Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹27.0 L+₹5.1 L (23.2%)Rejected-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-AOC NOT BEING LOWEST | |
| 3 | L3₹34.1 L+₹12.1 L (55.3%)Rejected-AOC | L3 | Rejected-AOC NOT BEING LOWEST | |
| 4 | L4₹34.1 L+₹12.2 L (55.6%)Rejected-AOC | L4 | Rejected-AOC NOT BEING LOWEST | |
| 5 | L5₹39.8 L+₹17.9 L (81.6%)Rejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L5 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
29 Jun 2023, 6:00 pmClosed
GE AF LOHEGAON
GE AF LOHEGAON LOHEGAON PUNE-411032
REPAIR AND MAINTENANCE OF PUMP SETS, SUBMERSIBLE PUMP SETS, MISC WORKS, CLEANING AND DISINFECTING UG SUMPS, OH RESERVOIRS AT 2 WG AND 9 BRD UNDER GE (AF) LOHEGAON AT AIR FORCE STATION PUNE
2023_MES_600626_1
8712
Open Tender
Civil Works
Item Rate
330 days
2WING AND 9BRD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF LOHEGAON
₹72,000
Yes
20 Sept 2023
3 Jun 2023
4 Jul 2023
3 Jun 2023
29 Jun 2023
17 Jun 2023
Amount
Taking out the submersible pump/Openwell Submersible Pump set for repairs and lowering down after repairs the submersible pump set of any capacity & of any type from the bore well to a depth of not exc. 70 mtrs including scrapping of the existing paint of submersible pump set and applying two coats of anti corrosive paint over a coat of primer complete after repair / replacement of spares and commisssioning all as directed by Engr-in-Charge. NOTE: COST OF REPAIR SHALL BE MEASURED AND PAID AGAINST RELEVANT ITEM
Repairs to submersible Pump set of electric driven of any type make and capacity upto 5 HP incl rewinding of the motor with same gauge and weight of PVC insulated copper conductor incl renewal of thrust plate,CI bowl,pump shaft,impeller ,Bearing,strainer,bush cable gaurd etc. reassembling, testing and commissioning complete all as directed by Engr-in-Charge.
Repairs to Non clog ,Open well submersible Pump set of electric driven of any type make and capacity upto 5 HP incl rewinding of the motor with same gauge and weight of PVC insulated copper conductor incl renewal of Mechanical seal, Bearing ,thrust plate,CI bowl,pump shaft,impeller ,strainer,bush cable gaurd etc. reassembling, testing and commissioning complete all as directed by Engr-in-Charge.
Renewal of column pipe 50 mm dia heavy duty ISI marked , 10 feet length both ends machine threaded with long thread heavy duty socket complete all as directed by Engr-in-Charge.
Replacement of unserviceable PVC weather proof cable and replacement with new PVC weather proof copper cable for size 3 core 2.5 sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
Replace of non return valve gun metal 50 mm bore complete all as directed by Engr-in-Charge. Make:- ISI marked
Replace of non return valve gun metal 150 mm bore complete all as directed by Engr-in-Charge.Make:- ISI marked
Taking out old unserviceable MCCB 400/360 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,400 Amps all as directed.
Taking out old unserviceable MCCB 250 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,200/250 Amps all as directed.
Taking out old unserviceable MCCB 200 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,200/250 Amps all as directed.
Taking out old unserviceable MCCB 160 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,160 Amps.
Taking out old unserviceable MCCB 100 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,100 Amps.
Taking out old unserviceable MCCB 63 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,63 Amps.
Material and labour for reparing/maintenance of existing electrical panel boards of pump sets by replaing worn out spares as starter/single phase preventor/ relay /contactors MCCB's / MCB's / switch gear / cable glands/ lugs pin type, U type etc, cleaning of panel board, tightening of cable connection to avoid sparking, insulating bus bars bracket portion of conductor and to ensuring proper function of the panel board all as directed by Eng-in-Charge. NOTE: (I) Cost of spares as starter /single phase preventor/voltmeter/Amp meter/ relay / contactor /MCCB's/ MCB's / Switch gear / cable gland etc shall be measured and paid against relevant item. (ii) Cost of lugs (pin type / U Type) ,insulation taps shall be included in quoted rate. (iii) Cost of fixing of spares shall deemed to be included in quoted rate.
Renewals/replacing the following spares to the existing elecrical panels complete all as directed by Engr-in-Charge.
S& F Voltmeter/Ammeter ,3 phase for range 0-200A Class-I, suitable as per existing
S&F in replacement of old unserviceable contractor 0f capacity upto 45 A,power operating voltage 415 V AC Capacity 3 pole with AC coil etc (Make: L & T,TC)
S&F in replacement of old unserviceable contractor 0f capacity upto 95 A,power operating voltage 415 V AC Capacity 3 pole with AC coil etc (Make: L & T,TC)
S&F in replacement of old unserviceable contractor 0f capacity upto 110/120 A,power operating voltage 415 V AC Capacity 3 pole with AC coil etc (Make: L & T,TC)
Over load relay with range 16 to 45 A (Make: L & T)
Over load relay with range 45 to 88 A (Make: L & T)
S& F Single phase preventor including Timer,415 V suitable for 100 HP motor.
Dismantling the centrifugal Pump/motor capacity Upto 3HP including disconnecting suction and delivery etc and reassembling same after replacement of necessary spares including greasing and painting of 2 coats of synthetic enamel paint using spray machine complete all as specified and as directed by Engr in charge. NOTE: 1.In case of Centrifugal pump dismantling of pump and motor will be paid seperatly. 2. In case of Monoblock pumpset pump/motor paid as one
All as per item no 16 but for the capacity of 5 HP to 7.5 HP
All as per item no 16 but for the capacity of 10 HP to 15 HP
All as per item no 16 but for the capacity of 20 HP to 30 HP
All as per item no 16 but for the capacity of 40HP to 50HP.
All as per item no 16 but for the capacity of 60HP to 75 HP
All as per item no 16 but for the capacity of 90HP to 100HP
Supply and replace following worn out spares of Centrifugal/monoblock pump sets.
Bearing as per existing Size suitable for up to 3HP motor
Bearing as per existing Size suitable for 5HP to 7.5 HP motor
Bearing as per existing Size suitable for 10 HP to 12.5 HP motor
Bearing as per existing Size suitable for 20 HP to 30HP motor
Bearing as per existing Size suitable for 40HP to 50 HP motor
Bearing as per existing Size suitable for 60HP motor
Bearing as per existing Size suitable for 75 HP motor
Bearing as per existing Size suitable for 90 HP motor
Bearing as per existing Size suitable for 100 HP motor
Rubber bush/star rubber for coupling as per existing size for upto 30 HP motor
Rubber bush/star rubberfor coupling as per existing size for upto 50HP motor
Rubber bush/star rubber for coupling as per existing size for upto 75 HP motor
Rubber bush/star rubber for coupling as per existing size for upto 90 HP motor
Rubber bush/star rubber for coupling as per existing size for upto 100 HP motor
Gland packing upto 30 HP pump
Gland packing for 40 HP motor
Gland packing for 50 HP motor
Gland packing for 60 HP motor
Gland packing for 75 HP motor
Gland packing for 90 HP motor
Gland packing for 100 HP motor
Supply and replace old worn out coupling with new Tyre coupling including machining,suitable to shaft dia of pump and motor of 5HP,12.5HP,20HP
Supply and replace old worn out coupling with new Tyre coupling including machining,suitable to shaft dia of pump and motor of 30HP,40HP,50HP
Supply and replace old worn out coupling with new Tyre coupling including machining,suitable to shaft dia of pump and motor of 60HP,75HP,90HP,100HP
Overhauling/servicing of Suction sweeper assembly trolley mounted with mud pump motor head 11.5 mtr complete all as specified and directer by Engr-in-charge. Make; Kirloskar Notes:- including spares require for making the assembly serviceable deemed to be included in subjected item.
Rewinding of electric motor 3 phase, 415 Volt capacity 1/2HP TO 3 HP, incoming disconnection electric connections, dismantling slots, taking out burnt windings and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing,greasing, painting with super enameled paint as per colour coad assembling the motor after rewinding and mounting at its own position, replacing the old nut, bolts and testing all as directed.
All as per item no. 28 but for the capacity of 5HP.
All as per item no. 28 but for the capacity of 10HP,12.5HP
All as per item no. 28 but for the capacity of 15HP,20HP.
All as per item no. 28 but for the capacity of 30HP.
All as per item no. 28 but for the capacity of 40HP
All as per item no. 28 but for the capacity of 50HP
All as per item no. 28 but for the capacity of 60HP.
All as per item no. 28 but for the capacity of 75HP.
All as per item no. 28 but for the capacity of 90HP.
All as per item no. 28 but for the capacity of 100HP.
Taking out unserviceable foot valve 80 mm dia from the UG sump and S&F new foot valve 80 mm dia ball type incl rubber gasket, bolts, buts complete all as directed.
Taking out unserviceable foot valve 100 mm dia from the UG sump and S&F new foot valve 100mm dia ball type incl rubber gasket, bolts, buts complete all as directed.
Taking out unserviceable foot valve 150 mm dia from the UG sump and S&F new foot valve 150mm dia ball type incl rubber gasket, bolts, buts complete all as directed.
Supply and fix spares for pumps of DSM 150/45, DSM 100/36, DSM 125/45, DBHS
a) Impeller 1st , II nd Stage
b) Pump Shaft
c) Shaft sleave
d) Cartrige bearing DE/NDE
e) Through bush
f) Split gland coupling
g) Wear ring
h) Lantern Ring
h) Gland coupling
Supply and replacing Automatic DOL starter suitable up to 5 HP submersible/ centrifugal pump set
Supply and replacing Automatic star Delta starter suitable 7.5 HP to 12.5 HP submersible/ centrifugal pump set
Replacement of nuts bolts to top & bottom cover of DSM pump 100 HP, 90 HP, 75 HP.
Supply & fixing in replacement LT cable 1100 volts grade PVC insulated multistranded copper conductor cable single core of size 35 sqmm. Make :- Polycab/Havells/Finolex
Servicing of Magnetic level sensor i/c removing, cleaning, greasing, checking for wear and tear, refixing, testing, installing, commissioning as directed by the Engineer-In-Charge Note : Spares if needed are not included in the above
Supply only in repair/replacement of Water Level Controller 5 Level/10 Level
Supply and fix in repair/replacement of Magnetic Level Sensor Make : RDS/CRISTAL
Supply and Fix Wire connection for Water level sensors and indicator of twelve core including installlation, testing and commissioning complete all as directed by Engr-in-Charge. Make: Sinetrac or equivalent
M&L for seven stage cleaning and sterilization of inside the RCC/ Steel Underground/semi underground/Over head/Sedmentation/clear water sumps of capacity As mentioned through bacteriological treatment by using hydrogen per oxide solution AND ULTRA VIOLET RAY. (a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b). Second stage is cleaning all the algae formation inside the tank . (c). Third strage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification. (e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tnk and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent. NOTE:-(i) COMPANY WILL SUBMIT LABORATORY TEST CERTIFICATE OF CHEMICAL USED BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE. (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID.ENTERING SCALES AND THE SAME SHALL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE PROVISION . (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM 03 MONTHS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY.
a) All as per Item no. 51 but for UG sump 100000 gallons capacity
b) All as per Item no. 51 but for UG sump 10,000 gallons capacity
c) All as per Item no. 51 but for UG sump 50000/30000 gallons capacity
d) All as per Item no. 51 but for O H Reservoir 300000 glns capacity
e) All as per Item no. 51 but for O H Reservoir 50000 glns capacity
f) All as per Item no. 51 but for O H Reservoir 150000 glns capacity
g) All as per Item no. 51 but for O H Reservoir 10000 glns capacity
h) All as per Item no. 51 but for O H Reservoir 25000 glns capacity
M&L Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom of the static tank and clean surface by scraping and two coats of white cement wash of capacity up to 10000 Glns complete all as specified and directed by Engr-in-charge
M&L Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom of the static tank and clean surface by scraping and two coats of white cement wash of capacity 10001 to 15000 Glns complete all as specified and directed by Engr-in-charge
M&L Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom of the static tank and clean surface by scraping and two coats of white cement wash of capacity 15001 to 25000 Glns complete all as specified and directed by Engr-in-charge
M&L Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom of the static tank and clean surface by scraping and two coats of white cement wash of capacity 50000 Glns complete all as specified and directed by Engr-in-charge
S&F spare parts of chlorine dozers at various location as per directed by Engineer in charge
a) Pump head (ferrules 1/4 & duckbill included)
b) Pump Tube (pack of 5)
c) Injection cheack valve 3/8"
d) 3/8 " white suction/discharge tubing
e) Check valve duck bill only (pack of 5)
f) Connecting nut 3/8 "
g) Connecting nut 3/8 with adapter(pack of 5)
h) Ferrule 1/4 " (pack of 24)
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion
S&F XLPE insulated, armoured heavy duty electric LT UG cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm,3.5 core complete all as specified and directed.
Supply and fix wall mounted metal enclosure consist of On load change over of capacity 250 Amps 415V, 4 pole to be installed as per the direction of Engineer in charge
Supply and fix wall mounted metal enclosure consist of On load change over of capacity 400 Amps 415V, 4 pole to be installed as per the direction of Engineer in charge
Taking out Old and Unserviceable pump set of any capacity including dismantling of inlet/Outlet connection and Supply and fix new monoblock pumpset of Head 24 meter,discharge 10.3 Lps including Pumpset fittiing as required in site and as discribed by engineer in charge.
Supply only drinking water testing Kit having testing water parameter like PPM of chlorine,PH etc .
Supply only Orthotolidine reagent for testing of chlorine content in drinking water as per direction of engineer in charge.
Supply only swimming pool water clarifier as per direction of Engineer in charge
Name of Installation glow sign board for installation made of acrylic sheet, metal sheet box and led tube light under Subdivison AGE E/M of size .75 mtr x 2mtr as per direction and approval of Engineer in charge (Notes :- Cost Electrical connection with proper switch and service wire deemed to be included in quoted rates, matter/colour to be printed shall be provided by Deptt)
M&L for painting of Pumps of capacity upto 12.5 HP
M&L for painting of Pumps of capacity upto 50 HP
M&L for painting of Pumps of capacity upto 100 HP
SKS Electricals
SUNHARI CONSTRUCTIONS
K.K.Enterprises
sapana enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .