Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.0 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹10.9 L+₹90,142.90 (9.01%)Accepted-Finance | 2 | Accepted-Finance L2 | |
| 3 | 3₹12.6 L+₹2.6 L (26.0%)Accepted-Finance | 3 | Accepted-Finance L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Technical bid is rejected due to experience not properly uploaded and not similar nature hence rejected. |
Tender Value
₹14.2 L
EMD Value
₹28,405
Closing Date
18 Jan 2024, 3:00 pmClosed
Executive Engineer PRI Lucknow Mayabunder
Office of the Executive Engineer PRI Mayabunder
Construction of Paid Vehicle Parking at Panchawati under GP, Shivapuram.
2024_RDPRI_12914_1
97/EE/PRI/MB/23-2024
Open Tender
Civil Works - Others
Works
180 days
Shivapuram
Refer Tender Document
5 documents required · 5 mandatory
₹500
Yes
Executive Engineer PRI N and MAD Mayabunder
₹28,405
Yes
19 Jan 2024
5 Jan 2024
18 Jan 2024
5 Jan 2024
18 Jan 2024
5 Jan 2024
Amount
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Supplying and stacking at site.
90 mm to 45 mm size stone aggregate
63 mm to 45 mm size stone aggregate
53 mm to 22.4 mm size stone aggregate
Stone screening 13.2 mm nominal size (Type A)
Stone screening 11.2 mm nominal size (Type B)
Moorum
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications :
On W.B.M @ 0.75Kg/Sqm
2 cm premix carpet surfacing with 1.8 cum and 0.90 cum of stone chippings of 13.2 mm size and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately).
With paving Asphalt grade VG - 30 with no solvent
Providing and laying Shredded Plastic @ 8% of Bitumen consumed including carriage of the same Port Blair (Only in the item of laying 2 cm premix carpeting ).
Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 Pulverised sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources).
1:3:6 (1 Cement : 3 Pulverised sand (zone-III) derived from natural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level :
1:1.5:3 (1 cement: 1.5 Pulverised sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
1:2:4 (1 Cement : 2 Pulverised sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
1:1.5:3 (1 cement : 1.5 Pulverised sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III)derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
12 mm cement plaster of mix :
1:4 (1 cement: 4 River sand)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
On concrete work
ELECTRICAL WORKS
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and fixing of Energy Saving IP65 flood light (100W LED) luminaire with high power LED as light source (Lamp Type Havells JETA IRIS CAT NO. JETAALBAFLOODLIGHT100W). Make: Bajaj/Havells/Panasonic/Crompton or equivalent to ISI Standard.
Supplying of 100mm x 100mm x 10mm GI angle for cross arms size (0.90M) fixing in GI pole in which the LED lights are mounted complete with fixing clamps, bolts, nuts and washer drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying and fixing of Hot pressed moulded SMC Box 280x170x100mm to house, 6 to 32 Amps MCB, 63 A 230V 4 way connector and clamping arrangement for SMC box etc. as required. (a) SMC box (280mm x 170mm x 100mm - 01 No.), (b) MCB 6Amps - 01 No. ( c ) 63 A, 230V, 4 way connector - 01 No.
Supplying of laying of following size (DWC HDPE) double walled corrugated high density polyethylene pipe ISI marked alongwith all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc direct in ground (75 cm below ground level) including excavation and re-filling the trench but excluding sand cushioning and protective covering etc as required.
63 mm dia (OD-63mm & ID-51mm nominal) details of cost for 50 meter
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench, but excluding sand cushioning, protective covering etc as required.
Upto 35 sq.mm
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amps, 2 Pole Isolator
Supplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB/Isolator)
2 way, Single door
Supplying of 3 Core 4.0 Sq.mm Armoured Copper Cable XLPE insulated core laid up, PVC tape inner sheathed for multicored cables armour galvanized wire for cable extruded PVC type ST2 sheathed 650 /1100V grade as pe IS 7098 (PART-I) 1988 as required. (Make: Havells/Polycab/Standard or equivalent to ISI Standard).
Supplying of 3 Core 6.0 Sq.mm Armoured Copper Cable XLPE insulated core laid up, PVC tape inner sheathed for multicored cables armour galvanized wire for cable extruded PVC type ST2 sheathed 650 /1100V grade as pe IS 7098 (PART-I) 1988 as required. (Make: Havells/Polycab/Standard or equivalent to ISI Standard).
Fabrication and Supplying of Street Light pole made out of 65mm dia 'B' Class ISI marked G.I.Pipe 6.0 meter long with earth stud and necessary G.I reducer/coupling fixed at the top and 300x300x6mm thick MS bare plate welded to the bottom including painting with one coat of metallic primer to 2 coat of synthetic enamel paint etc as required.
PAUL ENTERPRISES
SELVAM RAJESH
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .