Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹14.1 L+₹54,594 (4.03%)Rejected-Finance VILLAGE SEKHA PO MAGAR MUDIAN TEH DISTT GURDASPUR PB | GURDASPUR | GURDASPUR | PUNJAB | L2 | Rejected-Finance Other then lowest | |
| 3 | L3₹14.4 L+₹88,350 (6.53%)Rejected-Finance VPO BAILLY TEH DALHOUSIE DISTT CHAMBA HP 176303 | DALHOUSIE | CHAMBA | HIMACHAL PRADESH | 176303 | L3 | Rejected-Finance Other then lowest | |
| 4 | L4₹15.1 L+₹1.6 L (11.9%)Rejected-Finance | L4 | Rejected-Finance Other then lowest | |
| 5 | L5₹16.2 L+₹2.7 L (20.0%)Rejected-Finance 130 292 MAKHAN LAL KA HATA AJEET GANJ KIDWAI NAGAR KANPUR 208061 | 208061 | L5 | Rejected-Finance Other then lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
29 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)-143530
GE GSR- 58/ 2021-2022 Repair to roof and allied wks in OTM bldg under AGE B/R-II at Tibri Mil Stn
2021_MES_480207_2
GE GSR-58/2021-2022
Open Tender
Civil Works
Item Rate
240 days
GE Gurdaspur (Tibri)
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹50,000
Yes
24 Jan 2022
13 Nov 2021
1 Dec 2021
13 Nov 2021
29 Nov 2021
17 Nov 2021
60 days
Amount
Taking down cement plaster of any description on brick wall, etc including raking out joints, hacking for key scrubbing down with water etc.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces on wals in CM 1:4 finishing even and smooth withot using extra ceemnt complete all as specified and directed.
Dismantling of brick work, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:4 complete all as specified and directed.
All as per Srl item No 05 above but except bricks ( old dismantled serviceable bricks obtained from Sr item No 04 shall be reused after necessary cleaning of mortar)
M&L for preparation of newly plastered/ unplastered surfaces of wall and applying two coats of cement base paint of shade as approved over a coat of cement primer complete all as specified and directed.
M&L for preparation / complete removal of existing treatment of old decorated surfaces plastered or unplastered of walls and applying two coat of cement base paint over a coat of primer etc complete all as specified and directed.
Dismantling water tanks exc 250 ltr and not exc 500 ltr and S&F rotational moulded polythene, triple layers , water storage tank 500 ltr capacity, closed top, cylindrical, hoisted and fixed in position including S&F 20mm bore PTMT ball valve epoxy coated minimum weight 210 gms with aluminium rod complete all as specified and directed.
Disconnecting existing tank exc 250 ltrs and not exc 500 ltrs setting aside ( or lowering if required) for repairs cleaning etc and hoisting if required reconnecting and refixing in possition (Cleaning repairing etc measured separately).
S&F in repair 20mm dia float ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum wt 210 gms).
Taking up or down 15mm dia steel tubing and connections all as specified and directed.
S&F 15mm dia GI tubes medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Refixing 15mm dia steel tubing and connection in new or old position ( in wall ceiling floors etc) including cleaning old tubing complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections all as specified and directed.
S&F 20mm dia GI tubes medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Refixing 20mm dia steel tubing and connection in new or old position complete including cleaning old tubing all as specified and directed.
S&F in repair 15mm bore stop cock cast copper alloy CP screwed down high pressure with crutch or butterfly handle complete all as specified and directed.
S&F in repair 20mm bore stop cock cast copper alloy CP screwed down high pressure with crutch or butterfly handle complete all as specified and directed.
Taking down eaves gutters and rain water pipes ( any size or pattern) , including all fittings , heads, shoes, bends, swan necks etc including cleaning or refixing or removal to store (measured overall as fixed along the cente line over fittings and accessories).
S&F 110 mm bore PVC (SRW) pipes single socketed in any length fixed to walls with dash true nut and bolt at every 2 mtr length including all fittings complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SRW) bends any radius with access door.
S&F 110mm bore PVC (SRW) junction single/ double (Singe/ Double T) equal or unequal with access door.
Cutting or uprooting grass on old mud phuska/ roof removing rubbish off the premises cleaning surface and preparing to receive new treatment/ plaster.
Dismantling brick tiles or terracing tiles, single layer on roofs.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof.
M&L for PCC (1:2:4) type B-0 (12.5mm graded stone aggregates) as in roof kerbs, sloping padding in roof slab or mud stops, rounded or chamfered on edges.
M&L for 40mm thick brick tiles laid over 15mm thick screed bed in cement mortar 1:6 and jointed, , grouted flush in cement mortar 1:3 mixed 5% of crude oil of by weight of cement.
All as per item No 28 above but except tiles.
Supply only integral water proofing compound.
M&L for cleanind and preparation of surfaces and applying bituminous primer @ 0.30 ltrs/ sqm complete all as specified and directed.
M&L for apply evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ sqm complete all as specified and directed.
S&F (minimum) 3mm thick APP film based poly meric membrance minimum weighing 3 kg per sqm reinforced with polyester non wove fabric (weight not less than 150gms/ sqm ) and on primed surface alfter cleaning down the roof by brooms complete all as specified and directed.
M&L for repairing of RCC projections, chajjas, roofs facia ceiling by scrapping, cutting, derusting and cleaning exposed reinforcement of damaged loose RCC surfaces and applying neat cement slurry @ 3kg/ Sqm and filling the surface cement plaster 1:3 or cement concrete 1:2:4 type B-0, in layers as required, finished even and smooth and including application of finishes to match with existing (cement paint/ distemper etc) at height upto 6.50 mtr and in any situation including necessary form work complete all as specified and directed.
GORAYA AND CO
Havish Construction
JOGRAJ CONSTRUCTION COMPANY
DEEPAK AND CO
M/s. Nirmal Singh
buta singh and sons
talwinder singh and co
M/S Harjinder Singh Contractor
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .