Executive Engineer(E), BSNL Elect.Division,Kanpur
Executive Engineer (E), BSNL Electrical Division, 7th floor, Doorsanchar Bhawan, Mall Road, Kanpur
CAMC of Electro-mechanical services at T. E. Bldg. Talbehat, Babina, Mehrauni, Gursarai and Moth under SSA Jhansi. (Rectification of handing over defects points).
2022_BSNL_113486_1
01/TED-KP/2021-22 dt.27.07.2021
Open Tender
Electrical Works
Item Rate
30 days
Jhansi
Plz. refer tender documents
2 documents required · 2 mandatory
₹590
AO(Cash) O/o GMTD BSNL, Kanpur
₹3,067
9 Sept 2022
20 Apr 2022
4 May 2022
20 Apr 2022
2 May 2022
20 Apr 2022
Repairing of the following faulty Electrical items/ accessories complete with connections, testing and commissioning etc. as reqd. (a) Rewinding of 1200/1400 mm. sweep ceiling fan.
Repairing of the following faulty Electrical items/ accessories complete with connections, testing and commissioning etc. as reqd. (b) Rewinding of 400 mm. sweep wall fan.
Repairing of the following faulty Electrical items/ accessories complete with connections, testing and commissioning etc. as reqd. © Rewinding of 450 mm. sweep exhaust fan.
Replacement of the following faulty/burnt Electrical items/ accessories by new one complete with connections, testing and commissioning etc. as reqd. (a) 36 watt Electronic choke.
Replacement of the following faulty/burnt Electrical items/ accessories by new one complete with connections, testing and commissioning etc. as reqd. (b) 36 watt LED with holder (for compound light).
Replacement of the following faulty/burnt Electrical items/ accessories by new one complete with connections, testing and commissioning etc. as reqd. © 40 watt flourscent tube.
Replacement of the following faulty/burnt Electrical items/ accessories by new one complete with connections, testing and commissioning etc. as reqd. (d) 2.5 MFD condenser (for ceiling fans).
Replacement of the following faulty/burnt Electrical items/ accessories by new one complete with connections, testing and commissioning etc. as reqd. (e) 35/36 watt LED type out door campus light.(M/s.Havells/ Orient/Bajaj or superior make).
Fire Detection System & Fire Extinguishers :: Cleaning & repairing of 06 Zones main control panel i/c repairing of Zonal Cards, mother board, control card, charging system, replacement of the faulty/burnt diodes, intigrated circuits, LEDs and power supply unit etc. complete with testing as required.
Replacement of the existing faulty smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Replacement of the existing faulty dual chamber heat detector ( heat cum rate of rise in temperature) type as per specification attached.
Cleaning & repairing of the existing faulty response indicator i/c testing etc. complete as required.
Cleaning & repairing of the existing faulty manual call point (Pill Box) i/c testing etc. complete as required.
Cleaning & repairing of the existing faulty electronic hooter cum speaker i/c testing etc. complete as required.
Cleaning of the entire existing detectors installed in the Bldg. i/c testing etc. complete as required.
Refilling of the existing vacant 4.5 Kg. CO2 type fire extinguisher/Cylinder i/c pressure testing etc. complete as required.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .