| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 CrAccepted-AOC | ₹7.0 Cr | L1 | Accepted-AOC ACCEPTED BEING THE LOWEST AND REASONABLE. |
| 2 | L2₹7.0 Cr+₹1.4 L (0.20%)Rejected-Finance | ₹7.0 Cr+₹1.4 L (0.20%) | L2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 3 | L3₹7.4 Cr+₹40.0 L (5.73%)Rejected-Finance | ₹7.4 Cr+₹40.0 L (5.73%) | L3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 4 | L4₹8.0 Cr+₹1.0 Cr (14.6%)Rejected-Finance | ₹8.0 Cr+₹1.0 Cr (14.6%) | L4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 5 | L5₹8.3 Cr+₹1.3 Cr (18.7%)Rejected-Finance | ₹8.3 Cr+₹1.3 Cr (18.7%) | L5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹7.4 Cr
EMD Value
₹6.9 L
Closing Date
22 Dec 2021, 6:00 pmClosed
CHIEF ENGINEER CHENNAI ZONE
CHIEF ENGINEER CHENNAI ZONE ISLAND GROUNDS CHENNAI 600 009
PROVISION OF DEFICIENT STUDENT OFFRS ACCN WITH ALLIED INFRA AT ASC CENTRE AND COLLEGE, BANGALORE
2021_MES_482809_1
88534/E8
Open Tender
Civil Works
Lump-sum
760 days
BANGALORE
As per Appendix A of NIT
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (P) Bangalore
₹6.9 L
Yes
11 Jan 2022
21 Oct 2021
24 Dec 2021
21 Oct 2021
22 Dec 2021
16 Dec 2021
21 Oct 2021 - 10 Nov 2021
Amount
Lumpsum price worked out by the tenderer for BUILDINGS / STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for SITE CLEARANCE AND DEVELOPMENTS as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for ROAD / PATH / HARDSTANDING/ CULVERT as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for COOLING APPLIANCES as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for SOLAR WATER HEATER as listed in Schedule ‘A’ Part-XII
Lumpsum price worked out by the tenderer for BOREWELL as listed in Schedule ‘A’ Part-XIII
SCHEDULE 'A' PART XIV (MISCELLANEOUS ITEMS) Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only.
INTERNAL ELECTRIC SUPPLY
Supply and Fix Telephone socket modular type RJ11 (01 module) all as per Cat No. 6772 62 of Legrand or techno-commercially equivalent of other specified makes etc., complete all as specified and as directed.
Material and Labour TV socket outlet, one module fixed complete all as directed by Engineer-in-Charge.
Supply and Fix LED lights fitting 1x10W, 220V, 2 feet, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilling rose complete all as specified and as directed HAVELLS CATALOGUE NO: ENDURLINEARNEOBS10LED865SPCWH or equivalent in Philips/Crompton
Supply and Fix surface mounted ceiling LED round down light fitting, 12 watts with die cast aluminium housing, High trasititvity non yellowing virgin PMMA diffuser system wattagw of 12W, 6000K color temperature and CRI 70, power factor 0.9 Driver should meet IEC complaint for safety with multi stage high isolated CC-CV operated driver with voltage RANGE 150 TO 270 Volts, AC, safety extra low voltage safe level 60V DC and surge protection of 3 KV system efficacy at liminary level 80 lumens/watt, 50000 burning hours as per L70 Criteria and including connecting up with PVC shethed 3 core 1.5 Sqmm copper conductor flexible wire fixed ocmplete all as specified and directed.
Material and Labour for fabricating and fixing factory made cubical panal made out of 2mm thick duly powder coated CRCI sheet of suitable size with sufficeient space arround the meter to accommodate single phase electric meter 14 Nos fixed on Hylum sheet of 6mm thick, flush mounted indoor type double door with locking arrangement and provision of 14 Nos transparent fibre glass sheet for taking meter reading, connectng the meter with suitable copper wire and lugs etc all as specified and directed Note:- Elect meter will be measured and paid seperately.
ROAD / PATH / HARD STANDING /CULVERT
Supply and Fix Poly Carbonate Convex mirrors outdoor type 1000mm dia made out of fiber alongwith bracket, pole mounted and fixed to M.S pipe 80 mm dia of total length 2.4m(i.e. 0.6m in ground nd 1.8m above gound) including two coats of synthetic enamel paint over a coat of red oxide primer embedded in PCC 1:3:6type C2 (using 40mm graded aggregates)of size 0.6 x 0.6m including necessary earthwork required for post holes complete all as specified and as directed. Make: Frotier Polymers Pvt Ltd, model no. FCMO - 100 or equivalent model in TATA BP SOLAR/ Avery dennison (India) Pvt Ltd.
Note: The unit rate quoted shall be deemed to include the cost of excavation in post hole of any kind of soil/hard surface and making good the disturbed surfaces.
EXTERNAL WATER SUPPLY
Supply, lay and testing Ductile Iron pressure pipes of size 100mm bore with spigot & socket ends, cast special, class K7 conforming to IS 8329 with inside surface of centrifugally cast cement mortar lined and outside with zinc coating suitable for tyton joint (Push-on joint) in any length laid to level or to falls in trenches/ on grounds / on supports including DI specials as required at site and jointing with flexible push-on type gasket of electrometric (EPDM) joining materials conforming to IS:5382 and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified.
Note: (a) The unit rate quoted shall be deemed to include the cost of push-on type gasket joints. (b) Excavation and earthwork, Returning, filling in and removal of soil shall be measured and paid separately under relevant items. (c) Lead Joints, D-Joints and DI Specuials will be measured and paid separately. (d) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department. (e) Contractor is responsible for repair/ replacement of Under Ground HT/LT/OFC Cables etc and making good of any damages to the existing structures, during the course of execution.
Supply and fix Ductile Iron specials and fittings such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc) tee pieces, single branch. "Y junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs conforming to IS 9523:2000 suitable for DI pipes of flanged/socket ends of sizes 100mm bore to 200 mm bore complete all as specified and directed.
EXTERNAL WATER SUPPLY (BOREWELL)
Drilling trial bore well vertically by using high speed reverse rotary fast rig machinery or any other approved method of size 150mm dia depth type of soil/rock strata such as hard/ dense soil, soft /loose soil, sandy clay, red clay, moorum, weathered rock, hard rock, slightly fracturered rock, pebbled rock or any other geological formation at given location by ground water survey experts all as per IS-2800 for a depth not exceeding 150m below ground level complete all as specified and as directed.
Drilling trial bore well vertically by using high speed reverse rotary fast rig machinery or any other approved method of size 150mm dia to 200m dia depth type of soil/rock strata such as hard/ dense soil, soft /loose soil, sandy clay, red clay, moorum, weathered rock, hard rock, slightly fracturered rock, pebbled rock or any other geological formation at given location by ground water survey experts all as per IS-2800 for a depth not exceeding 150m below ground level complete all as specified and as directed.
Drilling trial bore well vertically by using high speed reverse rotary fast rig machinery or any other approved method of size 200mm dia to 250m dia depth type of soil/rock strata such as hard/ dense soil, soft /loose soil, sandy clay, red clay, moorum, weathered rock, hard rock, slightly fracturered rock, pebbled rock or any other geological formation at given location by ground water survey experts all as per IS-2800 for a depth not exceeding 150m below ground level complete all as specified and as directed. Notes for item No.23 to 25 (a) The quantities of the items shall vary based on the success of the borewell. Please refer Special Condition on tubing here-in-after
(b) The unit rate quoted is deemed to include for collection of soil samples and strata for every 3 mtrsr interval or wherever is a change in strata's and samples shall be preserved in a suitable strata sample box removal of mud and slurry from the site, hire charges of rig, tools and plants, machinery, fuel charges, labour, consumables, transportation, drilling and operation including use and waster of all necessary appliances and materials in complete all respects to entire satisfaction of Engr-in-Charge. (c)The result of drilling mentioned total depth drilled, casing length lowered, depth at which fractures encountered their corresponding yields, totl yield shall be supported with a bore well chart after completion of the drilling the cost of for the test is deemed to be included in the quoated unite rate.
(d)ERW/MS/GI pipe, MS cap and PCC as required shall be measured and paid seperately. (e)The hydro geological investigation by CGWB is availible in the office of GE (F)Bangalore, The tenderer shall refer the same before quoting for the items.
Supply, lowering and fixing in position 150mm nominal bore ERW heavy duty MS housing pipe of 600mm wall thickness welded joints with MS ring around the pipes with MS flat iron 50mmX6mm all as specified and directed complete.
Yield test of bore well (V-notch type) continuously for 08 hours in the presence of department representative nominated vt Accepting Officer and submitting the test report including all equipment and consumable etc. complete all as specified and as directed.
Getting of water samples of bore well tested (chemical and bacteriological analysis) by any NABL accredited labs including collection of samples from various bore well in clean sterilized bottles, transportation and collection and submission of report in triplicate complete all as specified and as directed.
Supplying and connecting PVC insulated flexible flat 3 core submersible cable with copper conductors of size 6 sqmm fromo control panel near borewell to submersible pump set. Make havells Code: WHPNDSKS36x10 or equivalent in standard/ Finolex/HPL
Developing and flushing the bore well with high pressure compressed air and thereafter by pumping muddy water with 25% extra capacity pump till clear water flows out complete all as specified and as directed by Engr-in-Charge Note :- Developing period shall be minimum of 24 hrs per borewell or till clear water flows whichever is later
Supply, lowering, testing and commissioning of submersible pump set, vertical type, multistage with stainless steel impellers, duly coupled to submersible electric driven motor, AC 3 phase, 415 volts, 10 HP Pump 60LPM -250 M discharge capacity with 150 mtrs head, including provision of non-return valve both ends screwed of size 50mm dia fixed to 50mm dia bore of pipe including connecting to 3 core copper conductor submersible cable (water proof) of of suitable size complete all as specified and as directed by Engr-in-Charge Make -Model - Kirbaskar, Cat Ni KS6B -1020 discharge pipe dia 50mm or equivalent Notes: (a) Particular model of pumpset with number of stagings shall be approved by Garrison Engineer. (b) The quoted rate shall be inclusive of following:-
(i) Two nos of steel wire ropes of not less than 6mm dia shall be supplied alongwith pumpset (ii) Water level controller alongwith 5 core cable of suitable capacity, lowering down upto the level of pumpset complete with sensor (iii)Above given discharge and head are tentative capacity of submersible pump to be provided shall depend on yeild and depth of borewell. The capacity of submersible pump shall be decided by garrison engineer after yeild test. Draw down level accodrdingly ascertaining the depth of borewell and water level the pump to be installed
Supply and fixed stainless steel quarter turn wall mixer complete all as specified and as directd by Engr-in-charge Make-CERA garnet car part No CERAF2002403 or equivalent
Supply and fixed quarter turn fittings central holes basin mixer(Chrome finish) complete all as specified and as directed by Engr-in-charge Make-CERA garnet cat part No CERAF2002461 or equivalent
EXTERNAL ELECTRIC SUPPLY
Supply and fix FRP pole box of size 200X18X98mm ,thermoplastic and polycabonate, IP-66 with all accessorries complete with connector and Mcb SP 6 Amps for steet light all as directed.
Supply and Fix cable oute indicator Oval shape 200X150X6mm cast iron fixed on 25x25x6mm angle iron including marking of HT/LT UG Cable duly painted and grounted in PCC complete all as specified and as directed.
Supply, Installation, testing and commissioning of LT feeder pillar box, /panel board IEC - 614391, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3.5sqmm thick CRCA sheet steel and MS angle section 50x50x6mm 3 phase 4 wire base frame 440 volts 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc., powder coated as per seven tank process and IP 55 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral copper bus bar of 400 amps with PVC insulator heat shrink colour code sleeves, 11 tank process, ISO 14001:9001, mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, PCC works complete with copper strips of suitable size for connecting MCCB complete and comprising of the following:-
(i)Aluminium bus bar 3 phase and neutral of capacity 400 Amps (ii) MCCB 4 pole 320 Amps 35 KA, -01 No (Incoming) (iii)MCCB 4 pole 160 Amps 35 KA, -03 No (For proposed building Block No 1 and 2 outgoing for APFC Panel (iv)MCCB 4 pole 63 Amps 25 KA, -02 No(Outgoing) (v)Multifunction meter - 01 No (vi)LED phase indication lamp for 3 phase - 01 set (vii)Time Switch 415 V three phase
UNITED TECHNO PROJECTS PVT LTD
SRI BALAJI INFRA PROJECTS
C R R CONSTRUCTIONS
AFSON ENGINEERS & CONTRACTORS
SREEKRISHNACONSTRUCTIONS
Phoenix Infra
M/s M Munivenkatappa and Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .