Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance DANIEL FURNITURES PRIVATE LIMITED RIICO INDUSTRIAL AREA BORANADA E 848 IV PHASE 342021 JODHPUR INDIA JODHPUR CITY RAJASTHAN 342012 | JODHPUR | RAJASTHAN | 342021 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
11 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
PWD Division Hanumangarh
Providing and Fixing Compactor Unit at Modern Record Room and LR Office in Hanumangarh
2021_CEPWD_230297_1
EEH_NIB_NO_02_YEAR_2021-22
Open Tender
Civil Works
Item Rate
92 days
Hanumangarh
As Per NIB Document
3 documents required · 3 mandatory
₹1,000
Ex. En. PWD Dn Hanumangarh
Yes
19 Aug 2021
1 Jul 2021
13 Aug 2021
1 Jul 2021
11 Aug 2021
1 Jul 2021
1 Jul 2021 - 11 Aug 2021
90 days
Amount
Supply, Placement and Fixing of Optimizer Storage System fixed/ moveable bolted to undercarriage which rolls onto the channels, which are firmly embedded to the ground of approved make with the following specifications :- Main Body Construction: Rigid Knock Down construction made out of minimum 0.8 mm thick CRCA steel conforming to IS: 513 Gr. D each body block (SS/SL/TM) building consisits of 1 Main unit & then Add-on units Each unit has 6 loading levels formed by 5 nos. adjustable shelves. The load carrying components of storage system should be designed as per IS 800 / IS 801 design standards.
Finish : The bodies including shelves are given antirust surface treatment & are powder coated with epoxy polyester powder, involves minimum 7 step process. Final finish consists of epoxy polyester powder coating of approved colour & shade with a dry film. Thickness of minimum 40 microns. The testing of paint is done for various physical & chemical properties as per IS: 101. The material is then oven baked with a controlled temperature of 180 deg. C to 200 Deg. C. And before carrying out epoxy polymer powder coating, pretreatment to steel surface should be carried out such as degreasing, pickling & Phosphating. Degreasing should be carried out by using caustic soda, soda ash, Bi sodium phosphate &sulphuric metasilicate in proper concentration at closely controlled temperature. The component after degreasing should be rinsed in water. Pickling should be carried out subjecting the component to sulphuric acid solution for a specified time and washing them again with water.The degreasing and pickling should be confirmed to requirement of IS 3194.
Phosphating should be carried out by subjecting the components to a treatment in phosphoric acid tank with sodium bitrate as accelator so that a fine coating is achieved. The procedure contained in IS-6005 and IS-3618 should be adhered to. Pasivation is done by subjecting the component to dilute chromic acid rinsing.
Shelf Construction : It is made of minimum 0.8 mm thick CRCA steel conforming to IS: 513 Gr. D or DD. It is max load bearing capacity is 115 Kg + 5 Kg tolerance uniformly distributed per shelf. Shelves are mounted on support brackets & shelf level can be adjusted at approx 25mm + 2mm pitches. There are 5 adjustable shelves per body giving 6 loading levels.
Undercarriage Construction: The undercarriage is a welded frame made of HRC sheet 3.15 mm thick conforming to IS: 10748/ IS 1079 suitably fabricated to take the loads based on Configuration. Sizes of sections are 25 x 100 x 25 mm, 25/45 x 100 x 25/45 mm, 45 x 45 mm or as may be find suitable to meet with design requirements. The undercarriage after pre-treatment is coated with final finish consisting of epoxy polyester powder coat of approved colour & shade with a dry film. Thickness of minimum 40 microns + 5 microns.
Movement of the Unit : Drive Type Configuration movement is achieved mechanically through a PU Drive wheel or a steel wheel having three arms and Sprocket Chain Tensioner' arrangement mounted rigidly onto body side.The Hand wheel arrangement should consist of the unit locking arrangement when engaged locks the shaft of the sprocket & prevents the motion of units in either direction for preventing the unit from moving when in use. Each movable undercarriage is provided with 2 Rollers on the shaft for driving 2 antifriction ball bearing for rolling and 4 antifriction ball bearing for guiding between rail. Drive Chains should be incorporated in the compactor unit with minimum 3/8" pitch traction. (No chains should be visible/ incorporated along the rail of the compactor system. Fittings - Centralized Locking : A Centralized locking arrangement having minimum 10 lever lock with keys in duplicate is provided through locking stiffener mounted onto back of single last unit so that is gets locked on channels when all the units are brought together.
The Recess handle lock is of approved make & placed at suitable height. Stoppers should be provided on either ends of the rails to prevent the Compactor unit from moving away from the rail wherever required.
Fasteners: The nuts & bolts are galvanized/ blackodized/ Zn Plated as per IS 3655 and HSFG Bolts as per IS 4000 and the chemical and mechanical property should confirm to IS 1367. Guide Channels consisting of "J" section 2mm thick HR sheet & minimum 30 mm Square bright bar both connected by screws or guide rails comprises of solid round shaft of minimum diameter 30 mm (Bright bar) in ground finish, press fit in to cold formed 'U' channel made from 14 G Thick material confirming to IS 10748 / 1079. Prior to the embedding of the guide channels with the help of raul plug & screw the ground has to be properly leveled condition. The guide channels or Guide Rails should be such that the movement of the upper body on these rails/channels should have minimum friction and almost effortless.
Each unit of optimizer consists of single faced fixed body, two faced mobile body, and single faced mobile body at the end. Both the single faced body consists of one block (which means storing of record from one side) and two faced mobile body consists of two blocks (which means storing of record from two sides). And each block consists of 6 box in a column and 4 box in a row and internal dimension of each box should not be less than 910mm(W) x 381mm(H) x 450mm(D) (+ 5 mm tolarane). And each body of this unit must be a single bay. The maximum dimension of each unit should not exceed 4039mm(W) x 3740mm(D) x 2895(H) (- 10 mm tolarane). The whole aggarngement should be either welded or bolted, but all nuts or bolts should be provided in such a way that it shouldn't harm any document or the persons working with these units. All the material used for the construction of each unit must confirm to respective latest IS specification. The whole work would be carried out as per the specification and direction of Enigneer-in-charge.
ITEM : SINGLE FACED FIXED BODY(SF) (Having 4 Bay or Block in a row)
ITEM : TWO FACED MOBILE BODY(TM) (Having 8 Bay or Block in two equal rows)
ITEM : SINGLE FACED MOBILE BODY(SM) (Having 4 Bay or Block in a row)
Special Conditions :- 01. The Contractor Should have an experience of providing & fixing Compactor in any government agency /Department of either a single work of amount not less than Rs. 50.00 Lacs or two works, each of amount not less than Rs. 25.00 Lacs. The experience certificate of above works which is signed by the competent authority of concerned department should be attached with the BOQ. 02. The structural design of the compactor should be done for the self weight, dead load & checked for creep and fatigue analysis, by the contractor and should be proof checked by the reputed educational institute such as MNIT Jaipur, BITS Pilani or as directed by Engineer-in-charge on its own cost. 03. All the part which are incorporated in the fabrication of the compactor should be certified with relevant IS Code 04. If there will be any harm done to the existing building or structure while providing & fixing compactor, should be repaired or maintained to its original conditions by the contractor itself on its own cost.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .