Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC 0 BUDKIYA DEVATRA JODHPUR RAJASTHAN 342606 | JODHPUR | RAJASTHAN | 342606 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹40.8 L+₹3.4 L (9.03%)Rejected-Finance 1542 URBAN ESTATE II HISAR 125 005 HARYANA | HISAR | HARYANA | 125005 | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹41.9 L+₹4.4 L (11.9%)Rejected-Finance 182 INDRA COLONY VILL DAMODARPURA POST TODABHATA TEA BASSI BASSI JAIPUR JAIPUR RAJASTHAN 303301 | JAIPUR | RAJASTHAN | 303301 | L3 | Rejected-Finance Being L3 bidder | |
| 4 | L4₹42.8 L+₹5.4 L (14.3%)Rejected-Finance | L4 | Rejected-Finance Being L4 bidder | |
| 5 | L5₹43.8 L+₹6.3 L (17.0%)Rejected-Finance | L5 | Rejected-Finance Being L5 bidder |
| Sl No | Description | Qty | Unit | malik constructions L4 | Balaji Construction Co. L3 | m/s krishna engineers1 L2 | OM CONSTRUCTION CO. L1 | M/s Rao Constructions, 1173 Urban Estate-II, Hisar L5 | M/S SM BUILDER CO L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster of any layers upto brick level upto three Storey including scaffolding including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. | 3,270 | Sqm | 25 ₹81,750 | 20 ₹65,400 | 10 ₹32,700 | 5 ₹16,350 Lowest | 10 ₹32,700 | 20 ₹65,400 |
| 2.00 | M&L for 15mm thick rendering in CM 1:4 over brick / concrete wall surfaces trowelled to even & smooth without using extra cement for external wall surfaces upto three storey including scaffolding Bldgs mixed with WPC as per manufacturer instruction complete all as specified and directed.
Note : The above quoted price are including of WPC ) | 2,000 | Sqm | 165 ₹3,30,000 | 160 ₹3,20,000 | 150 ₹3,00,000 | 140 ₹2,80,000 | 120 ₹2,40,000 Lowest | 160 ₹3,20,000 |
| 3.00 | M&L Rough cast plaster as specified .(Rendering coat not less than 10mm thick in C:M 1:3 , while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg size 6 to 12mm mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even) on external wall upto cill height complete all as specified and directed. | 700 | Sqm | 150 ₹1,05,000 | 130 ₹91,000 Lowest | 180 ₹1,26,000 | 140 ₹98,000 | 140 ₹98,000 | 150 ₹1,05,000 |
| 4.00 | M&L, 15mm thick rendering upto three storeys in CM 1:6 to brick/concrete wall surfaces trowelled to even & smooth without using extra cement complete all as specified and directed. | 500 | Sqm | 220 ₹1,10,000 | 150 ₹75,000 | 140 ₹70,000 | 160 ₹80,000 | 120 ₹60,000 Lowest | 140 ₹70,000 |
| 5.00 | Description all as per item No. 4.00 above but 10mm thick in CM 1:3 as in ceiling, Chajjah, facia and complete all as specified and directed. | 70 | Sqm | 225 ₹15,750 | 90 ₹6,300 Lowest | 140 ₹9,800 | 160 ₹11,200 | 100 ₹7,000 | 130 ₹9,100 |
| 6.00 | M & L for preparation of newly plastered surface of walls upto three storeys including scaffolding and applying two coats of OBD using roller over a coat of 2mm thick average wall care putty on wall complete all as specified and directed. | 400 | Sqm | 45 ₹18,000 | 30 ₹12,000 | 30 ₹12,000 | 35 ₹14,000 | 20 ₹8,000 Lowest | 65 ₹26,000 |
| 7.00 | M&L preparing new plastered surfaces of walls upto three storeys including scaffolding and applying two coat of cement base paint over one coat of primer using roller complete all as specified and directed. | 1,700 | Sqm | 28 ₹47,600 | 25 ₹42,500 | 25 ₹42,500 | 30 ₹51,000 | 20 ₹34,000 Lowest | 30 ₹51,000 |
| 8.00 | M&L for preparing new plastered or unplastered surface of walls upto three storeys including scaffolding and applying two coats of weather proof paint , over and including of a coat of exterior wall primer as approved by Manufacture and complete all as specified and directed. | 600 | Sqm | 85 ₹51,000 | 60 ₹36,000 Lowest | 75 ₹45,000 | 80 ₹48,000 | 60 ₹36,000 Lowest | 65 ₹39,000 |
| 9.00 | M&L for preparation newly plastered surfaces of wall upto three storeys including scaffolding and applying three coats of white wash complete all as specified and directed. | 500 | Sqm | 8 ₹4,000 | 5 ₹2,500 Lowest | 15 ₹7,500 | 15 ₹7,500 | 8 ₹4,000 | 20 ₹10,000 |
| 10.00 | M&L preparing new plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed. | 70 | Sqm | 10 ₹700 | 4 ₹280 Lowest | 15 ₹1,050 | 15 ₹1,050 | 8 ₹560 | 20 ₹1,400 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
27 Aug 2025, 6:00 pmClosed
GE (W)
GE (W) HISAR HISAR MIL STN PIN-125006
CA NO. GE(W)/HSR-24/2025-26 PERIODICAL SERVICES INCL IN INTERNAL ELECTRIFICATION IN JCO/OR MD ACCN, MES COLONY, OTM ACCN IN ZONE A UNDER AOR OF AGE B/R-II OF GE (WEST) HISAR AT HISAR MIL STN
2025_MES_723316_1
CA NO. GE(W)/HSR-24/2025-26
Open Tender
Civil Works
Item Rate
270 days
HISAR
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (W) HISAR
₹98,000
GE (W) HISAR
10 Oct 2025
30 Jul 2025
29 Aug 2025
30 Jul 2025
27 Aug 2025
13 Aug 2025
31 Jul 2025 - 7 Aug 2025
7 Aug 2025
Amount
Taking down cement plaster of any layers upto brick level upto three Storey including scaffolding including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 over brick / concrete wall surfaces trowelled to even & smooth without using extra cement for external wall surfaces upto three storey including scaffolding Bldgs mixed with WPC as per manufacturer instruction complete all as specified and directed. Note : The above quoted price are including of WPC )
M&L Rough cast plaster as specified .(Rendering coat not less than 10mm thick in C:M 1:3 , while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg size 6 to 12mm mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even) on external wall upto cill height complete all as specified and directed.
M&L, 15mm thick rendering upto three storeys in CM 1:6 to brick/concrete wall surfaces trowelled to even & smooth without using extra cement complete all as specified and directed.
Description all as per item No. 4.00 above but 10mm thick in CM 1:3 as in ceiling, Chajjah, facia and complete all as specified and directed.
M & L for preparation of newly plastered surface of walls upto three storeys including scaffolding and applying two coats of OBD using roller over a coat of 2mm thick average wall care putty on wall complete all as specified and directed.
M&L preparing new plastered surfaces of walls upto three storeys including scaffolding and applying two coat of cement base paint over one coat of primer using roller complete all as specified and directed.
M&L for preparing new plastered or unplastered surface of walls upto three storeys including scaffolding and applying two coats of weather proof paint , over and including of a coat of exterior wall primer as approved by Manufacture and complete all as specified and directed.
M&L for preparation newly plastered surfaces of wall upto three storeys including scaffolding and applying three coats of white wash complete all as specified and directed.
M&L preparing new plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
M&L for preparation of old surface of walls including pillars etc upto three storeys including scaffolding (plastered or unplastered) by scrapping down smoke spot moulds, moss and efflorescence salt and treating oil and greasy spots using mechanical sander with internal dust extraction system and applying one coat of white wash complete all as specified and directed.
Description all as per item No 11.00 above but one coat of white wash on ceiling complete all as specified and directed.
M & L for complete removal of existing treatment of old surface of any layer of wall using mechanical sander with internal dust extraction system and applying two coats of OBD over a coat of 2mm thick average wall care putty over a coat of alkali resistance primer of same make on wall complete all as specified and directed.
M & L for preparation of old surface of wall using mechanical sander with internal dust extraction system and applying one coat of OBD and complete all as specified and directed.
M & L for preparation old surface of wall using mechanical sander with internal dust extraction system and applying two coats of OBD using roller and complete all as specified and directed.
M&L for 2mm average thickness wall care putty and complete all as specified and directed.
M&L for preparing old plastered or unplastered surface of walls upto three storeys incl scaffolding with and including complete removal of existing treatment of any layer of wall using mechanical sander with internal dust extraction system and applying two coats of weather proof paint over and incl of a coat of exterior wall primer as approved by Engineer-in-Charge and complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soots, moulds, moss and efflorescent salts and trading oil & greasy spots including cornices etc using mechanical sander with internal dust extraction system and applying one coat of cement base paint, white or tinted colour complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soots, moulds, moss and efflorescent salts and trading oil & greasy spots including cornices etc using mechanical sander with internal dust extraction system and applying two coat of cement base paint, white or tinted colour complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of any tint all as specified and directed.
M&L for preparation of old painted surfaces of iron works of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of any tint all as specified and directed.
M&L preparation of old concrete painted surfaces of any description, over 10 cm in width or girth, and applying two coats of synthetic enamel paint complete all as specified and directed.
Removing all disintegrated and loose concrete of any thickness including plaster if any in RCC Column, Chajja, beams, Ceilings, lintels etc, removing all loose rust/scale form exposed reinforcement bars by using wire brushes and sand paper including cleaning of exposed surfaces of reinforcement with protective anti corrosive epoxy bonding chemical (make : Pidilite) and tied reinforcement bars/ IRC fabric 50mm X 50mm X 12gauge if reqd to reinforcement concrete bonding primer uniformly to exposed surfaces and applying cement mortar 1:3:1 with MPC (1 Part cement : 3 Part Sand : 1 Part 6mm coarse aggregate) to an average thickness not less than 20 mm and removing debris outside MD land all as specified and directed. Note : IRC 50x50x12 gauge shall be measured and paid separately.
Supply only IRC 50mm X 50mm X 12 gauge weld mesh cut to length bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm or fixing with galvanised steel staples fixed to steel members with nut and bolt or fixed to RCC work or ceiling surfaces complete all as specified and directed
Demolition of RCC Roofs, floors (other than ground floors), beams, staircases, landing, chajjas upto three storey ,RCC water Tanks and similar suspended work and making good the disturbed area in CM 1:3 complete all as specified and directed.
Excavation in post holes each n. exc .50 cum, getting out in soft/loose soil and removing surplus material n. exc 50 mtr and making good disturb surfaces complete all as specified and directed.
M& L PCC 1:3:6 type C-2 as in foundation of posts and struts complete all as specified and directed.
S&F prepainted galvalume alumimium zinc coating GI based Corrugated steel sheet 0.50 mm thick of any color having tensile strength of 550 MPA as a roof covering /Cladding to wall and in Chajjah , Fixed with self tapping screw including dismantling of old sheets of any type wherever applicable and complete all as specified and directed.
S&F mild steel joist, channel, angle ,tee fixed independently without connection plates etc (cut to ordinary length i.e. within 20mm of the length indicated ) including cutting holes in walls for inserting support for chajjahs/ cooler plateforms / cooler stand etc and making good dismantled portion with PCC and plaster and complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for and complete all as specified and directed.
S&F Framed work Fe- 290 (Gde E-165)as in doors or gates of angle or other section with gusset plates ,rails,poles and framework for shades ,braces etc complete drilled for fixing of steel sheeting or other coverings . Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings also inclusive of of steel sheeting or other coverings, running rails and guides and hanging also fastening and fixing complete all as specified and directed.
M&L preparation of new steel surfaces of any description, over 10 cm in width or girth, and applying two coats of synthetic enamel paint complete all as specified and directed.
Demoliton of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing debries out of MD land complete all as specified and directed.
M&L Brick work with old size burnt bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed.
M&L for the supply and installation of window blinds (vertical/roller/venetian, as reqd and approved) suitable for office/room/auditorium use. The blinds shall be of premium quality, made from dust-resistant, UV-protected, fade-resistant fabric or PVC, and of approved shade, color, and design inclusive with all accessories: brackets, operating chain/cord, bottom weights, end caps, and fixing hardware. The blinds must be easy to operate, retractable, and capable of providing light control and privacy complete all as specified and directed.
S&F hollow PVC Fluted/ louvers wall paneling, super strong quality single side prelaminated with flat or fancy patterned on laminated side, including PVC 'L' and 'U' sections for finishing of corners and ends etc inclusive of fixing with screw or with solvent cement required at site on walls including dismantling of old unsv wall panelling of any type including cover fillet and frame work complete as specified and directed.
Taking down carefully copper/ Aluminium point wiring ( light, fans, socket, power socket) complete including taking out existing unserviceable terminal boxes and conduit with switches/sockets/fan regulators and fittings such as ceiling roses, pendants, tube lights fittings lamp holders, brackets light fittings, rectangular blocks DB MCCB etc and making good disturbed surface of wall/ floor etc to match with the existing the surface etc complete all as specified and directed.
Taking down carefully copper/aluminium Submain wiring from battan /conduit from DBs, MCBs, etc) and making good to disturbed surfaces of walls, floor etc complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic existing concealed conduit 19/20 mm dia medium duty, ISI marked to be terminated & including pressed modular steel boxes & cover plate of module as required on site.including 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multisrtaned copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in Cm 1:3 and finishing the surface as per exisitng treatment complete all as specified and directed.
Description all as per item No 41.00 (here-in-before) but One three pin 5 Amp socket outlet point on indep board controlled by one nos, one way switch on independent board complete all as specified and directed.
Description all as per item No 41.00 (here-in-before) but One three pin 5 Amp socket outlet point on same board controlled by one nos, one way switch on same board complete all as specified and directed.
Description all as per item No 41.00 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on independent board complete all as specified and directed.
Description all as per item No 41.00 above One light point controlled by two 2- way switches, with cables 1.5 sq. mm size complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic new concealed conduit 19/20 mm dia medium duty, ISI marked to be terminated & including pressed modular steel boxes & cover plate of module as required on site.including 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multisrtaned copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in Cm 1:3 and finishing the surface as per exisitng treatment complete all as specified and directed.
Description all as per item No 46.00 (here-in-before) but One three pin 5 Amp socket outlet point on independent board controlled by one nos, one way switch on independent board complete all as specified and directed.
Description all as per item No 46.00 (here-in-before) but One three pin 5 Amp socket outlet point on same board controlled by one nos, one way switch on same board complete all as specified and directed.
Description all as per item No 46.00 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on independent board complete all as specified and directed.
S&F Modular switch 1 way 6A 1 module Single pole, one way, 230 volts complete all as specified and directed.
S&F Modular switch 1 way 16A 1 module complete all as specified and directed.
S&F Modular switch 2 way 6A 1 module Single pole, one way, 230 volts complete all as specified and directed.
S&F Modular socket 6A -2/3 pin combined 2 module type 230 volts AC complete all as specified and directed.
S&F Modular socket 6A/16A -2/3 pin combined 2 module type AC complete all as specified and directed.
S&F Modular lamp holder, insulated body with back plate & LED Bulb 9/12 watt suitable for batten fittings and complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
M&L Buzzer, Ding Dong AC 230 volts, single pole ISI Marked complete all as specified and directed.
Supply and fixing modular bell push 6A 1 module completed all as specified and directed.
S&F Modular ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc in repair complete all as specified and directed.
Supply & fixing in repair ceiling fan regulator electronic step type suitable for 1200mm/1400mm sweep fan complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in repair Sheet metal enclosure distribution board SP&N,8 way, double door powder coated, protection class IP-42 suitable for mounting MCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar complete all as specified and directed .
Supply and fixing in repair MCBs SP 6 to 32Amps, 240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed. Note : Make of the MCB should be the same as that of DB
Supply and fixing in repair MCBs SPN 32Amps to 63 Amps, 240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed. Note : Make of the MCB should be the same as that of DB
S&F in repair Sheet metal enclosure distribution board TPN, 4 way, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers proper with PCC works complete all as specified and directed.
Supply & fixing in replacement of Bldg security light fitting LED 30 W, pressure die cast housing epoxy powder coating IP -65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 40 mm bore light grade, 1.5 mtr length and fixed with MS Calmps of size 40x5 mm-02 nos,nuts, bolts and washers on wall complete all as specified and directed.
M & L for submain wiring alongwith earth wire with the 2x6.0 sq. mm +1x6.0 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required (The above mentioned specified runs of single core cables and specified runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one run length) complete all as specified and directed.
M & L for submain wiring alongwith earth wire with the 2x10 sq. mm +1x10 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required(The above mentioned specified runs of single core cables and specified runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one run length) complete all as specified and directed.
supply and fixing paino flush type switch 5 amp 1 way complete all as specified and directed.
supply and fixing paino flush type switch 15 amp 1 way complete all as specified and directed.
supply and fixing 5 amp socket flush type complete all as specified and directed.
supply and fixing 15 amp socket flush type complete all as specified and directed.
supply and fixing metal flush box 1/2 module complete all as specified and directed.
supply and fixing metal flush box 3 module complete all as specified and directed.
supply and fixing metal flush box 4 module complete all as specified and directed.
supply and fixing metal flush box 6 module complete all as specified and directed.
M&L for Earthing complete with galvanised mild steel earth electrode plate 600 X 600 X 6 mm thick buried directly and vertically in ground connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion ncluding provision of earth wire protected by galvanised iron 15 mm bore medium grade pipe with all fittings from the earth electrode fixed along pole or wall with and including 25 x 6mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium grade from top of the earth pit to top of earth plate electrode including all excavation and earth work in any type of soil and removal of soil upto 50 metre, PCC pit with pre-cast RCC cover with handle, charcoal/salt, funnel , CI frame etc complete all as specified and directed. NOTES : (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.00 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Items includes cost of 7.5 metre earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
m/s krishna engineers1 (BID ID -3407472)
Balaji Construction Co. (BID ID -3406526)
malik constructions (BID ID -3404647)
M/s Rao Constructions, 1173 Urban Estate-II, Hisar (BID ID -3408371)
M/S SM BUILDER CO (BID ID -3407277)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .