SPN and out going MCBs SP AC 230 Volts, 50 HZAC supply having protection IP 43, IK-09 with copper bus bar rated 200 Amps, neutral link,earth bar complete all as specified. . Note :- MCBs shall be paid separatly
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust , common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thick RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including testing on completion. (Note: The rate quoted include cost of min 7.5 metre earthing wire .)
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sqmm 2 core.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5mtr in depth for foundation of pole/ stay and laying of UG cable and getting out in any type of soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5mtr above the starting point complete all as directed.
Supply & laying of approved quality sand under cable upto 15cm before laying the cable and 8cm over the cable after laying, punned down to overall thickness of 18cm in trenches for cable cushioning all as specified and directed.
M&L Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified .
Supply and laying in trenches tubes medium grade galvanised 25mm dia with all fitting such as tee bend elbow union socket etc complete all as specified and directed.
S&F gate valve 25 mm dia gun metal gate valve conforming to IS with iron wheel head screwed both ends for iron pipe all as specified and directed.
R K Builders
Substantial Const. Co.
Shiva Builders
Standard engineers
Sandeep Kumar
M/S SHRI RAM BUILDERS
RATTAN CHAND CHANDAN AND CO
KULBHUSHAN AGGARWAL
SATISH AND CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .