| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹25.2 L+₹5.4 L (27.1%)Rejected-Finance | L2 | Rejected-Finance Being higher then L1 bid | |
| 3 | L3₹2.4 Cr+₹2.2 Cr (1127.2%)Rejected-Finance | L3 | Rejected-Finance Being higher then L1 bid |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER SILCHAR
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
CERTAIN REPAIR INCLUDING IMPROVEMENT IN ELECTRICAL DISTRIBUTION SYSTEM OF LAILAPUR GARRISON UNDER GE SILCHAR
2020_MES_356607_1
8553/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VAIRENGTE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹40,000
Yes
9 Sept 2020
29 Jun 2020
31 Jul 2020
29 Jun 2020
30 Jul 2020
14 Jul 2020
60 days
Amount
Dismantling of exsiting ACSR or AAC conductors (of any size), jumper from overhead line removing unservisable material from site of work complete all as directed.
Dismantling of corroded/ rusted/ defective cross-arms of MS. Channel or angle of any sections complete all as directed.
Dismantling of unservisable insulators of any size/type complete all as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth and getting out in soft/loose soil for errection of LT poles, laying of HT/LT UG cables complete all as directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dence soil complete all as directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding1.5m above the starting point complete all as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly complete all as directed.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified.
Supply, laying connecting testing XLPE/PVC sheathed, armored LT electric power Cable (heavy duty) with stranded aluminium conductore of size 240 Sqmm, 3.5 core 1100 Volt grade laid throught duct /pipe / trench etc incl cable gland and lugs complete all as specified.
Ditto all as per item ser No 09 here-in-above but of capacity 120 Sqmm, 3.5 core
Ditto all as per item ser No 09 here-in-above but of capacity 70 Sqmm, 3.5 core
Ditto all as per item ser No 09 here-in-above but of capacity 50 Sqmm, 3.5 core
Ditto all as per item ser No 09 here-in-above but of capacity 25 Sqmm, 3.5 core
Ditto all as per item ser No 09 here-in-above but of capacity 16 Sqmm, 4 core
Ditto all as per item ser No 09 here-in-above but of capacity 10 Sqmm, 4 core
Ditto all as per item ser No 09 here-in-above but of capacity 10 Sqmm, 2 core
Supply and Laying 40mm bore GI tubing light grade with all fitting for passing of cable under road, on wall or on pole with and incl clams, nuts, bolts etc incl taking down old unserviceable GI tubing od any size incl cutting, chases to wall/ floor and making good surface complete all as specified.
Supply and Laying 80mm bore GI tubing light grade with all fitting for passing of cable under road, on wall or on pole with and incl clams, nuts, bolts etc incl taking down old unserviceable GI tubing od any size incl cutting, chases to wall/ floor and making good surface complete all as specified.
Supply, Install, testing and commisioning of CPRI approved outdoor type LT feeder piller box (Near FTN Bldg) of suitable size recommended by CPRI approved manufacturer cubical floor mounted type factory made totally enclosed, dust ad vermin proof made out of 3.15 mm thick MS sheet duly painted with powder coated both side in and out, having proper locking arrangment in both front and rear side aluminium bus bar of 300 amps rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 4 wire, 500 volts, 50 HZ AC supply, hibling , cable entry boxes, cable gland incl iron angle frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I with the following:- Incoming:- (a) MCCB 200 Amps, 4 pole, 36 KA, 415V - 01 Nos Outgoing:- (a) MCCB 100 Amps, 4 pole, 25 KA, 415V - 01 Nos (b) MCCB 63 Amps, 4 pole, 16 KA, 415V - 01 Nos (c) MCCB 32 Amps, 4 pole, 16 KA, 415V - 01 Nos (d) MCB SPN 32 Amps 10KA - 02 Nos (e) Digital multi function meter - 01 Nos (f) Phase indicator lamps (RYB) set of 3 - 01 Set Note : (a) Excavation for grounding and PCC foundation for LT Panel shall be deemed incl in quated rate. (b) Extra space be left in panel for mounting 4 pole MCCB-01 Nos and dinrail for TPN/SPN MCB which shall be covered with blank plates.
Supply, Install, testing and commisioning of CPRI approved outdoor type LT feeder piller box (Alfa Hill) of suitable size recommended by CPRI approved manufacturer cubical floor mounted type factory made totally enclosed, dust ad vermin proof made out of 3.15 mm thick MS sheet duly painted with powder coated both side in and out, having proper locking arrangment in both front and rear side aluminium bus bar of 200 amps rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 4 wire, 500 volts, 50 HZ AC supply, hibling , cable entry boxes, cable gland incl iron angle frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I with the following:- Incoming:- (a) MCCB 100 Amps, 4 pole, 25 KA, 415V - 01 Nos Outgoing:- (a) MCCB 32 Amps, 4 pole, 16 KA, 415V - 03 Nos (b) MCB SPN 32 Amps 10KA - 02 Nos (c) Digital multi function meter - 01 Nos (d) Phase indicator lamps (RYB) set of 3 - 01 Set Note : (a) Excavation for grounding and PCC foundation for LT Panel shall be deemed incl in quated rate. (b) Extra space be left in panel for mounting 4 pole MCCB-01 Nos and dinrail for TPN/SPN MCB which shall be covered with blank plates.
Supply, Install, testing and commisioning of CPRI approved outdoor type LT feeder piller box (Barrack Hill) of suitable size recommended by CPRI approved manufacturer cubical floor mounted type factory made totally enclosed, dust ad vermin proof made out of 3.15 mm thick MS sheet duly painted with powder coated both side in and out, having proper locking arrangment in both front and rear side aluminium bus bar of 200 amps rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 4 wire, 500 volts, 50 HZ AC supply, hibling , cable entry boxes, cable gland incl iron angle frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I with the following:- Incoming:- (a) MCCB 150 Amps, 4 pole, 25 KA, 415V - 01 Nos Outgoing:- (a) MCCB 63 Amps, 4 pole, 16 KA, 415V - 02 Nos (b) MCCB 32 Amps, 4 pole, 16 KA, 415V - 01 Nos (c) MCB SPN 32 Amps 10KA - 02 Nos (d) Digital multi function meter - 01 Nos (e) Phase indicator lamps (RYB) set of 3 - 01 Set Note : (a) Excavation for grounding and PCC foundation for LT Panel shall be deemed incl in quated rate. (b) Extra space be left in panel for mounting 4 pole MCCB-01 Nos and dinrail for TPN/SPN MCB which shall be covered with blank plates.
Supply, Install testing, and commisioning outdoor Bus Bar box of suitable size recommended by CPRI approved manufacturer cubical floor mounted type factory made totally enclosed, dust ad vermin proof made out of 3.15 mm thick MS sheet duly painted with powder coated both side in and out, having proper locking arrangment in both front and rear side aluminium bus bar of 200 amps rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 500 volts, 50 HZ AC supply, cable gland incl iron angle frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I complete all as specified. Note : Excavation for grounding and PCC foundation for LT Panel shall be deemed incl in quated rate.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified.
Dismentaling old unserviceable RCC/Steel poles/struts of any size incl breaking up PCC foundation complete all as directed.
Supply and fixing of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (Over all length 09 metres long) conforming to IS-2713. Pole shall be painted with one coat of red oxide primer throughout internally and externally up to 1.5 mtr lenght fron bottom and the remaining extranal portion shall be paited with two coats of alluminium paint over a coat of red oxide primer and numbering the pole with whit paint alfa numaric letters on black patch complete all as specified. Note: Excavation and earth work and PCC shall be mersured and paid separatly under respective item.
Taking down of U/s LED Street light from pole of any size as directed.
Supply and fixing of LED Street light 40 to 50W with IP65 protection with bracket, MS clamps and nut bolts complete all as specified. Make : Havells / Crompton / Phillips / Bajaj or equivalent
Supply & Fixing Thermoplastic cable junction box for street lights of size 155x210x92 mm on pole with sutaible clamp including terminals for cable connection with IP 66/67 protection including one MCB single pole 6 Amp, 240 Volt, 10 KA, 'B' curve mounted on DIN rail and connecting all the incoming and outgoing cable terminals with lugs and cable gland complete all as specified. Make:- Hensel CAT No. KF 1616 G or equivalent model of make listed in particular specification.
Material and labour for 1.5 Sqmm, 3Core FRLSH Copper cable, PVC insulated, PVC shethed 1100V grade for connecting Security light from Juction Box compeled all as specified.
Material and labour for Rigid non-metallic PVC conduit (Havey grade) of 20mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for street light complete all as specified.
M/S P K ROY AND SONS
M/S M L Pratihar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .