Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-Finance | ₹3.2 Cr | L1 | Accepted-Finance The lowest evaluated responsive bidder |
| 2 | L2₹3.2 Cr+₹2.2 L (0.68%)Rejected-Finance | ₹3.2 Cr+₹2.2 L (0.68%) | L2 | Rejected-Finance Not responsive as per SBD |
| 3 | Rejected-Technical | - | - | Rejected-Technical The firm has fail to fulfilled required qualiafication criteria as per SBD. |
| 4 | Rejected-Technical | - | - | Rejected-Technical The firm has fail to fulfilled required qualiafication criteria as per SBD. |
| 5 | Rejected-Technical | - | - | Rejected-Technical The firm has fail to fulfilled required qualiafication criteria as per SBD. |
Tender Value
₹3.6 Cr
EMD Value
₹7.2 L
Closing Date
6 Aug 2020, 4:00 pmClosed
DPIU, RWD, LONGDING, A.P.
O/O THE EE cum DPIU, RWD, LONGDING, A.P.
Pavement, Culverts, HPC, Puccaa side drains, Protection Wall, KM stone and Logo
2020_CEAR_95321_1
AR22AR09/01/012
Open Tender
Civil - Roads and Bridges
Piece-work
Longding, Arunachal Pradesh
As Per SBD
8 documents required · 8 mandatory
₹15,000
ARRDA
₹7.2 L
Yes
MIAO, DIST. CHANGLANG, A.P.
9 Oct 2020
22 Jun 2020
11 Aug 2020
25 Jun 2020
6 Aug 2020
25 Jun 2020
1 Jul 2020
Amount
EARTHWORK IN ROAD FORMATION
Earthwork in excavation in soil in hilly area by mechanical means including cutting and trimming of sides slopes and disposing of excavated earth with a lift upto 1.5m and a lead upto 20m as per Technical Specification clause 1603.1
Excavation in ordinary rock using mechanical means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.
Item : Slab Culvert 1.50 mtr. span, 3.13 mtr high (As per IRC SP-20-2002)
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10)
a) Foundation & Plinth
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
Back filling behind the abutment, wing wall and retain wall completeas per the drawing & technical specification.[Granular material]
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 20) 1:2:4 Nominal mix
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 25) 1:1.5:3
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (P.C.C. grade M 20 ) ( Coping of Return wall)
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
a) For nominal mix 1:2:4[hand mixing]
Supplying, fitting and placing with HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
a) HYSD Bars Reinforcement
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 (DRRM Appron)
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5 [RRM in CM 1:5] (Toe Wall)
Item : Slab Culvert 2.00 mtr. span, 3.64 mtr high (As per IRC SP-20-2002)
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10)
a) Foundation & Plinth
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
Back filling behind the abutment, wing wall and retain wall completeas per the drawing & technical specification.
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 20) 1:2:4 Hand mix
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 25) 1:1.5:3
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (P.C.C. grade M 20 ) ( Coping of Return wall)
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
a) For nominal mix 1:2:4[hand mixing]
Supplying, fitting and placing with HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
a) HYSD Bars Reinforcement
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 (DRRM Appron)
Item : Hume Pipe Clvt. 1000 mm dia.TYPE-I (As per IRC SP-20-2002 & SP :48-1998)
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 [P.C.C. grade M 20 Nominal mix (1:2:4)]
Bedding for Pipe [ Type A ( Concrete Cradle ) Bedding ]
Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i)
Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109 [In 1:4 cement mortar]
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106. [1000 mm dia]
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 [R.C.C grade M 20 For design mix RCC M 20]
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Item : Sausage wire crated boulder Protection Structure
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301. ( Based on SDB Rural Road Chapter-14, Item No.14.2)
Item : Side Drain [V- Shape] ( Cross section as per IRC SP-20-2002 -RRM , Page 113 , Fig. 6.2.c )
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (i) Upto 3m depth
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 803, 1202 ans 1203 [M -15 Plain base concrete]
Stone Masonry work in cement mortar in foundation complete as per drawings and technical specification Clauses 702,704,1202 & 1204 [CRM in CM 1:5]
Cement plaster 15 mm thick 1:4 on stone masonry
SHOULDER
Construction of subgrade and earthen shoulders with approved material obtained from way cutting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.
Granular Sub-base with Well Graded Material ( Clause Table 400.2) Grade-B :-
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Drawing and Technical Specificateion Clause No 401[Gravel/Soil-Aggregate Base (Table 400.2) Grading B]
WBM-III FOR BASE COURSE ( 75 mm thick)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fillup the intersices of coarse aggregate,watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.(a)By Manual means.
PRIME COAT
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 [Low porosity]
Tack coat
Providing and applying Tack Coat with Bitumen Emulsion (RS-1)using emulsion distrubuter @ 0.25 to 0.30 Kg per Sqm. On prepared dry and hungry bituminus surface clean with hydraulic broom as per technical specification 503.
20 mm thick Open Graded Premix Carpet using Bitumen Emulsion as per Technical Specification Clause 508.2
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates(0.27Cum/10Sqm) either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100kN static roller capacity ,finished to required level and grades to be folloed by seal coat of either Type - A orType - B or Type - C as per Technical Specification . By Manual Means[Bitumen Emulsion]
Seal Coat :-
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 By Manual Means. Type- A [Bitumen Emulsion(S-S)]
Item :-Road Furniture:-
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
a). Ordinary 1 Km-stone (size - 66 X 35 X 25 cm)
b) 5th Km. Stone (size 107.50x58x25cm)
c) 200m stone (precost)
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
Routine Maintenance for 3.20 Km.
First Year
Second Year
Third Year
Fourth Year
Fifth Year
Add GST @ 12%
M/S DAGMO RIBA
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .