Executive Engineer
Office of Executive Engineer,Ropar canal and GWD
Estimate for Construction of Pump House building for providing Lift Irrigation Facilities to the area of villages Rampur Jhajjar etc in Changer area of Shri Anandpur Sahib
2026_WR_161506_1
66/22A/2025-26
Open Tender
Civil Works
Item Rate
180 days
village rampur jhajjar near Shri Anandpur Sahib
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹2.0 L
office of Executive Engineer,Ropar canal and GWD
9 Mar 2026
20 Feb 2026
10 Mar 2026
21 Feb 2026
10 Mar 2026
21 Feb 2026
2 Mar 2026
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil
Cement concrete 1:3:6 with stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type
First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Brick Work In Super Structure with 1:6 Cement Sand Mortar
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Conglomerate floor 50mm thick cement concrete 1:2:4 on 100mm thick cement concrete 1:8:16 and 100mm sand filling. using mechanical mixer for mixing of material
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25 mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower boltsand finished, fixed in position including the cost of cement concrete1:3:6for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. c) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Providing and fixing 110 mm dia SWR U.P.V.C Rain water pipe (ring fitted type-A) as per IS:13592 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-incharge. (If fixed on wall face clamp to be paid separatly as per respective item)
Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Bottom Khurra on ground 1.2m x 0.6m consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3
Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed)
12.5 mm Cement Plaster 1:4
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two coats applied @ 1.43litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shade on wood work,metal licor plastered,concrete surface to give an even shade.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material
Providing & Fixing Hydraulic Door closer ISI mark with necessary screws etc complete (c) I.S.I Designation No. III (size of door 851mm to 1000mm)
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.
Cement Conc. 1: 2 :4 with stone ballast or shingle
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 a)Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- d 35mm thick
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) ii) area above 0.50 sqm
Wire Gauge Red meranti wood Super (18 to 19 kg per cft. Approx.) door shutter without springs housed in chowkats a)35mm thick
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respec b)Glazing area above 0.09 sqm ii)4mm thick or 10.78 Kg/ sqm
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body (600 x600 mm)
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Non traffic Areas and streets having width less than 3.05 mt.( Also not to used over footoaths).
Iron grated doors, including pintle hinges & arrangements.
Earth work inexcavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in15cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipelines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewateringof rainwater,diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. Earth work upto 1.5 m. Depth for All classes of soil except rocky
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. ;100 mm internal Diameter
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. 200 mm internal diameter
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. 150 mm internal diameter
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. a)315mm o/d pipe mm o/d
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In Charge. (Glazing and paneling to be paid for separately) : b)For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float Glass of 5 mm thick
Advance Direction sign board 1200x900mm rectangular per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. grade sheeting fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.60x0.60x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 . (b)Using high intensity Microprismatic grade retroreflective Sheeting Type XI as per ASTM D 4956-09 and as per IRC 67 2012
Providing & Fixing LED based SPV street lighting system with 12 watt 75 SPV Module 12.8 V- 30Ah lithium Ferro Phosphate battary (>2000 Cycles), 6 mtr Hot dipped GI Pole, 76.1 mm OD 3.6 mm thick & Zinc coated as per entire satisfaction of engineer in charge
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Size 550 mm x 400 mm x 815 mm
Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect.
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C)ACRYLIC TOWEL RING SIZE 20 MM DIA 610 MM LONG
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 600mmx450mm
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. C.P. brass Bib cock foam flow without flange
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P.brass 15mm Angle valve without flange
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut
Providing and fixing jet spray with 2'-6" long PVC pipe.(a) With C.P. Brass nut
Providingand fixing inpositionSWRUPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including cuttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.(d) for 75 mm outer dia) P Trap/Floor Trap 75mm x 75mm
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. Size 75 mm x 75 mm
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank (i) Triple Layer Tanks
Providing&fixinginpositiononterrace(atall floor levels) HDPE tank cover for water storage tanks of approved make (to the approval of Engineer-in-charge) complete in all respect. For 500 l tank
Providing and fixing in position G.I. Tank Nippleof approvedmake (to theapproval of Engineer-in-charge) in PVCWater storage tanks complete in all respect. G.I. tank nipple 20mm i/d
Providing and fixing in position automatic brass Ball Cock in tanks.B Brass Ball Cock with rod and Plastic Ball (ii) 20 mm i/d
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
Providing, fixing and jointing ISI Marked Gun Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. (b) 20 mm i/d Gun Metal peet valve heavy pattern.
Making connection with the existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of G.I Tee etc. in the pipe line (including cost of G.I Tee) complete in all respects
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipesasper IS15778(ISImarked with the prior approval of Engineer-in Charge),havingthermalstabilityforhot& cold water supply, including all CPVC plain&brass threaded fittings i/c fixing thepipewithclamps at 1.00mspacing includingjointingofpipes&fittings,with onestepCPVCsolventcementandtesting of pipes complete as per direction of Engineer-in-Charge SDR11CPVCpipes&fittings20mm o/d
INTERNAL- EXPOSED ON WALL : ProvidingandfixingChlorinatedPolyvinyl Chloride(CPVC)pipesasperIS15778(ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, includingallCPVCplain&brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointingof pipes&fittingswithonestep PVCsolvent cement andtestingofpipes completeasperdirectionofEngineer-in Charge SDR11CPVCpipes&fittings20mm o/d
EXTERNAL INTHEGROUND : Providing and fixingChlorinatedPolyvinylChloride (CPVC)pipesasper IS15778(ISImarked with the prior approval of Engineer-in Charge),havingthermalstabilityforhot& coldwatersupplyincludingallCPVCplain &brass threaded fittings. This includes jointingof pipes&fittingswithonestep CPVCsolvent cement,&testingof joints excludingcostofexcavationcompleteas per direction of Engineer-in-Charge. SDR11CPVCpipes&fittings20mm o/d
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete1:2:4benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspectionchambercoverandframe(Weight as per I.S.I specifications) painted with 3 coatsofblackbitumasticpaintconformingto I.S.I complete as per standard design Size450mmx450mminsidewithRCC 455mmx455mmcoverandframe light duty double seal
Constructing soakpit1.20x1.20x1.6mdeep, 230mmthick1:5brickworkhoneycombwith bricks of Ist Class filled with brickbats includingS.W. drainpipe100mmDiametre and1.20m longcompleteasper standard design
Providing and fixing in position singel socket SWR UPVC soilwaste or antisyphonage pipes asper IS13592 of E.D.C manufactureor of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A d)75mmo/dsinglesocket SWRUPVC pipe lines laid complete
Providingand fixing in position singel socket SWRUPVC soilwaste or antisyphonage pipes asper IS13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A d)100 mm o/d single socket SWRUPVC pipe lines laid complete
Providingand fixing inposition15mmC.P. Pillarcock foamflow ofapprovedmake(to the approval of Engineer-in-charge)
RECESSEDPVCCONDUITPIPEWIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI marked) recessed in wall, etc., complete with powder coated or anodized concealed metal boxes (1.6mm thick with brass lugs) required for a suitable number of modules (modular accessories) for having step-type electronic fan regulators (two modules). 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/universal socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with frame plate etc., PVC connector (for the fan box and call bell), steel hooks, sheet metal fan box (1.6mm thick, hexagonal), circular junction boxes (four-way PVC) 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1 sq. mm, 1100volts grade (for 6Amp. wall socket and plug control point), and other petty material, etc., including the cost of the above material, cutting and filling up of chases (with finishing the surface): - Wiring fan point (With fan box)
RECESSEDPVCCONDUITPIPEWIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI marked) recessed in wall, etc., complete with powder coated or anodized concealed metal boxes (1.6mm thick with brass lugs) required for a suitable number of modules (modular accessories) for having step-type electronic fan regulators (two modules). 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/universal socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with frame plate etc., PVC connector (for the fan box and call bell), steel hooks, sheet metal fan box (1.6mm thick, hexagonal), circular junction boxes (four-way PVC) 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1 sq. mm, 1100volts grade (for 6Amp. wall socket and plug control point), and other petty material, etc., including the cost of the above material, cutting and filling up of chases (with finishing the surface): - Wiring light point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI marked) recessed in wall, etc., complete with powder coated or anodized concealed metal boxes (1.6mm thick with brass lugs) required for a suitable number of modules (modular accessories) for having step-type electronic fan regulators (two modules). 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/universal socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with frame plate etc., PVC connector (for the fan box and call bell), steel hooks, sheet metal fan box (1.6mm thick, hexagonal), circular junction boxes (four-way PVC) 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1 sq. mm, 1100volts grade (for 6Amp. wall socket and plug control point), and other petty material, etc., including the cost of the above material, cutting and filling up of chases (with finishing the surface): - .Wiring 6Amp. wall socket point
RECESSEDPVCCONDUITPIPEWIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI marked) recessed in wall, etc., complete with powder coated or anodized concealed metal boxes (1.6mm thick with brass lugs) required for a suitable number of modules (modular accessories) for having step-type electronic fan regulators (two modules). 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/universal socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with frame plate etc., PVC connector (for the fan box and call bell), steel hooks, sheet metal fan box (1.6mm thick, hexagonal), circular junction boxes (four-way PVC) 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1 sq. mm, 1100volts grade (for 6Amp. wall socket and plug control point), and other petty material, etc., including the cost of the above material, cutting and filling up of chases (with finishing the surface): -.Wiring 16/20Amp. power plug control point
RECESSEDPVCCONDUITPIPEWIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI marked) recessed in wall, etc., complete with powder coated or anodized concealed metal boxes (1.6mm thick with brass lugs) required for a suitable number of modules (modular accessories) for having step-type electronic fan regulators (two modules). 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/universal socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with frame plate etc., PVC connector (for the fan box and call bell), steel hooks, sheet metal fan box (1.6mm thick, hexagonal), circular junction boxes (four-way PVC) 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1 sq. mm, 1100volts grade (for 6Amp. wall socket and plug control point), and other petty material, etc., including the cost of the above material, cutting and filling up of chases (with finishing the surface): -.Wiring light point with double control switches.
Erectionof Ceiling/ Cabin/ Exhaust fan having connectionwith PVC insulated PVCsheathed two single core copper conductor (FR) cable 0.75sq.mm completeErection of Ceiling fan
Erectionof Ceiling/ Cabin/ Exhaust fan having connectionwith PVC insulated PVCsheathed two single core copper conductor (FR) cable 0.75sq.mm complete ErectionofExhaust fanwith louver shutter on the wall/ window grill
MINIATURE CIRCUIT BREAKERS SupplyanderectionofMiniatureCircuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacityof 10kA,Curve-Cand lowwatt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existingMCBdistributionboardasper PWDGeneral Specifications including connections with suitable size of thimbles/lugs:MCB Single Pole 6-32amp. (10kA, Curve-C)
MINIATURE CIRCUIT BREAKERS SupplyanderectionofMiniatureCircuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacityof 10kA,Curve-Cand lowwatt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existingMCBdistributionboardasper PWDGeneral Specifications including connections with suitable size of thimbles/lugs:MCBSinglePole50,63amp. (10kA,Curve C)
Supply & erection of PVCCasing 'n' Capping (Double Lock) ISImarked for wiringpurposesincludingcostofbends (L), (U), (T) & inspection boxes etc., where necessary including other petty material PVC Casing 'n' Capping Size 20mm x 12mm
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 1sq.mm (Un-sheathed)
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 1.5sq.mm (Un-sheathed)
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 2.5sq.mm (Un-sheathed)
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 4sq.mm (Un-sheathed)
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 6sq.mm (Un-sheathed)
Erectionof ceiling/Cabin/Exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75sq.mm complete: Erection of ceiling fan
Supply of Tubelight set 25 w
Supply of Flood light 100 w
Supply of Led Bulb 30 w
Supply of Fans 48"
Front End loader 1 cum bucket capacity
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. 65 mm internal diameter 4.5mm thick
0.60 meter high G.I. barbed wire fencing with 1.05 meter angle iron posts 40x40x6 mm placed every 3 meters centre to centre 0.45 meter in wall with 1:2:4 Cement Concrete provided with 4 horizontal lines fixed with GI staples, turn buckles including painting of angles etc. for each post complete as per Satisfaction Of Engineer in Charge
Any Other Items
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.78 MB
BOQ_327384.xls
BOQ • 0.30 MB
ccess.pdf
Tender Documents • 0.14 MB
gstletter.pdf
Tender Documents • 0.32 MB
1of66.pdf
PDF • 0.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .