| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Demolition of cement concrete unreinforced of any description and in any position, not otherwise specifically provided for and M & L for cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregates for filleting, benching, slightly rounding or chamfering on edges, filling undulations / depressions in roof surface, providing concrete platform for tanks wherever required as directed. | 0.5 | Cum | - | - |
| 2 | Taking down / removing existing water proofing treatment from RCC roof slab including removal of plaster bed below felt / membrane and disposal of the same to distance exceeding 50m but not exceeding 100m as and where directed and M & L for 10 mm thick screeding / rendering in cement mortar 1:3 on concrete roof surface, using Water Proofing Compound @ 3% by weight of cement, surface finished even and smooth without using extra cement all as directed.
Note: Water Proofing Compound shall be measured and paid separately. | 300 | Sqm | - | - |
| 3 | Supply only intergral water proofing compound. | 104.7 | Kg | - | - |
| 4 | M&L for Cutting out cracks to "V" section in existing roofs or terracing, cleaning out wetting grouting with cement and sand slurry 1:3 | 10 | Rm | - | - |
| 5 | M & L for cleaning the plastered /concrete surface with wire brush and applying water proofing treatment as under:-
(a) Apply a uniform coat of primer at 0.70 kg/sqm over cement plaster.
(b) 3 mm thick and weighing not less than 3.6 kg/sqm Atactic Polypropylene Polymer (APP) modified bitumen - based prefabricated five layer water proofing membrane reinforced with non woven polyester matt black finished over compatible primer at 0.40 Ltr/sqm of density at 25 degree centigrade 0.87 - 0.89 kg/litre and viscosity 70-160 cps or cold sticker and torch application of membrane with 10 cm overlap both ways after necessary preparation of surface complete as per manufacturers instructions.
(c) Apply two coats of bitumastic - aluminium paint over the membrane. | 300 | Sqm | - | - |
| 6 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level ) all as specified and directed | 17.93 | Cum | - | - |
| 7 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing coat) | 367 | Sqm | - | - |
| 8 | M & L for 25 mm thick PCC 1 :2 : 4 type B0 ( Using 12.5 graded stone aggregate ) as in base of floors complete all as specified and as directed by Engineer-in-Charge. | 267 | Sqm | - | - |
| 9 | M & L for Vitrified ceramic tiles 10mm thick ( square / rectangular ) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match | 255 | Sq m | - | - |
| 10 | Ditto all as in item No.11 above but as in skirting /dados including 10mm thick rendering in CM 1:4 complete all as specified and directed. | 15 | Sqm | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_884045.xls
BOQ • 0.38 MB
T8850.pdf
Tender Documents • 1.21 MB
NITamendment8850.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .