Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC SUPER PLAZA AMRITSAR PUNJAB 143001 INDIA | AMRITSAR | PUNJAB | 143001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.2 L+₹2.2 L (7.87%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Quoted other than lowest rate. | |
| 3 | L3₹30.3 L+₹2.4 L (8.46%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate. | |
| 4 | L4₹31.6 L+₹3.6 L (12.8%)Rejected-Finance | L4 | Rejected-Finance Quoted other than lowest rate. | |
| 5 | L5₹32.1 L+₹4.2 L (14.9%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate. |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
24 Feb 2024, 6:00 pmClosed
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA Pin-151004
ADDN/ALTN TO OLD TYPE ALUMINIUM POINT WIRING WITH COPPER POINT WIRING, MODULAR SWITCH, SOCKET, OUTDATED TYPE FITTINGS AND FIXTURES, EARTHING, DB AND CONNECTED ACCESSORIES AT KV NO - 04 , PROVN OF FLAME PROOF LIGHTING AN WIRING AT BATHINDA MIL STN
2023_MES_632019_1
8938/NIT-67/23-24
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
BATHINDA
Class D category b(i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹74,000
Yes
23 Mar 2024
9 Dec 2023
26 Feb 2024
9 Dec 2023
24 Feb 2024
19 Jan 2024
9 Dec 2023 - 15 Dec 2023
Amount
SCHEDULE 'A' E/M Works
Taking down carefully/aluminium point wiring (light, fan, socket or power point ) complete including fitting such as hylem sheet switches, ceiling rose, pendent holder sockets, regulator except concealed conduit and sunken boxes etc and making good distrubed surfaces of wall and floors etc to match with the existing, complete all as specified and directed by Engineer-in-charge.
M & L for point wiring complete modular type with 1.5 sqmm (nominal cross section area ) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked ) drawn through and including PVC rigid conduit 20mm dia( heavy duty ) with all fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken boxe of suitable for mounting modular switches and sockets , fan regulator, for light/fan point controlled by one switch, top cover fixed with brass screws & cup washers including provn of 1.5 sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly , and provision of suitable module plate ,plate cover etc including cutting chases in wall and making good distrubed surface of wall/ceiling/floors etc by using CM (1:3 ) to matching with existing surface complete all as specified and as directed by Engineer-in-charge. Note:- Whereever the wall surfaces disturbed due to cutting of wall for insertion of conduit that wall to be finished with cement mortar and putties as per matching of existing colour and cement work included in the quoted rate.
All as per item No 2 here in before but for socket outlet 5 pin 5/6 Amp on same board, complete all as specified and directed by Engineer-in-charge.
All as per item No 2 here in before but for socket outlet 5 pin 5/6 Amp on independent board but not below the switch board, complete all as specified and directed by Engineer-in-charge.
All as per item No 2 here in before but for socket outlet 6 pin, 15/16 Amp multi purpose, 2 in 1 on independent board with 2.5 Sqmm cable & including 2.5 sqmm single core multi stranded FRLSH copper earth wire to common earth, complete all as specified and directed by Engineer-in-charge.
All as per item No 2 here in before but for one flood light controlled point wiring 2.5 Sqmm cable & including 2.5 sqmm single core multi stranded FRLSH copper earth wire to common earth, complete all as specified and directed by Engineer-in-charge.
All As per item No 2 in before but for bell/buzzer point, complete all as specified and directed by Engineer-in-charge.
All As per item No 2 in before but for one light point controlled by Two Two way switch, complete all as specified and directed by Engineer-in-charge.
Supply and fixing modular Switch 1 way 6A ,1 module 250 volts AC one way ISI, marked model fantasy with suitable frame and covers with matching colours, complete all as specified and directed by Engineer-in-charge.
Supply and fixing modular Switch 1 way 16 A,1 module 250 volts AC ISI marked , model fantasy with suitable frame and covers with matching colours, complete all as specified and directed by Engineer-in-charge.
Supply and fixing modular Socket 6 A-2/3 pin combined 2 module shuttered 250 volts AC ISI, marked model fantasy with suitable frame and covers with matching colours, complete all as specified and directed by Engineer-in-charge.
Supply and fixing modular Socket 6A/16A-2/3 pin combined,2 module 250 volts AC shuttered ISI marked, model fantasy with suitable frame and covers with matching colours, complete all as specified and directed by Engineer-in-charge.
Supply and fixing modular Bell push, piano flush type, 6 amp 250 Volts, with suitable frame and covers with matching colours, complete all as specified and directed by Engineer-in-charge.
Supply and fixing modular Switch 2 way 6A, 1 module 250 volts AC ISI marked, model fantasy with suitable frame and covers witch matching colours, complete all as specified and directed by Engineer-in-charge.
Supply and fixing ceiling rose 3 phase flush type 6 Amp 250V AC topline series with polycarbonate 20 X 50 mm two to three terminal, complete all as specified and directed by Engineer-in-charge.
Supply and fixing modular type stepped type electronic fan regulator flush type on existing sheet, complete all as specified and directed by Engineer-in-charge.
Supply and fixing Electric / Electronic Bell, music type 230 Volt AC supply, complete all as specified and directed by Engineer-in-charge.
Supply and fixing Lamp holder of PVC/Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb, complete all as specified and directed by Engineer-in-charge.
Supply and fixing squire profile Batten decorative type wall mounted LED 20 watt, white flux, , appx 4 feet long, pre wired , 6000K with inbuilt driver complete fitting and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED mirror light fiting 9/ 10 watt, 6000K, lineer & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete fitting with lamp and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector, complete all as specified and as directed by Engineer-in-Charge.
S &F building security light IP 66 luminaire with high power LED of 25 watt with toughened glass complete with suitable GI for security light fitting fixing to wall/column & electrical connection to the light fitting providing 1.5 mtr long twin core round copper conductor cable of suitable size and testing complete all as specified and directed.
Material and labour for Sub main wiring complete with four single core 10 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH with continuous copper earth conductor one run of of 10 sqmm in including PVC concealed conduit including taking down old unserviceable submain wiring including GI conduits, complete all as specified and directed by Engineer-in-charge. Note:- Four run of wire consider in 1 Mtr and whereever the wall surfaces disturbed due to cutting of wall for insertion of conduit that wall to be finished with cement mortar and putties as per matching of existing colour and cement work included in the quoted rate.
Material and labour for Sub main wiring complete with two single core 6 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH with continuous copper earth conductor of one run of 6 sqmm in including PVC concealed conduit including taking down old unserviceable submain wiring including GI conduits, complete all as specified and directed by Engineer-in-charge. Note:- Three run of wire consider in 1 Mtr and whereever the wall surfaces disturbed due to cutting of wall for insertion of conduit that wall to be finished with cement mortar and putties as per matching of existing colour and cement work included in the quoted rate.
Material and labour for Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH with continuous copper earth conductor of one run of 4 sqmm in including PVC concealed conduit including taking down old unserviceable submain wiring including GI conduits, complete all as specified and directed by Engineer-in-charge. Note:- Three run of wire consider in 1 Mtr and whereever the wall surfaces disturbed due to cutting of wall for insertion of conduit that wall to be finished with cement mortar and putties as per matching of existing colour and cement work included in the quoted rate.
Supply and fixing metal enclousers made out of CRCA mild steel sheet, double door, powder coated DB Vertical TPN 8 way 415 Volt,(concealed in wall or as directed) dust and vermin proof suitable for incorporation of MCCB's upto 125Amp and isolators etc., including taking down unserviceable old DB any type etc. complete all as specified and directed by Engineer-in-charge. Note:- Whereever the wall surfaces disturbed due to cutting of wall for insertion of DBs and conduit that wall to be finished with cement mortar ,bricks and putties as per matching of existing colour and cement work included in the quoted rate.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type etc. and including making good disturbed surfaces of walls as necessaty, complete all as specified and directed by Engineer-in-charge. Note:- Whereever the wall surfaces disturbed due to cutting of wall for insertion of DBs and conduit that wall to be finished with cement mortar ,bricks and putties as per matching of existing colour and cement work included in the quoted rate.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 4 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type etc. and including making good disturbed surfaces of walls as necessaty, complete all as specified and directed by Engineer-in-charge. Note:- Whereever the wall surfaces disturbed due to cutting of wall for insertion of DBs and conduit that wall to be finished with cement mortar ,bricks and putties as per matching of existing colour and cement work included in the quoted rate.
Supply and fixing AC connection Box (Concealed with wall) single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 25 Amps, 240 volts,, complete all as specified and directed by Engineer-in-charge. Note:- Whereever the wall surfaces disturbed due to cutting of wall for insertion of DBs and conduit that wall to be finished with cement mortar ,bricks and putties as per matching of existing colour and cement work included in the quoted rate.
Supply and fixing MCCB of capacity 125 Amp, FP, 415 volt, short circuit breaking capacity not less than 16KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc , MCCB fixing in new DB or the existing DB/Panel including making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge . Note :- DB shall be measured and paid separately under appropriate item of BOQ of above item.
Supply and fixing MCB SPN 63 Amps, 10 KA 'B' curve 230 V AC, 50 Hz including necessary attachment including taking down old unserviceable MCB SPN, complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB SP suitable for 230 volts AC supply 6 to 32 Amps, SP rupturing capacity not less than 10KA,' B' Curve ISI Marked, 1 Module including taking down old unserviceable MCB SP, complete all as specified and directed by Engineer-in-charge.
Supply and fix of exhaust fan 250mm sweep made of study engineering plastic complete with louvers ,voltage 230V,50Hz,RPM 1200 copper winding of sweep 250mm and making suitable hole on wall and its finishing of cement work all included in the item rate all as specified and directed by Engr-in- Charge
Supply and fix of exhaust fan 300mm sweep made of study engineering plastic complete with louvers ,voltage 230V,50Hz,RPM 1200 copper winding of sweep 300mm and making suitable hole on wall and its finishing of cement work all included in the item rate all as specified and directed by Engr-in- Charge
Taking down ceiling fan from site and keep in safe custody /store for reuse the same location after the wiring work. Before install the same will be new spray painted as per existing coy made colour all as directed.Note:- If any damages of fan and its connected acessories at the time of transportation and dismantling the contractor will response to be repair /replace all as per existing size and make.
Hanging only ceiling fan after completion of wiring work refixing the same location (the item retrieved from item No 34 Above).Provision of connection wires and fixing arrangements are included in the quoted rate and fan must be refix after spray painting work all as directed.
Supply and fixing internet cable Cat 5 e & wires and fixing arrangements including suitable PVC conduit and laying arrangements as per advice from the principal KV No4 and as directed by Engr-in- charge. Note :- Type of cable - A Cat 5e cable is the current standard. This standard Ethernet cable is able to support internet plans with speed up to 1000 Mbps and helps get rid of unwanted transfer of signal between the cables to a stronger connection.
Supply and fixing loud speaker connection cable 16, gauge, (4 AWG) suitable for existing amplifier capacity 500-1000 watts RMS including its laying arrangements and PVC as per advice from the principal KV No4 and as diected by Engr-in- charge.
M&L earthing complete with galvanised steel plate electrode 600mm x 600mm x 6.3mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts check nuts and GI washers earth plate surrounded by picked layer of coal dust and common salt 15cm thick all around bottom and top and watering pipe 20mm bore of GI pipe medium bore GI pipe light grade connected to funnel heavy wire mesh for watering purpose and 15mm bore GI pipe light grade for protection of galvanised earth wire from earth plate upto 7.5 metre and connecting to , main switch board including 10mm thick cast iron cover angle iron frame and PCC 1:2:4 type B-I for concrete pit, including necessary excavation and earth works etc , as shown in electrical plate No 5 of SSR Part - I of 1991 and testing on including taking out old unserviceable earthing completion all as specified. Note : PCC chamber shall be constructed at least 1.5m away from earth pit pipe for watering shall be provided in slanting manner.
M & L of flame proof point wiring in concealed/surface ERW suitable steel conduit using starnded copper conductor cable of 1.5 sqmm, PVC insulated unsheathed ZHFR cable complete with all fittings and flameproof accessories except junction boxes and 1.5 sqmm earth wire multi stranded ZHFR copper earth wire to common earth and connecting to earth dolly complete all as specified and directed by Engr-in-charge.(Note:- Surface finishing of disturbed surface of wall and finishing of existing matching painting to be included in the item rate.)
All as per item No 39 above but for cable size 2.5 Sqmm all as specified and directed.
All as per item No 39 above but for one flame proof switch socket & plug combined with using cable size 2.5 Sqmm all as specified and directed.
S&F switch flame proof rotary type with termination box in LM6, 16A, single pole 250 volts complete all as specified and directed by Engr-in-charge.
S & F of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth all as specified and directed.
S&F of flame proof LED light fitting 2x16 watt CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
S&F of flame proof LED light fitting 70 wattt for security light CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
S & F of sheet metal enclosures made out of CRCA mild steel sheet IP-43protection flush mounted with metal door powder coated DB SPN 12 way 230V AC with 200Amp rated bus bar double door 12 modules dust and vermin proof suitable for incorporation of RCB's and isolators etc complete all as specified.
S & F of sheet metal enclosures made out of CRCA mild steel sheet IP-43protection flush mounted with metal door powder coated DB SPN 8 way 230V AC with 200Amp rated bus bar double door 8 modules dust and vermin proof suitable for incorporation of RCB's and isolators etc complete all as specified.
S & F RCBs for earth leakage,overload and short circuit protection suitable for 230 volts, AC supply 63 Amps, double pole rupturing capacity not less than 30mA complete all as specified and directed.
S & F RCBs for earth leakage,overload and short circuit protection suitable for 230 volts, AC supply 32 Amps, double pole rupturing capacity not less than 30mA complete all as specified and directed.
S&F MCB SPN 63 Amps 240 Volt complete all as specified
S&F MCB SPN 32 Amps 240 Volt complete all as specified
S&F MCB SP 6 to 32 Amps 240 Volt complete all as specified
M & L of Sub main wiring complete with two single core 6 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable ZHFR with continuous copper earth conductor of 6 sqmm in & including ERW suitable steel conduit complete all as specified and directed by Engr-in- Charge.(Note:-Extention of jointing works and its connected acessories of existing sub main to new sub main wiring is included in this item rate. )
Supply & laying of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 2 core crosss- section area 25 Sq mm complete all as specified.
Excavation in trenches in soft/loose soil n. exc 1.5 mtr wide and n exc 1.5 mtr in depth for tenches , foundation and getting out complete all as specified and directed by Engr in charge.
Returning , fillingin, including spreading levelling ,watering and well ramming in layers in soft/loose soil n. exc 25 cm.complete all as specified and directed by Engr in charge.
Removing excavated material(soil) n exc 50m and depositing where directedc at a level n exc 1.5 mtr above the starting point in soft/loose soil. complete all as specified and directed by Engr in charge.
M&L for sand filling in trenches including watering and consolidation. complete all as specified and directed by Engr in charge.
M&L for sub class "B" brick laid in trenches for cable protection and laid perpendicular to the length of cable .
S&F GI pipe light grade 20 mm dia for protection of earth wire under hard standings complete all as specified and directed by Engr-in-charge.
S&F GI pipe light grade 40 mm dia for protection of earth strip under hard standings or fittings and fixed complete to walls & ceilings or laid in floors complete all as specified and directed by Engr-in-charge.
M & L of earthing complete with galvanised steel plate electrode 600mmx600mmx6.00mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts check nuts and GI washers earth plate surrounded by picked layer of coal dust and common salt 15cm thick all around bottom and top and watering pipe 20mm bore of GI pipe medium bore GI pipe light grade connected to funnel heavy wire mesh for watering purpose and 15mm bore GI pipe light grade for protection of galvanised earth wire from earth plate upto 7.5 metre and connecting to , main switch board including 10mm thick cast iron cover angle iron frame and PCC 1:2:4 type B-I for concrete pit, including necessary excavation and earth works etc , as shown in electrical plate No 5 of SSR Part - I of 1991 and testing on completion all as specified. Note : PCC chamber shall be constructed at least 1.5m away from earth pit pipe for watering shall be provided in slanting manner complete all as specified and directed by Engr-in-charge.
M&L of earthing complete with copper plate electrode 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead burried directly in ground (earth pit not less than 2.25 mtrs deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to copper earth strip 20x3 mm by means of bolts, nuts check nuts and GI washers earth plate surrounded by packed layer of coal dust and common salt 15cm thick all around bottom and top and watering pipe 20mm bore of GI pipe medium bore GI pipe light grade connected to funnel heavy wire mesh for watering purpose and 15mm bore GI pipe light grade for protection of galvanised earth wire from earth plate upto 7.5 metre and connecting to , main switch board including 10mm thick cast iron cover angle iron frame and PCC 1:2:4 type B-I for concrete pit, including necessary excavation and earth works etc , as shown in electrical plate No 5 of SSR Part - I of 1991 and testing on completion all as specified. Note : PCC chamber shall be constructed at least 1.5m away from earth pit pipe for watering shall be provided in slanting manner complete all as specified and directed by Engr-in-charge.
S&F of Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed by Engr-in-charge.
S&F of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engr-in-charge.
S & F of aluminium strip 25 x 3.15mm buried in ground with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engr-in-charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI strip 24x4mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washersand including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing of LED Flood light 70 watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp connecting up with three core flexible copper conductor cable of suitble size complete all as specified and directed by Engineer-in-Charge.
Material and labour of surface/concealed point wiring complete with 2.5 sqmm (nominal cross section area ) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked ) drawn through and including PVC rigid conduit 20mm dia( heavy duty ) with all fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken boxe of suitable size (min 60mm deep, suitable length and 1.2mm thick ), 3mm thick bakelite plastic laminated sheet for mounting with frame and top cover for switches and socket ,fan regulator, for light/fan point controlled by one switch, top cover fixed with brass screws & cup washers including provn of 2.5 sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good distrubed surface of wall/ceiling/floors etc by using CM (1:3 ) to matching with existing surface, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of switch piano flush type, single pole, one way, 15/16 Amps ISI marked, complete all as specified and directed by Engineer-in-charge.
M/s badrinath Traders
B D BATRA AND SONS
KAY VEE CONSTRUCTIONS
G N CONSTRUCTIONS
SWARN SINGH AND CO.
K L JINDAL AND CO.
R K GOYAL AND CO
SIGMA ENGINEERS AND CONTRACTORS
LM CONSTRUCTIONS
M/s VISHAL ELECTRIC STORE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .