Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC CHANDPURA TIKAMGARH DIST TIKAMGARH MP | TIKAMGARH | TIKAMGARH | MADHYA PRADESH | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.0 L+₹805 (0.12%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.5 L+₹48,900.50 (7.02%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
1 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ CWE AF BHISIANA
Repair and Maintenance of external electric supply along with connected items at AF Station Abohar under GE (AF) Bhisiana
2021_MES_448438_1
CWE(BHI)/BHI-19/2021-22
Open Tender
Civil Works
Item Rate
180 days
AFS ABOHAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE AF BHISIANA
₹20,000
Yes
28 Jul 2021
4 Jun 2021
3 Jul 2021
4 Jun 2021
1 Jul 2021
19 Jun 2021
4 Jun 2021 - 11 Jun 2021
60 days
Amount
Taking out U/S LT Cable from trench/on wall of any size, complete all as specified and as directed.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 185 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 95 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 70 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 50 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 35 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 25 Sqmm 4 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 16 Sqmm 4 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 10 Sqmm 2 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep for foundation of poles/stays/cables/Pipe lines etc and getting out in soft/loose soil, complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers each not exceeding 25 cm thickness, complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and as directed.
Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches, complete all as specified and as directed.
Supplying & laying old size sub calss 'B' bricks laid flat in trenches over the cable with length of bricks perpendicular to the direction of cable, adjacent/abutting each other, complete all as specified and as directed.
Prepration of old Steel Surfaces and applying two coat of synthetic enamel white paint to Steel tubular /PCC Pole and upto 1 Mtr height from ground level alternative in Yellow and black strips of 30 CM height each including numbering of Pole No with black paint, complete all as specified and as directed.
Trimming/cutting of trees branches.bushes obstructing the HT/LT lines making clear distance of 3 RM from the outer conductors of OH Lines all around and all substations fencing around pump house area, below surrounding of OHTs including removing of branches/ bushes of trees from site, complete all as specified and as directed.
M & L Make bore to road width under PCC foundation or road for laying of cable putting GI pipe for protection of cables, complete all as specified and as directed.
Supplying & fixing in replacement GI pipe light grade 50 mm nominal bore for passing of cable fixed to poles/walls/laid under floor/roads complete with and including, fittings as requited, complete all as specified and as directed.
Supply and fixing of GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall, complete all as specified and as directed.
Material and Labour for painting of LT Panels including cleaning of exposed surface with brush and emry paper including two coat of painting with smoke grey paint, including cleaning of all terminals with CRC Sprey and provides locking arrngement, any size of LT Panel, complete all as specified and as directed.
M&L for Synthetic Insulating Mat for Electrical Instrument of size 2mx1mx12mm, complete all as specified and directed.
Supply and fixing of LT cable joint kit size 6 sqmm to 16 Sqmm, complete all as specified and as directed.
Supply and fixing of LT cable joint kit size 25 sqmm to 50 Sqmm all as specified and directed.
Supply and fixing of LT cable joint kit size 70 sqmm to 95 Sqmm, complete all as specified and as directed.
Supply and fixing of LT cable joint kit size 120 sqmm to 185 Sqmm, complete all as specified and as directed.
Relaying/rerouting HT/LT XLPE cable of any size and any type after fault detection including neccessary earth work and relaying the old bricks after returning filling, complete all as specified and as directed.
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of 32 x 6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m complete all as specified and directed.
M & L for Earthing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work, PCC pit with RCC cover, charcoal salt funnel, GI wire up to 7.5 mtrs length complete all as spd and directed.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor , served with inner sheathing of PVC Tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire , one twin core cable circular of size 10 Sqmm, complete all as specified and directed.
S&F in replecement cable route indicator made out cast iron and embedded HT/LT cable and size of the cable on the plate of size 80mm dia 5 mm thick and grouting legs of suitable size including grouting in PCC foundation of suitable size, complete all as specified and as directed.
S&F in replecement MCCB 320 Amp 4 Pole of rupturing capacity 36 KA, complete all as specified and directed.
S&F in replecement MCCB 200 Amp 4 Pole of rupturing capacity 36 KA, complete all as specified and directed.
S&F in replacement MCCB 160 Amp 4 Pole of rupturing capacity 25 KA complete all as specified and directed.
S&F in replacement MCCB 125 Amp 4 Pole of rupturing capacity 25 KA, complete all as specified and directed.
S&F in replacement MCCB 100 Amp 4 Pole of rupturing capacity 25 KA, complete all as specified and directed.
S&F in replacement MCCB 63 Amp 4 Pole of rupturing capacity 25 KA, complete all as specified and directed.
S&F in replacement Time switches with battery backup 3P module, 24 hours programm, programable every 30 min, backup of 100 hrs current capacity 16 Amps complete all as specified and directed.
Taking down Unserviceable flood light from 15 mtr high mast pole through mechanically or manually after repair/replacement of flood light should be refix on same place complete all as specified & directed by Engr-in-charge. Note :- All T&P i.e ladder, tools, safety gloves etc will be provided by the contractor without any extra cost.
Supply & Fixing in replacement of 150 watts LED Flood light for high mast light highly efficient LED Flood light with lens made of pressure die cast aliminium housing, extruded aluminium heat sinks & enclosed with toughened glass IP-66 fitted on the wall/ roof top/pole etc. with the help of nuts,bolts, clamps PCC work including connection with 2.5 Sqmm 3 core copper wire, complete all as specified and as directed.
Supply & Fixing in replacement of Driver for flood light 150 Watts, complete all as specified and as directed.
Dismantling/Taking down of Street light/Flood light of any capacity and any size from 09 mtr LT pole, tower postand building complete all as directed.Note :- All T&P i.e ladder, tools, safety gloves etc will be provided by the contractor without any extra cost.
Supply & Fixing in replacement of 100 watts LED Flood light highly efficient LED Flood light with lens made of pressure die cast aliminium housing, extruded aluminium heat sinks & enclosed with toughened glass IP-66 fitted on the wall/ roof top/pole etc. with the help of nuts,bolts, clamps PCC work including connection with 2.5 Sqmm 3 core copper wire complete all as specified & directed by Engr-in-charge.
Supply & Fixing in replacement of Driver for flood light 100 Watts, complete all as specified and as directed.
Supply and fix in replacement of 45 W IP 66 LED Street light luminaire comprising of die cast aluminium housing with weather proof gasket for lamp & driver compartment with system wattage of 60 W . The LED shall be with 120 degree view angle , > 120 lumen/watt , lumen maintenance > 70 % at 50,000 hrs ,colour temperature of 5000- 6500K,>70 color rendering and LM 80 test compliance . The driver must be integral APFC and constant current type having THD <15% and power factor > 0.95 with short circuit protection , open circuit protection , reverse polarity protection , high voltage protection , protection against 10 KV high surges and comply to IEC 60598-1 , IEC 61000-3-2, IEC 61547. the luminaire must have secondary optics with perfectly matched lens for better light control, complete all as specified and as directed.
S&F in repairs PVC junction box of size 25x20x15cm with hinged door including locking arrangement, 04 Nos aluminium bus bar complete with necessary clamp, nut, bolt including single pole MCB of 6 Amp, complete all as specified and directed by Engr in charge.
Supply, installing, testing and commissioning factory made LT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with TPN aluminium bus bar of rating not less than 200Amps suitable foundation, complete all as specified and as directed.
Taking down old unserviceable GOD from two pole structure, complete all as specified and as directed.
Switch air break gang operated tripple pole mechanically operated from ground level mounted on 15 insulators, outdoor type suitable for vertical installation single break provided with locking arrangement for operating handle including seven levers "Navtal" lock consisting of mild steel channel, HT post top insulator copper alloy high pressure asembly with drop out expulsion fuses for phases, operating rod of 20mm dia medium grade G.I pipe complete confirming to IS-1018 of 1972 with continous current rating 200Amps, 11000 volts grade, complete all as specified and as directed.
Taking out U/S HT Cable from trench of any size, complete all as specified and as directed.
Supplying, laying, jointing and testing underground cable XLPE insulated screened armoured and PVC bedded HT 11000 volts grade (heavy duty) with aluminium conductor 3 core, 150 Sqmm, laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
Dismantling of HT cable Jointing Kit of any type and any size, complete all as specified and as directed.
M&L for Cable Jointing Kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and acessories suitable foe 3 Core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm, complete all as specified and as directed.
M&L for Cable Jointing Kit for 11 KV (Earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and acessories suitable foe 3 Core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 Sqmm, complete all as specified and as directed.
Material and labour for disconnection and dismantling of existing transformer of capacity up to 160 KVA for repair work and refixing and reconnecting the same complete all as directed as under:- (i) Replacement of gasket, nuts bolts and washer. (ii) Replacement of neoprene rubber washer. (iii) Replacement of silica gel. (iv) Replacement of copper lugs including ACSR jumpers from HT OH line to primary side of TF. (v) Cleaning of bush insulator LT/HT side. (vi) Tightening of connection of earthing lead to neutral & body. (vii) Replacement of MS cable box cover as per requirement at site. (viii) Replacement of HT & LT bush. (ix) Replacement of HT & LT bush copper Rod.
Material & Labour for filling of new transformer oil up to minimum level, break down value of transformer oil should not be less than 50 KV, complete all as specified and as directed.
Material & Labour for filtration/dehydration of transformer oil up to break down valve reaching upto 50 KV dilectric strength, complete all as specified and as directed. NOTE : Contractor will arrange filtration plant machine at site of transformer.Dehydration work will be carried out in working condition and electric supply will be taken from same transformer.
Material and labour for preparation of old steel surfaces and applying one coat of synthetic enamel paint to steel surface Transformer /voltage stabilizer/isolation Transformer after disconnecting the electrical connections and reconnecting LT cables after painting including writing of MES No. complete all as specified and as directed. Note: Spray paint to be used for painting surface of appliance after removing the old paint.
M&L for replacement of oil temperature indicator including nuts, bolts and gasket including taking down complete upto 200 KVA, complete all as specified and as directed.
Opening/stripping off voltage stablizer of capacity 50 KVA to 150 KVA including draining off oil, washing & cleaning duct, dirt & sludge deposit etc. from all parts. Removing damaged/deffective parts requiring replacement,making internal connection servicing of bushings and reassembling the voltage stablizer after repair and replacement work including new cork gasket, packing nuts, bolts, washer, etc. complete all as specified and as directed. Note : Servicing will be done by reputated company rep at site only.
M&L for calibration/overhauling/servicing of relay any type voltage,current(e.g. Earth fault relay/Over current relay,etc) for 11 KVA HT panel.The setting of these relays should be as per the PSPCL norms so that individual breaker/feeder should be tripped and fault is not travelled back to MRS and subsequently to PSPCL power house.The calibration of relay is to be done by a reputed firm and it is to be submitted to to the AGE E/M.All the calibration should be done in the presence of Engineer-in-charge. Note :- Any relay and HRC Fuse required during the work which should be measured in quoted rate.
Disconnecting the existing servicing electric supply from HT 11KV system of any make type taking out switch gear from SF-6 circuit breaker(any type)/VCB/OCB,cleaning from inside and out side by using CRC-26 spray or any other cleaning agents which can improve the electrical conductivity or properties,greasing whereever required overhuling of switchgear ,checking the fixed/moving contacts of all the 3 phases adjusting electrical/electronic/mechanical components all as per mfg instruction manual and standard practice & reassembling the same after necessary servicing repair including testing and commissioning in its original position & necessary connection etc all as specified and directed.This work is to be get done from company authorised sales and supplier dealers and complete all as specified and as directed.
SUDESH ENTREPRISES
Aman Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .